1.Research progress of cAMP/PKA signaling pathway in glaucoma optic neuropathy
Hongda CUI ; Yu HUANG ; Xin XIA ; Jiangwei LI ; Qinghua PENG
International Eye Science 2025;25(10):1598-1603
		                        		
		                        			
		                        			 Glaucoma is a multifactorial degenerative optic neuropathy, and its irreversible and blinding pathological characteristics mainly come from the damage to the optic nerve, namely glaucomatous optic neuropathy(GON). The difficulty in the treatment of GON lies in the early intervention, and currently there is no optic neuroprotective drug for the treatment of all types of GON. The death of retinal ganglion cells(RGCs)is the core pathological change caused by various pathogenic mechanisms of GON. Recent studies have found that the widespread second messenger cyclic adenosine 3', 5' -monophosphate(cAMP)and its downstream effector protein kinase A(PKA)signal cascade play an important role in the pathogenesis of GON. It can also inhibit the apoptosis of RGCs and play a protective and therapeutic role in glaucoma. Therefore, this article reviews the role of cAMP/PKA pathway in the pathophysiological development of GON, focusing on its effects on glaucoma intraocular pressure regulation, oxidative stress, neuroinflammation and optic nerve degeneration, in order to find a common central regulatory target for the optic nerve damage caused by different pathological mechanisms of GON and promote the further understanding and clinical treatment of this disease. 
		                        		
		                        		
		                        		
		                        	
2.Application of CRISPR/Cas System in Precision Medicine for Triple-negative Breast Cancer
Hui-Ling LIN ; Yu-Xin OUYANG ; Wan-Ying TANG ; Mi HU ; Mao PENG ; Ping-Ping HE ; Xin-Ping OUYANG
Progress in Biochemistry and Biophysics 2025;52(2):279-289
		                        		
		                        			
		                        			Triple-negative breast cancer (TNBC) represents a distinctive subtype, characterized by the absence of estrogen receptors, progesterone receptors, and human epidermal growth factor receptor 2 (HER2). Due to its high inter-tumor and intra-tumor heterogeneity, TNBC poses significant chanllenges for personalized diagnosis and treatment. The advant of clustered regular interspaced short palindromic repeats (CRISPR) technology has profoundly enhanced our understanding of the structure and function of the TNBC genome, providing a powerful tool for investigating the occurrence and development of diseases. This review focuses on the application of CRISPR/Cas technology in the personalized diagnosis and treatment of TNBC. We begin by discussing the unique attributes of TNBC and the limitations of current diagnostic and treatment approaches: conventional diagnostic methods provide limited insights into TNBC, while traditional chemotherapy drugs are often associated with low efficacy and severe side effects. The CRISPR/Cas system, which activates Cas enzymes through complementary guide RNAs (gRNAs) to selectively degrade specific nucleic acids, has emerged as a robust tool for TNBC research. This technology enables precise gene editing, allowing for a deeper understanding of TNBC heterogeneity by marking and tracking diverse cell clones. Additionally, CRISPR facilitates high-throughput screening to promptly identify genes involved in TNBC growth, metastasis, and drug resistance, thus revealing new therapeutic targets and strategies. In TNBC diagnostics, CRISPR/Cas was applied to develop molecular diagnostic systems based on Cas9, Cas12, and Cas13, each employing distinct detection principles. These systems can sensitively and specifically detect a variety of TNBC biomarkers, including cell-specific DNA/RNA and circulating tumor DNA (ctDNA). In the realm of precision therapy, CRISPR/Cas has been utilized to identify key genes implicated in TNBC progression and treatment resistance. CRISPR-based screening has uncovered potential therapeutic targets, while its gene-editing capabilities have facilitated the development of combination therapies with traditional chemotherapy drugs, enhancing their efficacy. Despite its promise, the clinical translation of CRISPR/Cas technology remains in its early stages. Several clinical trials are underway to assess its safety and efficacy in the treatment of various genetic diseases and cancers. Challenges such as off-target effects, editing efficiency, and delivery methods remain to be addressed. The integration of CRISPR/Cas with other technologies, such as 3D cell culture systems, human induced pluripotent stem cells (hiPSCs), and artificial intelligence (AI), is expected to further advance precision medicine for TNBC. These technological convergences can offer deeper insights into disease mechanisms and facilitate the development of personalized treatment strategies. In conclusion, the CRISPR/Cas system holds immense potential in the precise diagnosis and treatment of TNBC. As the technology progresses and becomes more costs-effective, its clinical relevance will grow, and the translation of CRISPR/Cas system data into clinical applications will pave the way for optimal diagnosis and treatment strategies for TNBC patients. However, technical hurdles and ethical considerations require ongoing research and regulation to ensure safety and efficacy. 
		                        		
		                        		
		                        		
		                        	
3.Research and Application of Scalp Surface Laplacian Technique
Rui-Xin LUO ; Si-Ying GUO ; Xin-Yi LI ; Yu-He ZHAO ; Chun-Hou ZHENG ; Min-Peng XU ; Dong MING
Progress in Biochemistry and Biophysics 2025;52(2):425-438
		                        		
