1.Implant-assisted removable partial denture using freely removable abutment in a fully edentulous patient: A case report
You Kyoung OH ; Chang Mo JEONG ; Mi Jung YUN ; So Hyoun LEE ; Hyeon Jong LEE ; Jung Bo HUH
The Journal of Korean Academy of Prosthodontics 2020;58(1):58-66
Implant-Assisted Removable Partial Dentures (IARPDs) treatment is being performed in a fully edentulous patient using implant surveyed prosthesis as an abutment. Implant-supported prosthesis as an abutment of IARPDs is classified into screw-retained and cement-retained type according to the retention type, and each has advantages and disadvantages. The EZ crown system (Samwon DMP, Yangsan, Korea) has a cylinder combined with abutment, and the nickel-titanium spring in this cylinder provides a constant force on the zirconia ball to obtain retention in EZ crown system. In this patient, the natural abutment teeth of the mandibular overdenture was hopeless. We planned implant assisted removable partial denture using anterior implant surveyed prosthesis considering functional and esthetical rehabilitation, cost and patient's needs. When fabricating IARPDs using implant as abutment, we could compensate for the shortcomings of existing implant-supported prosthesis retention type and made the design of removable partial denture easy due to using EZ crown system.
Crowns
;
Denture, Overlay
;
Denture, Partial, Removable
;
Gyeongsangnam-do
;
Humans
;
Prostheses and Implants
;
Prosthesis Retention
;
Rehabilitation
;
Tooth
2.Fundamentals of prosthetic urology.
Asian Journal of Andrology 2020;22(1):20-27
The field of prosthetic urology demonstrates the striking impact that simple devices can have on quality of life. Penile prosthesis and artificial urinary sphincter implantation are the cornerstone procedures on which this specialty focuses. Modern research largely concentrates on decreasing the rates of complication and infection, as the current devices offer superior rates of satisfaction when revision is not necessary. These techniques are also able to salvage sexual function and continence in more difficult patient populations including female-to-male transgender individuals, those with ischemic priapism, and those with erectile dysfunction and incontinence secondary to prostatectomy. This review summarizes modern techniques, outcomes, and complications in the field of prosthetic urology.
Erectile Dysfunction/surgery*
;
Humans
;
Male
;
Penile Implantation/methods*
;
Penile Prosthesis
;
Postoperative Complications/epidemiology*
;
Prostatectomy/adverse effects*
;
Prosthesis Failure
;
Prosthesis Implantation/methods*
;
Prosthesis-Related Infections/epidemiology*
;
Surgical Wound Infection/epidemiology*
;
Urethra/injuries*
;
Urinary Incontinence, Stress/surgery*
;
Urinary Retention/epidemiology*
;
Urinary Sphincter, Artificial
;
Urology
3.Evaluation of the clinical efficacy of implant-supported overdenture with edentulous mandible in elderly patients.
West China Journal of Stomatology 2019;37(4):428-432
The aging society of the global population has led to an increase in the number of patients with edentulous jaw, a common multiple disease. Given the developments in implant techniques, the method of implant denture has received a positive and good response in terms of the quality of life and psychological well-being of patients. Implant-supported overdenture in mandible has two main advantages. 1) It has better retention and chewing efficiency than those of mandibular conventional denture. The required implant site of implant-supported overdenture is less than that of fixed implant-supported denture and can repair more defect tissues to help restore beauty and pronunciation. The price of the former is more acceptable than that of the latter. Therefore, this article aimed to systemically analyze and further discuss the clinical effect of implant-supported overdenture in elderly patients; combine existing related studies on the selection of number, site, and upper restoration of implants; and illustrate the advantages of removable implant-supported protheses in the repair of toothless mandible.
