1.Risk factors of postoperative mortality of femoral neck fractures in elderly patients and construction of a nomogram predictive model
Zhipeng LI ; Dawei HUAN ; Zhaofeng YUAN ; Yue QIU ; Chao ZHANG ; Tianwei XIA ; Jirong SHEN
Chinese Journal of Tissue Engineering Research 2024;28(21):3361-3366
BACKGROUND:With a gradually aging population,improving the ability to screen for the risk of death after arthroplasty and implementing timely personalized intervention programs for the increasing number of elderly patients with femoral neck fractures is key to improving the postoperative status of patients and prolonging survival expectations. OBJECTIVE:To investigate the risk factors for postoperative mortality in elderly patients with femoral neck fractures and to construct a nomogram predictive model to predict their mortality risk. METHODS:The study was conducted on 155 elderly patients(≥65 years old)who underwent arthroplasty for femoral neck fracture from January 2016 to January 2021,and 147 patients who met the inclusion criteria were analyzed to collect clinical data that may affect the patients'postoperative mortality.Single-factor and multi-factor Cox regression analyses were successively used to screen independent risk factors associated with postoperative mortality.The column line graph model was constructed and validated using Rstudio software. RESULTS AND CONCLUSION:(1)Age,frailty(age-adjusted Charlson comorbidities score),preoperative activity status,osteoporosis,and postoperative serum albumin level were five independent risk factors for postoperative mortality in elderly patients with femoral neck fractures(P<0.05).(2)The nomogram predictive model was constructed based on the results of multifactorial analysis,with a consistency index of 0.819(95%CI:0.771-0.868).Receiver operating characteristic curve analysis showed that the area under curve for 1-year and 3-year survival prediction was 0.8543 and 0.7263,respectively,indicating that the nomogram predictive model has good discriminatory and predictive power;calibration curve and decision curve analysis also showed good model discriminative power and clinical utility value.(3)The constructed nomogram predictive model has good diagnostic efficacy and accuracy,and can effectively assess the risk of postoperative death of patients.
2.Comparison of Direct and Extraction Immunoassay Methods With Liquid Chromatography-Tandem Mass Spectrometry Measurement of Urinary Free Cortisol for the Diagnosis of Cushing’s Syndrome
Danni MU ; Jiadan FANG ; Songlin YU ; Yichen MA ; Jin CHENG ; Yingying HU ; Ailing SONG ; Fang ZHAO ; Qi ZHANG ; Zhihong QI ; Kui ZHANG ; Liangyu XIA ; Ling QIU ; Huijuan ZHU ; Xinqi CHENG
Annals of Laboratory Medicine 2024;44(1):29-37
Background:
Twenty-four-hour urinary free cortisol (UFC) measurement is the initial diagnostic test for Cushing’s syndrome (CS). We compared UFC determination by both direct and extraction immunoassays using Abbott Architect, Siemens Atellica Solution, and Beckman DxI800 with liquid chromatography-tandem mass spectrometry (LC-MS/MS). In addition, we evaluated the value of 24-hr UFC measured by six methods for diagnosing CS.
Methods:
Residual 24-hr urine samples of 94 CS and 246 non-CS patients were collected.A laboratory-developed LC-MS/MS method was used as reference. UFC was measured by direct assays (D) using Abbott, Siemens, and Beckman platforms and by extraction assays (E) using Siemens and Beckman platforms. Method was compared using Passing–Bablok regression and Bland–Altman plot analyses. Cut-off values for the six assays and corresponding sensitivities and specificities were calculated by ROC analysis.
Results:
Abbott-D, Beckman-E, Siemens-E, and Siemens-D showed strong correlations with LC-MS/MS (Spearman coefficient r = 0.965, 0.922, 0.922, and 0.897, respectively), while Beckman-D showed weaker correlation (r = 0.755). All immunoassays showed proportionally positive bias. The areas under the curve were 0.975 for Abbott-D, 0.972 for LCMS/MS, 0.966 for Siemens-E, 0.948 for Siemens-D, 0.955 for Beckman-E, and 0.877 for Beckman-D. The cut-off values varied significantly (154.8–1,321.5 nmol/24 hrs). Assay sensitivity and specificity ranged from 76.1% to 93.2% and from 93.0% to 97.1%, respectively.
