1.Wdr63 Deletion Aggravates Ulcerative Colitis Likely by Affecting Th17/Treg Balance and Gut Microbiota
Hao ZHU ; Meng-Yuan ZHU ; Yang-Yang CAO ; Qiu-Bo YANG ; Zhi-Peng FAN
Progress in Biochemistry and Biophysics 2025;52(1):209-222
ObjectiveUlcerative colitis is a prevalent immunoinflammatory disease. Th17/Treg cell imbalance and gut microbiota dysregulation are key factors in ulcerative colitis pathogenesis. The actin cytoskeleton contributes to regulating the proliferation, differentiation, and migration of Th17 and Treg cells. Wdr63, a gene containing the WD repeat domain, participates in the structure and functional modulation of actin cytoskeleton. Recent research indicates that WDR63 may serve as a regulator of cell migration and metastasis via actin polymerization inhibition. This article aims to explore the effect of Wdr63 deletion on Th17/Treg cells and ulcerative colitis. MethodsWe constructed Wdr63-/- mice, induced colitis in mice using dextran sulfate sodium salt, collected colon tissue for histopathological staining, collected mesenteric lymph nodes for flow cytometry analysis, and collected healthy mouse feces for microbial diversity detection. ResultsCompared with wild-type colitis mice, Wdr63-/- colitis mice had a more pronounced shortening of colonic tissue, higher scores on disease activity index and histological damage index, Treg cells decreased and Th17 cells increased in colonic tissue and mesenteric lymph nodes, a lower level of anti-inflammatory cytokine IL-10, and a higher level of pro-inflammatory cytokine IL-17A. In addition, WDR63 has shown positive effects on maintaining intestinal microbiota homeostasis. It maintains the balance of Bacteroidota and Firmicutes, promoting the formation of beneficial intestinal bacteria linked to immune inflammation. ConclusionWdr63 deletion aggravates ulcerative colitis in mice, WDR63 inhibits colonic inflammation likely by regulating Th17/Treg balance and maintains intestinal microbiota homeostasis.
2.GBA1 Thr408Met mutation in a patient with Parkinson’s disease
Yi ZHAO ; Junwen LI ; Chunlian JU ; Weibin QIU ; Bo ZUO ; Zhigang YANG ; Yansheng LI
Chinese Journal of Clinical Medicine 2025;32(3):524-528
GBA1 gene mutation is an important genetic risk factor for Parkinson’s disease (PD). This paper reports a case of a 43-year-old male PD patient carrying a rare heterozygous Thr408Met mutation in the GBA1 gene identified through whole-exome sequencing, leading to a diagnosis of GBA1-associated PD. The patient’s motor symptoms were primarily characterized by bradykinesia and rigidity, without significant cognitive decline. Treatment with low-dose levodopa combined with a dopamine agonist resulted in significant symptomatic improvement.
3.Relationship Among Fungal Diversity at Different Levels of Root System of Stellaria dichotoma var. lanceolata, Soil Properties, and Main Components of Medicinal Materials in Lithosol Habitats
Wangsuo LIU ; Kaiyang QIU ; Darifu BA ; Xuehua GAO ; Zhiming YANG ; Min GAO ; Fang ZHANG ; Bo ZHANG
Chinese Journal of Experimental Traditional Medical Formulae 2024;30(6):160-168
ObjectiveTo explore the interaction among root fungi of Stellaria dichotoma var. lanceolata, soil factors, and main components of medicinal materials in lithosol habitats. MethodHigh-throughput sequencing technology was employed to determine the fungal community of the root system of S. dichotoma var. lanceolata at different levels (bulk soil, rhizosphere soil, rhizoplane soil, and root interior) and the soil properties of the root system (bulk and rhizosphere), and the relationship among the fungal community, soil properties, and the main components of medicinal materials was analyzed. ResultThe total phosphorus, available phosphorus, alkaline nitrogen, dissolved organic carbon, and soil water content in the rhizosphere soil of S. dichotoma var. lanceolata were slightly higher than those in the rhizosphere, but the difference was not significant. Ascomycota is the dominant phylum of root fungi in S. dichotoma var. lanceolata. In the progressive level of bulk-rhizosphere-rhizoplane-root interior system, although the fungal diversity gradually decreased, the abundance of Hypocreales, a new phylum (unclassified_ k_ Fungi), Helotiales, and Natipusilales gradually increased, among which Hypocreales is the most important fungal group in the root system of S. dichotoma var. lanceolata. The structural equation model (SEM) shows that the physicochemical factors of the root-soil play an important regulatory role in the fungal community and the main components of medicinal herbs, with soil total nitrogen, alkaline nitrogen, soil water content, and pH being the main regulatory factors. Soil nitrogen content is the key to promoting the main components of the medicinal herbs, and Penicillium fungi are the key fungal group to regulate the main components of the medicinal herbs. ConclusionIt highlights that the physicochemical properties of the soil of S. dichotoma var. lanceolata play a crucial role in the fungal community and the components of medicinal materials. Hypocreales fungi in the root of S. dichotoma var. lanceolata were an important group, and Penicillium fungi had a certain role in mediating the components of medicinal materials.