Aged
;
Dental Implants
;
Dental Prosthesis, Implant-Supported
;
Denture Retention
;
Denture, Overlay
;
Humans
;
Jaw, Edentulous
;
Mandible
;
Patient Satisfaction
;
Quality of Life
;
Treatment Outcome
4.Advancements in craniofacial prosthesis fabrication: A narrative review of holistic treatment
Hossein E JAZAYERI ; Steve KANG ; Radi M MASRI ; Lauren KUHN ; Farahnaz FAHIMIPOUR ; Rabecca VANEVENHOVEN ; Geoffrey THOMPSON ; Maryam GHEISARIFAR ; Mohammadreza TAHRIRI ; Lobat TAYEBI
The Journal of Advanced Prosthodontics 2018;10(6):430-439
The treatment of craniofacial anomalies has been challenging as a result of technological shortcomings that could not provide a consistent protocol to perfectly restore patient-specific anatomy. In the past, wax-up and impression-based maneuvers were implemented to achieve this clinical end. However, with the advent of computer-aided design and computer-aided manufacturing (CAD/CAM) technology, a rapid and cost-effective workflow in prosthetic rehabilitation has taken the place of the outdated procedures. Because the use of implants is so profound in different facets of restorative dentistry, their placement for craniofacial prosthesis retention has also been widely popular and advantageous in a variety of clinical settings. This review aims to effectively describe the well-rounded and interdisciplinary practice of craniofacial prosthesis fabrication and retention by outlining fabrication, osseointegrated implant placement for prosthesis retention, a myriad of clinical examples in the craniofacial complex, and a glimpse of the future of bioengineering principles to restore bioactivity and physiology to the previously defected tissue.
Bioengineering
;
Computer-Aided Design
;
Dentistry
;
Physiology
;
Prostheses and Implants
;
Prosthesis Retention
;
Rehabilitation
5.Hand Functions of Myoelectric and 3D-Printed Pressure-Sensored Prosthetics: A Comparative Study.
Kyu Ho LEE ; Hobeom BIN ; KeunBae KIM ; So Young AHN ; Bong Ok KIM ; Soo Kyung BOK
Annals of Rehabilitation Medicine 2017;41(5):875-880
The loss of an upper limb significantly limits the functional activities of daily living. A huge emphasis is placed on the manipulation, shape, weight, and comfort of a prosthesis, to enable its use as an inherent body part. Even with technological advances, customized upper-extremity myoelectric prosthesis remain heavy and expensive. The high cost of upper-extremity prosthesis is an especially steep economic barrier for patients. Three-dimensional (3D) printing is a promising avenue for reducing the cost of prosthesis. We applied 3D-printed pressure-sensored prosthetics to a traumatic transradial amputee, and compared the hand functions with a customized myoelectric prosthesis. The 3D-printed pressure-sensored prosthetics showed low grip strength and decreased dexterity compared to the conventional myoelectric prosthesis. Although there were a few limitations, the fabrication of prosthesis with 3D printing technology can overcome previous problems such as high production cost, long fabrication period and heavy weight.
Activities of Daily Living
;
Amputation
;
Amputees
;
Hand Strength
;
Hand*
;
Humans
;
Printing, Three-Dimensional
;
Prostheses and Implants
;
Prosthesis Fitting
;
Upper Extremity
6.Surgical Outcomes of Porcine Acellular Dermis Graft in Anophthalmic Socket: Comparison with Oral Mucosa Graft.
Livia TEO ; Young Jun WOO ; Dong Kyu KIM ; Chang Yeom KIM ; Jin Sook YOON
Korean Journal of Ophthalmology 2017;31(1):9-15
PURPOSE: We describe our experience with the Permacol graft in anophthalmic socket reconstruction, and compare it to the autologous buccal mucosal graft, emphasizing the postoperative vascularization and contraction of each graft. METHODS: This was a retrospective comparative study. We measured the time necessary for the graft surface to be completely vascularized, as well as the fornix depth of the conjunctival sac in anophthalmic patients. RESULTS: Ten patients underwent Permacol graft reconstruction, with 44 undergoing buccal mucosal graft reconstruction. Seven eyelids (70%) in the Permacol group had a good outcome, with improvement in lower eyelid position and prosthesis retention. Nine out of 10 eyelids (90%) in this group showed complete vascularization of the graft at 2.6 ± 1.9 months postoperatively, while the grafted buccal mucosa was fully vascularized at 1.1 ± 0.3 months postoperatively (p < 0.01). Postoperative fornix depth in the Permacol group was 9.1 ± 2.2 mm, compared to 14.9 ± 4.5 mm in the buccal mucosal graft group (p < 0.01). Mean increases in fornix depth were 33.1% and 67.9% of the mean vertical length of the implanted graft. CONCLUSIONS: The Permacol graft can be useful as spacer graft material in anophthalmic socket patients. It takes longer to vascularize, and undergoes greater graft shrinkage with time, compared to the buccal mucosal graft.
