1.Validation of a predictive model for platelet transfusion refractoriness in patients with hematological diseases
Xiulan HUANG ; Shuhan YUE ; Qun CAI ; Liqi LU ; Mengzhen HE ; Qiao LEI ; Caoyi LIU ; Jingwei ZHANG
Chinese Journal of Blood Transfusion 2025;38(4):537-545
[Objective] To validate and optimize the platelet transfusion refractoriness (PTR) prediction model for patients with hematological disorders established by our center. [Methods] The data of patients with hematological diseases who received platelet transfusions from December 2021 to December 2022 were used as the training set, and data from January 2023 to December 2023 as the validation set. The validation set data was used to validate the predictive model constructed on the training set. Relevant risk factors for PTR were collected through literature review and preliminary studies。 The patients were divided into effective and ineffective groups according to the corrected count increment (CCI) of platelet counts. Predictive factors were screened using univariate and multivariate logistic regression. The calibration of the model were assessed via calibration curves, while discrimination, accuracy, sensitivity, and specificity were evaluated using receiver operating characteristic (ROC) curves Clinical utility was further analyzed with decision curve analysis (DCA). [Results] The Hosmer-Lemeshow (H-L) goodness-of-fit test for the validation set yielded S: P=0.000, indicating that the original model needs optimization. Baseline comparisons and logistic regression identified the number of red blood cell units (RBCU) and platelet units (PLT-U) transfused as key predictors for the optimized model. The H-L goodness-of-fit test S: P values for the training and validation sets were 0.930 and 0.056, respectively; the ROC areas were 0.793 5 and 0.809 4, specificities 90.95% and 84.21%, sensitivities 59.26% and 70.04%, and accuracies 78.14% and 74.10%, respectively. DCA demonstrated clinical net benefit within a prediction probability threshold range of 0.2-0.8. [Conclusion] Transfusion volumes of RBC-U and PLT-U were inversely associated with PTR in hematological patients. The resulting PTR prediction model exhibits moderate predictive efficacy and clinical benefit.
2.Application of` the variable angle traction method by using clip with dental in super minimally invasive non full thickness resection of early gastric cancer
Qun SHAO ; Xiangdong WANG ; Ke HAN ; Jinping LI ; Zhaobei CAI ; Enqiang LINGHU ; Qianqian CHEN
Chinese Journal of Postgraduates of Medicine 2024;47(3):221-225
Objective:Assisted traction technology is effective in increasing the rate of super minimally invasive surgery (SMIS) in patients with early gastric cancer (EGC), and shortening the operator′s learning curve. We adopt the variable angle traction technique of tissue clamp dental floss as a traction technique in this research.Methods:Patients with early gastric cancer who were treated with SMIS - non full layer resection of EGC were enrolled in the First Medical Center of Chinese PLA General Hospital from January 2022 to June 2023. This research was carried out by experts at the same level. It was divided into two groups: traction and non-traction. Submucosal detachment time (SDT), submucosal detachment rate (SDS), lamina propria exposure, muscularis propria defect (MPD), bleeding during operation, block resection, surgical resection, hand operation expenses, and surgical instruments were recorded.Results:Nine patients adopted variable angle traction, and 9 patients did not. The overall resection rate and curative resection rate of both groups were 100%. The mean SDT time was 28.00 (21.00, 34.00) min in traction group and 56.00 (40.00, 85.00) min in non traction group. And it had statistical significance ( P = 0.005). The SDS was (0.58 ± 0.21) cm 2/min in traction group and (0.23 ± 0.10) cm 2/min in non-traction group. And it had statistical significance ( P<0.05). Exposure of intrinsic muscle layer (IML): 8 cases in the traction group and 6 cases in the non-traction group. Intraoperative IML injury: in the traction group, 8 cases were MPD-0 and 1 case was MPD-Ft; in the non-traction group, 4 cases were MPD-0, 1 case was MPD-Pt, and 4 cases were MPD-Ft. There was no statistical difference between the two groups in terms of intraoperative bleeding, hospitalization expenses, surgical expenses, and the total hospitalization time. There were no serious adverse reactions or outcomes. Conclusions:The variable angle traction method accelerates SDT and SDS for SMIS-non full layer resection of EGC. It has the advantages of the sufficient separation of IML and mucosal layer, the deeper dissection depth, the low injury of IML, low intraoperative bleeding, and no additional medical costs. Therefore, this method can become an auxiliary treatment technology for SMIS.
