1.Application of Statistical Process Control in Evaluation of Performance for Beam-matched Medical Electron Linacs.
Qing XIAO ; Guangjun LI ; Xiangbin ZHANG ; Sen BAI
Chinese Journal of Medical Instrumentation 2021;45(1):109-113
Clinically, beam matching can greatly improve the flexibility and efficiency of treating patients between different medical electron linacs. However, in addition to the regular quality assurance (QA) test of the machine performance of linacs, there is still a lack of comprehensive evaluation of the clinical radiotherapy performance of beam-matched linacs. In this paper, the performance of volumetric modulated arc therapy (VMAT) between three closely matched linacs was evaluated by statistical process control (SPC) technology. It was found that the average and median γ passing rates of the VMAT QA processes of the three linacs had little difference, but the process capability levels were at three different levels. The results show that SPC technology can effectively evaluate the performance of beam matching for medical electron linacs, improve the patient-specific VMAT QA processes, and guide clinical decision-making.
Electrons
;
Particle Accelerators
;
Quality Assurance, Health Care
;
Radiotherapy Dosage
;
Radiotherapy Planning, Computer-Assisted
;
Radiotherapy, Intensity-Modulated
2.Dosimetric verification of stereotactic body radiotherapy treatment plan via ArcCHECK-3DVH system.
Shulin CHENG ; Dongyong SHAN ; Ke CAO ; Shizhen BIN ; Junjun ZHANG ; Tian TANG
Journal of Central South University(Medical Sciences) 2021;46(5):475-480
OBJECTIVES:
To study the feasibility of ArcCHECK-3DVH system in dosimetric verification for stereotactic body radiaotherapy (SBRT) with flattening filter free (FFF) model.
METHODS:
SBRT treatment plans for 57 patients were introduced into ArcCHECK phantom and recalculated. The calculated dose distribution of treatment planning system and the measured dose distribution of ArcCHECK phantom were compared by γ analysis. Then the 3 dimensional dose distribution of target and organs at risk was reconstructed by 3DVH software. The reconstructed dose and calculated dose with treatment planning system (TPS) were compared, and the dose volume γ pass rate and deviation of dose volume parameters to the target and organs at risk were quantitatively valuated.
RESULTS:
Based on the threshold criteria (3%, 3 mm, 10%), namely the deviation of measuring points between the planned value and the measured value was less than 3%, and the proportion of points with similar values in the plane or sphere with the center of the point and the radius of 3 mm was 10%, the relative and absolute dose pass rates of SBRT treatment plans in ArcCHECK system via γ analysis were greater than 95%. Based on the stricter threshold criteria (2%, 2 mm, 10%), the relative and absolute dose pass rates of SBRT treatment plan in ArcCHECK system via γ analysis were about 93%. In 3DVH dose verification, the γ pass rate of target and organs at risk was exceed 97%, and the deviations in 3DVH of the target and organs at risk were less than ±5%.
CONCLUSIONS
The ArcCHECK-3DVH system in dose verification can provide more comprehensive dose distribution information to reasonably evaluate the SBRT plan, with more significance for guiding clinical treatment.
Humans
;
Phantoms, Imaging
;
Quality Assurance, Health Care
;
Radiometry
;
Radiosurgery
;
Radiotherapy Dosage
;
Radiotherapy Planning, Computer-Assisted
;
Radiotherapy, Intensity-Modulated
3.A comparison of perioperative outcomes between extraperitoneal robotic single-port and multiport radical prostatectomy with the da Vinci Si Surgical System.
Guan-Qun JU ; Zhi-Jun WANG ; Jia-Zi SHI ; Zong-Qin ZHANG ; Zhen-Jie WU ; Lei YIN ; Bing LIU ; Lin-Hui WANG ; Dong-Liang XU
Asian Journal of Andrology 2021;23(6):640-647
To evaluate outcomes between extraperitoneal robotic single-port radical prostatectomy (epR-spRP) and extraperitoneal robotic multiport radical prostatectomy (epR-mpRP) performed with the da Vinci Si Surgical System, comparison was performed between 30 single-port (SP group) and 26 multiport (MP group) cases. Comparisons included operative time, estimated blood loss (EBL), hospital stay, peritoneal violation, pain scores, scar satisfaction, continence, and erectile function. The median operation time and EBL were not different between the two groups. In the SP group, the median operation time of the first 10 patients was obviously longer than that of the latter 20 patients (P < 0.001). The median postoperative hospital stay in the SP group was shorter than that in the MP group (P < 0.001). The rate of peritoneal damage in the SP group was less than that in the MP group (P = 0.017). The pain score and overall need for pain medications in the SP group were lower than those in the MP group (P < 0.001 and P = 0.015, respectively). Patients in the SP group were more satisfied with their scars than those in the MP group 3 months postoperatively (P = 0.007). At 3 months, the cancer control, recovery of erectile function, and urinary continence rates were similar between the two groups. It is safe and feasible to perform epR-spRP using the da Vinci Si surgical system. Therefore, epR-spRP can be a treatment option for localized prostate cancer. Although epR-spRP still has a learning curve, it has advantages for postoperative pain and self-assessed cosmesis. In the absence of the single-port robotic surgery platform, we can still provide minimally invasive surgery for patients.