4. Research progress in the treatment of early Alzheimer's disease with lecanemab
Panpan JIN ; Yang LIU ; Huizhen WU ; Panpan JIN ; Yang LIU ; Bo QIU ; Huizhen WU
Chinese Journal of Clinical Pharmacology and Therapeutics 2024;29(2):207-214
Lecanemab is a new drug used to treat early Alzheimer's disease (AD) with mild cognitive impairment or mild dementia. It is a human anti-Aβ fibril monoclonal IgG1 antibody, which is injected intravenously into the patient, through the blood-brain barrier into the brain, clearing amyloid plaque, thereby slowing the rate of cognitive decline in patients and delaying disease progression. This article reviews the pharmacological studies, clinical studies, safety and limitations of lecanemab, in order to help clinical understand the current research status and existing achievements of this drug.
5.Development of the robotic digestive endoscope system and an experimental study on mechanistic model and living animals (with video)
Bingrong LIU ; Yili FU ; Kaipeng LIU ; Deliang LI ; Bo PAN ; Dan LIU ; Hao QIU ; Xiaocan JIA ; Jianping CHEN ; Jiyu ZHANG ; Mei WANG ; Fengdong LI ; Xiaopeng ZHANG ; Zongling KAN ; Jinghao LI ; Yuan GAO ; Min SU ; Quanqin XIE ; Jun YANG ; Yu LIU ; Lixia ZHAO
Chinese Journal of Digestive Endoscopy 2024;41(1):35-42
Objective:To develop a robotic digestive endoscope system (RDES) and to evaluate its feasibility, safety and control performance by experiments.Methods:The RDES was designed based on the master-slave control system, which consisted of 3 parts: the integrated endoscope, including a knob and button robotic control system integrated with a gastroscope; the robotic mechanical arm system, including the base and arm, as well as the endoscopic advance-retreat control device (force-feedback function was designed) and the endoscopic axial rotation control device; the control console, including a master manipulator and an image monitor. The operator sit far away from the endoscope and controlled the master manipulator to bend the end of the endoscope and to control advance, retract and rotation of the endoscope. The air supply, water supply, suction, figure fixing and motion scaling switching was realized by pressing buttons on the master manipulator. In the endoscopy experiments performed on live pigs, 5 physicians each were in the beginner and advanced groups. Each operator operated RDES and traditional endoscope (2 weeks interval) to perform porcine gastroscopy 6 times, comparing the examination time. In the experiment of endoscopic circle drawing on the inner wall of the simulated stomach model, each operator in the two groups operated RDES 1∶1 motion scaling, 5∶1 motion scaling and ordinary endoscope to complete endoscopic circle drawing 6 times, comparing the completion time, accuracy (i.e. trajectory deviation) and workload.Results:RDES was operated normally with good force feedback function. All porcine in vivo gastroscopies were successful, without mucosal injury, bleeding or perforation. In beginner and advanced groups, the examination time of both RDES and ordinary endoscopy tended to decrease as the number of operations increased, but the decrease in time was greater for operating RDES than for operating ordinary endoscope (beginner group P=0.033; advanced group P=0.023). In the beginner group, the operators operating RDES with 1∶1 motion scaling or 5∶1 motion scaling to complete endoscopic circle drawing had shorter completion time [1.68 (1.40, 2.17) min, 1.73 (1.47, 2.37) min VS 4.13 (2.27, 5.16) min, H=32.506, P<0.001], better trajectory deviation (0.50±0.11 mm, 0.46±0.11 mm VS 0.82±0.26 mm, F=38.999, P<0.001], and less workload [42.00 (30.00, 50.33) points, 43.33 (35.33, 54.00) points VS 52.67 (48.67, 63.33) points, H=20.056, P<0.001] than operating ordinary endoscope. In the advanced group, the operators operating RDES with 1∶1 or 5∶1 motion scaling to complete endoscopic circle drawing had longer completion time than operating ordinary endoscope [1.72 (1.37, 2.53) min, 1.57 (1.25, 2.58) min VS 1.15 (0.86, 