1.Correction to: Human cytomegalovirus DNA and immediate early protein 1/2 are highly associated with glioma and prognosis.
Le WEN ; Fei ZHAO ; Yong QIU ; Shuang CHENG ; Jin-Yan SUN ; Wei FANG ; Simon RAYNER ; Michael A MCVOY ; Xing-Jun JIANG ; Qiyi TANG ; Fang-Cheng LI ; Fei HU ; Min-Hua LUO
Protein & Cell 2021;12(4):313-313
		                        		
		                        		
		                        		
		                        	
2.Human cytomegalovirus DNA and immediate early protein 1/2 are highly associated with glioma and prognosis.
Le WEN ; Fei ZHAO ; Yong QIU ; Shuang CHENG ; Jin-Yan SUN ; Wei FANG ; Simon RAYNER ; Michael A MCVOY ; Xing-Jun JIANG ; Qiyi TANG ; Fang-Cheng LI ; Fei HU ; Min-Hua LUO
Protein & Cell 2020;11(7):525-533
		                        		
		                        		
		                        		
		                        	
3.Inflammation activated bone marrow mesenchymal stem cell conditioned medium repairs radiation-induced acute injury to intestinal epithelial stem cells
Faxin MA ; Weihong SHA ; Qiyi WANG ; Jinliang LI ; Quan LU ; Yujun LUO
Chinese Journal of Tissue Engineering Research 2019;23(12):1324-1329
		                        		
		                        			
		                        			BACKGROUND: Our previous findings indicate that inflammation-activated bone marrow mesenchymal stem cell conditioned medium (MSC-CM) contribute to repairing the structure and function of the small intestine after radiation-induced acute intestinal injury. However, it is unclear whether the repair effect can be achieved by regulating small intestinal stem cells. OBJECTIVE: To investigate the effects of inflammation-activated bone marrow MSC-CM on the small intestinal epithelial stem cells after acute radiation-induced intestinal injury and to further discuss the repairing mechanism. METHODS: Bone marrow mesenchymal stem cells of Sprague-Dawley rats were separated, cultured and identified. Then, the bone marrow mesenchymal stem cells were co-cultured with normal or radiation-induced IEC-6 cell lines in the Transwell system for 24 hours. Inflammation-activated bone marrow mesenchymal stem cells were cultured alone for 48 hours. Non-activated MSC-CM (MSC-CMNOR) and MSC-CM under radiation-induced inflammatory condition (MSC-CMIR) were collected. Adult Sprague-Dawley rats (provided by the Experimental Center of Sun Yat-Sen University North Campus) were randomly divided into four groups with 20 rats in each group: control group, radiation group, radiation+MSC-CMNOR group and radiation+MSC-CMIR group. The rats in the latter three groups were exposed to one-off 14 Gy whole abdominal radiation to make a rat model of acute radiation-induced small intestinal injury. Three-day continuous administration beginning within 4 hours after successful modeling was given via the tail vein and intraperitoneal implantation of Alzet micro-osmotic pumps: EMEM-F12 (200 μL/d) for the radiation group, MSC-CMNOR for radiation+MSC-CMNOR group and MSC-CMIR for radiation+MSC-CMIR group. There was 2 mL of concentrated conditioned medium in the pump which was released at a constant rate of 10 μL/h into the abdominal cavity after implantation. Intestinal samples were collected at 1, 3, 5, 7 days after radiation for immunochemistry staining, western blot and qRT-PCR detection. RESULTS AND CONCLUSION: (1) On the 3rd day after radiation, Lgr5 positive cells, which were actively proliferating on the base of crypts, became significantly reduced compared with the normal control group, and there was nearly no existing Lgr5 positive cells. However, after infusion of MSC-CMIR, Lgr5 positive intestinal stem cells were significantly increased compared with the radiation group, while in the radiation+MSCNOR group, there was no significant increase in Lgr5 positive intestinal stem cells. (2) On the 3rd day after radiation injury, Bmi1 positive intestinal stem cells were almost invisible. After infusion of MSC-CMIR, Bmi1 positive intestinal stem cells increased significantly, and it was observed not only in the +4 cell position but also in the common position used to be Lgr5 stem cells, indicating that Bmi1 stem cells could differentiate into Lgr5 positive cells to act its repairing effect. (3) Western blot and qRT-PCR further confirmed that the radiation+MSC-CMIR group was significantly higher on the Lgr5 expression level than the radiation group and the radiation+MSC-CMNOR group, and it returned to the normal level on the 7th day after the continuous high expression level. The repair effect of radiation+MSC-CMNOR group was weaker, and only on the 7th day, the expression level of Lgr5 was statistically different from the radiation group. To conclude, inflammation-activated bone marrow MSC-CM exert a protective effect on the small intestinal epithelial stem cells after acute radiation-induced intestinal injury
		                        		
