1.Effects of Platycodonis Radix-Curcumae Rhizoma on oral nanoparticle uptake and in vitro inhibition against breast cancer metastasis.
Jiang-Pei SHI ; Rong-Guang ZHANG ; Xiao-Yan GU ; Ying-Wei SUN ; Nian-Ping FENG ; Ying LIU
China Journal of Chinese Materia Medica 2023;48(9):2419-2425
		                        		
		                        			
		                        			This study combined the herbal pair Platycodonis Radix-Curcumae Rhizoma(PR-CR) possessing an inhibitory effect on tumor cell proliferation and metastasis with the active component of traditional Chinese medicine(TCM) silibinin-loaded nanoparticles(NPs) with a regulatory effect on tumor microenvironment based on the joint effect on tumor cells and tumor microenvironment to inhi-bit cell metastasis. The effects of PR-CR on the cellular uptake of NPs and in vitro inhibition against breast cancer proliferation and metastasis were investigated to provide an experimental basis for improving nanoparticle absorption and enhancing therapeutic effects. Silibinin-loaded lipid-polymer nanoparticles(LPNs) were prepared by the nanoprecipitation method and characterized by transmission electron microscopy. The NPs were spherical or quasi-spherical in shape with obvious core-shell structure. The mean particle size was 107.4 nm, Zeta potential was-27.53 mV. The cellular uptake assay was performed by in vitro Caco-2/E12 coculture cell model and confocal laser scanning microscopy(CLSM), and the results indicated that PR-CR could promote the uptake of NPs. Further, in situ intestinal absorption assay by the CLSM vertical scanning approach showed that PR-CR could promote the absorption of NPs in the enterocytes of mice. The inhibitory effect of NPs on the proliferation and migration of 4T1 cells was analyzed using 4T1 breast cancer cells and co-cultured 4T1/WML2 cells, respectively. The results of the CCK8 assay showed that PR-CR-containing NPs could enhance the inhibition against the proliferation of 4T1 breast cancer cells. The wound healing assay indicated that PR-CR-containing NPs enhanced the inhibition against the migration of 4T1 breast cancer cells. This study enriches the research on oral absorption of TCM NPs and also provides a new idea for utilizing the advantages of TCM to inhibit breast cancer metastasis.
		                        		
		                        		
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Mice
		                        			;
		                        		
		                        			Animals
		                        			;
		                        		
		                        			Female
		                        			;
		                        		
		                        			Silybin/therapeutic use*
		                        			;
		                        		
		                        			Caco-2 Cells
		                        			;
		                        		
		                        			Polymers/chemistry*
		                        			;
		                        		
		                        			Nanoparticles/chemistry*
		                        			;
		                        		
		                        			Cell Line, Tumor
		                        			;
		                        		
		                        			Breast Neoplasms/pathology*
		                        			;
		                        		
		                        			Tumor Microenvironment
		                        			
		                        		
		                        	
2.Five-year outcomes of biodegradable versus second-generation durable polymer drug-eluting stents used in complex percutaneous coronary intervention.
Na XU ; Lin JIANG ; Yi YAO ; Jingjing XU ; Ru LIU ; Huanhuan WANG ; Ying SONG ; Lijian GAO ; Zhan GAO ; Xueyan ZHAO ; Bo XU ; Yaling HAN ; Jinqing YUAN
Chinese Medical Journal 2023;136(3):322-330
		                        		
		                        			BACKGROUND:
		                        			There are few data comparing clinical outcomes of complex percutaneous coronary intervention (CPCI) when using biodegradable polymer drug-eluting stents (BP-DES) or second-generation durable polymer drug-eluting stents (DP-DES). The purpose of this study was to investigate the safety and efficacy of BP-DES and compare that with DP-DES in patients with and without CPCI during a 5-year follow-up.
		                        		
		                        			METHODS:
		                        			Patients who exclusively underwent BP-DES or DP-DES implantation in 2013 at Fuwai Hospital were consecutively enrolled and stratified into two categories based on CPCI presence or absence. CPCI included at least one of the following features: unprotected left main lesion, ≥2 lesions treated, ≥2 stents implanted, total stent length >40 mm, moderate-to-severe calcified lesion, chronic total occlusion, or bifurcated target lesion. The primary endpoint was major adverse cardiac events (MACE) including all-cause death, recurrent myocardial infarction, and total coronary revascularization (target lesion revascularization, target vessel revascularization [TVR], and non-TVR) during the 5-year follow-up. The secondary endpoint was total coronary revascularization.
		                        		