3.Circular RNAs Involved in The Development of Nasopharyngeal Carcinoma
Si-Cheng ZUO ; Dan WANG ; Yong-Zhen MO ; Yu-Hang LIU ; Jiao-Di CAI ; Can GUO ; Fang XIONG ; Guo-Qun CHEN
Progress in Biochemistry and Biophysics 2024;51(4):809-821
Circular RNAs (circRNAs) are a kind of non-coding RNA (ncRNA) with covalent closed-loop structure. They have attracted more and more attention because of their high stability, evolutionary conservatism, and tissue expression specificity. It has shown that circRNAs are involved in the development of a variety of diseases including malignant tumors recently. Nasopharyngeal carcinoma (NPC) is a malignant tumor that occurs in the nasopharynx and has a unique ethnic and geographical distribution in South China and Southeast Asia. Epstein-Barr virus (EBV) infection is closely related to the development of NPC. Radiotherapy and chemotherapy are the mainstays of treatment for NPC. But tumor recurrence or distant metastasis is the leading cause of death in patients with NPC. Several studies have shown that circRNAs, as gene expression regulators, play an important role in NPC and affect the progression of NPC. This review mainly summarized the research status of abnormally expressed circRNAs in NPC and EBV-encoded circRNAs. We also discussed the possibility of circRNAs as a therapeutic target, diagnostic and prognostic marker for NPC.
4.Study of The Y-STR Multiplex Microfluidic Chip Rapid Amplification System
Dao-Yu WANG ; Qun WAN ; Bin ZHUANG ; Li-Jian ZHAO ; Jun-Ping HAN ; Cai-Xia LI
Progress in Biochemistry and Biophysics 2024;51(3):696-705
ObjectiveAt present, the matching reagents of commercially available rapid DNA instruments based on microfluidics chip technology are autosome short tandem repeat (STR) individual identification reagents. The non-recombining part of the human Y chromosome is widely used in forensic DNA analysis, particularly in cases where standard autosomal DNA profile is uninformative. Y-STR loci are useful markers to identify males and male lineages in forensic practice. In order to achieve rapid and fully integrated detection ofY-STR loci, this study constructed the RTyper Y27 microfluidic chip rapid detection system and validated the performance of this system. MethodsThe system was verified and evaluated by sensitivity, success rate, typing accuracy, peak height balance, sizing precision and accuracy, mock case sample tests, mixture detection ability, and inhibition tolerance. ResultsComplete Y-STR profiles can be obtained when the template amount of DNA standard 9948 was ≥8 ng, the number of blood cards was ≥3 pieces, and the number of oral swab scrapings was≥7 times. The success rate of fully integrated detection was 91.52%, and the concordance rates was 99.74% for 165 testing samples. The success rate of 115 blood spots in these samples was 90.43%, with a typing accuracy of 99.65%, the success rate of 50 buccal swabs was 94%, with a typing accuracy of 99.92%. There was no significant difference in typing accuracy between blood spots and buccal swab samples. The peak height ratio between different fluorescence channels was 89.81%. The standard deviation of allelic ladder for 10 runs was within 0.5 bp. The size differences between allele and corresponding allele in allelic ladder was within 0.5 bp. The maximum precision CV values within and between batches were 0.48% and 0.68%, respectively, which were lower than 15%. These data indicate that the system has good accuracy and precision. The system was capable of accurately typing oral swabs, blood cards, saliva cards, cigarette butts, blood swabs and seminal stains. Complete Y-STR profiles can be obtained and distinguish at the 1∶3 ratio of minor and major contributors in artificial male DNA mixtures. Complete Y-STR genotyping can be obtained under the interference of inhibitors, such as different concentrations of humic acid (50-400 mg/L), indigotin (20-100 nmol/L) and hemoglobin (100-500 μmol/L). ConclusionIn this study, the RTyper Y27 microfluidic chip rapid amplification system is combined with the Quick TargSeq 1.0 integrated system, and the Y-STR profile can be obtained in approximately 2 h. Through a series of verification experiments, the results show that the system has good repeatability, accuracy and stability, can meet the on-site Y-STR detection requirements, and can be used in forensic practice.
