1.Rehabilitation management of a pediatric patient with modified van nes prosthesis after type B-IIIA hip rotationplasty: A case report
Seann Bregendale L. Silangan ; Joycie Eulah H. Abiera ; L. Czar Gaston
Acta Medica Philippina 2024;58(20):107-112
Van Nes rotationplasty has gained popularity as a surgical treatment for malignant bone tumors without resorting to amputation. However, the nature of the surgery poses unique challenges in the rehabilitation management in order to optimize safety and functional mobility. We describe a case of a 6-year-old female with Ewing’s sarcoma of the right femur who underwent Van Nes Type BIIIA rotationplasty. This procedure involved a complete femoral resection, with the tibia and the foot rotated by 180 degrees and the lateral tibial plateau placed into the acetabulum that is expected to remodel to form a neo-hip joint. The patient was referred to rehabilitation medicine and was eventually admitted due to impairment in mobility secondary to the surgery. The goal was to achieve K-1 level of function. This case demonstrates that the rehabilitation management of a child with Type B-IIIA rotationplasty using a modified Van Nes prosthesis requires a comprehensive multidisciplinary approach.
Human ; Female ; Child: 6-12 Yrs Old ; Prosthesis ; Prostheses And Implants ; Rehabilitation
3.Observation of the Curative Effect of the Dexamethasone Vitreous Cavity Implant for the Treatment of Irvine-Gass Syndrome.
Yu MAO ; Li Qin GAO ; Li Yun JIA ; Si Meng HOU ; Yuan Yuan XIAO ; Xi Wen JI ; Shuang WANG
Biomedical and Environmental Sciences 2023;36(8):725-731
OBJECTIVE:
To investigate the clinical efficacy of dexamethasone vitreous cavity implants (Ozurdex) for the treatment of macular edema (Irvine-Gass Syndrome) after cataract surgery.
METHOD:
Eight patients (eight eyes) with Irvine-Gass syndrome were enrolled for vitreous injections with Ozurdex. The patients included six men (six eyes) and two women (two eyes) with a mean age of 67.12 ± 11.92 years. Changes in the patients best-corrected visual acuity (BCVA), central macular thickness (CMT), and intraocular pressure were compared before and after treatment.
RESULT:
The mean visual acuity BCVA of the patients was 0.81 ± 0.26 before implantation, which improved to 0.20 ± 0.12, 0.13 ± 0.09, and 0.15 ± 0.13 at 2 weeks, 1 month, and 3 months after implantation, respectively ( P < 0.001). The patient's mean CMT before implantation was 703.00 ± 148.88 μm, and it reduced to 258.87 ± 37.40 μm, 236.25 ± 28.74 μm, and 278.00 ± 76.82 μm at 2 weeks, 1 month, and 3 months after implantation, respectively ( P < 0.001).
CONCLUSION
The dexamethasone vitreous cavity implant (Ozurdex) is a safe and effective treatment, which can effectively improve patient's visual acuity and reduce macular edema associated with cataract surgery.
Male
;
Humans
;
Female
;
Middle Aged
;
Aged
;
Macular Edema/etiology*
;
Dexamethasone/therapeutic use*
;
Intraocular Pressure
;
Prostheses and Implants
;
Cataract
4.Long-term effectiveness of uncemented allograft-prosthesis composite for reconstruction of bone defects after proximal femur tumor resection.
Yang WANG ; Minxun LU ; Yuqi ZHANG ; Xuanhong HE ; Zhuangzhuang LI ; Taojun GONG ; Yitian WANG ; Yong ZHOU ; Yi LUO ; Fan TANG ; Wenli ZHANG ; Hong DUAN ; Chongqi TU ; Li MIN
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(10):1190-1197
OBJECTIVE:
To investigate the long-term effectiveness of uncemented allograft-prosthesis composite (APC) for reconstruction of bone defects after proximal femur tumor resection.