		                        			RESULTS:
		                        			Among the 7712 patients included, 4882 (63.3%) underwent CPCI. Compared with non-CPCI patients, CPCI patients had higher 2- and 5-year incidences of MACE and total coronary revascularization. Following multivariable adjustment including stent type, CPCI was an independent predictor of MACE (adjusted hazard ratio [aHR]: 1.151; 95% confidence interval [CI]: 1.017-1.303, P  = 0.026) and total coronary revascularization (aHR: 1.199; 95% CI: 1.037-1.388, P  = 0.014) at 5 years. The results were consistent at the 2-year endpoints. In patients with CPCI, BP-DES use was associated with significantly higher MACE rates at 5 years (aHR: 1.256; 95% CI: 1.078-1.462, P  = 0.003) and total coronary revascularization (aHR: 1.257; 95% CI: 1.052-1.502, P  = 0.012) compared with that of DP-DES, but there was a similar risk at 2 years. However, BP-DES had comparable safety and efficacy profiles including MACE and total coronary revascularization compared with DP-DES in patients with non-CPCI at 2 and 5 years.
		                        		
		                        			CONCLUSIONS
		                        			Patients underwent CPCI remained at a higher risk of mid- to long-term adverse events regardless of the stent type. The effect of BP-DES compared with DP-DES on outcomes was similar in CPCI and non-CPCI patients at 2 years but had inconsistent effects at the 5-year clinical endpoints.
		                        		
		                        		
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Drug-Eluting Stents/adverse effects*
		                        			;
		                        		
		                        			Myocardial Infarction/complications*
		                        			;
		                        		
		                        			Polymers/therapeutic use*
		                        			;
		                        		
		                        			Treatment Outcome
		                        			;
		                        		
		                        			Coronary Artery Disease/complications*
		                        			;
		                        		
		                        			Percutaneous Coronary Intervention/adverse effects*
		                        			;
		                        		
		                        			Absorbable Implants
		                        			;
		                        		
		                        			Prosthesis Design
		                        			
		                        		
		                        	
3.A novel biodegradable polymer-coated sirolimus-eluting stent: 1-year results of the HELIOS registry.
Bo ZHENG ; Yi LIU ; Ruining ZHANG ; Wangwei YANG ; Fangju SU ; Rutao WANG ; Dapeng CHEN ; Guidong SHEN ; Yumin QIU ; Lianmin WANG ; Chang CHEN ; Zhongwei WU ; Fei LI ; Jiayi LI ; Chengxiang LI ; Chao GAO ; Ling TAO
Chinese Medical Journal 2023;136(15):1848-1854
		                        		
		                        			BACKGROUND:
		                        			The HELIOS stent is a sirolimus-eluting stent with a biodegradable polymer and titanium oxide film as the tie-layer. The study aimed to evaluate the safety and efficacy of HELIOS stent in a real-world setting.
		                        		
		                        			METHODS:
		                        			The HELIOS registry is a prospective, multicenter, cohort study conducted at 38 centers across China between November 2018 and December 2019. A total of 3060 consecutive patients were enrolled after application of minimal inclusion and exclusion criteria. The primary endpoint was target lesion failure (TLF), defined as a composite of cardiac death, non-fatal target vessel myocardial infarction (MI), and clinically indicated target lesion revascularization (TLR) at 1-year follow-up. Kaplan-Meier methods were used to estimate the cumulative incidence of clinical events and construct survival curves.
		                        		
		                        			RESULTS:
		                        			A total of 2998 (98.0%) patients completed the 1-year follow-up. The 1-year incidence of TLF was 3.10% (94/2998, 95% closed interval: 2.54-3.78%). The rates of cardiac death, non-fatal target vessel MI and clinically indicated TLR were 2.33% (70/2998), 0.20% (6/2998), and 0.70% (21/2998), respectively. The rate of stent thrombosis was 0.33% (10/2998). Age ≥60 years, diabetes mellitus, family history of coronary artery disease, acute myocardial infarction at admission, and device success were independent predictors of TLF at 1 year.
		                        		