5.Phenylethanoid glycosides from Verbenae Herba
Jie LI ; Dan-Yang DONG ; Cai-Ying PENG ; Qin YANG ; Jian-Qun LIU ; Ji-Cheng SHU
Chinese Traditional Patent Medicine 2024;46(1):137-142
AIM To study the phenylethanoid glycosides from Verbenae Herba.METHODS The 80%ethanol extract from Verbenae Herba was isolated and purified by silica gel,Sephadex LH-20,TLC and semi-preparative HPLC,then the structures of obtained compounds were identified by physicochemical properties and spectral data.RESULTS Nine compounds were isolated and identified as verbofficoside A(1),cistanoside D(2),epimeredinoside A(3),verbascoside(4),isoverbascoside(5),cistanoside C(6),cistanoside F(7),decaffeoylacteoside(8),jionoside C(9).CONCLUSION Compound 1 is a new compound.Compounds 3 and 6-9 are isolated from this plant for the first time.
6.Clinical practice of endoscopic ultrasound-guided liver biopsy among the liver transplant recipients
Wei RAO ; Qian LI ; Jia LIU ; Qiuju TIAN ; Qun ZHANG ; Jinzhen CAI ; Man XIE
Chinese Journal of Digestive Endoscopy 2024;41(2):121-126
Objective:To investigate the application of endoscopic ultrasound-guided liver biopsy (EUS-LB) to liver transplant recipients.Methods:In this retrospective cohort study, a total of 12 liver transplant recipients who underwent EUS-LB by the same endoscopist and specimens were diagnosed and reported by the same pathologist due to abnormal liver function or need to be evaluated for graft fibrosis in the Organ Transplantation Center of the Affiliated Hospital of Qingdao University were enrolled into the EUS-LB group from December 2021 to March 2022, meanwhile, a total of 23 patients whose PLB was completed by the same hepatologist and specimens were diagnosed by the same pathologist during the same period were enrolled in the PLB group. Acquisition of liver specimens and postoperative adverse events of the two groups were compared.Results:Patients in both groups were punctured 1-2 times on average, and the median total length of liver specimens in the EUS-LB group was significantly longer than that in the PLB group (61 mm VS 17 mm, Z=11.362, P=0.002). There was no significant difference in the length of the longest liver specimens between the two groups (17.6±6.9 mm VS 13.7±3.5 mm, t=2.382, P=0.086), while the number of liver specimens in the EUS-LB group was more than that in the PLB group (4.8±2.1 VS 2.3±1.2, t=9.271, P=0.001). The number of complete portal tracts was 11.3±4.6 in the EUS-LB group and 6.2±3.3 in the PLB group ( t=8.457, P=0.003). Abdominal pain was the only postoperative adverse event, and only 1 patient in the EUS-LB group had postoperative abdominal pain, which was fewer than that in the PLB group [8.3% (1/12) VS 43.5% (10/23), χ2=4.893, P=0.036]. Conclusion:Compared with PLB, EUS-LB delivers longer liver biopsy specimens with more complete portal tracts in liver transplant recipients, and fewer recipients complain about postoperative pain in EUS-LB group. Therefore, EUS-LB is a safer, more effective and more comfortable liver biopsy method.
