1.A Promising Method for Tumor Localization during Total Laparoscopic Distal Gastrectomy: Preoperative Endoscopic Clipping based on Negative Biopsy and Selective Intraoperative Radiography Findings.
Joo Weon CHUNG ; Kyung Won SEO ; Kyoungwon JUNG ; Moo In PARK ; Sung Eun KIM ; Seun Ja PARK ; Sang Ho LEE ; Yeon Myung SHIN
Journal of Gastric Cancer 2017;17(3):220-227
PURPOSE: Precise localization of tumors and creation of sufficient proximal resection margins are complicated processes during total laparoscopic distal gastrectomy (TLDG) for clinical T1/T2 gastric cancers. Various solutions to this problem have also yielded many disadvantages. In this study, we reviewed a preoperative endoscopic clipping method based on the results of negative biopsy and selective intraoperative radiography. MATERIALS AND METHODS: A retrospective review of 345 consecutive patients who underwent TLDG and preoperative endoscopic clipping for tumor localization was conducted. During preoperative endoscopy, the endoscopists performed negative biopsies just 1–2 cm selectively above the tumor's upper limit. After confirming the biopsy results, endoscopic metal clips were applied just proximal to the negative biopsy site the day before surgery. Selective intraoperative tumor localization using portable abdominal radiography was performed only when we could not ensure a precise resection line. RESULTS: Negative biopsy was performed in 244 patients. Larger tumor size (P=0.008) and more distally located tumors (P=0.052) were observed more frequently in the negative biopsy group than in the non-negative biopsy group. The non-negative biopsy group had significantly higher frequencies of differentiated tumor types than the negative biopsy group (P=0.003). Of the 244 patients who underwent negative biopsies, 6 had cancer cells in their biopsy specimens. We performed intraoperative radiography in 12 patients whose tumors had difficult-to-determine proximal margins. No tumors were found in the proximal resection margins of any patients. CONCLUSIONS: Our tumor localization method is a promising and accurate method for securing a sufficient resection margin during TLDG.
Biopsy*
;
Endoscopy
;
Gastrectomy*
;
Humans
;
Laparoscopy
;
Methods*
;
Radiography*
;
Radiography, Abdominal
;
Retrospective Studies
;
Stomach Neoplasms
2.Consistency analysis between preoperative CT enterography and intraoperative findings in patients undergoing surgery for Crohn's disease.
Jianbo YANG ; Jianfeng GONG ; Yi LI ; Lili GU ; Weiming ZHU ; Jieshou LI
Chinese Journal of Gastrointestinal Surgery 2017;20(5):555-559
OBJECTIVETo evaluate the diagnostic value of preoperative CT enterography (CTE) on obstruction, fistula and abscess formation compared to intraoperative findings in patients undergoing surgery for Crohn's disease(CD), aiming to provide reference to clinical practice.
METHODSPreoperative CTE data of 176 CD patients confirmed by clinic, endoscopy, imaging, operation and pathology at the Department of General Surgery in Nanjing Jinling Hospital from January 2013 to December 2015 were enrolled in retrospective cohort study. All the patients underwent enhanced full abdominal CT scan using SIMENS SOMATOM Definition Flash 64 row dual-source CT machine. CTE scans were performed from the dome of diaphragm to the symphysis pubis. The CT images in arterial and venous phase were reconstructed with 1.0 mm thin layer, and then processed in MMWP 4.0 workstation including multi-planar recombination, surface recombination and maximum density projection. The sensitivity, specificity, positive and negative predictive value, false negative rate and accuracy of preoperative CTE on obstruction, fistula and abscess were compared with intraoperative findings.
RESULTSAmong 176 patients, 122 were males and 54 were females with median age of 29 (18 to 65) years, median disease duration of 48 (1 to 240) months, median time interval from CT scan to operation of 16(1 to 30) days, and median body mass index of 17.8 (10.8 to 34.7) kg/m. Twenty-six cases (14.8%) had nutritional risk (NRS2002≥3); 23 cases (13.1%) had lesions limited to ileum; 19 cases (10.8%) had lesions limited to colon; 126 cases (71.6%) had simultaneous lesions of ileum and colon, and 8 cases (4.5%) had lesion in upper gastrointestinal tract. A total of 199 lesions of small intestine were identified by preoperative CTE, including 131 of obstruction (65.8%), 42 of fistula (21.1%), and 26 of abscess (13.1%), while 235 lesions were confirmed by operation, including 133 of obstruction (56.6%), 74 of fistula (31.5%), 28 of abscess (11.9%). The modification of planned surgical procedure due to unexpected intraoperative findings were found in 29(16.5%) patients. The sensitivity, specificity, positive predictive value and negative predictive value of preoperative CTE were 86.4%, 78.8%, 86.9% and 76.0% for obstruction; 83.8%, 79.1%, 67.5% and 90.4% for fistula; and 96.2%, 98.0%, 90.1% and 99.3 for abscess, respectively.