Aged
;
Blood Loss, Surgical/statistics & numerical data*
;
Humans
;
Male
;
Middle Aged
;
Outcome Assessment, Health Care/statistics & numerical data*
;
Perioperative Medicine/statistics & numerical data*
;
Prostatectomy/methods*
;
Prostatic Neoplasms/surgery*
;
Quality Assurance, Health Care/statistics & numerical data*
;
Robotic Surgical Procedures/statistics & numerical data*
4.Preliminary study on monitoring patient-specific volumetric modulated arc therapy quality assurance process with statistical process control methodology on the basis of TG-218 report.
Qing XIAO ; Guangjun LI ; Zhibin LI ; Xiangbin ZHANG ; Guyu DAI ; Sen BAI
Journal of Biomedical Engineering 2020;37(5):842-847
Patient-specific volumetric modulated arc therapy (VMAT) quality assurance (QA) process is an important component of the implementation process of clinical radiotherapy. The tolerance limit and action limit of discrepancies between the calculated dose and the delivered radiation dose are the key parts of the VMAT QA processes as recognized by the AAPM TG-218 report, however, there is no unified standard for these two values among radiotherapy centers. In this study, based on the operational recommendations given in the AAPM TG-218 report, treatment site-specific tolerance limits and action limits of gamma pass rate in VMAT QA processes when using ArcCHECK for dose verification were established by statistical process control (SPC) methodology. The tolerance limit and action limit were calculated based on the first 25 in-control VMAT QA for each site. The individual control charts were drawn to continuously monitor the VMAT QA process with 287 VMAT plans and analyze the causes of VMAT QA out of control. The tolerance limits for brain, head and neck, abdomen and pelvic VMAT QA processes were 94.56%, 94.68%, 94.34%, and 92.97%, respectively, and the action limits were 93.82%, 92.54%, 93.23%, and 90.29%, respectively. Except for pelvic, the tolerance limits for the brain, head and neck, and abdomen were close to the universal tolerance limit of TG-218 (95%), and the action limits for all sites were higher than the universal action limit of TG-218 (90%). The out-of-control VMAT QAs were detected by the individual control chart, including one case of head and neck, two of the abdomen and two of the pelvic site. Four of them were affected by the setup error, and one was affected by the calibration of ArcCHECK. The results show that the SPC methodology can effectively monitor the IMRT/VMAT QA processes. Setting treatment site-specific tolerance limits is helpful to investigate the cause of out-of-control VMAT QA.
Calibration
;
Humans
;
Quality Assurance, Health Care
;
Radiotherapy Dosage
;
Radiotherapy Planning, Computer-Assisted
;
Radiotherapy, Intensity-Modulated
5.Association between Types of Usual Source of Care and User Perception of Overall Health Care Service Quality in Korea
Korean Journal of Family Medicine 2019;40(3):143-150
BACKGROUND: Patients' perceptions of care tend to correlate with the quality of care provided. Different health care systems and service environments may show different associations between types of usual source of care (USC) and overall service quality assessment. We attempted to analyze this association as a benefit of having a USC. METHODS: This study used the 2012 Korea Health Panel data version 1.1 as representative national household survey data. The total number of subjects aged 18 years or more was 12,708. The number of subjects in the final analysis was 10,665. Multiple logistic regression analysis was used to assess the association between types of USC and overall health care service quality. The main outcome variable was users' ratings of the quality of health care service. RESULTS: People having a usual doctor (n=1,796) were more likely to positively assess the quality of health care they received than those not having a USC (n=7,920; odds ratio [OR], 1.39; 95% confidence interval [CI], 1.20–1.60) or with those having only a place as a USC without a usual doctor (n=949; OR, 1.29; 95% CI, 1.05–1.58) after adjustment for demographic characteristics and health-related variables. CONCLUSION: People having a usual doctor rated overall health care service quality as high, which might be due to benefits of primary care attributes related to usual doctors. Further studies are needed to elucidate the causal relationship. This finding implies that health policies encouraging people to have a usual doctor are needed in Korea.
Delivery of Health Care
;
Family Characteristics
;
Health Policy
;
Korea
;
Logistic Models
;
Odds Ratio
;
Primary Health Care
;
Quality Assurance, Health Care
;
Quality of Health Care
;
Surveys and Questionnaires
6.Appraisal of the Quality and Contents of Clinical Practice Guidelines for Hypertension Management in Chinese Medicine: A Systematic Review.