Acellular Dermis*
;
Anophthalmos
;
Eyelids
;
Humans
;
Lacrimal Apparatus
;
Mouth Mucosa*
;
Prosthesis Retention
;
Retrospective Studies
;
Transplants*
7.Removable Partial Denture Using Anterior Implant-Supported Fixed Prostheses for Edentulous Patients: A Case Report
You Jin LEE ; Eun Bin BAE ; Chang Mo JEONG ; Jin Ju LEE ; Ji Young KIM ; Jung Bo HUH
Journal of Korean Dental Science 2017;10(2):87-95
This case study was to report the possible increase in the denture retention and psychological relief using the implant-supported fixed prostheses in a completely edentulous patient. The implants were placed in the anterior portion of the mandible in a patient who had completely edentulous state following the extraction of residual abutment teeth, and consequently a distal extension removable partial denture was fabricated. The patient's adaptation and satisfaction to the new prosthesis was monitored and confirmed in terms of masticatory function and esthetics, by restoring the oral condition similar to initial status before the residual teeth extraction. After 6 months, radiographic examination confirmed that both the abutment teeth and the implants were stable and well maintained. Considering the relatively short clinical follow-up period, however, continuous long-term monitoring was required.
Dental Prosthesis, Implant-Supported
;
Denture Retention
;
Denture, Partial, Removable
;
Esthetics
;
Follow-Up Studies
;
Humans
;
Mandible
;
Mandibular Prosthesis
;
Prostheses and Implants
;
Tooth
8.Delayed prosthesis fitting in an elderly with congenital lower limb deficiency: A case report
Journal of the Philippine Medical Association 2017;96(1):62-70
Congenital anomalies, including limb deficiency, affect approximately 7.9 million newborns annually. Fitting the prosthesis at an early stage will aid the patient to achieve two-legged standing, to develop reciprocating gait and to attain an optimal body image.
A 64-year-old female diagnosed with congenital limb deficiency, right, using a customized shoe was admitted for prosthetic management at the study hospital.
Patient underwent inpatient prosthetic training with physical and occupational therapy.
Psychological evaluation was done to assess for depression and anxiety and to determine the patient's response to the prosthesis. The Prosthesis Evaluation Questionnaire (PEQ), an instrument to measure prosthesis-related quality of life and functional outcome, was administered. 3D motion analysis was done to observe the temporospatial parameters of the patient's gait with and without the prosthesis.
The patient had generally positive response towards her prosthesis based on PEQ administered 1 month after the provision of prosthesis. Psychological evaluation showed that the patient had improved general outlook after the provision of the prosthesis. Patient had slower self-selected walking speed compared to transtibial amputee using prosthesis.
Early fitting and fabrication of prosthesis is recommended for the patient with congenital amputation. Studies showed that delayed fitting of prosthesis may decrease acceptance and use of prosthesis. However, provision of properly fitted prosthesis may still improve the quality of life of the patient who is already functionally independent without it.
More than increase in physical activity, participation in leisurely activities that promote social interaction motivates elderly patients to use their prosthesis more often.
Lower Extremity
;
Prosthesis Fitting
9.Stability of the prosthetic screws of three types of craniofacial prostheses retention systems.