Conclusions
Commercially available immunoassays for measuring UFC show different levels of analytical consistency compared to LC-MS/MS. Abbott-D, Siemens-E, and Beckman-E have high diagnostic accuracy for CS.
3.Correlation between Combined Urinary Metal Exposure and Grip Strength under Three Statistical Models: A Cross-sectional Study in Rural Guangxi
Jian Yu LIANG ; Hui Jia RONG ; Xiu Xue WANG ; Sheng Jian CAI ; Dong Li QIN ; Mei Qiu LIU ; Xu TANG ; Ting Xiao MO ; Fei Yan WEI ; Xia Yin LIN ; Xiang Shen HUANG ; Yu Ting LUO ; Yu Ruo GOU ; Jing Jie CAO ; Wu Chu HUANG ; Fu Yu LU ; Jian QIN ; Yong Zhi ZHANG
Biomedical and Environmental Sciences 2024;37(1):3-18
Objective This study aimed to investigate the potential relationship between urinary metals copper (Cu), arsenic (As), strontium (Sr), barium (Ba), iron (Fe), lead (Pb) and manganese (Mn) and grip strength. Methods We used linear regression models, quantile g-computation and Bayesian kernel machine regression (BKMR) to assess the relationship between metals and grip strength.Results In the multimetal linear regression, Cu (β=-2.119), As (β=-1.318), Sr (β=-2.480), Ba (β=0.781), Fe (β= 1.130) and Mn (β=-0.404) were significantly correlated with grip strength (P < 0.05). The results of the quantile g-computation showed that the risk of occurrence of grip strength reduction was -1.007 (95% confidence interval:-1.362, -0.652; P < 0.001) when each quartile of the mixture of the seven metals was increased. Bayesian kernel function regression model analysis showed that mixtures of the seven metals had a negative overall effect on grip strength, with Cu, As and Sr being negatively associated with grip strength levels. In the total population, potential interactions were observed between As and Mn and between Cu and Mn (Pinteractions of 0.003 and 0.018, respectively).Conclusion In summary, this study suggests that combined exposure to metal mixtures is negatively associated with grip strength. Cu, Sr and As were negatively correlated with grip strength levels, and there were potential interactions between As and Mn and between Cu and Mn.
4.Evaluation and application of automated quality control of automatic pipeline in clinical biochemical and immunological detection
Li′an HOU ; Xuesong SHANG ; Chaochao MA ; Liangyu XIA ; Li LIU ; Ying ZHANG ; Yujun SU ; Xin LIU ; Ling QIU
Chinese Journal of Laboratory Medicine 2024;47(1):86-93
Objective:To assess the applicability of fully automatic pipeline automated testing for internal quality control (automated quality control).Methods:Stability, assay efficiency and implementation costs of 18 biochemical tests, 5 immunoturbidimetric tests and 11 chemical illuminescent tests in the Department of Laboratory Medicine of Peking Union Hospital from January 2019 to July 2022 were evaluated using automated quality control implementation methods. The detailed method is as follows: quality control materials for biochemical, immunoturbidimetric and chemiluminescent tests were stored in the refrigerator in the pipeline which was controlled by the intermediate software, and were automatically retrieved and tested as pre-set followed by documenting and storing. The quality control setup for the biochemical tests included refreshing quality control materials daily and weekly,both of which were paralleled for 3 months. The on-line storage stability of quality control materials in the pipeline was evaluated by comparing the coefficients of variation ( CV) of the quality control results between the two patterns. Effect of automated quality control application was evaluated using 6 indicators, including the results′ variation of automatically performed and manually performed quality controls, the out-of-controlled rate, the consumption of quality control materials, the change of staff workload, the impact on the testing time of the first sample, and the failure rate of automated quality control. Results:(1) Storage stability of quality control materials in the pipeline: under the pattern of weekly refresh of the biochemical quality control materials, except for total carbon dioxide (TCO 2) (the CVs of low and high level quality control were respectively 20.24% and 21.82%) and sodium (the CV of low level quality control was 1.51%) that were greater than the allowable variation set by the