1.Effect of type of carrier material on the in vitro properties of solid dispersions of progesterone
Jing-nan QUAN ; Yi CHENG ; Jing-yu ZHOU ; Meng LI ; Zeng-ming WANG ; Nan LIU ; Zi-ming ZHAO ; Hui ZHANG ; Ai-ping ZHENG
Acta Pharmaceutica Sinica 2024;59(3):735-742
This study investigated the effect of different carrier materials on the
2.Bioequivalence study of entecavir tablets in healthy Chinese subjects under fasting condition
Juan ZHANG ; Meng WANG ; Ming HUANG ; Ji WANG ; Quan-Ying ZHANG
The Chinese Journal of Clinical Pharmacology 2024;40(9):1311-1315
Objective To evaluate the pharmacokinetics and bioequivalence of two entecavir tablets under fasting condition in Chinese healthy volunteers.Methods A single oral dose of 0.50 mg entecavir test and reference formulations was given to 30 healthy volunteers in the fasting state according to two randomized open-label crossover clinical studies.Plasma concentrations were determined by HPLC-MS/MS after deproteinized with acetonitrile.The pharmacokinetic parameters were calculated by WinNonlin 6.4.The bioequivalence of entecavir tablets test and its reference in the fasting state were evaluated respectively.Results In the fasting state,the main pharmacokinetic parameters of entecavir were as follows:Cmax were(4 390.00±1 257.56)and(4 421.00±1 239.55)pg·mL-1;tmax were 0.67(0.33,2.00)and 0.75(0.50,2.00)h;t1/2were(29.71±14.50)and(35.43±16.58)h,AUC0_72h were(12 252.43±2 671.28)and(12 063.43±2 151.50)pg·mL-1·h.The 90%confidence intervals of the mean ratio of Cmax,AUC0-72h and AUC0-∞ of the text and reference formulations were all within the equivalent interval of 80.00%-125.00%.Conclusion The entecavir tablets test and its reference were bioequivalent in the fasting state.
3.Drug metabolism and excretion of14Cbirociclib in Chinese male healthy subjects
Quan-Kun ZHUANG ; Hui-Rong FAN ; Shi-Qi DONG ; Bin-Ke FAN ; Ming-Ming LIU ; Ling-Mei XU ; Li WANG ; Xue-Mei LIU ; Fang HOU
The Chinese Journal of Clinical Pharmacology 2024;40(14):2118-2123
Objective To evaluate the characteristics of the mass balance and pharmacokinetics of[14 C]birociclib in Chinese male healthy volunteers after a single oral administration.Methods This study used a 14 C labeled method to investigate the mass balance and biological transformation of birociclib in human.Subjects were given a single oral dose of 360 mg/50 pCi of[14 C]birociclib suspension after meals.The blood,urine,and fecal samples were collected at specified time points/intervals after administration.The radiation levels of 14 C labeled birociclib-related compounds in the blood,plasma,urine,and feces were analyzed using liquid scintillation counting.In addition,a combination of high-performance liquid chromatography and on-line/off-line isotope detectors was used to obtain radioactive isotope metabolite spectra of plasma,urine,and fecal samples,and high-resolution mass spectrometry was used to identify the main metabolites.Results A total of 6 healthy male subjects were enrolled in this study.The median peak time of radioactive components in plasma was 5.00 h and the average terminal elimination half-life was 43.70 h after administration.The radioactive components were basically excreted and cleared from the body within 288.00 hours after administration,and average cumulative recovery rate of radioactive drugs was(94.10±8.19)%.The radioactive drugs were mainly excreted through feces,accounting for(84.60±7.10)%of the dose of radioactive drugs administered.Urine was the secondary excretory pathway,accounting for 9.41%of the dose of radioactive drugs administered.Metabolic analysis indicated that the prototype drug was the main radioactive components in plasma samples.The main metabolites in plasma were RM4(XZP-5286),RM6(XZP-3584),and RM7(XZP-5736).The drugs were mainly cleared from the body in the form of prototype drugs and metabolites.In addition to prototype drugs,a total of 9 metabolites were identified and analyzed in plasma,urine,and fecal samples,all of which were phase 1 metabolites.The main metabolic and clearance pathways of drugs in the body were deethylation,diisopropylat ion,oxidation,etc.Conclusion After a single oral administration of[14C]birociclib suspension to healthy subjects,it was mainly cleared from the body in the form of prototype drugs and metabolites,with feces as the main excretory pathway and urine as the secondary excretory pathway.Drugs mainly undergo metabolic reactions in the body,such as deethylation,diisopropylation,and oxidation.The subjects were well tolerance after administration.