		                        		
		                        		
		                        	
4.Neutralization of anti-venom IgY against main activities of Deinagkistrodon acutus venom
Jinhua LIU ; Heng LI ; Qiyi HE ; Yingfeng ZHANG ; Diancheng CHEN ; Cong LUO ; Xiaodong YU
Chinese Pharmacological Bulletin 2017;33(1):58-62
		                        		
		                        			
		                        			Aim To evaluate the potency of anti-D. acutus venom IgY neutralizing the main activities of D. acutus venom.Methods After mixing the different a-mounts of IgY with snake venom and incubating togeth-er,the main activities of snake venom were assayed by biochemical methods.Results The in vitro assays in-dicated that anti-D.acutus venom IgY obviously neu-tralized the activities of PLA2 ,5′-nucleotidase,hyalu-ronidase,metalloprotease and serine proteinase (fi-brinogenase)in D.acutus venom.Mouse experiments showed that the ED50 value of IgY for mouse was 1 131.09 μg.Conclusion Anti-D.acutus venom IgY antibodies have good effects in neutralizing D.acutus venom without the toxicities themselves.
		                        		
		                        		
		                        		
		                        	
5.Related research on mechanical property of valve membrane in transcatheter bioprosthesis valve based on the chemical modification and cutting technology.
Dakai CHEN ; Yu LI ; Qiyi LUO ; Baolin LIU ; Kangmin CHEN
Journal of Biomedical Engineering 2014;31(4):801-805
		                        		
		                        			
		                        			The aim of this research is to investigate the preparation method of valve membrane in transcatheter bio- prosthetic valve, and to study the effect of chemical modification and cutting technology to tensile property and suture force property of valve membrane. We carried out a series of processes to perform the tests, such as firstly to test the crosslinking degree of valve membrane using ninhydrin method, then to test the tensile property and suture force property by using Instron's biomechanicAl testing equipment, and then to observe the collagen fiber orientation in valve membrane using Instron's biomechanical testing equipment and using field emission scanning electron microscopy. The study indicated that after the chemical modification, the crosslinking degree, tensile strength and suture force strength increasing rate of valve membrane were 93.78% ± 3. 2%, (8.24 ± 0.79) MPa, 102%, respectively. The valve membrane had a better biomechanical property and would be expected to become valve membrane in transcatheter bioprosthesis valve.
		                        		
		                        		
		                        		
		                        			Bioprosthesis
		                        			;
		                        		
		                        			Collagen
		                        			;
		                        		
		                        			chemistry
		                        			;
		                        		
		                        			Heart Valve Prosthesis
		                        			;
		                        		
		                        			Microscopy, Electron, Scanning
		                        			;
		                        		
		                        			Tensile Strength
		                        			
		                        		
		                        	
6.Finite element analysis for compression and expansion behavior of magnesium stent.
Hongliang CHEN ; Xiangkun LIU ; Guangyin YUAN ; Linlin ZHANG ; Zhonghua LI ; Qiyi LUO ; Feng LIN
Chinese Journal of Medical Instrumentation 2014;38(3):161-176
		                        		
		                        			
		                        			Magnesium stents have gained increasing interest as an ideal stent of future intervention. In order to study the deformation behavior of magnesium alloy stents in the interventional treatment, the finite element method was used to analysis the effects of different crimp and expansion dimensions on the mechanical properties (maximum stress, radial recoil rate, longitudinal shortening rate and radial strength). The results showed that crimping and expanding have a minimal influence on the stent radial strength. When the expansion size is same, the maximum equivalent stress and recoil rate decrease with the crimp size. When the crimp size is same, in contrast with the radial recoil rate, the maximum equivalent stress and longitudinal shortening rate increase with the expansion size. In addition the paper verified the radial strength-radial displacement curve obtained by FEM. Results are basically consistent, indicating the finite element method can efficiently provide researchers with reliable, high-quality design.
		                        		