		                        			CONCLUSION:
		                        			The 1-year incidence rates of TLF and stent thrombosis were 3.10% and 0.33%, respectively, in patients treated with HELIOS stents. Our results provide clinical evidence for interventional cardiologists and policymakers to evaluate HELIOS stent.
		                        		
		                        			CLINICAL TRIAL REGISTRATION
		                        			ClinicalTrials.gov, NCT03916432.
		                        		
		                        		
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Middle Aged
		                        			;
		                        		
		                        			Sirolimus/therapeutic use*
		                        			;
		                        		
		                        			Drug-Eluting Stents/adverse effects*
		                        			;
		                        		
		                        			Prospective Studies
		                        			;
		                        		
		                        			Cohort Studies
		                        			;
		                        		
		                        			Treatment Outcome
		                        			;
		                        		
		                        			Risk Factors
		                        			;
		                        		
		                        			Time Factors
		                        			;
		                        		
		                        			Percutaneous Coronary Intervention/adverse effects*
		                        			;
		                        		
		                        			Cardiovascular Agents/therapeutic use*
		                        			;
		                        		
		                        			Coronary Artery Disease/therapy*
		                        			;
		                        		
		                        			Myocardial Infarction/etiology*
		                        			;
		                        		
		                        			Thrombosis/complications*
		                        			;
		                        		
		                        			Polymers
		                        			;
		                        		
		                        			Registries
		                        			
		                        		
		                        	
4.Five-year clinical outcomes of the second generation biodegradable polymer sirolimus-eluting stent (EXCROSSAL) in treating patients with de novo coronary lesions.
Geng WANG ; Kun NA ; Yi LI ; Quan Min JING ; Xiao Zeng WANG ; Hai Wei LIU ; Bin WANG ; Kai XU ; Ya Ling HAN
Chinese Journal of Cardiology 2021;49(2):121-127
		                        		
		                        			
		                        			Objective: To evaluate the five-year safety and efficacy of the second generation biodegradable polymer sirolimus-eluting stent (EXCROSSAL) in treating patients with de novo coronary artery diseases. Methods: Patients with coronary artery disease (CAD)who were implanted with EXTROSSAL stents in CREDIT Ⅱ and CREDIT Ⅲ study were included. CREDIT Ⅱ was a randomized trial, and CREDIT Ⅲ was a single-arm study. From November 2013 to December 2014, 833 CAD patients with de novo coronary lesions implanted with EXTROSSAL stents were selected from 33 centers in China. The primary outcome was 5-year target lesion failure (TLF), a composite of cardiac death, target vessel myocardial infarction and clinically indicated target lesion revascularization. Secondary endpoints was patient-oriented composite endpoint (PoCE), including all-cause death, all myocardial infarction, or any revascularization within 5 years post stenting and stent thrombosis according to Academic Research Consortium's (ARC) definition. Kaplan Meier method was used to calculate the incidence of TLF and PoCE within 5 years after operation. Univariate Cox regression analysis was used to analyze the impacts of diabetes, small vessel disease (vessel diameter ≤ 2.74 mm), lesion length ≥ 16.7 mm and multivessel disease on the incidence of TLF within 5 years after operation. Results: A total of 833 patients were included in this study including 579 males (69.5%), the age was (59.3±9.1) years. And 832 (99.9%) patients completed 5-year clinical follow-up. The incidence of TLF and PoCE in the 5-year follow-up were 10.6%(86/811) and 15.5%(126/811), respectively. Stent thrombosis occurred in 1.0%(8/811) of patients. Univariate Cox regression analysis showed that vessel diameter ≤ 2.74 mm (HR=3.20,95%CI 1.90-5.39,P<0.001), lesion length ≥ 16.7 mm (HR=1.88,95%CI 1.18-2.99,P=0.007) and multivessel disease (HR=2.44,95%CI 1.60-3.72,P<0.001) were related factors of TLF within 5 years after operation. Conclusion: EXCROSSAL stent is effective and safe in treating CAD patients with de novo coronary lesions, with low incidence of TLF and PoCE within 5 years after operation.
		                        		