METHODS:
Between June 2007 and March 2014, 21 patients who underwent uncemented APC reconstruction of proximal femur after tumor resection were retrospectively evaluated. There were 9 males and 12 females with an average age of 33.2 years (range, 19-54 years). There were 9 cases of giant cell tumor of bone, 5 cases of osteosarcoma, 4 cases of osteoblastic osteosarcoma, 2 cases of chondrosarcoma, and 1 case of undifferentiated pleomorphic sarcoma. Thirteen cases of benign bone tumors were all classified as stage 3 by Enneking staging; and 8 cases of malignant bone tumors were classified as grade ⅡB in 7 cases and grade ⅡA in 1 case according to the American Joint Committee on Cancer (AJCC) staging system. Among them, 7 patients underwent reoperation after recurrence, and the rest were primary operations; 8 patients presented with pathological fractures. The preoperative Harris hip score (HHS) and American Musculoskeletal Tumor Society (MSTS) score was 40 (30, 49) and 9.1±3.5, respectively. The length of osteotomy was 80-154 mm, with an average of 110 mm. At 1 year after operation and last follow-up, HHS and MSTS scores were utilized to evaluate the function of hip joint; the gluteus medius strength score was used to evaluation of the hip abduction function. Image examinations were taken at 1, 3, 6, 9, and 12 months after operation and every year thereafter to assess the union of allograft-host bone interfaces. Intra- and post-operative complications were also recorded.
RESULTS:
All patients were followed up 84-163 months (mean, 123.5 months). At 1 year after operation and last follow-up, the HHS and MSTS scores significantly improved when compared with the preoperative scores ( P<0.05). However, there was no significant difference in the HHS score, MSTS score, and gluteus medius strength score between the two time points after operation ( P>0.05). Image examination showed that all allograft-host bone interfaces achieved union after 5-10 months (mean, 7.6 months). At last follow-up, all patients had bone resorption, including 11 severe cases, 4 moderate cases, and 6 mild cases; the bone resorption sites included Gruen 1, 2, and 7 regions. Complications included 10 fractures and 1 prosthetic fracture. Local recurrence occurred in 3 patients and pulmonary metastasis in 3 patients.
CONCLUSION
Uncemented APC is a reliable method for the reconstruction of bone defects after proximal femur tumor resection. It has the good long-term effectiveness and possesses obvious advantages in the union at the bone-bone surface.
Adult
;
Female
;
Humans
;
Male
;
Allografts/pathology*
;
Bone Neoplasms/surgery*
;
Bone Resorption/pathology*
;
Bone Transplantation/methods*
;
Femur/surgery*
;
Osteosarcoma/pathology*
;
Prostheses and Implants
;
Retrospective Studies
;
Treatment Outcome
;
Young Adult
;
Middle Aged
5.Progress in antibacterial/osteogenesis dual-functional surface modification strategy of titanium-based implants.
Peng LIU ; Bo FAN ; Lei ZOU ; Lijun LÜ ; Qiuming GAO
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(10):1300-1313
OBJECTIVE:
To review antibacterial/osteogenesis dual-functional surface modification strategy of titanium-based implants, so as to provide reference for subsequent research.
METHODS:
The related research literature on antibacterial/osteogenesis dual-functional surface modification strategy of titanium-based implants in recent years was reviewed, and the research progress was summarized based on different kinds of antibacterial substances and osteogenic active substances.
RESULTS:
At present, the antibacterial/osteogenesis dual-functional surface modification strategy of titanium-based implants includes: ① Combined coating strategy of antibiotics and osteogenic active substances. It is characterized in that antibiotics can be directly released around titanium-based implants, which can improve the bioavailability of drugs and reduce systemic toxicity. ② Combined coating strategy of antimicrobial peptides and osteogenic active substances. The antibacterial peptides have a wide antibacterial spectrum, and bacteria are not easy to produce drug resistance to them. ③ Combined coating strategy of inorganic antibacterial agent and osteogenic active substances. Metal ions or metal nanoparticles antibacterial agents have broad-spectrum antibacterial properties and various antibacterial mechanisms, but their high-dose application usually has cytotoxicity, so they are often combined with substances that osteogenic activity to reduce or eliminate cytotoxicity. In addition, inorganic coatings such as silicon nitride, calcium silicate, and graphene also have good antibacterial and osteogenic properties. ④ Combined coating strategy of metal organic frameworks/osteogenic active substances. The high specific surface area and porosity of metal organic frameworks can effectively package and transport antibacterial substances and bioactive molecules. ⑤ Combined coating strategy of organic substances/osteogenic active substancecs. Quaternary ammonium compounds, polyethylene glycol, N-haloamine, and other organic compounds have good antibacterial properties, and are often combined with hydroxyapatite and other substances that osteogenic activity.