CONCLUSIONPreoperative CTE can effectively evaluate the lesions of intestinal obstruction, fistula and abscess in CD patients, with the highest accuracy of abscess, and has quite good consistency with intraoperative findings, which may be used as the first choice of imaging diagnosis of CD.
Abscess ; diagnostic imaging ; Adult ; Aged ; Colon ; diagnostic imaging ; surgery ; Crohn Disease ; diagnostic imaging ; surgery ; Female ; Humans ; Ileum ; diagnostic imaging ; surgery ; Intestinal Fistula ; diagnostic imaging ; Intestinal Obstruction ; diagnostic imaging ; Intestine, Small ; diagnostic imaging ; surgery ; Male ; Middle Aged ; Radiography, Abdominal ; methods ; statistics & numerical data ; Retrospective Studies ; Sensitivity and Specificity ; Tomography, X-Ray Computed ; methods ; statistics & numerical data
3.Digital Subtraction Cystography for Detection of Communicating Holes of Spinal Extradural Arachnoid Cysts.
Kyowon GU ; Jong Won KWON ; Eun Sang KIM
Korean Journal of Radiology 2016;17(1):111-116
OBJECTIVE: The purpose of this study was to demonstrate the usefulness of digital subtraction cystography to identify communicating holes between a spinal extradural arachnoid cyst (SEAC) and the subarachnoid space prior to cyst removal and hole closure. MATERIALS AND METHODS: Six patients with SEAC were enrolled in this retrospective study. Digital subtraction cystography and subsequent CT myelography were performed for every patient. The presence and location of the communicating holes on cystography were documented. We evaluated the MRI characteristics of the cysts, including location, size, and associated spinal cord compression; furthermore, we reviewed cystographic images, CT myelograms, procedural reports, and medical records for analysis. If surgery was performed after cystography, intraoperative findings were compared with preoperative cystography. RESULTS: The location of the communicating hole between the arachnoid cyst and the subarachnoid space was identified by digital subtraction cystography in all cases (n = 6). Surgical resection of SEAC was performed in 4 patients, and intraoperative location of the communicating hole exactly corresponded to the preoperative identification. CONCLUSION: Fluoroscopic-guided cystography for SEAC accurately demonstrates the presence and location of dural defects. Preoperative digital subtraction cystography is useful for detection of a communicating hole between a cyst and the subarachnoid space.
Adult
;
Arachnoid Cysts/*radiography
;
Female
;
Fluoroscopy
;
Humans
;
Image Processing, Computer-Assisted/*methods
;
Magnetic Resonance Imaging
;
Male
;
Middle Aged
;
Radiography, Abdominal
;
Retrospective Studies
;
Spinal Cord Compression/radiography
;
Spinal Cord Diseases/*radiography
;
Tomography, X-Ray Computed
;
Young Adult
4.Neonatal Iliopsoas Abscess: The First Korean Case.
Young Mi HAN ; Ah Young KIM ; Ryoung Kyoung LIM ; Kyung Hee PARK ; Shin Yun BYUN ; Soo Hong KIM ; Hae Young KIM
Journal of Korean Medical Science 2015;30(8):1203-1206
Iliopsoas abscess (IPA) is rare in neonates. We present a case of neonatal IPA that was initially believed to bean inguinal hernia. A 20-day-old male infant was referred to our hospital for herniorrhaphy after a 2-day history of swelling and bluish discoloration of the left inguinal area and leg without limitation of motion. Abdominal and pelvic ultrasonography suggested a femoral hernia, but the anatomy was unclear. Abdominal computed tomography revealed a multi-septated cystic mass extending into the psoas muscle from the lower pole of the left kidney to the femur neck. Broad spectrum antibiotics were initiated, and prompt surgical exploration was planned. After opening the retroperitoneal cavity via an inguinal incision, an IPA was diagnosed and surgically drained. Culture of the abscess fluid detected Staphylococcus aureus, sensitive to methicillin. The patient was discharged without complication on the 17th postoperative day.