Antonio Gabriel LANATA-FLORES ; Eder Alberto SIGUA-RODRIGUEZ ; Douglas Rangel GOULART ; Veber Luiz BOMFIM-AZEVEDO ; Sergio OLATE ; José Ricardo DE ALBERGARIA-BARBOSA
Journal of the Korean Association of Oral and Maxillofacial Surgeons 2016;42(6):352-357
OBJECTIVES: This study aimed to evaluate the stability of prosthetic screws from three types of craniofacial prostheses retention systems (bar-clip, ball/O-ring, and magnet) when submitted to mechanical cycling. MATERIALS AND METHODS: Twelve models of acrylic resin were used with implants placed 20 mm from each other and separated into three groups: (1) bar-clip (Sistema INP, São Paulo, Brazil), (2) ball/O-ring (Sistema INP), and (3) magnet (Metalmag, São Paulo, Brazil), with four samples in each group. Each sample underwent a mechanical cycling removal and insertion test (f=0.5 Hz) to determine the torque and the detorque values of the retention screws. A servo-hydraulic MTS machine (810-Flextest 40; MTS Systems, Eden Prairie, MN, USA) was used to perform the cycling with 2.5 mm and a displacement of 10 mm/s. The screws of the retention systems received an initial torque of 30 Ncm and the torque values required for loosening the screw values were obtained in three cycles (1,080, 2,160, and 3,240). The screws were retorqued to 30 Ncm before each new cycle. RESULTS: The sample was composed of 24 screws grouped as follows: bar-clip (n=8), ball/O-ring (n=8), and magnet (n=8). There were significant differences between the groups, with greater detorque values observed in the ball/O-ring group when compared to the bar-clip and magnet groups for the first cycle. However, the detorque value was greater in the bar-clip group for the second cycle. CONCLUSION: The results of this study indicate that all prosthetic screws will loosen slightly after an initial tightening torque, also the bar-clip retention system demonstrated greater loosening of the screws when compared with ball/O-ring and magnet retention systems.
Grassland
;
Maxillofacial Prosthesis
;
Prostheses and Implants*
;
Prosthesis Failure
;
Prosthesis Retention
;
Torque
10.Acinetobacter Prosthetic Joint Infection Treated with Debridement and High-Dose Tigecycline.
Andrea VILA ; Hugo PAGELLA ; Claudio AMADIO ; Alejandro LEIVA
Infection and Chemotherapy 2016;48(4):324-329
Prosthesis retention is not recommended for multidrug-resistant Acinetobacter prosthetic joint infection due to its high failure rate. Nevertheless, replacing the prosthesis implies high morbidity and prolonged hospitalization. Although tigecycline is not approved for the treatment of prosthetic joint infection due to multidrug resistant Acinetobacter baumannii, its appropriate use may preclude prosthesis exchange. Since the area under the curve divided by the minimum inhibitory concentration is the best pharmacodynamic predictor of its efficacy, we used tigecycline at high dose, in order to optimize its efficacy and achieve implant retention in 3 patients who refused prosthesis exchange. All patients with prosthetic joint infections treated at our Institution are prospectively registered in a database. Three patients with early prosthetic joint infection of total hip arthroplasty due to multidrug resistant A. baumannii were treated with debridement, antibiotics and implant retention, using a high maintenance dose of tigecycline (100 mg every 12 hours). The cases were retrospectively reviewed. All patients signed informed consent for receiving off-label use of tigecycline. Tigecycline was well tolerated, allowing its administration at high maintenance dose for a median of 40 days (range 30–60). Two patients were then switched to minocycline at standard doses for a median of 3.3 months in order to complete treatment. Currently, none of the patients showed relapse. Increasing the dose of tigecycline could be considered as a means to better attain pharmacodynamic targets in patients with severe or difficult-to-treat infections. Tigecycline at high maintenance dose might be useful when retention of the implant is attempted for treatment for prosthetic joint infections due to multidrug resistant Acinetobacter. Although this approach might be promising, off-label use of tigecycline should be interpreted cautiously until prospective data are available. Tigecycline is probably under-dosed for the treatment of implant and biofilm associated infections.
Acinetobacter baumannii
;
Acinetobacter*
;
Anti-Bacterial Agents
;
Arthroplasty, Replacement, Hip
;
Biofilms
;
Debridement*
;
Hospitalization
;
Humans
;
Informed Consent
;
Joints*
;
Microbial Sensitivity Tests
;
Minocycline
;
Off-Label Use
;
Prospective Studies
;
Prostheses and Implants
;
Prosthesis Retention
;
Recurrence
;
Retrospective Studies


Result Analysis
Print
Save
E-mail