CONCLUSION
The factors that affect the antibacterial and osteogenesis properties of titanium-based implants mainly include the structure and types of antibacterial substances, the structure and types of osteogenesis substances, and the coating process. At present, there is a lack of clinical verification of various strategies for antibacterial/osteogenesis dual-functional surface modification of titanium-based implants. The optimal combination, ratio, dose-effect mechanism, and corresponding coating preparation process of antibacterial substances and bone-active substances are needed to be constantly studied and improved.
Anti-Bacterial Agents/pharmacology*
;
Coated Materials, Biocompatible/chemistry*
;
Metal-Organic Frameworks/pharmacology*
;
Osteogenesis
;
Surface Properties
;
Titanium/pharmacology*
;
Prostheses and Implants
6.Discussion and Concern on Animal Study for Orthopaedic Implantable Devices.
Jiazhen ZHANG ; Bao ZHAI ; Ruhan A ; Le JIN ; Yajuan GUO ; Xinli SHI
Chinese Journal of Medical Instrumentation 2023;47(5):550-556
In recent years, new orthopaedic implantable devices continue to emerge, which require higher requirements for technical evaluation. Animal study is an important part of the research and development process for the new orthopedic implantable devices, which provides relevant evidence for product design and stereotyping. By introducing the purpose of animal study, and the application of 3R principle (replacement, reduction, refinement) in this field, we summarize the concern on the animal study, in order to provide reference for the development and research of new orthopedic implantable devices and biomaterials. At the same time, the application of evidence-based research methods such as systematic review in the field is introduced, which provides new tools and approaches for the technical review and regulatory science.
Animals
;
Orthopedics
;
Biocompatible Materials
;
Prostheses and Implants
;
Research Design
8.One-stage revision using intra-articular vancomycin infusion effectively treats chronic prosthetic joint infection caused by Enterococcal.
Yi Cheng LI ; Xiao Gang ZHANG ; Xiao Bin GUO ; Wuhuzi WULAMU ; Nuerailijiang YUSHAN ; Li CAO
Chinese Journal of Surgery 2023;61(2):120-128
Objective: To investigate the clinical effects of one-stage revision combined with intra-articular infusion of vancomycin in the treatment of chronic prosthetic joint infection (PJI) caused by Enterococcal. Methods: From May 2013 to June 2020,the clinical data of 9 patients (2 males and 7 females) with chronic Enterococcal PJI treated with one-stage revision using intra-articular infusion of vancomycin at Department of Orthopaedics,First Affiliated Hospital of Xinjiang Medical University were retrospectively analyzed,including 8 hips and 1 knee.A total of 9 patients with age of (63.9±11.7)years (range:43 to 76 years) were included, and the body mass index was (23.6±4.3)kg/m2 (range:18 to 30 kg/m2).There were 6 cases with antibiotic history and 5 cases with sinus tract.The joint fluid,infected tissue around the prosthesis and ultrasonic shock fluid of the prosthesis were collected during operation for microbial culture identification and drug sensitivity test.After thorough debridement of the infected site and removal of the infected prosthesis,a new prosthesis was implanted,then the drainage tube in the operation area was placed.After surgery,vancomycin(1.0 g,q12 h) was combined with intra-articular vancomycin(0.5 g,qd) in monomicrobial PJI,and vancomycin(1.0 g,q12 h) was combined with intra-articular vancomycin (0.5 g,qd) and imipenem/meropenem (0.5 g,qd),and the interval between the two drugs was 12 hours in polymicrobial PJI.Hip and knee functions were evaluated by Harris Hip Score or Knee Society Score(KSS),respectively.The comparison of hip function scores before and after operation was performed by paired t-test. Results: All patients were followed up for (60±39)months(range:24 to 110 months).Two cases were infected with Enterococcus faecium and 7 cases were infected with Enterococcus faecalis.There were 7 cases of