1.58) min, H=13.233, P=0.001], but trajectory deviation [0.47 (0.13, 0.57) mm, 0.44 (0.39, 0.58) mm VS 0.52 (0.42, 0.59) mm, H=3.202, P=0.202] and workload (44.62±21.77 points, 41.24±12.57 points VS 44.71±17.92 points, F=0.369, P=0.693) were not different from those of the ordinary endoscope. Conclusion:The RDES enables remote control, greatly reducing the endoscopists' workload. Additionally, it gives full play to the cooperative motion function of the large and small endoscopic knobs, making the control more flexible. Finally, it increases motion scaling switching function to make the control of endoscope more flexible and more accurate. It is also easy for beginners to learn and master, and can shorten the training period. So it can provide the possibility of remote endoscopic control and fully automated robotic endoscope.
6.Prognosis and its influencing factors in patients with non-gastric gastrointestinal stromal tumors at low risk of recurrence: a retrospective multicenter study in China
Linxi YANG ; Weili YANG ; Xin WU ; Peng ZHANG ; Bo ZHANG ; Junjun MA ; Xinhua ZHANG ; Haoran QIAN ; Ye ZHOU ; Tao CHEN ; Hao XU ; Guoli GU ; Zhidong GAO ; Gang ZHAI ; Xiaofeng SUN ; Changqing JING ; Haibo QIU ; Xiaodong GAO ; Hui CAO ; Ming WANG
Chinese Journal of Gastrointestinal Surgery 2024;27(11):1123-1132
Objective:To investigate the prognosis and the factors that influence it in patients with non-gastric gastrointestinal stromal tumors (GISTs) who are at low risk of recurrence.Methods:This was a retrospective cohort study. Clinicopathologic and prognostic data from patients with non-gastric GISTs and at low risk of recurrence (i.e., very low-risk or low-risk according to the 2008 version of the Modified NIH Risk Classification), who attended 18 medical centers in China between January 2000 and June 2023, were collected. We excluded patients with a history of prior malignancy, concurrent primary malignancy, multiple GISTs, and those who had received preoperative imatinib. The study cohort comprised 1,571 patients with GISTs, 370 (23.6%) of whom were at very low-risk and 1,201 (76.4%) at low-risk of recurrence. The cohort included 799 (50.9%) men and 772 (49.1%) women of median age 57 (16–93) years. Patients were followed up to July 2024. The prognosis and its influencing factors were analyzed. Receiver operating characteristic curves for tumor diameter and Ki67 were established, and the sensitivity, specificity, area under the curve (AUC) and optimal cut-off value with 95% confidence intervals were calculated. Propensity score matching was implemented using the 1:1 nearest neighbor matching method with a matching tolerance of 0.02.Results:With a median follow-up of 63 (12–267) months, the 5- and 10-year overall survival (OS) rates of the 1,571 patients were 99.5% and 98.0%, respectively, and the 5- and 10-year disease-free survival (DFS) rates were 96.3% and 94.4%, respectively. During postoperative follow-up, 3.8% (60/1,571) patients had disease recurrence or metastasis, comprising 0.8% (3/370) in the very low-risk group and 4.7% (57/1,201) in the low-risk group. In the low-risk group, recurrence or metastasis occurred in 5.5% (25/457) of patients with duodenal GISTs, 3.9% (25/645) of those with small intestinal GISTs, 9.2% (6/65) of those with rectal GISTs, and 10.0% (1/10) of those with colonic GISTs. Among the 60 patients with metastases, 56.7% (34/60) of the metastases were located in the abdominal cavity, 53.3% (32/60) in the liver, and 3.3% (2/60) in bone. During the follow-up period, 13 patients (0.8%) died of disease. Receiver operating characteristic curves were plotted for tumor diameter and Ki67 and assessed using the Jordon index. This showed that the difference in DFS between the two groups was statistically significant when the cutoff value for tumor diameter was 3.5 cm (AUC 0.731, 95% CI: 0.670–0.793, sensitivity 77.7%, specificity 64.1%). Furthermore, the difference in DFS between the two groups was statistically significant when the cutoff value for Ki67 was 5% (AUC 