1.Design of a novel, modular, mouth retractor: A concept testing study.
Miguel Sandino O. ALJIBE ; Airene Maria C. APACIBLE ; Philip B. FULLANTE
Acta Medica Philippina 2025;59(Early Access 2025):1-10
BACKGROUND AND OBJECTIVES
Mouth retractors are essential in ensuring efficient yet safe exposure of the oral cavity and oropharynx. However, when applied improperly or haphazardly, retractors can cause tissue injuries and compromise patient safety. In addition, there are gaps in the usability of existing designs. This study aimed to identify the issues encountered by otorhinolaryngology surgeons in the use of commercially available mouth retractors, design and fabricate an improved retractor, and explore the use of additive manufacturing (popularly known as 3D printing) for retractor prototyping.
METHODSThe study used the United States Food and Drug Administration (US FDA) Design Control as its framework. End-user requirements from otorhinolaryngologists were collected through key informant interviews. Results were organized into a Design Input template which was used to guide the design and development process. Prototype designs were iteratively created using computer-aided design software and 3D printing. Once design specifications were satisfied, a beta prototype was fabricated and given to another cohort of otorhinolaryngologists. The participants assessed the usability of the beta prototype. System Usability Scale (SUS) was used to quantify participant's feedback.
RESULTSFive designs were created in the course of the study. The final prototype was fabricated using a Stereolithography (SLA) 3D printer. Several features were developed to address user requirements. The primary modification was to make the retractor modular to facilitate easier and shorter mounting and assembly. Gingival injury was addressed with the replacement of the maxillary alveolus hook with support bars. Five participants evaluated the beta prototype which received a mean SUS score of 75, well above the 50th percentile threshold.
CONCLUSIONThis study demonstrates the applicability of the US FDA Design Control Process in the local setting to improve the mouth retractor design. Clinical and ergonomic issues were identified and design solutions were proposed and some have been implemented in a low-fidelity prototype. Results of the small-scale usability test suggest that the present form factor can be the basis for further iterations. Future studies can implement the proposed features to address other clinical and ergonomic needs.
Human ; 3d Printing ; Printing, Three-dimensional ; Devices, Medical ; Equipment And Supplies
2.Development of 3D printed gastroretentive floating tablet devices for metronidazole
Althea C. Gundran ; Jocelyn S. Bautista-Palacpac
Philippine Journal of Health Research and Development 2024;28(2):40-48
Background:
In this study, 3D printed floating tablet devices for Metronidazole (MTZ) were developed to prolong its exposure with
Helicobacter pylori and eradicate it from causing peptic ulcer
Objectives:
To utilize Quality by Design (QbD) in the development of the tablet devices through Fused Deposition Modelling (FDM)
3D printing. This aimed to develop and construct optimized design dimensions of tablet devices subject for characterization.
Methodology:
Tablet designs were established using QbD, Design Failure Mode Effect and Analysis (DFMEA) and 2 factorial
design. Four floating tablets devices were developed through FDM 3D printing using Polyvinyl alcohol (PVA) filament.
Characterization tests determined their dimensions, density, floating mechanism, in vitro dissolution rate, drug release kinetics,
surface morphology, infill and thermal characteristics. Significance of the QbD model was also assessed.
Results:
Density of all devices were less than 1.004 g/cm . The floating Lag time (FLT) showed instant floatation and Total Floating
Time (TFT) lasted for an average of 1 hour. Drug release kinetics show Korsmeyer-Peppas kinetics. Thermal characteristics fall within
o o
186.12 C-187.27 C. 3D CTX-ray results show accuracy of printing 3D renders. Tablet device 3 exhibited the best surface morphology,
longest floating time and slowest drug release.
Conclusion
The study successfully developed 3D printed floating tablet devices for Metronidazole with sustained release
mechanism. Thus, utilizing QbD in pre-formulation studies using novel technology is essential in optimizing drug dosage forms. Plots
from Design Expert Software show the significant design models.