7.Effect of hand hygiene intervention on healthcare-associated case infection incidence from 2014 to 2022
Jia-Yan DING ; Rui-Hong SHEN ; Wen-Qin ZHOU ; Ya-Yun YUAN ; Mei HUANG ; Ya YANG ; Bing-Chao CAI ; Hai-Qun BAN ; Xiao-Fang FU
Chinese Journal of Infection Control 2024;23(2):208-213
Objective To observe the effect of multi-modal hand hygiene(HH)intervention on HH compliance,as well as the relationship between HH compliance and the healthcare-associated(HA)case infection incidence.Methods From 2014 to 2022,the infection control team in a tertiary first-class hospital implemented multi-modal HH intervention for health care workers(HCWs).The changing trend of HH monitoring data,the correlation be-tween HH compliance rate and HA case infection incidence were analyzed retrospectively.Results The consump-tion of HH products in the wards showed a stable upward trend;HH compliance rate increased from 64.98%in 2014 to 85.01%in 2022(P<0.001),and HA case infection incidence decreased from 1.21%to 0.83%(P<0.05).HH compliance rate was negatively correlated with HA case infection incidence(r=-0.369,P=0.027).HH compliance rates in different regions and job posts in each quarter were increased(P<0.001).For 5 different HH moments in each quarter,HH compliance rate fluctuated slightly before sterile manipulation and after touching patient;presented rising trend after touching surroundings around patient,and decreased before touching patient and after touching patient's body fluid since 2020(P<0.001).Conclusion Multi-modal HH intervention can im-prove the HH compliance of HCWs,improving their HH awareness is conducive to reducing HA case infection incidence.
8.Chinese expert consensus on blood support mode and blood transfusion strategies for emergency treatment of severe trauma patients (version 2024)
Yao LU ; Yang LI ; Leiying ZHANG ; Hao TANG ; Huidan JING ; Yaoli WANG ; Xiangzhi JIA ; Li BA ; Maohong BIAN ; Dan CAI ; Hui CAI ; Xiaohong CAI ; Zhanshan ZHA ; Bingyu CHEN ; Daqing CHEN ; Feng CHEN ; Guoan CHEN ; Haiming CHEN ; Jing CHEN ; Min CHEN ; Qing CHEN ; Shu CHEN ; Xi CHEN ; Jinfeng CHENG ; Xiaoling CHU ; Hongwang CUI ; Xin CUI ; Zhen DA ; Ying DAI ; Surong DENG ; Weiqun DONG ; Weimin FAN ; Ke FENG ; Danhui FU ; Yongshui FU ; Qi FU ; Xuemei FU ; Jia GAN ; Xinyu GAN ; Wei GAO ; Huaizheng GONG ; Rong GUI ; Geng GUO ; Ning HAN ; Yiwen HAO ; Wubing HE ; Qiang HONG ; Ruiqin HOU ; Wei HOU ; Jie HU ; Peiyang HU ; Xi HU ; Xiaoyu HU ; Guangbin HUANG ; Jie HUANG ; Xiangyan HUANG ; Yuanshuai HUANG ; Shouyong HUN ; Xuebing JIANG ; Ping JIN ; Dong LAI ; Aiping LE ; Hongmei LI ; Bijuan LI ; Cuiying LI ; Daihong LI ; Haihong LI ; He LI ; Hui LI ; Jianping LI ; Ning LI ; Xiying LI ; Xiangmin LI ; Xiaofei LI ; Xiaojuan LI ; Zhiqiang LI ; Zhongjun LI ; Zunyan LI ; Huaqin LIANG ; Xiaohua LIANG ; Dongfa LIAO ; Qun LIAO ; Yan LIAO ; Jiajin LIN ; Chunxia LIU ; Fenghua LIU ; Peixian LIU ; Tiemei LIU ; Xiaoxin LIU ; Zhiwei LIU ; Zhongdi LIU ; Hua LU ; Jianfeng LUAN ; Jianjun LUO ; Qun LUO ; Dingfeng LYU ; Qi LYU ; Xianping LYU ; Aijun MA ; Liqiang MA ; Shuxuan MA ; Xainjun MA ; Xiaogang MA ; Xiaoli MA ; Guoqing MAO ; Shijie MU ; Shaolin NIE ; Shujuan OUYANG ; Xilin OUYANG ; Chunqiu