0.693, 95% CI: 0.624–0.762, sensitivity 60.7%, specificity 65.3%). Multifactorial analysis revealed that tumor diameter ≥3.5 cm, Ki67 ≥5%, and R1 resection were independent risk factors for DFS in patients with non-gastric GISTs at low risk of recurrence (all P<0.05). Furthermore, age >57 years, Ki67 ≥5%, and R1 resection were also independent risk factors for OS in patients with non-gastric GISTs at low risk of recurrence (all P<0.05). We also grouped the patients according to whether they had received postoperative adjuvant treatment with imatinib for 1 or 3 years. This yielded 137 patients in the less than 1-year group, 139 in the 1-year plus group; and 44 in both the less than 3 years and 3-years plus group. After propensity score matching for age, tumor diameter, Ki67, and resection status, the differences in survival between the two groups were not statistically significant (all P>0.05). The 10-year DFS and OS were 87.5% and 95.5%, respectively, in the group treated with imatinib for less than 1 year and 88.5% and 97.8%, respectively, in the group treated for more than 1 year. The 10-year DFS and OS were 89.6% and 92.6%, respectively, in the group treated with imatinib for less than 3 years and 88.0% and 100.0%, respectively, in the group treated with imatinib for more than 3 years. Conclusion:The overall prognosis of primary, non-gastric, low recurrence risk GISTs is relatively favorable; however, recurrences and metastases do occur. Age, tumor diameter, Ki67, and R1 resection may affect the prognosis. For some patients with low risk GISTs, administration of adjuvant therapy with imatinib for an appropriate duration may help prevent recurrence and improve survival.
7.Results of Lung Cancer Screening with Low-dose Computed Tomography and Exploration of Risk Factors in Guangzhou
LU XUANZHUANG ; QIU QIUXIA ; YANG CHUNYU ; LI CAICHEN ; LI JIANFU ; XIONG SHAN ; CHENG BO ; ZHOU CHUJING ; DU XIAOQIN ; ZHANG YI ; HE JIANXING ; LIANG WENHUA ; ZHONG NANSHAN
Chinese Journal of Lung Cancer 2024;27(5):345-358
Background and objective Both of lung cancer incidence and mortality rank first among all cancers in China.Previous lung cancer screening trials were mostly selective screening for high-risk groups such as smokers.Non-smoking women accounted for a considerable proportion of lung cancer cases in Asia.This study aimed to evaluate the outcome of community-based mass screening in Guangzhou and identify the high-risk factors for lung cancer.Methods Residents aged 40-74 years in Guangzhou were screened with low-dose computed tomography(LDCT)for lung cancer and the pulmonary nodules were classified and managed according to China National Lung Cancer Screening Guideline with Low-dose Computed Tomography(2018 version).The detection rate of positive nodules was calculated.Before the LDCT examination,residents were required to complete a"lung cancer risk factors questionnaire".The risk factors of the questionnaire were analyzed by least absolute shrinkage and selection operator(LASSO)penalized Logistic regression analysis.Results A total of 6256 residents were included in this study.1228 positive nodules(19.63%)and 117 lung cancers were confirmed,including 6 cases of Tis,103 cases of stage Ⅰ(accounting for 88.03%of lung cancer).The results of LASSO penalized Logistic regression analysis indicated that age ≥50 yr(OR=1.07,95%CI:1.06-1.07),history of cancer(OR=3.29,95%CI:3.22-3.37),textile industry(OR=1.10,95%CI:1.08-1.13),use coal for cooking in childhood(OR=1.14,95%CI:1.13-1.16)and food al-lergy(OR=1.10,95%CI:1.07-1.13)were risk factors of lung cancer for female in this district.Conclusion This study highlighted that numerous early stages of lung cancer cases were detected by LDCT,which could be applied to screen-ing of lung cancer in women.Besides,age ≥50 yr,personal history of cancer,textile industry and use coal for cooking in childhood are risk factors for women in this district,which suggested that it's high time to raise the awareness of early lung cancer screening in this group.