laboratory, the CVs of the rest tests meet the lab requirements on the allowable variations. (2) The results′ variation of quality control in automatically performed and manually performed control patterns: in the patterns of daily refresh of biochemical quality control materials and weekly refresh of immunoturbidimetric and chemiluminescent quality control materials, the CVs of both low and high levels of quality control were lower in the automatically performed control pattern than that in manually performed pattern for 8 chemiluminescent items of dehydroepiandrosterone sulfate, estradiol, follicle stimulating hormone, luteinizing hormone, serum ferritin, serum folic acid, vitamin B12 and testosterone, 3 immunologic items of complement 3, C reactive protein and immunoglobulin G, and 10 biochemical items of alkaline phosphatase, glucose, calcium, chloride, potassium, lactate dehydrogenase, sodium, urea, low density lipoprotein cholesterol, and adenosine deaminase. The out-of-control rates of biochemistry, immunoturbidimetric and chemiluminescence tests in both quality control patterns conformed with the clinical routine work requirements. (3) Comparison of quality control materials′ consumption: compared with manually performed quality control, weekly consumption of automatically performed chemiluminescent quality control materials decreased 37.5% (from 8 ml to 5 ml); weekly consumption of automatically performed immunoturbidimetric quality control materials decreased 33.3% (from 3 ml to 2 ml). (4)Comparison of staff workload and first sample testing time: compared with manually performed quality control, automatical quality control reduced manual work by about 156 steps per week, and the daily initial testing time was earlier by 15 min on average. The failure rate was 54.5% (37/64) during the early-stage application of the automated quality control which dropped to 10.2% (13/128) in the late-stage. Conclusion:The results of automated quality control detected in the pipeline system meet the quality indicators′ requirements of the laboratory, and the application of automated quality control can improve the quality control, save costs, reduce workload, and improve work efficiency.
5.Clinical guidelines for the treatment of ankylosing spondylitis combined with lower cervical fracture in adults (version 2024)
Qingde WANG ; Yuan HE ; Bohua CHEN ; Tongwei CHU ; Jinpeng DU ; Jian DONG ; Haoyu FENG ; Shunwu FAN ; Shiqing FENG ; Yanzheng GAO ; Zhong GUAN ; Hua GUO ; Yong HAI ; Lijun HE ; Dianming JIANG ; Jianyuan JIANG ; Bin LIN ; Bin LIU ; Baoge LIU ; Chunde LI ; Fang LI ; Feng LI ; Guohua LYU ; Li LI ; Qi LIAO ; Weishi LI ; Xiaoguang LIU ; Hongjian LIU ; Yong LIU ; Zhongjun LIU ; Shibao LU ; Yong QIU ; Limin RONG ; Yong SHEN ; Huiyong SHEN ; Jun SHU ; Yueming SONG ; Tiansheng SUN ; Yan WANG ; Zhe WANG ; Zheng WANG ; Hong XIA ; Guoyong YIN ; Jinglong YAN ; Wen YUAN ; Zhaoming YE ; Jie ZHAO ; Jianguo ZHANG ; Yue ZHU ; Yingjie ZHOU ; Zhongmin ZHANG ; Wei MEI ; Dingjun HAO ; Baorong HE
Chinese Journal of Trauma 2024;40(2):97-106
Ankylosing spondylitis (AS) combined with lower cervical fracture is often categorized into unstable fracture, with a high incidence of neurological injury and a high rate of disability and morbidity. As factors such as shoulder occlusion may affect the accuracy of X-ray imaging diagnosis, it is often easily misdiagnosed at the primary diagnosis. Non-operative treatment has complications such as bone nonunion and the possibility of secondary neurological damage, while the timing, access and choice of surgical treatment are still controversial. Currently, there are no clinical practice guidelines for the treatment of AS combined with lower cervical fracture with or without dislocation. To this end, the Spinal Trauma Group of Orthopedics Branch of Chinese Medical Doctor Association organized experts to formulate Clinical guidelines for the treatment of ankylosing spondylitis combined with lower cervical fracture in adults ( version 2024) in accordance with the principles of evidence-based medicine, scientificity and practicality, in which 11 recommendations were put forward in terms of the diagnosis, imaging evaluation, typing and treatment, etc, to provide guidance for the diagnosis and treatment of AS combined with lower cervical fracture.