Diagnosis, Differential
;
Drainage
;
Hernia, Inguinal/*diagnosis
;
Humans
;
Infant, Newborn
;
Male
;
Psoas Abscess/*diagnosis/*therapy
;
Radiography, Abdominal/methods
;
Rare Diseases
;
Republic of Korea
;
Staphylococcal Infections/*diagnosis/*therapy
;
Tomography, X-Ray Computed/methods
;
Treatment Outcome
5.The utility of the 3D imaging software in the macroscopic rendering of complex gynecologic specimens.
Luca RONCATI ; Beniamino PALMIERI ; Teresa PUSIOL ; Francesco PISCIOLI ; Michele SCIALPI ; Giuseppe BARBOLINI ; Antonio MAIORANA
Journal of Gynecologic Oncology 2015;26(2):168-169
No abstract available.
Abdomen/pathology/surgery
;
Adult
;
Endometrial Neoplasms/complications/*pathology/radiography/surgery
;
Endometriosis/complications/*pathology/radiography/surgery
;
Female
;
Humans
;
Image Enhancement/*methods
;
Imaging, Three-Dimensional/*methods
;
Pelvis/pathology/radiography/surgery
;
Radiography, Abdominal
;
Sarcoma, Endometrial Stromal/complications/*pathology/radiography/surgery
;
*Software
;
Specimen Handling
6.Optimal Timing of Endoscopic Clipping for Determining the Resection Line for Laparoscopy-assisted Distal Gastrectomy.
Ji Young PARK ; Tae Joo JEON ; Won Chang SHIN
The Korean Journal of Gastroenterology 2014;64(2):76-80
BACKGROUND/AIMS: Pre-operative endoscopic clipping for determining the resection line in patients with early gastric cancer has been used safely, and its efficacy has been demonstrated. However, the optimal timing of endoscopic clipping for determining the resection line in early gastric cancer patients undergoing laparoscopy-assisted distal gastrectomy has not been investigated. METHODS: A retrospective analysis of 92 patients with early gastric cancer who underwent gastric resection after endoscopic clipping at Inje University Sanggye Paik Hospital (Seoul, Korea) was performed. We analyzed the clinical and endoscopic features of patients, number of clips, time from clipping to surgery, and number of patients showing detachment of clips from the gastric wall before surgery. Patients were categorized according to the following two groups: group A included patients whose clips were applied within one day before surgery and group B included patients whose clips were applied more than one day before surgery. RESULTS: Of the 92 patients, 56 were included in group A and 36 were included in group B. In 11 patients (12.0%, five in group A and six in group B, p=0.329), the clips were detached from the gastric wall before surgery. The mean time from clipping to surgery did not differ significantly between the detached and non-detached groups (11 patients, mean 4.6+/-4.6 days vs. 81 patients, mean 3.0+/-4.0 days, p=0.227). CONCLUSIONS: The timing of endoscopic clipping for localization of tumors in early gastric cancer patients undergoing gastrectomy is not important for determining the resection line.
Aged
;
Female
;
Gastrectomy/*methods
;
Humans
;
*Laparoscopy
;
Male
;
Middle Aged
;
Neoplasm Staging
;
Preoperative Care
;
Radiography, Abdominal
;
Retrospective Studies
;
Stomach Neoplasms/pathology/*surgery
;
Surgical Instruments
;
Time Factors
7.Clinical and Radiologic Review of Uncommon Cause of Profound Iron Deficiency Anemia: Median Arcuate Ligament Syndrome.
Yasemin GUNDUZ ; Kiyasettin ASIL ; Yakup Ersel AKSOY ; Lacin TATLI AYHAN
Korean Journal of Radiology 2014;15(4):439-442
Median arcuate ligament syndrome is an anatomic and clinical entity characterized by dynamic compression of the proximal celiac artery by the median arcuate ligament, which leads to postprandial epigastric pain, vomiting, and weight loss. These symptoms are usually nonspecific and are easily misdiagnosed as functional dyspepsia, peptic ulcer disease, or gastropathy. In this report, we presented a 72-year-old male patient with celiac artery compression syndrome causing recurrent abdominal pain associated with gastric ulcer and iron deficiency anemia. This association is relatively uncommon and therefore not well determined. In addition, we reported the CT angiography findings and three-dimensional reconstructions of this rare case.
Abdominal Pain/*etiology
;
Aged
;
Anemia, Iron-Deficiency/*etiology
;
Angiography/methods
;
Arterial Occlusive Diseases/radiography
;
Celiac Artery/*abnormalities/radiography
;
Constriction, Pathologic/complications/*radiography
;
Diaphragm
;
Humans
;
Male
;
Recurrence
;
Stomach Ulcer/complications/*radiography
;
Syndrome
;
Tomography, X-Ray Computed
;
Weight Loss
8.Effects of Dual-Energy CT with Non-Linear Blending on Abdominal CT Angiography.
