1.Principles, technical specifications, and clinical application of lung watershed topography map 2.0: A thoracic surgery expert consensus (2024 version)
Wenzhao ZHONG ; Fan YANG ; Jian HU ; Fengwei TAN ; Xuening YANG ; Qiang PU ; Wei JIANG ; Deping ZHAO ; Hecheng LI ; Xiaolong YAN ; Lijie TAN ; Junqiang FAN ; Guibin QIAO ; Qiang NIE ; Mingqiang KANG ; Weibing WU ; Hao ZHANG ; Zhigang LI ; Zihao CHEN ; Shugeng GAO ; Yilong WU
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(02):141-152
With the widespread adoption of low-dose CT screening and the extensive application of high-resolution CT, the detection rate of sub-centimeter lung nodules has significantly increased. How to scientifically manage these nodules while avoiding overtreatment and diagnostic delays has become an important clinical issue. Among them, lung nodules with a consolidation tumor ratio less than 0.25, dominated by ground-glass shadows, are particularly worthy of attention. The therapeutic challenge for this group is how to achieve precise and complete resection of nodules during surgery while maximizing the preservation of the patient's lung function. The "watershed topography map" is a new technology based on big data and artificial intelligence algorithms. This method uses Dicom data from conventional dose CT scans, combined with microscopic (22-24 levels) capillary network anatomical watershed features, to generate high-precision simulated natural segmentation planes of lung sub-segments through specific textures and forms. This technology forms fluorescent watershed boundaries on the lung surface, which highly fit the actual lung anatomical structure. By analyzing the adjacent relationship between the nodule and the watershed boundary, real-time, visually accurate positioning of the nodule can be achieved. This innovative technology provides a new solution for the intraoperative positioning and resection of lung nodules. This consensus was led by four major domestic societies, jointly with expert teams in related fields, oriented to clinical practical needs, referring to domestic and foreign guidelines and consensus, and finally formed after multiple rounds of consultation, discussion, and voting. The main content covers the theoretical basis of the "watershed topography map" technology, indications, operation procedures, surgical planning details, and postoperative evaluation standards, aiming to provide scientific guidance and exploration directions for clinical peers who are currently or plan to carry out lung nodule resection using the fluorescent microscope watershed analysis method.
2.Endovascular Treatment for Acute Posterior Circulation Tandem Lesions: Insights From the BASILAR and PERSIST Registries
Wei LI ; Mohamed F. DOHEIM ; Zhongming QIU ; Tan WANG ; Zhibin CHEN ; Wenjie ZI ; Qingwu YANG ; Haitao GUAN ; Hongyu QIAO ; Wenhua LIU ; Wei HU ; Xinfeng LIU ; Jinbo HUANG ; Zhongkui HAN ; Zhonglun CHEN ; Zhenqiang ZHAO ; Wen SUN ; Raul G. NOGUEIRA
Journal of Stroke 2025;27(1):75-84
Background:
and Purpose Limited evidence exists on the effectiveness of endovascular treatment (EVT) for acute posterior circulation tandem lesion (PCTL). This study aimed to explore the role of extracranial vertebral artery (VA) stenting in patients with PCTL stroke undergoing EVT.
Methods:
Individual patient data were pooled from the BASILAR (EVT for Acute Basilar Artery Occlusion Study) and PERSIST (Posterior Circulation Ischemic Stroke) registries. Patients with PCTLs who underwent EVT were included in the present cohort and divided into the stenting and nonstenting groups based on the placement of extracranial VA stents. The primary efficacy outcome was the modified Rankin Scale (mRS) scores at 90 days and 1 year. Safety outcomes included 24-hour symptomatic intracranial hemorrhage (sICH) and all-cause mortality at 90 days and 1 year post-surgery.
Results:
A combined dataset of 1,320 patients with posterior circulation artery occlusion, including 263 (19.9%) with tandem lesions, of whom 217 (median age, 65 years; 82.9% male) met the inclusion criteria for the analysis. The stenting group had 84 (38.7%) patients, while the non-stenting group had 133 (61.3%). After adjustment for the potential confounders, extracranial VA stenting was associated with favorable shifts in mRS scores at both 90 days (adjusted common odds ratio [OR], 2.30; 95% confidence interval [CI], 1.23–4.28; P<0.01) and 1 year (adjusted OR [aOR], 2.04; 95% CI [1.05–3.97]; P=0.04), along with lower rate of mortality at both 90 days (aOR, 0.45; 95% CI [0.21–0.93]; P=0.01) and 1 year (aOR, 0.36; 95% CI [0.16–0.79]; P=0.01), with no significant difference in sICH incidence (aOR, 0.35; 95% CI [0.06–1.98]; P=0.24).