PAN ; Jian PAN ; Xiaohua PAN ; Lei PENG ; Tao PENG ; Baohua QIAN ; Shu QIAO ; Li QIN ; Ying REN ; Zhaoqi REN ; Ruiming RONG ; Changshan SU ; Mingwei SUN ; Wenwu SUN ; Zhenwei SUN ; Haiping TANG ; Xiaofeng TANG ; Changjiu TANG ; Cuihua TAO ; Zhibin TIAN ; Juan WANG ; Baoyan WANG ; Chunyan WANG ; Gefei WANG ; Haiyan WANG ; Hongjie WANG ; Peng WANG ; Pengli WANG ; Qiushi WANG ; Xiaoning WANG ; Xinhua WANG ; Xuefeng WANG ; Yong WANG ; Yongjun WANG ; Yuanjie WANG ; Zhihua WANG ; Shaojun WEI ; Yaming WEI ; Jianbo WEN ; Jun WEN ; Jiang WU ; Jufeng WU ; Aijun XIA ; Fei XIA ; Rong XIA ; Jue XIE ; Yanchao XING ; Yan XIONG ; Feng XU ; Yongzhu XU ; Yongan XU ; Yonghe YAN ; Beizhan YAN ; Jiang YANG ; Jiangcun YANG ; Jun YANG ; Xinwen YANG ; Yongyi YANG ; Chunyan YAO ; Mingliang YE ; Changlin YIN ; Ming YIN ; Wen YIN ; Lianling YU ; Shuhong YU ; Zebo YU ; Yigang YU ; Anyong YU ; Hong YUAN ; Yi YUAN ; Chan ZHANG ; Jinjun ZHANG ; Jun ZHANG ; Kai ZHANG ; Leibing ZHANG ; Quan ZHANG ; Rongjiang ZHANG ; Sanming ZHANG ; Shengji ZHANG ; Shuo ZHANG ; Wei ZHANG ; Weidong ZHANG ; Xi ZHANG ; Xingwen ZHANG ; Guixi ZHANG ; Xiaojun ZHANG ; Guoqing ZHAO ; Jianpeng ZHAO ; Shuming ZHAO ; Beibei ZHENG ; Shangen ZHENG ; Huayou ZHOU ; Jicheng ZHOU ; Lihong ZHOU ; Mou ZHOU ; Xiaoyu ZHOU ; Xuelian ZHOU ; Yuan ZHOU ; Zheng ZHOU ; Zuhuang ZHOU ; Haiyan ZHU ; Peiyuan ZHU ; Changju ZHU ; Lili ZHU ; Zhengguo WANG ; Jianxin JIANG ; Deqing WANG ; Jiongcai LAN ; Quanli WANG ; Yang YU ; Lianyang ZHANG ; Aiqing WEN
Chinese Journal of Trauma 2024;40(10):865-881
Patients with severe trauma require an extremely timely treatment and transfusion plays an irreplaceable role in the emergency treatment of such patients. An increasing number of evidence-based medicinal evidences and clinical practices suggest that patients with severe traumatic bleeding benefit from early transfusion of low-titer group O whole blood or hemostatic resuscitation with red blood cells, plasma and platelet of a balanced ratio. However, the current domestic mode of blood supply cannot fully meet the requirements of timely and effective blood transfusion for emergency treatment of patients with severe trauma in clinical practice. In order to solve the key problems in blood supply and blood transfusion strategies for emergency treatment of severe trauma, Branch of Clinical Transfusion Medicine of Chinese Medical Association, Group for Trauma Emergency Care and Multiple Injuries of Trauma Branch of Chinese Medical Association, Young Scholar Group of Disaster Medicine Branch of Chinese Medical Association organized domestic experts of blood transfusion medicine and trauma treatment to jointly formulate Chinese expert consensus on blood support mode and blood transfusion strategies for emergency treatment of severe trauma patients ( version 2024). Based on the evidence-based medical evidence and Delphi method of expert consultation and voting, 10 recommendations were put forward from two aspects of blood support mode and transfusion strategies, aiming to provide a reference for transfusion resuscitation in the emergency treatment of severe trauma and further improve the success rate of treatment of patients with severe trauma.