4.Cloning and interacted protein identification of AGL12 gene from Lonicera macranthoides
Li-jun LONG ; Hui-jie ZENG ; Zhong-quan QIAO ; Xiao-ming WANG ; Chang-zhu LI ; Si-si LIU ; Ying-zi MA
Acta Pharmaceutica Sinica 2024;59(5):1458-1466
MADS-box protein family are important transcriptional regulatory factors in plant growth and development. The
5.A controlled clinical study of vertebroplasty for the treatment of osteoporotic vertebral compression fractures after self-made spinal positioner and manual reduction
Da WANG ; Shang-Quan WANG ; Ling-Hui LI ; Ming CHEN ; Yong-Kang FENG ; Ming-Yang CAI
China Journal of Orthopaedics and Traumatology 2024;37(6):538-545
Objective To explore clinical effect of manipulation reduction combined with vertebral plasty on osteoporotic compression fractures(OVCFs).Methods Totally 61 patients with OVCFs treated from January 2022 to March 2024 were randomly divided into self-made spinal locator positioning with manipulation reduction group(treatment group)and traditional Kirchner positioning group(control group).There were 30 patients in treatment group,including 4 males and 26 females,aged from 61 to 87 years old with an average of(73.61±7.17)years old;body mass index(BMI)ranged from 15.24 to 28.89 kg·m-2 with an average of(23.90±3.20)kg·m-2;bone mineral density T value ranged from-4.90 to-2.50 SD with an avergae of(-3.43±0.75)SD;fracture to operation time was 6.50(4.00,10.25)d;10 patients were grade Ⅰ,13 patients were grade Ⅱ,and 7 patients were grade Ⅲ according to Genant classification of fracture compression.There were 31 patients in control group,in-cluding 7 males and 24 females,aged from 61 to 89 years old with an average of(73.63±8.77)years old;BMI ranged from 18.43 to 27.06 kg·m-2 with an average of(23.67±2.35)kg·m-2;bone mineral density T value ranged from-4.60 to-2.50 SD with an avergae of(-3.30±0.68)SD;fracture to operation time was 6.00(3.00,8.00)d;1l patients were grade Ⅰ,9 patients were grade Ⅱ,and 11 patients were grade Ⅲ according to Genant classification of fracture compression.The puncture times,X-ray fluoroscopy times and puncture time between two groups were observed and compared.Visual analogue scale(VAS),Japanese Orthopaedic Association(JOA)and timed up and go test(TUGT)were observed and compared before operation,3 d and 1 month after operation.Results All patients were followed up for 1 to 3 months with an average of(2.10±0.80)months.Puncture times,X-ray fluorosecopy times and puncture time in treatment group were 5.00(4.00,6.00)times,(29.53±5.89)times and 14.83(12.42,21.20)min,respectively,while those in control group were 7.00(6.00,8.00)times,(34.58±5.33)times,22.19(17.33,27.01)min,treatment group was better than those of control group(P<0.05).There were no significant differences in preoperative VAS,JOA and TUGT between two groups(P>0.05).VAS,JOA and TUGT in both groups were sig-nificantly improved after opeation(P<0.05).On the third day after operation,JOA score of treatment group was 23.00(20.75,25.00),which was higher than that of control group 20.00(19.00,23.00)(P<0.05).TUGT of treatment group was 6.26(5.86,6.57)s,which was better than that of control group 6.90(6.80,7.14)s(P<0.05).Bone cement leakage occurred with 1 patient in treatment group and 2 patients in control group.Conclusion The optimal scheme of self-made spinal locators for lo-cating descending verteboplasty combined with traditional Chinese medicine reduction manipulation for OVCF patients could reduce the number of intraoperative puncture times,shorten puncture times and reduce number of X-ray fluoroscopy times,and have advantages over the simple positioning of Kirschn's needle in restoring short-term lumbar function and standing and walk-ing ability of postoperative patients.
