1. Establishment and genotype identification of hepatic stellate cell-specific Grk2 gene knockout mouse model
Yu-Han WANG ; Ya-Ping XU ; Nan LI ; Ting-Ting CHEN ; Ling LI ; Ping-Ping GAO ; Wei WEI ; Wu-Yi SUN ; Hua WANG
Chinese Pharmacological Bulletin 2024;40(1):189-194
Aim To establish a stable hepatic stellate cell ( HSC ) -specific G protein-coupled receptor kinase 2 ( GRK2 ) knockout mice and provide the important animal model for further studying the biological function of GRK2 in HSC. Methods The loxP-labeled Grk2 gene mouse (Grk2
2. Expression and distribution of brain⁃derived neurotrophic factor in different cerebrum regions of yak and cattle
Li-Ping ZHENG ; Xiao-Hua DU ; Ya-Juan WU ; Shan-Shan LIU ; Xia LIU
Acta Anatomica Sinica 2024;55(1):10-16
Objective To clarify the expression and distribution of brain⁃derived neurotrophic factor (BDNF) in the cerebrum of plateau yaks and cattle, and to explore the relationship between BDNF function and the adaptability of altitude hypoxia. Methods Five yaks and five cattles were selected.The content and distribution of BDNF in frontal lobe, temporal lobe, parietal lobe, occipital lobe, cerebrum white matter and hippocampus of yak and cattle were analyzed by Real⁃time PCR, Western blotting and Immunohistochemistry. Results Real⁃time PCR result showed that BDNF mRNA expression in the cerebrum of yaks and cattles was highest in temporal cortex, followed by hippocampus, parietal cortex, occipital cortex and frontal cortex, and lowest in white matter. Western blotting results showed that the content of BDNF protein in the cerebrum of yaks was the highest in temporal cortex,followed by hippocampus. The content of BDNF protein in other tissues was parietal cortex, frontal cortex and cerebrum white matter, and the content of BDNF protein was the lowest in occipital cortex. The content of BDNF protein intlecerebrum of cattles was the highest in the temporal cortex, followed by the hippocampus. The content of BDNF protein in other tissues was parietal cortex, occipital cortex and frontal cortex in descending order, and the protein content in cerebrum white matter was the lowest. Immunohistochemical results showed that the positive expression of BDNF protein in the cerebrum of yaks and cattles was basically similar, mainly distributed in the granulosa cells and glial cells in the frontal cortex, temporal cortex, parietal cortex and occipital cortex, glial cells in cerebrum white matter, pyramidal cell layer and polyform cell layer in the hippocampus. There was the small amount of distribution in Martinotti cells and the molecular layer of hippocampus in the cerebral cortex. Conclusion BDNF mRNA and protein are distributed and expressed in different brain regions of yaks and cattles, but the expression level different, which is speculated to be closely related to the specific functions of different cerebrum regions. The expression level of the cerebrum of yak is higher than that of cattle except occipital cortex, suggesting that it is related to the altitude hypoxic environment. BDNF may play an important role in enhancing hypoxic tolerance and protecting internal environmental homeostasis in the process of animal adaptation to hypoxic environment.
3.Research progress of natural product evodiamine-based antitumor drug design strategies
Zhe-wei XIA ; Yu-hang SUN ; Tian-le HUANG ; Hua SUN ; Yu-ping CHEN ; Chun-quan SHENG ; Shan-chao WU
Acta Pharmaceutica Sinica 2024;59(3):532-542
Natural products are important sources for the discovery of anti-tumor drugs. Evodiamine is the main alkaloid component of the traditional Chinese herb Wu-Chu-Yu, and it has weak antitumor activity. In recent years, a number of highly active antitumor candidates have been discovered with a significant progress. This article reviews the research progress of evodiamine-based antitumor drug design strategies, in order to provide reference for the development of new drugs with natural products as leads.