6.Clinical phenotype and genetic analysis of a rare case with 6p duplication and terminal deletion syndrome
Yanhong YU ; Jian LU ; Hong LI ; Yingying GAO ; Xia YE ; Xuzhuo ZHANG ; Jingtian LU ; Juan QIU
Chinese Journal of Medical Genetics 2024;41(9):1117-1123
Objective:To explore the genetic basis for a child with developmental delay and intellectual deficit (DD/ID).Methods:A child who was admitted to the Maternal and Child Health Care Hospital of Longhua District of Shenzhen City on June 3, 2023 due to DD/ID, craniofacial malformations, and recurrent infections of upper respiratory tract was selected as the study subject. G-banded chromosomal karyotyping was carried out for the child and her parents. Low-depth genome-wide copy number variation sequencing (CNV-seq) and chromosomal microarray analysis (CMA) were used to screen for genome-wide copy number variation (CNV), and fluorescence in situ hybridization (FISH) was used to verify the origin of candidate CNV. This study was approved by the Maternal and Child Health Care Hospital of Longhua District of Shenzhen City(Ethics No. 2023052504). Results:The child, an 8-year-old girl, had featured unexplained growth and intellectual development delay, multiple craniofacial malformations, and recurrent infections of the upper respiratory tract. She was found to have a karyotype of 46, XX, der(6)add(6)(q23), while both of her parents were normal. Both CNV-seq and CMA showed that the child has harbored a 21.38 Mb interstitial duplication at 6p25.3p22.3 and a 0.78 Mb terminal deletion at 6p25. FISH verified that both the duplication and deletion had occurred de novo. Conclusion:The abnormal phenotype of the child may be attributed to the 6p duplication and terminal deletion.
7.Chinese expert consensus on the diagnosis and treatment of traumatic supraorbital fissure syndrome (version 2024)
Junyu WANG ; Hai JIN ; Danfeng ZHANG ; Rutong YU ; Mingkun YU ; Yijie MA ; Yue MA ; Ning WANG ; Chunhong WANG ; Chunhui WANG ; Qing WANG ; Xinyu WANG ; Xinjun WANG ; Hengli TIAN ; Xinhua TIAN ; Yijun BAO ; Hua FENG ; Wa DA ; Liquan LYU ; Haijun REN ; Jinfang LIU ; Guodong LIU ; Chunhui LIU ; Junwen GUAN ; Rongcai JIANG ; Yiming LI ; Lihong LI ; Zhenxing LI ; Jinglian LI ; Jun YANG ; Chaohua YANG ; Xiao BU ; Xuehai WU ; Li BIE ; Binghui QIU ; Yongming ZHANG ; Qingjiu ZHANG ; Bo ZHANG ; Xiangtong ZHANG ; Rongbin CHEN ; Chao LIN ; Hu JIN ; Weiming ZHENG ; Mingliang ZHAO ; Liang ZHAO ; Rong HU ; Jixin DUAN ; Jiemin YAO ; Hechun XIA ; Ye GU ; Tao QIAN ; Suokai QIAN ; Tao XU ; Guoyi GAO ; Xiaoping TANG ; Qibing HUANG ; Rong FU ; Jun KANG ; Guobiao LIANG ; Kaiwei HAN ; Zhenmin HAN ; Shuo HAN ; Jun PU ; Lijun HENG ; Junji WEI ; Lijun HOU
Chinese Journal of Trauma 2024;40(5):385-396
Traumatic supraorbital fissure syndrome (TSOFS) is a symptom complex caused by nerve entrapment in the supraorbital fissure after skull base trauma. If the compressed cranial nerve in the supraorbital fissure is not decompressed surgically, ptosis, diplopia and eye movement disorder may exist for a long time and seriously affect the patients′ quality of life. Since its overall incidence is not high, it is not familiarized with the majority of neurosurgeons and some TSOFS may be complicated with skull base vascular injury. If the supraorbital fissure surgery is performed without treatment of vascular injury, it may cause massive hemorrhage, and disability and even life-threatening in severe cases. At present, there is no consensus or guideline on the diagnosis and treatment of TSOFS that can be referred to both domestically and internationally. To improve the understanding of TSOFS among clinical physicians and establish standardized diagnosis and treatment plans, the Skull Base Trauma Group of the Neurorepair Professional Committee of the Chinese Medical Doctor Association, Neurotrauma Group of the Neurosurgery Branch of the Chinese Medical Association, Neurotrauma Group of the Traumatology Branch of the Chinese Medical Association, and Editorial Committee of Chinese Journal of Trauma organized relevant experts to formulate Chinese expert consensus on the diagnosis and treatment of traumatic supraorbital fissure syndrome ( version 2024) based on evidence of evidence-based medicine and clinical experience of diagnosis and treatment. This consensus puts forward 12 recommendations on the diagnosis, classification, treatment, efficacy evaluation and follow-up of TSOFS, aiming to provide references for neurosurgeons from hospitals of all levels to standardize the diagnosis and treatment of TSOFS.