8.Study on the dosimetry effect of rotational errors of a multi-channel cylinder applicator of vagina
Wenjun ZHANG ; Lang YU ; Bo YANG ; Jie ZHANG ; Chunli LUO ; Qizhen ZHU ; Jingru YANG ; Jie QIU
China Medical Equipment 2024;21(1):34-39,45
Objective:To investigate the dosimetry effect of rotational errors of multi-channel cylinder vaginal applicator of intravaginal irradiation after surgery of endometrial cancer.Methods:A total of 18 patients who underwent surgery of endometrial cancer at Peking Union Medical College Hospital from June to December 2022 were selected.The plans of patients who adopted the treatment of multi-channel cylinder applicator of vagina were retrospectively analyzed,which maintained the same retained mode with clinical plan.The applicator was rotated clockwise by 22.5? and 45.0?,respectively,simulating the rotational errors that occurred in placing the applicator among clinical inter-fractions.And then,the changes of dosimetry of target area and organs at risk(OAR)under two kinds of rotation amplitudes were further analyzed.Results:When the applicator was rotated as 22.5?,the minimum doses to 90%volumes of CTV by 2.03%than that of clinical plan,which was significantly different(t=5.86,P<0.05),and the maximal doses to 2cc of OARs of bladder and rectum respectively increased 2.35%and 2.71%,and the differences of them were statistically significant(t=-3.49,-2.40,P<0.05),respectively.When the applicator was rotated as 45?,the D90 of the target area decreased by 5.75%than that of clinical plan,which was statistically significant(t=14.07,P<0.05).The D2cc values of the bladder and rectum increased respectively by 6.50%and 9.49%than that of clinical plan,which were statistically significant(t=-7.72,-6.9,P<0.05).The differences of the exposed doses of sigmoid colon and small intestine after the applicator was rotated by 22.5? and 45.0? between the plan and original plan were respectively less,which were not statistical significance.Conclusion:The multi-channel cylinder applicator can provide individualized dose distribution in intravaginal irradiation.However,attention should be paid to the placement of the applicator when patients undergo inter-fractional treatment,in order to avoid deviations in the angular alignment from the original plan.This can impact the dosages of the target area and OARs.
9.Research on the robustness of Ethos cervical cancer online fully automatic generation of adaptive plans
Bo YANG ; Zhiqun WANG ; Xiangyin MENG ; Yongguang LIANG ; Tingtian PANG ; Xingliu WANG ; Xiaoshen WANG ; Hongying LUO ; Jiawei CHEN ; Fuqiang CHEN ; Zongkai ZHOU ; Zhen ZHANG ; Jie QIU
Chinese Journal of Radiation Oncology 2024;33(2):145-151
Objective:To evaluate the robustness of fully automated adaptive planning for Ethos online adaptive radiotherapy (ART) based on the intelligent optimization engine (IOE).Methods:Clinical data of 11 stage ⅠB cervical cancer patients admitted to Peking Union Medical College Hospital between June 2021 and June 2022 were retrospectively analyzed. Original planning images and iterative cone-beam computed tomography (iCBCT) images of each radiotherapy treatment were acquired, and all patient data were imported into the Ethos simulator. IOE-based 9-field automatic plan generation was performed for 11 patients using Ethos, and the generated plans were sent to online adaptive radiotherapy simulation to obtain each online adaptive radiotherapy plan (273 fractions in total) and complete the simulated treatment. For comparison, manual plan design was performed based on the images and contoured structures used for online adaptive radiotherapy planning, and the manually plans created with evenly divided 9 fields. Dosimetric parameters, plan complexity parameters, and Mobius quality assurance (QA) pass rates were collected to compare and evaluate the robustness of the online adaptive radiotherapy plan in terms of organs at risk (OAR), target volume dosimetric