Ya YUWEN ; Xue-Jie HAN ; Wei-Liang WENG ; Xue-Yao ZHAO ; Yu-Qi LIU ; Wei-Qiang LI ; Da-Sheng LIU ; Yan-Ping WANG ; Ai-Ping LU
Chinese journal of integrative medicine 2018;24(7):545-550
OBJECTIVETo evaluate the quality and consistency of recommendations in the clinical practice guidelines (CPGs) for hypertension in Chinese medicine (CM).
METHODSCM CPGs were identified from 5 electronic databases and hand searches through related handbooks published from January 1990 to December 2013. Three reviewers independently appraised the CPGs based on the Appraisal of Guidelines for Research and Evaluation (AGREE II) instrument, and compared the CPGs' recommendations on CM syndrome pattern classification and treatment.
RESULTSFive CM CPGs for hypertension were included. The quality score of the evidence-based (EB) guideline was higher than those of the consensus-based with no explicit consideration of evidence-based (CB-EB) and the consensus-based (CB) guidelines. Three out of five patterns in the CPGs were recommended by the EB guideline. Tianma Gouteng Formula () in the EB guideline was recommended mostly for hypertension patients with pattern of ascendant hyperactivity of Gan (Liver)-yang and pattern of yin deficiency with yang hyperactivity in the CPGs. Acupuncture and massage were recommended for Grade I and Grade II hypertension with severe symptoms weakening the quality of life in the EB guideline. For Grade I and Grade II hypertension, CM could be used alone, while for Grade III hypertension, they should be used in combination with Western medicines.
CONCLUSIONThe quality of EB guideline was higher than those of CB and CB-EB CPGs in CM for hypertension and CM should be prescribed alone or combined with Western medicines based on the grade of hypertension.
Humans ; Hypertension ; therapy ; Medicine, Chinese Traditional ; methods ; standards ; Practice Guidelines as Topic ; standards ; Quality Assurance, Health Care ; Quality of Health Care ; standards ; Quality of Life
7.Indicators and Qualitative Assessment of Lung Cancer Management by Health Insurance Review and Assessment Service (HIRA) of Korea in 2015
Chang Dong YEO ; Myoung Kyu LEE ; Seung Hyeun LEE ; Eun Young KIM ; Ik Jae LEE ; Heae Surng PARK ; Yoon Soo CHANG
Tuberculosis and Respiratory Diseases 2018;81(1):19-28
Cancer is the leading cause of death in the Republic of Korea and cancer death accounts for 27.8% of the total deaths, which is not only a social issue but also a concern for the public. Among the cancer death rates, lung cancer mortality account for 34 deaths per 100,000 populations, making it the number one cancer death rate. In a preliminary report on cancer death in 2012, the lung cancer mortality ratio showed the regional variation indicating that there were differences in the qualitative level and the structure among the medical care benefit agency and in the assessment of the treatment process. Therefore, the Health Insurance Review and Assessment Service (HIRA) had begun evaluation of the assessment of lung cancer treatment since 2014 to improve the quality of lung cancer care through evaluation and feeds back the results of lung cancer care process. In this report, authors described the current Indicators for the lung cancer adequacy assessment proposed by HIRA and results of the evaluation reported in 2017.
Cause of Death
;
Evaluation Studies as Topic
;
Insurance, Health
;
Korea
;
Lung Neoplasms
;
Lung
;
Mortality
;
Quality Assurance, Health Care
;
Republic of Korea
8.Survey and Solutions for the Current Status of Quality Control in Small Hospital Laboratories.
Jae Han KIM ; Eun Jin CHOI ; Gyuhyeon HWANG ; Jae Ho LEE ; Mi Soon HAN
Journal of Laboratory Medicine and Quality Assurance 2018;40(2):101-108
BACKGROUND: To prevent medically significant errors, hospital laboratories must perform thorough statistical quality control (QC) procedures. We surveyed the QC status of small laboratories and created new statistical QC software that they can easily use for improving QC. METHODS: A questionnaire on the status of external and internal QC was created and sent to clinics and hospitals with small-scale laboratories. We then created QC software that can be downloaded and installed for free. RESULTS: External quality assessments were performed in 32% of the clinics (22 of 66) and 52% of the hospitals (12 of 23). Seventy-three percent of all institutions (66 of 90) carried out an internal quality assessment based on their own guidelines, mostly using commercialized QC materials. However, only 52% of clinics and 23% of hospitals used their own acceptable range instead of the manufacturer's expected range. In addition, the proportion of manual QC management reached 52% in clinics and 82% in hospitals. The QC software we designed covers all the basic functions of statistical QC and aims to improve the quality of laboratories. CONCLUSIONS: We obtained basic data on the current status of external and internal QC in small-scale laboratories using this survey. Furthermore, we suggested that new QC software may actually help to improve QC of small laboratories.