Conclusion
Extracranial VA stenting during EVT may improve functional outcomes and reduce mortality in patients with PCTL strokes.
3.Endovascular Treatment for Acute Posterior Circulation Tandem Lesions: Insights From the BASILAR and PERSIST Registries
Wei LI ; Mohamed F. DOHEIM ; Zhongming QIU ; Tan WANG ; Zhibin CHEN ; Wenjie ZI ; Qingwu YANG ; Haitao GUAN ; Hongyu QIAO ; Wenhua LIU ; Wei HU ; Xinfeng LIU ; Jinbo HUANG ; Zhongkui HAN ; Zhonglun CHEN ; Zhenqiang ZHAO ; Wen SUN ; Raul G. NOGUEIRA
Journal of Stroke 2025;27(1):75-84
Background:
and Purpose Limited evidence exists on the effectiveness of endovascular treatment (EVT) for acute posterior circulation tandem lesion (PCTL). This study aimed to explore the role of extracranial vertebral artery (VA) stenting in patients with PCTL stroke undergoing EVT.
Methods:
Individual patient data were pooled from the BASILAR (EVT for Acute Basilar Artery Occlusion Study) and PERSIST (Posterior Circulation Ischemic Stroke) registries. Patients with PCTLs who underwent EVT were included in the present cohort and divided into the stenting and nonstenting groups based on the placement of extracranial VA stents. The primary efficacy outcome was the modified Rankin Scale (mRS) scores at 90 days and 1 year. Safety outcomes included 24-hour symptomatic intracranial hemorrhage (sICH) and all-cause mortality at 90 days and 1 year post-surgery.
Results:
A combined dataset of 1,320 patients with posterior circulation artery occlusion, including 263 (19.9%) with tandem lesions, of whom 217 (median age, 65 years; 82.9% male) met the inclusion criteria for the analysis. The stenting group had 84 (38.7%) patients, while the non-stenting group had 133 (61.3%). After adjustment for the potential confounders, extracranial VA stenting was associated with favorable shifts in mRS scores at both 90 days (adjusted common odds ratio [OR], 2.30; 95% confidence interval [CI], 1.23–4.28; P<0.01) and 1 year (adjusted OR [aOR], 2.04; 95% CI [1.05–3.97]; P=0.04), along with lower rate of mortality at both 90 days (aOR, 0.45; 95% CI [0.21–0.93]; P=0.01) and 1 year (aOR, 0.36; 95% CI [0.16–0.79]; P=0.01), with no significant difference in sICH incidence (aOR, 0.35; 95% CI [0.06–1.98]; P=0.24).
Conclusion
Extracranial VA stenting during EVT may improve functional outcomes and reduce mortality in patients with PCTL strokes.
4.Endovascular Treatment for Acute Posterior Circulation Tandem Lesions: Insights From the BASILAR and PERSIST Registries
Wei LI ; Mohamed F. DOHEIM ; Zhongming QIU ; Tan WANG ; Zhibin CHEN ; Wenjie ZI ; Qingwu YANG ; Haitao GUAN ; Hongyu QIAO ; Wenhua LIU ; Wei HU ; Xinfeng LIU ; Jinbo HUANG ; Zhongkui HAN ; Zhonglun CHEN ; Zhenqiang ZHAO ; Wen SUN ; Raul G. NOGUEIRA
Journal of Stroke 2025;27(1):75-84
Background:
and Purpose Limited evidence exists on the effectiveness of endovascular treatment (EVT) for acute posterior circulation tandem lesion (PCTL). This study aimed to explore the role of extracranial vertebral artery (VA) stenting in patients with PCTL stroke undergoing EVT.
Methods:
Individual patient data were pooled from the BASILAR (EVT for Acute Basilar Artery Occlusion Study) and PERSIST (Posterior Circulation Ischemic Stroke) registries. Patients with PCTLs who underwent EVT were included in the present cohort and divided into the stenting and nonstenting groups based on the placement of extracranial VA stents. The primary efficacy outcome was the modified Rankin Scale (mRS) scores at 90 days and 1 year. Safety outcomes included 24-hour symptomatic intracranial hemorrhage (sICH) and all-cause mortality at 90 days and 1 year post-surgery.
Results:
A combined dataset of 1,320 patients with posterior circulation artery occlusion, including 263 (19.9%) with tandem lesions, of whom 217 (median age, 65 years; 82.9% male) met the inclusion criteria for the analysis. The stenting group had 84 (38.7%) patients, while the non-stenting group had 133 (61.3%). After adjustment for the potential confounders, extracranial VA stenting was associated with favorable shifts in mRS scores at both 90 days (adjusted common odds ratio [OR], 2.30; 95% confidence interval [CI], 1.23–4.28; P<0.01) and 1 year (adjusted OR [aOR], 2.04; 95% CI [1.05–3.97]; P=0.04), along with lower rate of mortality at both 90 days (aOR, 0.45; 95% CI [0.21–0.93]; P=0.01) and 1 year (aOR, 0.36; 95% CI [0.16–0.79]; P=0.01), with no significant difference in sICH incidence (aOR, 0.35; 95% CI [0.06–1.98]; P=0.24).
