1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
6.Research progress in clinical application and mechanism of Sijunzi Decoction in the treatment of gastric cancer
Jingtao ZHAO ; Bo NING ; Meng XIAO ; Yue QIN ; Yanan LI ; Qiuyan YANG ; Haijuan XIAO
International Journal of Traditional Chinese Medicine 2024;46(3):395-399
		                        		
		                        			
		                        			As a classic prescription for invigorating spleen and replenishing qi, Sijunzi Decoction has a good clinical efficacy in the treatment of gastric cancer. It can improve chemotherapy resistance, reduce the toxic and side effects of chemotherapy, promote postoperative recovery, enhance immunity, improve the nutritional status of patients, improve the quality of life of patients and prevent precancerous lesions. Network pharmacology studies have shown that Sijunzi Decoction exerts anti-gastric cancer effects through multiple active ingredients, multiple targets and multiple pathways, and quercetin may be the main active component in Sijunzi Decoction to exert anti-gastric cancer effects. The main mechanisms of Sijunzi Decoction in the treatment of gastric cancer include regulating the expression of cell cycle and apoptosis-related gene proteins, and inhibiting the proliferation, migration, invasion and gastric cancer stem cell characteristics of gastric cancer cells.
		                        		
		                        		
		                        		
		                        	
7.Effects of Maxing Shigan Decoction on IL-6/STAT3 Signaling Pathway and TRPV1 Receptor in Rats with Cough Variant Asthma
Qian YANG ; Bo JIANG ; Qin-Guo SUN ; Kun LYU ; Meng LUO ; Tian-Hui HUANG
Journal of Guangzhou University of Traditional Chinese Medicine 2024;41(3):729-735
		                        		
		                        			
		                        			Objective To investigate the therapeutic effects and mechanisms of Maxing Shigan Decoction on cough variant asthma(CVA)rats.Methods Sixty rats were randomly divided into normal group,model group,low and high dose groups of Maxing Shigan Decoction,and high-dose of Maxing Shigan Decoction + signal transducer and activator of transcription 3(STAT3)activator Colivelin(Col)group,12 rats in each group.Except for the normal group,the CVA model was constructed by intraperitoneal injection of ovalbumin combined with moxa fumigation in all other groups of rats.After the corresponding treatment,the rats were observed for signs and cough counts,airway resistance(RE)was detected by pulmonary function meter,eosinophils(EOS)were counted by Diff-Quik staining,histopathological features of the lungs and bronchial tubes were observed by hematoxylin-eosin(HE)staining method,and the lung tissues were detected by enzyme-linked immunosorbent assay(ELISA)for monocyte chemotactic protein 1(MCP-1),and tumor necrosis factor α(TNF-α),and the protein expression levels of interleukin 6(IL-6),STAT3,and transient receptor potential vanilloid-1 channel(TRPV1)were detected by Western Blot.Results Compared with the normal group,rats in the model group showed obvious asthma symptoms,severe inflammatory cell infiltration was seen in the lung tissue,bronchial epithelial cell necrosis,ciliated adhesion,mucus,and RE,EOS number,MCP-1 and TNF-α contents,and protein expression levels of IL-6,STAT3,TRPV1 were elevated(P<0.05);compared with the model group,rats in the low-and high-dose groups of Maxing Shigan Decoction showed significant improvement in asthma symptoms,reduction in lung and bronchial injury,and dose-dependent reduction in RE,EOS number,MCP-1 and TNF-α contents,and protein expression levels of IL-6,STAT3,and TRPV1(P<0.05);compared with the high-dose group of Maxing Shigan Decoction,the rats in the high-dose Maxing Shigan Decoction+Col group showed increased asthma,increased lung and bronchial injury,and increased RE,EOS number,MCP-1 and TNF-α contents,and protein expression levels of IL-6,STAT3,and TRPV1(P<0.05).Conclusion Maxing Shigan Decoction can effectively improve cough variant asthma in rats,and its mechanism is related to the inhibition of IL-6/STAT3 signaling pathway and the high expression of TRPV1.
		                        		
		                        		
		                        		
		                        	
8.Effects of Rosa roxburghii Radix on ulcerative colitis in rats based on pyroptosis and neutrophil extracellular traps
Yi-Ping YAN ; Yun-Zhi CHEN ; Qian LI ; Bo-Yang CHEN ; Zhi-Liang FAN ; Shuai CHEN ; Yi-Hui CHAI ; Zhong QIN
Chinese Traditional Patent Medicine 2024;46(3):780-788
		                        		