4.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
5.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
6.The value of CEA, CYFRA21-1 and CA125 tests in opportunistic screening for non-small cell lung cancer: a meta-analysis
Honghai HE ; Huihui ZHANG ; Hua WU ; Hongli WANG ; Wei ZHAO ; Ping SUN ; Peng WANG
Chinese Journal of Health Management 2024;18(4):254-262
Objective:To evaluate the value of CEA, CYFRA21-1 and CA125 tests in opportunistic screening of non-small cell lung cancer (NSCLC) based on meta-analysis.Methods:The original research literatures on the diagnostic value of CEA, CYFRA21-1 and CA125 in Chinese NSCLC patients were searched from databases of PubMed, Embase, The Cochrane Library, CNKI, VIP, Database and Wanfang database from establishment to June 2023. The literature screening, data extraction and quality evaluation were carried out independently by two researchers. The quality evaluation tool of diagnostic accuracy studies was used to evaluate the quality of the literature. A summary receiver operating characteristic (SROC) curve was used to assess the overall effectiveness of the tests. The outcome stability and publication bias were detected by using sensitivity analysis and Deeks′ test.Results:A total of 23 studies met the inclusion and exclusion criteria were included. The results of meta-analysis showed that the overall sensitivity of CEA, CYFRA21-1 and CA125 alone in the diagnosis of NSCLC was relatively low, it was 0.49(95% CI: 0.43-0.55), 0.56(95% CI: 0.49-0.63) and 0.41(95% CI: 0.33-0.49), respectively. The overall sensitivity of the combined detection of the three markers for the diagnosis of NSCLC increased to 0.83(95% CI: 0.69-0.91), but the overall specificity decreased to 0.76(95% CI: 0.69-0.83). Conclusions:The single detection of CEA, CYFRA21-1 and CA125 is not recommended for screening NSCLC in population receiving physical examination. Although the sensitivity of the combined detection of CEA, CYFRA21-1 and CA125 for screening NSCLC is improved, but the specificity is decreased, the misdiagnosis rate is increased, so the screening effect is limited.
7.Efficacy of different concentrations of ZKY001 eyedrops in the treatment of corneal epithelial defect after primary pterygium excision
Hua GAO ; Lei ZHU ; Jianjiang XU ; Liming TAO ; Yanling DONG ; Luxia CHEN ; Xiuming JIN ; Guigang LI ; Huping WU ; Ping ZHAO ; Wei CHEN ; Xiaoyi LI ; Weiyun SHI
International Eye Science 2024;24(12):1888-1894
AIM: To investigate the efficacy and safety of ZKY001 eye drops with different concentrations in the treatment of corneal epithelial defects(CED)after primary pterygium excision.METHODS: This was a multicenter, randomized, double-blinded, placebo-controlled phase II clinical trial. From March 15, 2022 to November 14, 2022, patients with primary pterygium who had undergone surgery were recruited from 12 tertiary hospitals across China. Using block randomization, 178 patients(178 eyes)were randomly assigned to 3 groups in a 1:1:1 ratio: 0.002% ZKY001 group(n=59), 0.004% ZKY001 group(n=59), and placebo group(n=60, receiving ZKY001 sham eye drops). Subjects in each group received 1 drop of the study drug 4 times per day for 4 d. The percentage of CED area recovery from baseline, the first complete healing time of CED area, the number of first complete healing cases of CED, and changes in visual analogue scale(VAS)scores for eye discomfort including eye pain, foreign body sensation, tearing and photophobia were observed.RESULTS: In terms of improvement in CED, there were no statistically significant differences among the three groups including the first healing time of CED, the percentage improvement in CED area compared to baseline, and the percentage of first healing cases at different follow-up visits(all P>0.05). Numerically, the first healing time of CED was shorter in the test groups compared to the placebo group(67.87±21.688 h for the 0.002% ZKY001 group, 61.48±22.091 h for the 0.004% ZKY001 group, and 68.85±20.851 h for the placebo group). On D1 morning, the percentage improvement in CED area compared to baseline was maximally different from the placebo group, and the numerical difference advantage was maintained at subsequent follow-up visits. The number of first healing cases in the CED area at different follow-up visits was higher in the test groups than the placebo group. In terms of improvement in ocular discomfort, the total VAS scores were lower in the test groups compared to the placebo group, mainly due to reductions in foreign body sensation and pain scores. At D3, the 0.004% ZKY001 group showed statistically significant improvement in foreign body sensation(P<0.017). In terms of safety, the overall incidence of adverse events was low(9.0%)and similar among groups.CONCLUSION: The use of ZKY001 eyedrops after primary pterygium surgery can safely improve the CED repair, and alleviate postoperative symptoms caused by CED.