Laboratories, Hospital*
;
Quality Assurance, Health Care
;
Quality Control*
9.Two Small Intravenous Catheters for High-Rate Contrast Medium Injection for Computed Tomography in Patients Lacking Superficial Veins to Accommodate a Large Catheter.
Bum Gu SON ; Min Jung KIM ; Myeung Hwa PARK ; Kyoungsook KIM ; Jiyu KIM ; Se Young KIM ; Kyung Jin LEE ; Sang Hyun CHOI ; Ah Young KIM ; Seong Ho PARK
Korean Journal of Radiology 2018;19(3):489-497
OBJECTIVE: To prospectively investigate the feasibility of using 2 small intravenous catheters for high-rate computed tomography (CT) contrast injection in patients lacking superficial veins capable of accommodating ≤ 20-gauge catheters. MATERIALS AND METHODS: Sixty-eight consecutive eligible adults referred for dynamic liver CT were enrolled; 58 had previously undergone liver CT, including 8 that experienced extravasation. Two 22- or 24-gauge catheters were placed in all patients after 2–5 venipunctures, and 2 mL/kg of contrast agent (370 mg I/mL) was split-administered through both catheters to achieve total flow rate of 4 mL/s. Patients' experience and examination success rate, defined as uneventful scans completed at 4 mL/s or at < 4 mL/s achieving standard image quality in all phases, were analyzed. Quantitative hepatic signal-to-noise and hepatic vascular contrast-to-noise ratios (CNRs) were compared with 30 control examinations scanned at 4 mL/s using an 18-gauge catheter. RESULTS: One case each of extravasation and severe injection pain caused the examination to be aborted. Success rate was 88.2% (60/68; 54 patients scanned at 4 mL/s, 6 at 3.5–3.9 mL/s). Fifty-five of 58 patients (94.8%) that had past CT regarded the venipuncture as more tolerable than (n = 36) or similar to (n = 19) past experiences; 45 of 58 patients (77.6%) found contrast injection less painful than (n = 35) or similar to (n = 10) past experiences. When compared with control examinations, signal-to-noise ratio was similar in all phases (p ≥ 0.502), but the hepatic arterial CNR in arterial phase was slightly inferior (p ≤ 0.047). CONCLUSION: Using 2 small intravenous catheters can effectively achieve high-rate CT contrast injection in patients lacking adequate superficial veins.
Adult
;
Catheters*
;
Contrast Media
;
Humans
;
Liver
;
Multidetector Computed Tomography
;
Patient Satisfaction
;
Phlebotomy
;
Prospective Studies
;
Quality Assurance, Health Care
;
Signal-To-Noise Ratio
;
Veins*
10.Centralized Lung Nodule Management at A Veterans Hospital Using A Multidisciplinary Lung Nodule Evaluation Team (LNET).
William R WRIGHTSON ; Umar GAUHAR ; Fred HENDLER ; Teresa JOINER ; Jennifer PENDLETON
Chinese Journal of Lung Cancer 2018;21(11):828-832
BACKGROUND:
Lung nodules are frequently identified on imaging studies and can represent early lung cancers. We instituted the Lung Nodule Evaluation Team (LNET) to optimize management of these nodules by a lung specialist physician. All lung nodules identified by a radiologist prompted a direct consultation to this service. We report our initial experience with this process.
METHODS:
This is a retrospective review of patients with lung nodules at a single institution from 2008 to 2015. Since October 2014, lung nodules >3 mm identified on computed tomography (CT) scanning of the chest generate an automatic consult to LNET from the radiology service. Demographic, nodule and follow up data was entered into a surveillance database and summarized.
RESULTS:
There were 1,873 patients identified in the database. Of these, 900 patients were undergoing active surveillance. Consults increased from 5.5 to 93 per month after the start of the new consult program. Lung nodules were identified on 64% of chest CT scans. Prior to the direct radiology consult the average size of a nodule was 1.7 cm and 0.7 cm after. The overall time from initial nodule imaging to initiating a management plan by a thoracic specialist physician was 3.7 days.
CONCLUSIONS
Assessment of lung nodules by a specialist physician is important to ensure appropriate long term management and optimize utilization of diagnostic interventions. A direct radiology consult to a specialized team of chest physicians decreased the time in initiating a management plan, identified smaller nodules and may lead to a more judicious use of health care resources in the management of lung nodules.
Hospitals, Veterans
;
Humans
;
Lung Neoplasms
;
diagnostic imaging
;
pathology
;
therapy
;
Quality Assurance, Health Care
;
Tomography, X-Ray Computed
;
Tumor Burden

Result Analysis