Sulan LI ; Chaoqin WANG ; Xiaochen JIANG ; Ge XU
Korean Journal of Radiology 2014;15(4):430-438
OBJECTIVE: To determine whether non-linear blending technique for arterial-phase dual-energy abdominal CT angiography (CTA) could improve image quality compared to the linear blending technique and conventional 120 kVp imaging. MATERIALS AND METHODS: This study included 118 patients who had accepted dual-energy abdominal CTA in the arterial phase. They were assigned to Sn140/80 kVp protocol (protocol A, n = 40) if body mass index (BMI) < 25 or Sn140/100 kVp protocol (protocol B, n = 41) if BMI > or = 25. Non-linear blending images and linear blending images with a weighting factor of 0.5 in each protocol were generated and compared with the conventional 120 kVp images (protocol C, n = 37). The abdominal vascular enhancements, image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and radiation dose were assessed. Statistical analysis was performed using one-way analysis of variance test, independent t test, Mann-Whitney U test, and Kruskal-Wallis test. RESULTS: Mean vascular attenuation, CNR, SNR and subjective image quality score for the non-linear blending images in each protocol were all higher compared to the corresponding linear blending images and 120 kVp images (p values ranging from < 0.001 to 0.007) except for when compared to non-linear blending images for protocol B and 120 kVp images in CNR and SNR. No significant differences were found in image noise among the three kinds of images and the same kind of images in different protocols, but the lowest radiation dose was shown in protocol A. CONCLUSION: Non-linear blending technique of dual-energy CT can improve the image quality of arterial-phase abdominal CTA, especially with the Sn140/80 kVp scanning.
Adult
;
Aged
;
Angiography/*methods
;
Body Mass Index
;
Female
;
Humans
;
Male
;
Middle Aged
;
Observer Variation
;
Radiation Dosage
;
Radiographic Image Enhancement/methods
;
Radiographic Image Interpretation, Computer-Assisted/*methods
;
Radiography, Abdominal/*methods
;
Signal-To-Noise Ratio
;
Statistics, Nonparametric
;
Tomography, X-Ray Computed/*methods
9.Adaptive Iterative Dose Reduction Algorithm in CT: Effect on Image Quality Compared with Filtered Back Projection in Body Phantoms of Different Sizes.
Milim KIM ; Jeong Min LEE ; Jeong Hee YOON ; Hyoshin SON ; Jin Woo CHOI ; Joon Koo HAN ; Byung Ihn CHOI
Korean Journal of Radiology 2014;15(2):195-204
OBJECTIVE: To evaluate the impact of the adaptive iterative dose reduction (AIDR) three-dimensional (3D) algorithm in CT on noise reduction and the image quality compared to the filtered back projection (FBP) algorithm and to compare the effectiveness of AIDR 3D on noise reduction according to the body habitus using phantoms with different sizes. MATERIALS AND METHODS: Three different-sized phantoms with diameters of 24 cm, 30 cm, and 40 cm were built up using the American College of Radiology CT accreditation phantom and layers of pork belly fat. Each phantom was scanned eight times using different mAs. Images were reconstructed using the FBP and three different strengths of the AIDR 3D. The image noise, the contrast-to-noise ratio (CNR) and the signal-to-noise ratio (SNR) of the phantom were assessed. Two radiologists assessed the image quality of the 4 image sets in consensus. The effectiveness of AIDR 3D on noise reduction compared with FBP were also compared according to the phantom sizes. RESULTS: Adaptive iterative dose reduction 3D significantly reduced the image noise compared with FBP and enhanced the SNR and CNR (p < 0.05) with improved image quality (p < 0.05). When a stronger reconstruction algorithm was used, greater increase of SNR and CNR as well as noise reduction was achieved (p < 0.05). The noise reduction effect of AIDR 3D was significantly greater in the 40-cm phantom than in the 24-cm or 30-cm phantoms (p < 0.05). CONCLUSION: The AIDR 3D algorithm is effective to reduce the image noise as well as to improve the image-quality parameters compared by FBP algorithm, and its effectiveness may increase as the phantom size increases.
*Algorithms
;
Animals
;
Body Size
;
Image Processing, Computer-Assisted/*methods
;
*Phantoms, Imaging/standards
;
Radiation Dosage
;
Signal-To-Noise Ratio
;
Subcutaneous Fat, Abdominal/*radiography
;
Swine
;
Tomography, X-Ray Computed/*methods

Result Analysis
Print
Save
E-mail