Printing, Three-Dimensional
3.Predation in publishing
Journal of the Philippine Dermatological Society 2024;33(1):1-2
The road to publication can seem long and daunting. Further, access to published work is often limited to larger institutions that can afford expensive journal subscription fees. Gold open-access publications aimed to change the landscape of evidence-based science, allowing papers to be widely accessible without a subscription, often requiring an article processing fee paid by the author or institution. Regardless of the access model, reputable journals are expected to adhere to the publishing code of ethics and provide transparency in the peer review process. While the latter can significantly increase the length of processing time through multiple revisions, editors and peer reviewers provide expert opinions and valuable feedback, thereby safeguarding the integrity of the journal and the scientific process.
Publishing
;
Codes of Ethics
;
Feedback
4.A prototype 3D printed suction port adapter for a wireless otoendoscope
Ma. Cristina Z. Garcia ; Jay Pee M. Amable
Philippine Journal of Otolaryngology Head and Neck Surgery 2024;39(1):44-48
Background and Objective:
To design and fabricate a suction port adapter to use various sizes of suction cannulas
with a wireless otoendoscope enabling ear cleaning under endoscopic guidance demonstrated using an ear examination simulator.
Methods:
Design: Instrument Innovation. Setting: Tertiary Private Training Hospital. Patient: Ear Examination Simulator.
Results:
The fabricated suction port adapters were able to hold the wireless otoendoscope and suction cannulas together, allowing simultaneous inspection of the ear canal and suctioning of ear canal debris using the Ear Examination Simulator.
Conclusion
Our prototype 3D-printed suction port adapters for a wireless otoendoscope may improve ear cleaning by enhancing the accuracy of suctioning debris and decreasing duration since they hold the suction cannulas in place under endoscopic guidance. They may aid ENT physicians in easier visualization and simultaneous ear cleaning of patients and improve ear cleaning techniques and times, especially among less experienced physicians, but actual clinical trials are needed to confirm this.
Printing, Three-Dimensional
;
Cerumen
;
Otoscopy
5.Re-evaluation of systematic reviews of acupuncture and moxibustion for children with cerebral palsy.
Xiao-Fei LU ; Ya-Wen TAO ; Fan LIU ; Yu-Qin XU ; Ming-Qiang GONG ; Zhuo-Xin YANG
Chinese Acupuncture & Moxibustion 2023;43(10):1209-1216
OBJECTIVE:
To assess the methodological quality, report quality and evidence quality of the Meta-analysis and systematic reviews of acupuncture and moxibustion for children with cerebral palsy, aiming to provide decision-making basis for clinical treatment.
METHODS:
The systematic reviews and Meta-analysis of acupuncture and moxibustion for children with cerebral palsy were searched in CNKI, Wanfang, VIP, SinoMed, Cochrane Library, PubMed and EMbase. The retrieval time was from the database establishment to June 30th, 2022. AMSTAR 2 (a measurement tool to assess systematic reviews) was used to evaluate the methodological quality, and PRISMA (preferred reporting items for systematic reviews and Meta-analyses) was used to evaluate the report quality, and GRADE was used to evaluate the quality of evidence.
RESULTS:
A total of 14 systematic reviews were included, including 37 primary outcome indexes. According to AMSTAR 2 evaluation results, there were 4 low quality studies, 10 very low quality studies, and low scores on items 2, 4, 7, 10 and 16. PRISMA scores ranged from 15 to 25, and the main reporting problems reflected in structured abstracts, program and registration, retrieval, and funding sources, etc. According to the GRADE classification results, there were 3 high quality evidences, 7 medium quality evidences, 10 low quality evidences and 17 very low quality evidences. The main downgrading factors were limitations, imprecision and publication bias.
CONCLUSION
Acupuncture and moxibustion has a certain effect for cerebral palsy in children, but the quality of methodology, reporting and evidence in the included literature is poor, and the comparison of curative effect between different acupuncture and moxibustion methods is unclear.