6.Early gait analysis after total knee arthroplasty based on artificial intelligence dynamic image recognition
Ming ZHANG ; Ya-Nan SUI ; Cheng WANG ; Hao-Chong ZHANG ; Zhi-Wei CAI ; Quan-Lei ZHANG ; Yu ZHANG ; Tian-Tian XIA ; Xiao-Ran ZU ; Yi-Jian HUANG ; Cong-Shu HUANG ; Xiang LI
China Journal of Orthopaedics and Traumatology 2024;37(9):855-861
Objective To explore early postoperative gait characteristics and clinical outcomes after total knee arthroplasty(TKA).Methods From February 2023 to July 2023,26 patients with unilateral knee osteoarthritis(KOA)were treated with TKA,including 4 males and 22 females,aged from 57 to 85 years old with an average of(67.58±6.49)years old;body mass in-dex(BMI)ranged from 18.83 to 38.28 kg·m-2 with an average of(26.43±4.15)kg·m-2;14 patients on the left side,12 pa-tients on the right side;according to Kellgren-Lawrence(K-L)classification,6 patients with grade Ⅲ and 20 patients with grade Ⅳ;the courses of disease ranged from 1 to 14 years with an average of(5.54±3.29)years.Images and videos of standing up and walking,walking side shot,squatting and supine kneeling were taken with smart phones before operation and 6 weeks after operation.The human posture estimation framework OpenPose were used to analyze stride frequency,step length,step length,step speed,active knee knee bending angle,stride length,double support phase time,as well as maximum hip flexion angle and maximum knee bending angle on squatting position.Western Ontario and McMaster Universities(WOMAC)arthritis index and Knee Society Score(KSS)were used to evaluate clinical efficacy of knee joint.Results All patients were followed up for 5 to 7 weeks with an average of(6.00±0.57)weeks.The total score of WOMAC decreased from(64.85±11.54)before op-eration to(45.81±7.91)at 6 weeks after operation(P<0.001).The total KSS was increased from(101.19±9.58)before opera-tion to(125.50±10.32)at 6 weeks after operation(P<0.001).The gait speed,stride frequency and stride length of the affected side before operation were(0.32±0.10)m·s-1,(96.35±24.18)steps·min-1,(0.72±0.14)m,respectively;and increased to(0.48±0.11)m·s 1,(104.20±22.53)steps·min-1,(0.79±0.10)m at 6 weeks after operation(P<0.05).The lower limb support time and active knee bending angle decreased from(0.31±0.38)sand(125.21±11.64)° before operation to(0.11±0.04)s and(120.01±13.35)° at 6 weeks after operation(P<0.05).Eleven patients could able to complete squat before operation,13 patients could able to complete at 6 weeks after operation,and 9 patients could able to complete both before operation and 6 weeks after operation.In 9 patients,the maximum bending angle of crouching position was increased from 76.29° to 124.11° before operation to 91.35° to 134.12° at 6 weeks after operation,and the maximum bending angle of hip was increased from 103.70° to 147.25° before operation to 118.61° to 149.48° at 6 weeks after operation.Conclusion Gait analysis technology based on artificial intelligence image recognition is a safe and effective method to quantitatively identify the changes of pa-tients'gait.Knee pain of KOA was relieved and the function was improved,the supporting ability of the affected limb was im-proved after TKA,and the patient's stride frequency,stride length and stride speed were improved,and the overall movement rhythm of both lower limbs are more coordinated.
7.Percutaneous balloon mitral valvuloplasty guided by intracardiac echocardiography:a report of two cases
De-Jian LI ; Song CHEN ; Chao XU ; Xue JIANG ; Bo WANG ; Jian-Fei FENG ; Dong-Bang SONG ; Guo-Hui ZHANG ; Ming-Quan WANG ; Wei-Min WANG ; Da-Dong ZHANG
Chinese Journal of Interventional Cardiology 2024;32(5):295-297
For the past 30 years,percutaneous balloon mitral valve dilatation has been performed under the guidance of X-rays and bedside ultrasound.However,there are still some cases of mitral valve stenosis in the large atrium where balloon dilation failed.Intraperitoneal ultrasound-guided percutaneous balloon mitral valve plasty is accurate and feasible,which can reduce the occurrence of complications and improve the success rate of such elderly complex cases.Two patients with severe mitral stenosis underwent percutaneous balloon mitral valve plasty guided by intracardiac ultrasound.The operations were successful without any complications,which can provide reference for clinical treatment of mitral stenosis.
8.Mechanism about LMP1 of EB Virus Promoting Plasma Blast Diffe-rentiation of DLBCL Cell via mTORC1
Jing-Jing GAO ; Xiong-Peng ZHU ; Ming-Quan WANG ; Xing-Zhi LIN ; Yan-Ling ZHUANG ; Hong-Jun LIN
Journal of Experimental Hematology 2024;32(1):219-224
Objective:To investigate possible mechanism on protien LMP1 expressed by EBV inducing plasmablast differentiation of DLBCL cell via the mTORC1 pathway.Methods:The expression levels of LMP1 protein,CD38 and the phosphorylation levels of p70S6K in EBV+and EBV-DLBCL cell lines were detected by Western blot.Cell lines overexpressing LMP1 gene stablely were constructed and LMP1 gene was silenced by RNAi.The expression of LMP1 gene was verified by RT-qPCR.The expression levels of LMP1 and CD38 and the phosphorylation levels of p70S6K in each group were detected by Western blot.Results:Compared with EBV-DLBCL cells,the expression of LMP1 was detected on EBV+DLBCL cells(P=0.0008),EBV+DLBCL cells had higher phosphorylation levels of p70S6K(P=0.0072)and expression levels of CD38(P=0.0091).Compared with vector group,the cells of LMP1OE group had higher expression levels of LMP1 and CD38(P=0.0353;P<0.0001),meanwhile molecular p70S6K was phosphorylated much more(P=0.0065);expression of LMP1 mRNA was verified(P<0.0001).Compared with si-NC group,expression level of LMP1 protein(P=0.0129)was not detected and phosphorylated p70S6K disappeared of LMP1KO group(P=0.0228);meanwhile,expression of CD38 decreased,although there was no significant difference(P=0.2377).Conclusion:LMP1 promotes DLBCL cells plasmablast differentiation via activating mTORC1 signal pathway.