9.Potential profile analysis and influencing factors of self-management in prediabetic patients
Huimin DING ; Limin DAI ; Dongqing CAI ; Qun YANG
Chinese Journal of Nursing 2024;59(9):1057-1064
Objective To explore the potential categories of self-management behavior in prediabetes patients and analyze the influencing factors of different potential categories.Methods A convenient sampling method was used to select pre-diabetic patients treated in physical examination centers and endocrinology outpatient clinics in 2 tertiary A hospitals in Jiangsu Province from September 2022 to June 2023.General data questionnaire,Prediabetic Disease Knowledge Questionnaire,Prediabetes Self-management Scale,Diabetes Self-efficacy Scale and Social Support Rating Scale were used for investigation.Results A total of 445 subjects were included in this study,with an average age of(44.92±4.98)years.4 potential categories of self-management behavior were identified,namely low self-management(16.4%),static self-management(19.1%),dynamic self-management(25.6%)and high self-management(38.9%).Occupational status,marital status,family per capita monthly income,family history of diabetes,disease knowledge,self-efficacy and social support were the influencing factors of self-management behavior in prediabetes patients(P<0.05).Conclusion There are significant category characteristics of self-management behavior in patients with prediabetes.Medical staff can identify the category characteristics and influencing factors early,and provide bases for medical staff to formulate targeted clinical intervention measures to help patients improve their self-management level.
10.Value of 18F-FAPI PET/CT in evaluating early-stage of liver graft fibrosis in adult liver transplantation recipients
Youwei ZHAO ; Xiaohan FANG ; Qiuju TIAN ; Qun ZHANG ; Man XIE ; Guangjie YANG ; Jinzhen CAI ; Zhenguang WANG ; Wei RAO
Chinese Journal of Nuclear Medicine and Molecular Imaging 2024;44(7):385-389
Objective:To explore the value of 18F-fibroblast activation protein inhibitor (FAPI) PET/CT in the assessment of early-stage graft fibrosis (S1-S2) after liver transplantation (LT). Methods:From November 2021 to April 2022, 17 adult liver transplant recipients (12 males and 5 females; age (52.6±7.9) years) in the Affiliated Hospital of Qingdao University were enrolled retrospectively in this study. All 17 patients received laboratory examinations, FibroScan, 18F-FAPI PET/CT and liver biopsy. According to the Scheuer scoring system, hepatic tissue was divided into no fibrosis (S0) and early fibrosis (S1-S2). Independent-sample t test was used to compare SUV max between two groups, and Mann-Whitney U test was used to compare liver stiffness measurement (LSM). ROC curve analysis was used to evaluate the diagnostic efficacy of LSM and SUV max in the early fibrosis of liver grafts. Delong test was used to compare the difference of AUCs. Results:Among 17 adult LT recipients, 11 were in stage S0, 5 were in stage S1, and 1 was in stage S2. There were significant differences in LSM and SUV max between no fibrosis group and early fibrosis group (LSM: 5.4(4.7, 6.6) vs 12.9(5.6, 19.9) kPa, z=-2.01, P=0.044; SUV max: 1.7±0.8 vs 3.9±1.6, t=-3.14, P=0.019). The threshold value of LSM in predicting early-stage graft fibrosis was 8.2 kPa and the AUC was 0.80 (95% CI: 0.54-0.95), which was 2.0 and 0.92 (95% CI: 0.78-1.00) for SUV max respectively. There was no significant difference in AUC between the two tools ( z=0.80, P=0.421). Conclusion:18F-FAPI PET/CT can precisely evaluate the early fibrosis of allografts, with the similar diagnostic efficacy with FibroScan (LSM), which is expected to be a new non-invasive diagnostic tool for predicting the early-stage of graft liver fibrosis.

Result Analysis
Print
Save
E-mail