parameters, and plan complexity by using paired t-test or rank sum test. Results:The online adaptive plan of cervical cancer had comparable planning target volume (PTV) coverage compared to the manual plan. For the clinical target volume (CTV) D 99%, online adaptive plan was significantly higher than the manual plan [(45.93±0.36) vs. (45.32±0.31) Gy, P<0.001]. For hot dose area, the maximum point dose (PTV D max) of adaptive plan was significantly higher than the manual plan [(49.89±1.25) vs. (48.48±0.77) Gy, P<0.001], but the PTV D 1% of adaptive plan was significantly lower than the manual plan [(47.22±0.29) vs. (47.59±0.48) Gy, P<0.001]. There was no statistical difference in the conformal index ( P=0.967). And there was significant difference in the homogeneity index, with same medians and less dispersion in adaptive plan ( P<0.001). For OAR dose, bladder D mean, rectal V 40 Gy, small intestine D mean of adaptive plan was slightly higher than that of the manual plan; the rectal D mean, small intestine D 2 cm3 of the adaptive plan was slightly lower than that of manual plan; dosimetric parameters of right and left femoral heads, spinal cord and bone marrow of the adaptive plan were better than those of manual plan. The adaptive plan had more monitor units (MU) than the manual plan, but the complexity of the adaptive plan was significantly lower than that of the manual plan (0.135±0.012 vs. 0.151±0.015, P<0.001). For Mobius γ pass rate (5%/3 mm), both adaptive and manual plans met clinical requirements. Conclusion:Ethos cervical cancer online adaptive plan, which is based on the IOE engine, demonstrates good robustness and ensures the quality of online adaptive plans generated for each treatment fraction.
10.Performance evaluation of Ethos intelligent optimization engine in automatic plan generation
Zhiqun WANG ; Bo YANG ; Xiangyin MENG ; Yongguang LIANG ; Tingtian PANG ; Xingliu WANG ; Xiaoshen WANG ; Hongying LUO ; Jiawei CHEN ; Fuqiang CHEN ; Zongkai ZHOU ; Zhen ZHANG ; Jie QIU
Chinese Journal of Radiation Oncology 2024;33(4):339-345
Objective:To evaluate the automatic optimization performance and clinical feasibility of the intelligent optimization engine (IOE) in the Ethos online adaptive radiotherapy platform.Methods:Clinical data of 11 patients with postoperative cervical cancer treated with Halcyon accelerator were retrospectively analyzed. Manual planning was performed for all patients using the 4 full arc volumetric modulated arc therapy (VMAT) (Manual-4Arc) in Eclipse, with a prescription dose of 45 Gy/25F. Patient images and structures were imported into the Ethos simulator, and appropriate clinical goals were added based on clinical requirements. The target coverage was normalized to 95%. Automatic plan generation was conducted using IOE, resulting in 7, 9, and 12 field intensity modulated radiotherapy (IMRT) plans (IMRT-7F、IMRT-9F、IMRT-12F), as well as 2 and 3 arc VMAT plans (VMAT-2Arc、VMAT-3Arc). Dosimetric index comparisons were made between the Manual-4Arc plans and the 5 groups of IOE-generated plans through one-way analysis of variance. Based on the analysis results, Turky post hoc multiple comparisons were performed to evaluate the automatic optimization performance of IOE.Results:In terms of the high dose area, the IMRT-12F plans showed the lowest D 1% for the planning target volume (PTV), and there were significant differences compared to the Manual-4Arc plans ( P=0.004). Regarding target coverage, all groups produced clinical target volume (CTV) plans that met the clinical requirements. Although the Ethos online adaptive plans were normalized during planning, the PTV coverage was slightly insufficient. For organs at risk (OAR) close to the target, such as the bladder, there were significant differences in V 30 Gy, V 40 Gy, and D mean among the 6 groups of plans. The dose ranking for the bladder was generally as follows: IMRT-12F

Result Analysis
Print
Save
E-mail