		                        			
		                        			AIM To explore the effects of Rosa roxburghii Radix on ulcerative colitis(UC)in rats based on pyroptosis and neutrophil extracellular traps(NETs).METHODS Rats were randomly divided into the normal group and the model group.The successfully established UC rat models by trinitrobenzene sulfonic acid(TNBS)/ethanol enema were then randomly divided into the model group,the sulfasalazine group(0.3 g/kg)and the low,medium and high dose R.roxburghii Radix groups(2,4,8 g/kg),followed by dosing of corresponding drugs by gavage.21 days later,the rats had their disease activity index(DAI)score calculated;their pathological changes of colon tissue observed by HE staining;their levels of serum interleukin(IL)-18,IL-1β and myeloperoxidase(MPO)detected by ELISA;and their protein expressions of NE,MPO,NLRP3,caspase-1 and GSDMD in colon tissue detected by Western blot and immunohistochemistry.RESULTS Compared with the normal group,the model group displayed increased DAI score(P<0.01),increased serum levels of IL-1β,IL-18 and MPO(P<0.01),and increased protein expressions of NE,MPO,caspase-1,NLRP3 and GSDMD in colon tissue(P<0.01).Compared with the model group,the groups intervened with sulfasalazine,or medium,or high dose R.roxburghii Radix demonstrated with decreased DAI scores(P<0.05,P<0.01),decreased serum levels of IL-1β,IL-18 and MPO(P<0.01),and decreased protein expressions of NE,MPO,caspase-1,NLRP3 and GSDMD in colon tissue(P<0.05,P<0.01).CONCLUSION R.roxburghii Radix may alleviate the inflammatory reaction in a rat model of UC and improve its pathological injury of colon via regulating pyroptosis and NETs.
		                        		
		                        		
		                        		
		                        	
9.Prognostic value of Doppler ultrasound combined with Cyfra21-1 and sIL-2R in cervical lymph node metastasis of thyroid micropapillary carcinoma
Jin TANG ; Runqin MIAO ; Li YANG ; Yanchao QIN ; Zhaojie WANG ; Bo ZHANG
Chinese Journal of Endocrine Surgery 2024;18(5):691-695
		                        		
		                        			
		                        			Objective:To investigate the predictive value of Doppler ultrasonography combined with cytokeratin fragment 19 (Cyfra21-1) and soluble interleukin-2 receptor (sIL-2R) in cervical lymph node metastasis of thyroid micropapillary carcinoma.Methods:102 patients with minimal papillary carcinoma of thyroid confirmed by surgery and pathology admitted to Ultrasound Department, Shanxi Cancer Hospital from Aug. 2020 to Aug. 2023 were selected and treated with thyroidectomy plus central region and at least one cervical lymph node dissection. Among them, There were 24 cases in the LLNM group and 78 cases in the non-LLNM group.Results:There were significant differences in age, shape, nodular and capsule contact area, tumor shape aspect ratio > 1, blood flow, microcalcification, serum Cyfra21-1 and serum sIL-2R levels between the two groups (Cyfra21-1: P<0.001, sIL-2R: P=0.001). Logistic regression analysis showed that age ≥50 years old ( OR=0.443, 95% CI: 0.217-0.904), microcalcification ( OR=2.787, 95% CI: 1.491-5.208), Cyfra21-1>3.3ng/ml ( OR=3.117, 95% CI: 1.404-6.922) and sIL-2R > 110.45pmol/L ( OR=3.408, 95% CI: 1.473-7.884) were independent risk factors for cervical lymph node metastasis in PTMC patients ( P < 0.05). The ROC curve results showed that the area under the curve of cervical lymph node metastasis predicted by Doppler ultrasound combined with Cyfra21-1 and sIL-2R was 0.82, and the sensitivity and specificity were 83.67% and 70.56%, respectively. Conclusions:The calcification features of Doppler ultrasound and the elevation of serum Cyfra21-1 and sIL-2R are closely related to cervical lymph node metastasis of thyroid micropapillary carcinoma. The combination of Doppler ultrasound with serum Cyfra21-1 and sIL-2R has important reference value in predicting cervical lymph node metastasis.
		                        		
		                        		
		                        		
		                        	
10.TCM Guidelines for Diagnosis and Treatment of Chronic Cough in Children
Xi MING ; Liqun WU ; Ziwei WANG ; Bo WANG ; Jialin ZHENG ; Jingwei HUO ; Mei HAN ; Xiaochun FENG ; Baoqing ZHANG ; Xia ZHAO ; Mengqing WANG ; Zheng XUE ; Ke CHANG ; Youpeng WANG ; Yanhong QIN ; Bin YUAN ; Hua CHEN ; Lining WANG ; Xianqing REN ; Hua XU ; Liping SUN ; Zhenqi WU ; Yun ZHAO ; Xinmin LI ; Min LI ; Jian CHEN ; Junhong WANG ; Yonghong JIANG ; Yongbin YAN ; Hengmiao GAO ; Hongmin FU ; Yongkun HUANG ; Jinghui YANG ; Zhu CHEN ; Lei XIONG
Journal of Nanjing University of Traditional Chinese Medicine 2024;40(7):722-732
		                        		
		                        			
		                        			Following the principles of evidence-based medicine,in accordance with the structure and drafting rules of standardized documents,based on literature research,according to the characteristics of chronic cough in children and issues that need to form a consensus,the TCM Guidelines for Diagnosis and Treatment of Chronic Cough in Children was formulated based on the Delphi method,expert discussion meetings,and public solicitation of opinions.The guideline includes scope of application,terms and definitions,eti-ology and diagnosis,auxiliary examination,treatment,prevention and care.The aim is to clarify the optimal treatment plan of Chinese medicine in the diagnosis and treatment of this disease,and to provide guidance for improving the clinical diagnosis and treatment of chronic cough in children with Chinese medicine.
		                        		
		                        		
		                        		
		                        	
            
Result Analysis
Print
Save
E-mail