monomicrobial infection and 2 cases of polymicrobial infection.Erythromycin(5/9),tetracycline(4/9),ciprofloxacin and β-lactam antibiotics(3/9) were the top three antibiotics in Enterococci resistance rate.The sensitive antibiotics for Enterococcal were vancomycin,linezolid and tigecycline.The average duration of intravenous antibiotics was (14±1)days (range:13 to 17 days),and the average duration of antibiotics in articular cavity was (15±2)days(range:11 to 20 days).Mean duration of oral antibiotic use after discharge was (2±1)months(range:1 to 3 months).One case of polymicrobial PJI treatment failed,with a failure rate of 1/9.At last follow-up,the Harris score of patients with hip PJI increased from (43±6)points to (84±6)points(t=-11.899, P<0.01). KSS score of knee function was improved from 33 point pre-operatively to 85 point post-operatively;overall function score was improved from 35 point pre-operatively to 80 point post-operatively.During the treatment,no formation of sinus tract of the hip joint caused by a catheter,skin necrosis at the knee puncture site or leakage of joint fluid;no complications such as deep vein thrombosis and pulmonary embolism occurred. Conclusions: One-stage revision combined with intra-articular infusion of vancomycin can achieve acceptable infection control rate and joint function in patients with chronic Enterococcus PJI.However,the treatment of polymicrobial PJI still needs to be further verified.
Female
;
Male
;
Humans
;
Vancomycin/therapeutic use*
;
Retrospective Studies
;
Anti-Bacterial Agents/therapeutic use*
;
Enterococcus
;
Prostheses and Implants
;
Inflammation
9.Research status and development of biodegradable zinc alloy as orthopedics implant.
Tianwei ZHANG ; Yuchen LIU ; Weidan WANG ; Dewei ZHAO
Journal of Biomedical Engineering 2023;40(3):589-594
Znic (Zn) alloys with good cytocompatibility and suitable degradation rate have been a kind of biodegradable metal with great potential for clinical applications. This paper summarizes the biological role of degradable Zn alloy as bone implant materials, discusses the mechanical properties of different Zn alloys and their advantages and disadvantages as bone implant materials, and analyzes the influence of different processing strategies (such as alloying and additive manufacturing) on the mechanical properties of Zn alloys. This paper provides systematic design approaches for biodegradable Zn alloys as bone implant materials in terms of the material selection, product processing, structural topology optimization, and assesses their application prospects with a view to better serve the clinic.
Orthopedics
;
Zinc
;
Alloys
;
Dental Materials
;
Prostheses and Implants
10.Research and Implementation of 433 MHz-based Wireless Implantable Pacing System.
Chinese Journal of Medical Instrumentation 2022;46(1):16-20
In order to solve the problem of communication interference and communication distance caused by the rapid pacing system when establishing the rapid atrial fibrillation model, a low-power implantable pacing system based on 433 MHz communication frequency to form a star network is designed. The system includes an implantable pacemaker, a programmer head, and programmer software. The pacemaker is composed of a wireless communication module, a pacing module, an ECG monitoring module, and a power management module. The programmer head acts as an intermediate node in the star network and is controlled by PC programmer software to program each pacemaker. This article introduces the hardware design and software flow of each part of the system, and describes the results of in vivo simulation and in vivo animal models of the system. The results show that the designed system and application method are effective and feasible for the rapid atrial pacing atrial fibrillation model. 433 MHz wireless communication, implantable, pacemaker system, low-power, ECG monitoring.
Animals
;
Atrial Fibrillation/therapy*
;
Electrocardiography
;
Equipment Design
;
Pacemaker, Artificial
;
Prostheses and Implants
;
Wireless Technology


Result Analysis
Print
Save
E-mail