8.Bioequivalence study of sidenafil citrate tablets in Chinese healthy subjects
Xiao-Bin LI ; Lu CHEN ; Xiu-Jun WU ; Yu-Xin GE ; Wen-Chao LU ; Ting XIAO ; He XIE ; Hua-Wei WANG ; Wen-Ping WANG
The Chinese Journal of Clinical Pharmacology 2024;40(3):430-434
Objective To evaluate the bioequivalence of oral sidenafil citrate tablets manufactured(100 mg)test preparations and reference preparations in healthy subjects under fasting and fed conditions.Methods Using a single-dose,randomized,open-lable,two-period,two-way crossover design,36 healthy subjects respectively for fasting and fed study were enrolled,and randomized into two groups to receive a single dose of test 100 mg with 7-day washout period.Plasma concentration of sidenafil and N-demethylsildenafil was determined by liquid chromatography-tandem mass spectrometry(LC-MS/MS)method.The pharmacokinetic parameters were calculated by Analyst 1.6.3(AB Scie)using non-compartmental model,and bioequivalence evaluation was performed for the two preparations.Relevant safety evaluations were performed during the trial.Results The main pharmacokinetic parameters of sidenafil after a single oral dose of sidenafil citrate tablets under fasting condition for test and reference were as follows:Cmax were(494.69±230.94)and(558.78±289.83)ng·mL-1,AUC0-t were(1 336.21±509.78)and(1 410.82±625.99)h·ng·mL-1,AUC0-were(1 366.49±512.16)and(1 441.84±628.04)h·ng·mL-1,respectively.The main pharmacokinetic parameters of sidenafil under fed condition for T and R were as follows:Cmax were(381.89±126.53)and(432.47±175.91)ng·mL-1,AUC0-t were(1 366.34±366.99)and(1 412.76±420.37)h·ng·mL-1,AUC0-were(1 403.28±375.32)and(1 454.13±429.87)h·ng·mL-1,respectively.The results demonstrated the bioequivalence of sidenafil citrate tablets between T and R.The incidence of adverse events in fasting and fed tests were 33.33%and 25.00%,respectively.No serious adverse event was reported.Conclusion The test and reference formulation of sidenafil citrate tablets were equivalent and was safe.
9.Advances in Quantification and Site Stoichiometry Analysis Methods for Phosphorylated Proteins
Yuan LIU ; Rui ZHAI ; Fan WU ; Zhan-Ying CHU ; Yang ZHAO ; Xin-Hua DAI ; Xiang FANG ; Xiao-Ping YU
Chinese Journal of Analytical Chemistry 2024;52(5):609-623
The post-translational modification of proteins is a key mechanism that imparts physiological functions to proteins,among which reversible phosphorylation modifications play a pivotal role in many biological processes.Aberrant changes in phosphorylation are often closely associated with various major disease processes.In recent years,with the aid of proteomic technologies and methods,high-throughput,high-precision qualitative and quantitative approaches for phosphorylated proteins have rapidly advanced.This article reviews the research progress of phosphorylated protein quantification and chemical proteomics analysis methods based on the"bottom-up"strategy,including phosphopeptide enrichment methods,mass spectrometry fragmentation methods,quantification analysis methods and phosphorylation site stoichiometry,and discusses the development trend of quantification and stoichiometric analysis methods for phosphorylated proteins.
10.Relationship between Phenotypic Changes of Dendritic Cell Subsets and the Onset of Plateau Phase during Intermittent Interferon Therapy in Patients with CHB
Liu YANG ; Yu Shi WANG ; Ting Ting JIANG ; Wen DENG ; Min CHANG ; Ling Shu WU ; Hua Wei CAO ; Yao LU ; Ge SHEN ; Yu Ru LIU ; Jiao Yuan GAO ; Jiao Meng XU ; Ping Lei HU ; Lu ZHANG ; Yao XIE ; Hui Ming LI
Biomedical and Environmental Sciences 2024;37(3):303-314
Objective This study aimed to evaluate whether the onset of the plateau phase of slow hepatitis B surface antigen decline in patients with chronic hepatitis B treated with intermittent interferon therapy is related to the frequency of dendritic cell subsets and expression of the costimulatory molecules CD40,CD80,CD83,and CD86. Method This was a cross-sectional study in which patients were divided into a natural history group(namely NH group),a long-term oral nucleoside analogs treatment group(namely NA group),and a plateau-arriving group(namely P group).The percentage of plasmacytoid dendritic cell and myeloid dendritic cell subsets in peripheral blood lymphocytes and monocytes and the mean fluorescence intensity of their surface costimulatory molecules were detected using a flow cytometer. Results In total,143 patients were enrolled(NH group,n = 49;NA group,n = 47;P group,n = 47).The results demonstrated that CD141/CD1c double negative myeloid dendritic cell(DNmDC)/lymphocytes and monocytes(%)in P group(0.041[0.024,0.069])was significantly lower than that in NH group(0.270[0.135,0.407])and NA group(0.273[0.150,0.443]),and CD86 mean fluorescence intensity of DNmDCs in P group(1832.0[1484.0,2793.0])was significantly lower than that in NH group(4316.0[2958.0,5169.0])and NA group(3299.0[2534.0,4371.0]),Adjusted P all<0.001. Conclusion Reduced DNmDCs and impaired maturation may be associated with the onset of the plateau phase during intermittent interferon therapy in patients with chronic hepatitis B.

Result Analysis
Print
Save
E-mail