Child
;
Humans
;
Acupuncture Therapy/methods*
;
Cerebral Palsy/therapy*
;
Moxibustion/methods*
;
Publication Bias
;
Research Report
;
Systematic Reviews as Topic
;
Meta-Analysis as Topic
6.Acupuncture for in vitro fertilization-embryo transfer: an overview of systematic reviews.
Xiang-Yu HU ; Wen-Cui XIU ; Lan-Jun SHI ; Rui-Min JIAO ; Zi-Yu TIAN ; Xiao-Yi HU ; Tian-Yu MING ; Wei-Juan GANG ; Xiang-Hong JING
Chinese Acupuncture & Moxibustion 2023;43(11):1315-1323
OBJECTIVES:
To evaluate the report quality, methodological quality and evidence quality of the systematic reviews and meta-analyses (SRs/MAs) of acupuncture for in vitro fertilization-embryo transfer (IVF-ET).
METHODS:
The SRs/MAs of acupuncture for IVF-ET were searched electronically from databases of CNKI, Wanfang, VIP, SinoMed, PubMed, Embase, Cochrane Library, from inception of each database to September 27th, 2022. Two reviewers independently screened the literature and extracted the data. Using PRISMA statement, the AMSTAR 2 scale and the GRADE system, the report quality, methodological quality and evidence quality of the included SRs/MAs were assessed.
RESULTS:
A total of 28 SRs/MAs were included, with PRISMA scores ranging from 8.5 points to 27 points. The problems of report quality focused on protocol and registration, retrieval, risk of bias in studies, additional analysis, limitations and funding. The methodological quality of included studies was generally low, reflecting on items 2, 3, 7, 10, 12 and 16. A total of 85 outcome indexes were included in the GRADE system for evidence grade evaluation. Most of the evidences were low or very low in quality. The reasons for the downgrade were related to study limitations, inconsistency, imprecision and publication bias.
CONCLUSIONS
Acupuncture therapy improves the outcomes of IVF-ET, but the methodological quality and evidence quality of related SRs/MAs are low. It is recommended to conduct more high-quality studies in the future to provide more reliable evidences.
Acupuncture Therapy/methods*
;
Databases, Factual
;
Embryo Transfer
;
Fertilization in Vitro
;
Publication Bias
;
Systematic Reviews as Topic
7.Simultaneous implantation and tooth preparation technology guided by 3D-printed guide.
Nan HU ; Chunxu LIU ; Jing GAO ; Chenyang XIE ; Jiayi YU ; Luming JIA ; Haiyang YU
West China Journal of Stomatology 2023;41(4):483-490
Using digital technologies in concurrently performing missing tooth implantation and preparation of remaining teeth is a solution to reduce the number of visits and improve efficiency. This paper proposes a digital process for simultaneously implanting and preparing teeth. It integrates implant surgical guide and 3D-printed tooth preparation guide into a single guide and completes guided implant placement and precise tooth preparation. Based on "repair-oriented" virtual implant planning, the implant surgical guide can improve the efficiency and predictability of implant placement, and its linear accuracy is about 1 mm. The tooth preparation guide precisely guides tooth preparation and restoration space visualization, ensuring the quality of the tooth preparation. The two guides have different design accuracy requirements, and thus their combination improves the overall guiding accuracy requirements. The concurrent application of the two guides minimizes the clinical operation time, number of visits, and economic burden of patients.
Humans
;
Surgery, Computer-Assisted
;
Dental Implantation, Endosseous
;
Printing, Three-Dimensional
;
Technology
;
Tooth Preparation
;
Computer-Aided Design
;
Dental Implants
;
Imaging, Three-Dimensional
;
Cone-Beam Computed Tomography
8.From "Empirical Surgery" to "Precision Surgery": establishment and clinical application of precision orthognathic surgery system.