		                        		
		                        		
		                        			Aged
		                        			;
		                        		
		                        			Cardiovascular Agents
		                        			;
		                        		
		                        			China
		                        			;
		                        		
		                        			Coronary Artery Disease/surgery*
		                        			;
		                        		
		                        			Drug-Eluting Stents
		                        			;
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Male
		                        			;
		                        		
		                        			Middle Aged
		                        			;
		                        		
		                        			Percutaneous Coronary Intervention
		                        			;
		                        		
		                        			Polymers
		                        			;
		                        		
		                        			Risk Factors
		                        			;
		                        		
		                        			Sirolimus/therapeutic use*
		                        			;
		                        		
		                        			Time Factors
		                        			;
		                        		
		                        			Treatment Outcome
		                        			
		                        		
		                        	
5.Case-control study on polymer polylactic acid absorbable medical film for preventing acromion adhesion after arthroscopic rotator cuff repair.
Wei LIN ; Huan XU ; Hai-Lin XING ; Rong-Zong ZHENG ; Jin-He YING
China Journal of Orthopaedics and Traumatology 2018;31(3):228-231
OBJECTIVETo study effect of shoulder joint function after rotator cuff repair of polylactic acid absorbable membrane.
METHODSFrom September 2015 to December 2016, 50 patients diagnosed with rotator cuff tear were selected and divided into treatment group and control group. There were 25 patients in control group, including 12 males and 13 females, with an average age of (48.7±3.5) years old, who received simple arthroscopic rotator cuff repair. There were 25 patients in treatment group, including 11 males and 14 females, with an average age of(49.2±4.1) years old, who performed arthroscopic rotator cuff repair with implanting polylactic acid absorbable membraneon shoulder of rotator cuff. Preoperative and postoperative VAS score, ASES score and UCLA score were recorded and compared between two groups.
RESULTSAt 6 months after operation, preoperative VAS score in control group was 5.48±1.12, and decreased as 1.28±0.84 after operation; ASES score before operation was 52.24±4.64, and improved to 86.92±3.20 after operation;preoperative UCLA score improved from 14.36±1.89 before operation to 30.72±1.28 after operation. In treatment group, VAS score decreased from 5.36±1.32 before operation to 1.40±0.71 after operation;preoperative ASES score was 51.04±4.09, and improved to 88.96±2.79 after operation; UCLA score improved from 15.12±1.81 before operation to 32.12±1.33 after operation. There was no significant difference in VAS score between two groups, and ASES score, UCLA score in treatment group was obviously better than control group.
CONCLUSIONSApplication of polylactic acid absorbable medical membrane could obviously improve shoulder function, and effectively prevent acromion adhesion after arthroscopic rotator cuff repair.
Acromion ; pathology ; Arthroscopy ; Case-Control Studies ; Female ; Humans ; Male ; Middle Aged ; Polyesters ; therapeutic use ; Polymers ; Range of Motion, Articular ; Rotator Cuff ; Rotator Cuff Injuries ; surgery ; Shoulder Joint ; Tissue Adhesions ; prevention & control ; Treatment Outcome
6.Hard tissue regeneration using bone substitutes: an update on innovations in materials.
Swapan Kumar SARKAR ; Byong Taek LEE
The Korean Journal of Internal Medicine 2015;30(3):279-293
		                        		
		                        			
		                        			Bone is a unique organ composed of mineralized hard tissue, unlike any other body part. The unique manner in which bone can constantly undergo self-remodeling has created interesting clinical approaches to the healing of damaged bone. Healing of large bone defects is achieved using implant materials that gradually integrate with the body after healing is completed. Such strategies require a multidisciplinary approach by material scientists, biological scientists, and clinicians. Development of materials for bone healing and exploration of the interactions thereof with the body are active research areas. In this review, we explore ongoing developments in the creation of materials for regenerating hard tissues.
		                        		