9.Mechanism of Shenkang injection in treatment of renal fibrosis based on bioinformatics and in vitro experimental verification
Gao-Quan MENG ; Ming-Liang ZHANG ; Xiao-Fei CHEN ; Xiao-Yan WANG ; Wei-Xia LI ; Dai ZHANG ; Lu JIANG ; Ming-Ge LI ; Xiao-Shuai ZHANG ; Wei-Ting MENG ; Bing HAN ; Jin-Fa TANG
Chinese Pharmacological Bulletin 2024;40(10):1953-1962
Aim To explore the mechanism and mate-rial basis of Shenkang injection(SKI)in the treatment of renal fibrosis(RF)by bioinformatics and in vitro experiments.Methods The differentially expressed genes of RF were screened by GEO database.With the help of CMAP database,based on the similarity princi-ple of gene expression profile,the drugs that regulated RF were repositioned,and then the components of SKI potential treatment RF were screened by molecular fin-gerprint similarity analysis.At the same time,the core targets and pathways of SKI regulating RF were predic-ted based on network pharmacology.Finally,it was verified by molecular docking and cell experiments.Results Based on the GEO database,two RF-related data sets were screened,and CMAP was relocated to three common RF therapeutic drugs(saracatinib,da-satinib,pp-2).Molecular fingerprint similarity analysis showed that RF therapeutic drugs had high structural similarity with five SKI components such as salvianolic acid B and hydroxysafflor yellow A.Molecular docking results showed that salvianolic acid B,hydroxysafflor yellow A and other components had good binding abili-ty with MMP1 and MMP13,which were the core targets of SKI-regulated potential treatment of RF.Network pharmacology analysis suggested that the core targets of SKI were mainly enriched in signaling pathways such as Relaxin and AGE-RAGE.Cell experiments showed that SKI could significantly reduce the mRNA expres-sion levels of AGER,NFKB1,COL1A1,SERPINE1,VEGFC in AGE-RAGE signaling pathway and MMP1 and MMP13 in Relaxin signaling pathway in RF model cells,and significantly increase the mRNA expression level of RXFP1.Conclusions SKI can play a role in the treatment of RF by regulating Relaxin and AGE-RAGE signaling pathways,and its material basis may be salvianolic acid B,hydroxysafflor yellow A and other components.
10.Influencing factors and prediction of stroke-related pneumonia in patients with acute ischemic stroke and type 2 diabetes
Ming LU ; Mengyin HAN ; Quan WANG
Journal of Clinical Neurology 2024;37(5):360-364
Objective To explore the influencing factors of stroke-associated pneumonia(SAP)in patients with acute ischemic stroke(AIS)complicated with type 2 diabetes mellitus(T2DM)and to establish a related predictive model.Methods A total of 125 patients with AIS complicated with T2DM from September 2021 to September 2023 were divided into SAP group(n=28)and non-SAP group(n=97)according to the diagnostic criteria of SAP.The clinical data of two groups of patients were collected,the etiology of SAP group was analyzed,and the influencing factors of SAP were discussed.The related predictive model was established,and the ROC curve was used to test the application value of the model.Results The main pathogens in SAP group were gram-negative bacilli(73.9%).There were significant differences in disturbance of consciousness,indwelling gastric tube,acid inhibitor,glycosylated hemoglobin,fasting blood glucose,albumin,D-dimer,neutrophil/lymphocyte ratio(NLR),platelet/lymphocyte ratio between SAP group and non-SAP group(all P<0.05).Logistic analysis showed that disturbance of consciousness,indwelling gastric tube,use of acid suppressants,glycosylated hemoglobin and NLR were independent risk factors for SAP(all P<0.05).ROC analysis showed that the predictive model predicted the area under the SAP curve was 0.948(95%CI:0.911-0.986).The best cutoff value was 0.217,the sensitivity was 0.893 and the specificity was 0.866.Conclusions Gram-negative bacilli are the main pathogens of SAP in AIS patients with T2DM.Disturbance of consciousness,indwelling gastric tube,use of acid suppressants,glycosylated hemoglobin and NLR are independent risk factors for SAP.The model based on these factors has high predictive value.

Result Analysis
Print
Save
E-mail