Xudong WANG ; Hongpu WEI ; Biao LI
West China Journal of Stomatology 2023;41(5):491-501
Orthognathic surgery, which involve osteotomy and repositioning of the maxillomandibular complex, has recently emerged as a crucial method of correcting dentofacial deformities. The optimal placement of the maxillomandibular complex holds utmost significance during orthognathic surgery because it directly affects the surgical outcome. To accurately achieve the ideal position of the maxillomandibular complex, with the rapid advancements in digital surgery and 3D-printing technology, orthognathic surgery has entered an era of "Precision Surgery" from the pervious "Empirical Surgery." This article provides comprehensive insights into our extensive research and exploration of the treatment modality known as "precision orthognathic surgery" over the years. We also present the technical system and application in"Ortho+X" treatment modality to offer valuable references and assistance to our colleagues in the field.
Orthognathic Surgery
;
Orthognathic Surgical Procedures
;
Printing, Three-Dimensional
;
Surgery, Computer-Assisted
9.4D bioprinting technology and its application in cardiovascular tissue engineering.
Yuxiang HUANG ; Qi LI ; Wu YE ; Ziming HUANG ; Hanxiao QIN ; Ming ZHAO ; Ming LIU
Chinese Journal of Biotechnology 2023;39(10):4046-4056
3D bioprinting technology is a rapidly developing technique that employs bioinks containing biological materials and living cells to construct biomedical products. However, 3D-printed tissues are static, while human tissues are in real-time dynamic states that can change in morphology and performance. To improve the compatibility between in vitro and in vivo environments, an in vitro tissue engineering technique that simulates this dynamic process is required. The concept of 4D printing, which combines "3D printing + time" provides a new approach to achieving this complex technique. 4D printing involves applying one or more smart materials that respond to stimuli, enabling them to change their shape, performance, and function under the corresponding stimulus to meet various needs. This article focuses on the latest research progress and potential application areas of 4D printing technology in the cardiovascular system, providing a theoretical and practical reference for the development of this technology.
Humans
;
Tissue Engineering/methods*
;
Bioprinting/methods*
;
Printing, Three-Dimensional
;
Cardiovascular System
;
Tissue Scaffolds
10.Model test study on treatment of Pruzansky type ⅡB and Ⅲ hemifacial microsomia with artificial condyle-mandibular distractor complex.
Ruilin ZHAO ; Xi FU ; Jia QIAO ; Yu HE ; Shixing XU ; Ying CHEN ; Bing YU ; Jianfeng LIU ; Feng NIU
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(10):1270-1275
OBJECTIVE:
To preliminarily verify the effectiveness of self-designed artificial condyle-mandibular distraction (AC-MD) complex in the treatment of Pruzansky type ⅡB and Ⅲ hemifacial microsomia (HFM) through model test.
METHODS:
Five children with Pruzansky type ⅡB and Ⅲ HFM who were treated with mandibular distraction osteogenesis (MDO) between December 2016 and December 2021 were selected as the subjects. There were 3 boys and 2 girls wih an average age of 8.4 years (range, 6-10 years). Virtual surgery and model test of AC-MD complex were performed according to preoperative skull CT of children. The model was obtained by three-dimensional (3D) printing according to the children's CT data at a ratio of 1∶1. The occlusal guide plate was designed and 3D printed according to the children's toothpaste model. The results of the model test and the virtual surgery were matched in three dimensions to calculate the error of the residual condyle on the affected side, and the model test was matched with the actual skull CT after MDO to measure and compare the inclination rotation of the mandible, the distance between the condylar of the healthy side and the residual condyle of the affected side, and the lengthening length of the mandible.
RESULTS:
The error of residual condyle was (1.07±0.78) mm. The inclination rotation of the mandible, the distance between the condylar of the healthy side and the residual condyle of the affected side, and the lengthening length of the mandible after 3D printing model test were significantly larger than those after MDO ( P<0.05).
CONCLUSION
In the model test, the implantation of AC-MD complex can immediately rotate the mandible to the horizontal position and improve facial symmetry, and the residual condyle segment can be guided close to the articular fossa or the preset pseudoarticular position of the skull base after operation.
Male
;
Child
;
Female
;
Humans
;
Goldenhar Syndrome/surgery*
;
Mandible/surgery*
;
Osteogenesis, Distraction/methods*
;
Printing, Three-Dimensional
;
Facial Asymmetry/surgery*


Result Analysis
Print