		                        		
		                        		
		                        			Animals
		                        			;
		                        		
		                        			Bone Regeneration/*drug effects
		                        			;
		                        		
		                        			Bone Substitutes/*therapeutic use
		                        			;
		                        		
		                        			Bone and Bones/*drug effects/pathology/physiopathology
		                        			;
		                        		
		                        			Ceramics/therapeutic use
		                        			;
		                        		
		                        			Diffusion of Innovation
		                        			;
		                        		
		                        			Fracture Healing/drug effects
		                        			;
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Hydrogels
		                        			;
		                        		
		                        			Polymers/therapeutic use
		                        			;
		                        		
		                        			Regenerative Medicine/*trends
		                        			;
		                        		
		                        			Tissue Engineering/*trends
		                        			;
		                        		
		                        			Treatment Outcome
		                        			
		                        		
		                        	
7.Nine-month angiographic and two-year clinical follow-up of novel biodegradable-polymer arsenic trioxide-eluting stent versus durable-polymer sirolimus-eluting stent for coronary artery disease.
Li SHEN ; Wei YANG ; Jia-Sheng YIN ; Xue-Bo LIU ; Yi-Zhe WU ; Ai-Jun SUN ; Ju-Ying QIAN ; Jun-Bo GE
Chinese Medical Journal 2015;128(6):768-773
BACKGROUNDDespite great reduction of in-stent restenosis, first-generation drug-eluting stents (DESs) have increased the risk of late stent thrombosis due to delayed endothelialization. Arsenic trioxide, a natural substance that could inhibit cell proliferation and induce cell apoptosis, seems to be a promising surrogate of sirolimus to improve DES performance. This randomized controlled trial was to evaluate the efficacy and safety of a novel arsenic trioxide-eluting stent (AES), compared with traditional sirolimus-eluting stent (SES).
METHODSPatients with symptoms of angina pectoris were enrolled and randomized to AES or SES group. The primary endpoint was target vessel failure (TVF), and the second endpoint includes rates of all-cause death, cardiac death or myocardial infarction, target lesion revascularization (TLR) by telephone visit and late luminal loss (LLL) at 9-month by angiographic follow-up.
RESULTSFrom July 2007 to 2009, 212 patients were enrolled and randomized 1:1 to receive either AES or SES. At 2 years of follow-up, TVF rate was similar between AES and SES group (6.67% vs. 5.83%, P = 0.980). Frequency of all-cause death was significantly lower in AES group (0 vs. 4.85%, P = 0.028). There was no significant difference between AES and SES in frequency of TLR and in-stent restenosis, but greater in-stent LLL was observed for AES group (0.29 ± 0.52 mm vs. 0.10 ± 0.25 mm, P = 0.008).
CONCLUSIONSAfter 2 years of follow-up, AES demonstrated comparable efficacy and safety to SES for the treatment of de novo coronary artery lesions.
Aged ; Arsenicals ; administration & dosage ; therapeutic use ; Coronary Angiography ; Coronary Artery Disease ; diagnostic imaging ; surgery ; Drug-Eluting Stents ; Female ; Follow-Up Studies ; Humans ; Male ; Middle Aged ; Oxides ; administration & dosage ; therapeutic use ; Percutaneous Coronary Intervention ; methods ; Polymers ; chemistry ; Sirolimus ; administration & dosage ; therapeutic use
8.Progress in the study of core-crosslinked polymeric micelles in drug delivery system.
Jing-Mou YU ; Jia-Zhong WU ; Xin-Shi WANG ; Yi JIN
Acta Pharmaceutica Sinica 2014;49(2):183-189
		                        		
		                        			
		                        			The core-crosslinked polymeric micelles were used as a new drug delivery system, which can decrease the premature drug release in blood circulation, improve the stability of the micelles, and effectively transport the drug into the therapy sites. Then the drug bioavailability increased further, while the side effect reduced. Most drugs were physically entrapped or chemically covalent with the polymer in the internals of micelles. Based on the various constitutions and properties of polymeric micelles as well as the special characteristics of body microenvironment, the environment-responsive or active targeting core-crosslinked micelles were designed and prepared. As a result, the drug controlled release behavior was obtained. In the present paper, the research progress of all kinds of core-crosslinked micelles which were published in recent years is introduced. Moreover, the characteristic and application prospect of these micelles in drug delivery system are analyzed and summarized.
		                        		