8.Clinical application value of single pass scanning using multi-slice spiral CT for polytrauma patients
Gang WANG ; Ying ZHANG ; Teng TANG ; Hongyang DAI ; Nan WANG ; Mimi QIU ; Hongwei XU ; Fangfang XIA ; Xinglin XIANG ; Jian LI
Chinese Journal of Radiological Medicine and Protection 2024;44(8):693-698
Objective:To explore the clinical application value of single pass scanning using muti-slice spiral CT for polytrauma patients.Methods:Totally 60 polytrauma patients treated from January to November in 2023 were randomly enrolled in this study. They were categorized into an experimental group and a control group using a random number table, with 30 patients in each group. The patients in the experimental group underwent single pass scaning for the head, neck, chest, and abdomen, whereas those in the control group receiving separate scanning for various parts. Then, the noise, signal-to-noise ratio (SNR), and contrast-to-noise (CNR) of the CT images of both groups were recorded. Furthermore, the objective and subjective evaluation, volume CT dose index (CTDI vol), effective dose ( E), scanning time, and scan ranges of the images were compared between both groups. Results:Compared to the control group, the test group exhibited lower SNR of the head ( t = -5.47, P < 0.05) and higher SNR and CNR of the chest scans ( t = -5.95, -6.15, P < 0.05). Furthermore, the test group demonstrated decreased ED, CTDIvol, scanning time, and scan range, which dropped from 18.53 mSv to 13.81 mSv ( t = 3.29, P < 0.001), from 15.77 mGy to 10.59 mGy ( t = 4.48, P< 0.001), from 31.68 s to 10.97 s ( t = 6.95, P < 0.001), and from 64.92 cm to 45.21 cm ( t = 9.05, P < 0.001), respectively compared to the control group. Conclusions:Single pass CT scanning can reduce E, scanning time, and scan range in the treatment of polytrauma patients while ensuring the high quality of CT images, thus warranting wide clinical applications.
9.Significance of 18F-PI-2620 PET imaging for diagnosing tau protein deposition in patients with different cognitive disorders alongside cognitive correlation analysis
Gan HUANG ; Yan ZHANG ; Cheng WANG ; Mei XIN ; Hongda SHAO ; Yue WANG ; Liangrong WAN ; Ju QIU ; Qun XU ; Jianjun LIU ; Xia LI ; Chenpeng ZHANG
Chinese Journal of Nuclear Medicine and Molecular Imaging 2024;44(5):273-278
Objective:To evaluate the values of 18F-PI-2620 PET/CT brain imaging with SUV ratio (SUVR) in the assessment of tau protein deposition in the brain of patients with different cognitive disorders and its correlation with cognition. Methods:This was a cross-sectional study. From December 2019 to November 2022, a total of 67 subjects including 54 patients with Alzheimer′s disease (AD; 21 males, 33 females, age (68.6±7.8) years), 7 patients with mild cognitive impairment (MCI; 1 male, 6 females, age (63.1±11.2) years) and 6 healthy controls (HC; 4 males, 2 females, age (69.0±5.8) years) were enrolled retrospectively in Renji Hospital. All participants were examined by 18F-PI-2620 PET/CT. SUVRs of brain regions were obtained, including frontal lobe, temporal lobe, occipital lobe, parietal lobe, insular lobe, whole brain, as well as 10 independent brain ROIs (amygdala, orbitofrontal cortex, cingulate gyrus, superior occipital gyrus, superior parietal gyrus, inferior angular gyrus, precuneus, inferior temporal gyrus, entorhinal cortex and parahippocampal gyrus), with inferior cerebellum cortex as the reference region. All participants were estimated by cognitive scales(mini-mental state examination (MMSE) and Montreal cognitive assessment (MoCA)). One-way analysis of variance and the least significant difference t test were used to compare the differences of SUVR in each brain region among HC, MCI and AD groups. ROC curve analysis was used to determine the optimal cut-off values of SUVR in each brain region for the differential diagnosis of AD-MCI and AD-HC. Pearson correlation