1.Research Progress of Circular RNA and Protein Ubiquitination Modification in Cancer
Qintian HUANG ; Chengnong GUAN
Cancer Research on Prevention and Treatment 2025;52(9):798-805
Circular RNAs (circRNAs) are a class of noncoding RNA molecules with a covalently enclosed circular structure and are more stable than linear RNAs. CircRNAs possess unique characteristics and biological functions, playing key roles in the occurrence and development, proliferation, metastasis, invasion, and drug resistance of various types of cancer. Protein ubiquitination modification regulates the stability and functions of proteins through the ubiquitin-proteasome system (UPS), and affecting tumor-related signal transduction pathways. Interactions between circRNAs and UPS in cancer have attracted considerable interest. They may be novel biomarkers for cancer therapy and potential targets for mitigating tumors’ drug resistance. This article systematically reviews the molecular mechanism and clinical translational potential of circRNAs and protein ubiquitination modification in cancer and discusses their application prospects in diagnosis, treatment prognosis and overcoming drug resistance.
2.Prediction model of portal pressure for HBV-related cirrhosis based on radiomics feature
Qintian TAN ; Kun ZHOU ; Yingjie AI ; Siyu JIANG ; Zekuan YU ; Ling WU ; Xiaoquan HUANG ; Shiyao CHEN
Journal of Chinese Physician 2022;24(5):658-661,666
Objective:In this study, the liver, spleen, and hepatic portal vein in the portal venous phase images of abdominal enhanced computed tomography (CT) are artificially segmented and annotated, and the radiomics features are extracted from them. A model for predicting portal pressure in patients with hepatitis B virus (HBV) related cirrhosis is constructed by combining radiomics features with clinical indicators.Methods:A total of 171 patients who had abdominal enhancement CT examination and trans-jugular hepatic venous pressure gradient (HVPG) measurement at the same time were enrolled from January 2016 to May 2020 in the Zhongshan Hospital Affiliated to Fudan University. The liver, spleen, and hepatic portal vein in the portal venous phase images of the CT were manually labeled by using ITK-SNAP 3.8 software. The radiomics features of these three sites were extracted using Python programming, and an HVPG prediction model was established.Results:A total of 171 patients was included in the study. The average age was (51.1±10.3)years, of which 134(78.4%) were males, and the average HVPG was 16.87±5.695. A total of 2 553 radiomics features were extracted from three sites of the portal venous phase images of abdominal enhanced CT in each patient. The 2 553 features extracted were screened using LASSO, and by combing with clinical features and radiomics features, the predictive model of HVPG was obtained: m_HVPG=31.622+ 0.028 8T×total bile acids-6.31(portal venous wavelet-LHH_glcm_ClusterShade)=0.253(portal venous wavelet-LHL_glszm_LargeAreaLowGrayLevelEmphasis)-20.9(spleen wavelet-LLH_glcm_Correlation)-0.000 127(liver original_shape_SurfaceArea)+ 2.79(liver wavelet-LLH_glcm_ClusterShade). The coefficient of determination R2 was 0.345. Conclusions:The study suggests that radiomics features of the liver, spleen, and portal venous combined with clinical features may be used as a non-invasive method to assess the portal pressure in patients with HBV-related cirrhosis.
3.Clinical study on early loading restoration of superhydrophilic implants
Wenmian HUANG ; Beibei ZHOU ; Wangcheng NI ; Qintian ZHU ; Jilan YU ; Renfei WANG
Chinese Journal of Stomatology 2021;56(2):164-169
Objective:To study the clinical effect of early loading restoration a superhydrophilic implant after 1 year, so as to provide reference evidence for clinical practice.Methods:A total of 41 patients with dental defects, including 20 males and 21 females [age (52.3±13.1) years old], were enrolled in the Department of VIP, Hangzhou Dental Hospital (Pinghai Hospital) from July 2017 to January 2019. A total of 74 superhydrophilic implants were implanted, including 27 maxillary implants and 47 mandiolar implants. All patients without bone augmentation or soft tissue transplantation, the maxilla was taken impression 4 weeks after implant implantation, with 6 weeks of loading, the mandible was taken impression 2 weeks after implant implantation, with 4 weeks of loading. The stability of the implant was measured by resonance frequency analyzer before implant implantation, impression and loading. Periapical radiograph were taken immediately after mold removal, immediately after loading and reexamination 1 year after loading, to measure and record the changes in the bone level of the mesial and distal margins of the implant.Results:No biological complications occurred in all implants before loading restoration, and the implant survival rate was 100%(74/74). In 2 cases, the implant stability quotient (ISQ) value of the implant at the mandibular site was lower than 65 at 2 weeks after surgery, and the restoration was delayed. The ISQ values of the other 72 implants at the time of implantation (75.22±4.32) were not significantly different from those at the time of modeling (75.13±4.23) ( P>0.05), but the ISQ values at the moment of weight loading (76.46±3.73) were significantly higher than those at modeling ( P<0.05). All the early loading implants were reviewed 1 year after early loading, and none of them were loose or fell off, and the implant survival rate was 100%(72/72). X-ray measurement and evaluation showed that after 1 year of early loading restoration, the mean marginal bone absorption of 72 implants was (0.18±0.06) mm, among which the mandibular was (0.17±0.06) mm and the maxillary was (0.19±0.06) mm, showing no statistical difference ( P>0.05). After 1 year of early loading restoration, the mean marginal bone absorption of 72 implants was (0.17±0.05) mm, including (0.17±0.06) mm for mandibular and (0.16±0.05) mm for maxillary, showing no statistical difference ( P>0.05). Conclusions:In the limited scope of this clinical study, it has been proved that early loading of superhydrophilic implant is a safe and feasible treatment scheme, and the bone resorption at the implant edge after long-term early loading restoration needs further follow-up study.

Result Analysis
Print
Save
E-mail