		                        		
		                        		
		                        			Animals
		                        			;
		                        		
		                        			Antineoplastic Agents
		                        			;
		                        		
		                        			administration & dosage
		                        			;
		                        		
		                        			chemistry
		                        			;
		                        		
		                        			therapeutic use
		                        			;
		                        		
		                        			Cross-Linking Reagents
		                        			;
		                        		
		                        			chemistry
		                        			;
		                        		
		                        			metabolism
		                        			;
		                        		
		                        			Drug Carriers
		                        			;
		                        		
		                        			chemistry
		                        			;
		                        		
		                        			metabolism
		                        			;
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Micelles
		                        			;
		                        		
		                        			Molecular Structure
		                        			;
		                        		
		                        			Neoplasms
		                        			;
		                        		
		                        			drug therapy
		                        			;
		                        		
		                        			Particle Size
		                        			;
		                        		
		                        			Pharmaceutical Preparations
		                        			;
		                        		
		                        			administration & dosage
		                        			;
		                        		
		                        			Polyethylene Glycols
		                        			;
		                        		
		                        			chemistry
		                        			;
		                        		
		                        			metabolism
		                        			;
		                        		
		                        			Polymers
		                        			;
		                        		
		                        			chemistry
		                        			;
		                        		
		                        			metabolism
		                        			
		                        		
		                        	
9.Novel completed biodegradable polymer sirolimus-eluting stent versus durable polymer sirolimus-eluting stent in de novo lesions: nine-month angiographic and three-year clinical outcomes of HOPE trial.
Fei YUAN ; Xin CHEN ; Xiantao SONG ; Dongqi WANG ; Zheng ZHANG ; Weimin LI ; Zhanquan LI ; Hui LI ; Xinyi CHEN ; Yong HUO ; Lefeng WANG ; Caiyi LU ; Qinghua LU ; Bo XU ; Wei LI ; Shuzheng LYU ; null
Chinese Medical Journal 2014;127(14):2561-2566
BACKGROUNDDrug-eluting stents (DES) with durable polymer have significantly reduced restenosis and target vessel revascularization compared with bare metal stents. Durable polymer has been linked with persistent inflammation of vessel wall and delayed endothelial healing that may increase the risk of late and very late stent thrombosis. This study sought to evaluate the efficacy and safety of HELIOS completed biodegradable polymer sirolimus-eluting stent (SES) in de novo coronary lesions.
METHODSTotally, 287 patients with one or two de novo coronary lesions (lesion length ≤ 38 mm and reference vessel diameter 2.5-4.0 mm) were enrolled in the HOPE study, a prospective, multicenter, randomized, non-inferiority trial. Patients were randomized to treatment either with HELIOS completed biodegradable polymer SES (n = 142) or PARTNER durable polymer SES (n = 145). The primary endpoint was angiographic in-stent late lumen loss (LLL) at 9-month follow-up. The secondary endpoint included stent thrombosis and major adverse cardiac events including cardiac death, myocardial infarction (MI) and target lesion revascularization (TLR).
RESULTSThe 9-month in-stent LLL in the HELIOS group was similar to the PARTNER group, (0.16 ± 0.22) mm vs. (0.19 ± 0.30) mm (P = 0.28). The difference and 95% confidence interval were -0.03 (-0.09, 0.04), and the P value for non-inferiority <0.01. Major adverse cardiovascular event (MACE) occurred in 7.9% vs. 8.2%, MI in 2.4% vs. 3.0%, TLR in 5.5% vs. 3.0%, and stent thrombosis in 0 vs. 1.5%; and events were comparable between the HELIOS group and PARTNER group at three-year follow-up (all P > 0.05). The three-year cardiac death was lower in the HELIOS group, but with no significant difference, 0 vs. 3.0% (P = 0.12).
CONCLUSIONSIn the HOPE trial, the novel completed biodegradable polymer SES HELIOS was non-inferior to the durable polymer SES PARTNER with respect to nine-month in-stent LLL in de novo coronary lesions. The incidence of other clinical endpoints was low for both of the stents in three-year follow-up.
Adult ; Aged ; Angiography ; Coronary Artery Disease ; surgery ; Coronary Restenosis ; prevention & control ; Drug-Eluting Stents ; Humans ; Middle Aged ; Percutaneous Coronary Intervention ; Polymers ; chemistry ; therapeutic use ; Sirolimus ; therapeutic use ; Titanium ; chemistry ; Treatment Outcome ; Young Adult
            
Result Analysis
Print
Save
E-mail