analysis was employed to examine the correlations of SUVR with cognitive scale scores. Results:The SUVR of whole brain was 1.40±0.31 in AD group, 1.08±0.19 in MCI group, and 1.01±0.12 in HC group. SUVR analysis in the whole brain and each brain region could distinguish AD from HC, AD from MCI ( F values: 1.76-10.09, t values: 2.98-7.47, all P<0.05), but could not distinguish HC from MCI ( t values: 0.17-1.53, all P>0.05). ROC curve analysis showed that the best cut-off value of SUVR was 1.18 for whole brain (AUC=0.89), 1.13 for amygdala (AUC=0.94) and 1.26 for parahippocampal gyrus (AUC=0.94) for differential diagnosis of AD and HC, which was 1.06 for whole brain (AUC=0.82), 1.18 for amygdala (AUC=0.88) and 1.28 (AUC=0.88) for infratemporal gyrus to differential diagnosis of AD and MCI. SUVRs of the whole brain, frontal, occipital, parietal, temporal and insula were significantly negatively correlated with MMSE and MoCA cognitive scale scores ( r values: from -0.64 to -0.40, all P<0.05). Conclusions:SUVR quantitative analysis in 18F-PI-2620 PET imaging can assist the differential diagnosis of AD and HC, AD and MCI. The SUVRs of whole brain and five lobes show negative correlations with MMSE and MoCA scores.
10.Diagnostic efficiency of 18F-FDG PET for Alzheimer′s disease in patients with memory impairment
Yan ZHANG ; Chenpeng ZHANG ; Gan HUANG ; Cheng WANG ; Mei XIN ; Hongda SHAO ; Yue WANG ; Liangrong WAN ; Ju QIU ; Qun XU ; Xia LI ; Jianjun LIU
Chinese Journal of Nuclear Medicine and Molecular Imaging 2024;44(12):712-717
Objective:To assess the diagnostic efficiency of 18F-FDG PET for Alzheimer′s disease (AD) in patients with memory impairment. Methods:A retrospective analysis was conducted on 96 patients (40 males, 56 females, age: 69.0(62.8, 74.0) years) initially diagnosed with memory impairment in Renji Hospital, School of Medicine, Shanghai Jiao Tong University between August 2019 and September 2023. The amyloid-tau-neurodegeneration (ATN) criteria, based on 18F-AV45+ 18F-PI-2620 PET/CT+ MRI imaging results, were used as the diagnostic standard for AD. Visual analysis (temporoparietal or posterior cingulate cortex (PCC) hypometabolism) and semi-quantitative analysis methods (PET-SCORE and NeuroQ software analysis (SUV ratio, SUVR)) were applied to evaluate the diagnostic efficiency of 18F-FDG PET imaging for AD. Diagnostic efficiencies of visual assessment and semi-quantitative parameters were compared by χ2 test. Additionally, Pearson correlation analysis was performed to examine the relationship between results of PET-SCORE and cognitive scales. Results:Of the 96 patients initially diagnosed with memory impairment, 61 were clinically diagnosed with AD, while 35 were non-AD patients. Visual assessment of temporoparietal hypometabolism showed the highest sensitivity (91.80%, 56/61), which was significantly different from the sensitivities of PET-SCORE (40.98%(25/61); χ2=29.03, P<0.001) and visual assessment of PCC hypometabolism (77.05%(47/61); χ2=5.82, P=0.016). While semi-quantitative assessment using PET-SCORE demonstrated the highest specificity (100%, 35/35), which was significantly different from the specificities of visual assessment methods (temporoparietal hypometabolism: 17.14%(6/35), χ2=27.03, P<0.001; PCC hypometabolism: 54.29%(19/35), χ2=14.06, P<0.001). PET-SCORE exhibited statistically significant correlations with Mini-Mental State Examination (MMSE), Montreal Cognitive Assessment (MoCA), and Activities of Daily Living (ADL) scores ( r values: -0.38, -0.36, 0.31, all P<0.01). Conclusions:Among patients initially diagnosed with memory impairment, visual assessment in 18F-FDG PET imaging analysis demonstrates higher sensitivity, while semi-quantitative analysis using PET-SCORE exhibits higher specificity. PET-SCORE shows statistically significant correlation with the severity of cognitive decline.

Result Analysis
Print
Save
E-mail