		                        		
		                        		
		                        			Alloys
		                        			;
		                        		
		                        			Finite Element Analysis
		                        			;
		                        		
		                        			Magnesium
		                        			;
		                        		
		                        			Stents
		                        			
		                        		
		                        	
7.Optimization based on finite element technique of nitinol stent.
Feng LIN ; Xiangkun LIU ; Nannan HUANG ; Quanchao GAO ; Zhonghua LI ; Tianping YAO ; Qiyi LUO ; Jiahua HUANG
Chinese Journal of Medical Instrumentation 2014;38(2):98-101
		                        		
		                        			
		                        			The finite element method was used for simulating the mechanical performance and fatigue safety of three different structures of Nitinol stent. According to the actual situation, after proposing reasonable assumptions and simplification, the geometry model and finite element model establishment, material mode selection and boundary condition setting are completed. The strain and fatigue life of different stent edges wide (omega) or strut angle (theta) are computed. The result can provide a valuable reference for the optimal design of stent.
		                        		
		                        		
		                        		
		                        			Alloys
		                        			;
		                        		
		                        			Finite Element Analysis
		                        			;
		                        		
		                        			Prosthesis Design
		                        			;
		                        		
		                        			Stents
		                        			
		                        		
		                        	
8.Optimization Based on Finite Element Technique of Nitinol Stent
Feng LIN ; Xiangkun LIU ; Nannan HUANG ; Quanchao GAO ; Zhonghua LI ; Tianping YAO ; Qiyi LUO ; Jiahua HUANG
Chinese Journal of Medical Instrumentation 2014;(2):98-101
		                        		
		                        			
		                        			The finite element method was used for simulating the mechanical performance and fatigue safety of three different structures of Nitinol stent. According to the actual situation, after proposing reasonable assumptions and simplification, the geometry model and finite element model establishment, material mode selection and boundary condition setting are completed. The strain and fatigue life of different stent edges wide (ω) or strut angle (q) are computed. The result can provide a valuable reference for the optimal design of stent.
		                        		
		                        		
		                        		
		                        	
9.Finite Element Analysis for Compression and Expansion Behavior of Magnesium Stent
Hongliang CHEN ; Xiangkun LIU ; Guangyin YUAN ; Linlin ZHANG ; Zhonghua LI ; Qiyi LUO ; Feng LIN
Chinese Journal of Medical Instrumentation 2014;(3):161-164,176
		                        		
		                        			
		                        			Magnesium stents have gained increasing interest as an ideal stent of future intervention. In order to study the deformation behavior of magnesium al oy stents in the interventional treatment, the finite element method was used to analysis the effects of different crimp and expansion dimensions on the mechanical properties (maximum stress, radial recoil rate, longitudinal shortening rate and radial strength). The results showed that crimping and expanding have a minimal influence on the stent radial strength. When the expansion size is same, the maximum equivalent stress and recoil rate decrease with the crimp size. When the crimp size is same, in contrast with the radial recoil rate, the maximum equivalent stress and longitudinal shortening rate increase with the expansion size. In addition the paper verified the radial strength-radial displacement curve obtained by FEM. Results are basical y consistent, indicating the finite element method can efficiently provide researchers with reliable, high-quality design.
		                        		
		                        		
		                        		
		                        	
10.Application status and prospects of thrombectomy devices for acute ischemic stroke.
Qingshun XU ; Qiaorong JIN ; Zunzhang NI ; Zhiyong XIE ; Qiyi LUO
Chinese Journal of Medical Instrumentation 2013;37(4):274-290
		                        		
		                        			
		                        			The character and application status of interventional thrombectomy devices for acute ischemic stroke (AIS) are briefly introduced and the development trend is also analyzed.
		                        		
		                        		
		                        		
		                        			Brain Ischemia
		                        			;
		                        		
		                        			drug therapy
		                        			;
		                        		
		                        			surgery
		                        			;
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Stroke
		                        			;
		                        		
		                        			drug therapy
		                        			;
		                        		
		                        			surgery
		                        			;
		                        		
		                        			Thrombectomy
		                        			;
		                        		
		                        			instrumentation
		                        			;
		                        		
		                        			Thrombolytic Therapy
		                        			;
		                        		
		                        			instrumentation
		                        			
		                        		
		                        	
            
Result Analysis
Print
Save
E-mail