Conclusion
Extracranial VA stenting during EVT may improve functional outcomes and reduce mortality in patients with PCTL strokes.
5.Three-dimensional Printing of Inertial Microchannel with Complex Cross-section and Characterization of Particle Inertial Focusing
Qiao GU ; Xin-Jie ZHANG ; Yao LIU ; Yang BAO ; Hang-Jie ZHU ; Ya-Wei CHEN
Chinese Journal of Analytical Chemistry 2024;52(1):93-101
Projection micro stereolithography three-dimensional(3D)printing method was proposed in this study to fabricate complex microchannels of combined cross-sections.By using 3D printing and polydimethylsiloxane(PDMS)replication methods,two inertial microfluidic chips of three-step and five-step cross-sections were fabricated,and the dimension precisions of the microchannels were controlled within 20 μm.Using the microfluidic chips,the movements of two fluorescent polystyrene particles with diameters of 10 and 6 μm in the stepped channels were investigated.In addition,numerical simulations were applied to demonstrate the inertial focusing mechanisms of particles in the channels.It was found that 10-μm particles had three equilibrium positions in the three-step channel,which located at the inner walls of the three steps,respectively,and most particles focused at the inner step.The 6-μm particles also had three equilibrium positions in the three-step channel.However,the particles migrated to the middle and the outer steps under high flow rates.In the five-step channel,when the flow rate was increased gradually,10-μm particles had a single and two equilibrium positions,respectively,and the particles migrated towards the inner channel wall under high flow rates.In comparison to 10-μm particles,6-μm particles had two stable equilibrium positions in the five-step channel at all flow rate range.It could be concluded that the quantity,shape and strength of the secondary flow vortex could be altered by changing structure of the combined cross-section,thus the equilibrium positions and quantities of the focusing particles could be also regulated.The research outcome might provide new insights for precise cell inertial manipulation and promote the application and development of inertial microfluidic technology in biomedical and other fields.
6.Finite element analysis of osteoporosis in proximal femur after cannulated screw fixation for femoral neck fracture
Xiaofeng XUE ; Yongkang WEI ; Xiaohong QIAO ; Yuyong DU ; Jianjun NIU ; Lixin REN ; Huifeng YANG ; Zhimin ZHANG ; Yuan GUO ; Weiyi CHEN
Chinese Journal of Tissue Engineering Research 2024;28(6):862-867
BACKGROUND:After the internal fixation of cannulated screws in femoral neck fractures,because the affected limb is often unable to bear weight in the short term and the implants with high stiffness have a stress shielding effect on the fracture end,it is easy to cause osteoporosis of the affected limb and changes in the biomechanical distribution of the proximal femur,the incidence of osteonecrosis of the femoral head is high after surgery.At present,few studies have been conducted on the biomechanical effects of osteoporosis at the proximal end of the femur occurring after femoral neck fracture surgery on femoral neck fracture treated with cannulated screws. OBJECTIVE:Using finite element analysis,to investigate the biomechanical effects of osteoporosis occurring after femoral neck fracture surgery on femoral neck fracture treated with cannulated screws and explore the role of biomechanical factors in osteonecrosis of the femoral head. METHODS:Based on the obtained CT scan data of the femur in a patient with a femoral neck fracture,a proximal femoral model for internal fixation for femoral neck fracture was established by Mimics 19.0,3-Matic,UG 11.0,Hypermesh 14.0,and Abaqus software.One finite element model of the proximal femur without osteoporosis and three finite element models of the proximal femur with osteoporosis were analyzed using Abaqus software.The stress,contact pressure,displacement peak and cloud map under different components of the four models were measured and analyzed,and the internal stress changes and distribution of the femoral head were compared and analyzed. RESULTS AND CONCLUSION:The stresses and contact pressures of the femoral head and lower anterior cannulated screws varied more with the degree of osteoporosis.The peak displacement of the four models increased slowly with the degree of osteoporosis.By one-way analysis of variance,there was no significant effect of the degree of osteoporosis on the peak stress,contact pressure,and displacement of the different components.The internal stress distribution of the femoral head changed with the degree of osteoporosis.Changes in the biomechanical environment of the proximal femur have an important impact on osteonecrosis of the femoral head.
7.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
8.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
9.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
10.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.

Result Analysis
Print
Save
E-mail