		                        			
		                        			Electroencephalogram (EEG) is a non-invasive, high temporal-resolution technique for monitoring brain activity. However, affected by the volume conduction effect, EEG has a low spatial resolution and is difficult to locate brain neuronal activity precisely. The surface Laplacian (SL) technique obtains the Laplacian EEG (LEEG) by estimating the second-order spatial derivative of the scalp potential. LEEG can reflect the radial current activity under the scalp, with positive values indicating current flow from the brain to the scalp (“source”) and negative values indicating current flow from the scalp to the brain (“sink”). It attenuates signals from volume conduction, effectively improving the spatial resolution of EEG, and is expected to contribute to breakthroughs in neural engineering. This paper provides a systematic overview of the principles and development of SL technology. Currently, there are two implementation paths for SL technology: current source density algorithms (CSD) and concentric ring electrodes (CRE). CSD performs the Laplace transform of the EEG signals acquired by conventional disc electrodes to indirectly estimate the LEEG. It can be mainly classified into local methods, global methods, and realistic Laplacian methods. The global method is the most commonly used approach in CSD, which can achieve more accurate estimation compared with the local method, and it does not require additional imaging equipment compared with the realistic Laplacian method. CRE employs new concentric ring electrodes instead of the traditional disc electrodes, and measures the LEEG directly by differential acquisition of the multi-ring signals. Depending on the structure, it can be divided into bipolar CRE, quasi-bipolar CRE, tripolar CRE, and multi-pole CRE. The tripolar CRE is widely used due to its optimal detection performance. While ensuring the quality of signal acquisition, the complexity of its preamplifier is relatively acceptable. Here, this paper introduces the study of the SL technique in resting rhythms, visual-related potentials, movement-related potentials, and sensorimotor rhythms. These studies demonstrate that SL technology can improve signal quality and enhance signal characteristics, confirming its potential applications in neuroscientific research, disease diagnosis, visual pathway detection, and brain-computer interfaces. CSD is frequently utilized in applications such as neuroscientific research and disease detection, where high-precision estimation of LEEG is required. And CRE tends to be used in brain-computer interfaces, that have stringent requirements for real-time data processing. Finally, this paper summarizes the strengths and weaknesses of SL technology and envisages its future development. SL technology boasts advantages such as reference independence, high spatial resolution, high temporal resolution, enhanced source connectivity analysis, and noise suppression. However, it also has shortcomings that can be further improved. Theoretically, simulation experiments should be conducted to investigate the theoretical characteristics of SL technology. For CSD methods, the algorithm needs to be optimized to improve the precision of LEEG estimation, reduce dependence on the number of channels, and decrease computational complexity and time consumption. For CRE methods, the electrodes need to be designed with appropriate structures and sizes, and the low-noise, high common-mode rejection ratio preamplifier should be developed. We hope that this paper can promote the in-depth research and wide application of SL technology. 
		                        		
		                        		
		                        		
		                        	
4.Study of adsorption of coated aldehyde oxy-starch on the indexes of renal failure
Qian WU ; Cai-fen WANG ; Ning-ning PENG ; Qin NIE ; Tian-fu LI ; Jian-yu LIU ; Xiang-yi SONG ; Jian LIU ; Su-ping WU ; Ji-wen ZHANG ; Li-xin SUN
Acta Pharmaceutica Sinica 2025;60(2):498-505
		                        		
		                        			
		                        			 The accumulation of uremic toxins such as urea nitrogen, blood creatinine, and uric acid of patients with renal failure 
		                        		
		                        	
5.Relationship between ocular parameters and lens thickness in myopic patients with varying anterior chamber depth
International Eye Science 2025;25(5):826-830
		                        		
		                        			
		                        			 AIM:To study the relationship between ocular parameters and lens thickness(LT)in myopic patients with different anterior chamber depth(ACD).METHODS:Cross-sectional study. A total of 118 myopic subjects(236 eyes)underwent posterior chamber phakic implantable collamer lens(Phakic-ICL)implantation in the refractive department of our hospital from May 2022 to May 2024 were selected. Ocular parameters examined before surgery included uncorrected visual acuity(UCVA), subjective refraction, best corrected visual acuity(BCVA), contactless intraocular pressure(IOP), ACD, white-to-white(WTW), horizontal sulcus-to-sulcus(STSH), vertical sulcus-to-sulcus(STSV), and LT. ACD without corneal thickness was measured by Pentacam, and subjects were divided into three groups: shallow anterior chamber group(2.8 mm≤ACD≤3.2 mm), middle anterior chamber group(3.2 mm
		                        		
		                        	
6.Discriminating Tumor Deposits From Metastatic Lymph Nodes in Rectal Cancer: A Pilot Study Utilizing Dynamic Contrast-Enhanced MRI
Xue-han WU ; Yu-tao QUE ; Xin-yue YANG ; Zi-qiang WEN ; Yu-ru MA ; Zhi-wen ZHANG ; Quan-meng LIU ; Wen-jie FAN ; Li DING ; Yue-jiao LANG ; Yun-zhu WU ; Jian-peng YUAN ; Shen-ping YU ; Yi-yan LIU ; Yan CHEN
Korean Journal of Radiology 2025;26(5):400-410
		                        		
		                        			 Objective:
		                        			To evaluate the feasibility of dynamic contrast-enhanced MRI (DCE-MRI) in differentiating tumor deposits (TDs) from metastatic lymph nodes (MLNs) in rectal cancer. 
		                        		
		                        			Materials and Methods:
		                        			A retrospective analysis was conducted on 70 patients with rectal cancer, including 168 lesions (70 TDs and 98 MLNs confirmed by histopathology), who underwent pretreatment MRI and subsequent surgery between March 2019 and December 2022. The morphological characteristics of TDs and MLNs, along with quantitative parameters derived from DCE-MRI (K trans , kep, and v e) and DWI (ADCmin, ADCmax, and ADCmean), were analyzed and compared between the two groups.Multivariable binary logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the diagnostic performance of significant individual quantitative parameters and combined parameters in distinguishing TDs from MLNs. 
		                        		
		                        			Results:
		                        			All morphological features, including size, shape, border, and signal intensity, as well as all DCE-MRI parameters showed significant differences between TDs and MLNs (all P < 0.05). However, ADC values did not demonstrate significant differences (all P > 0.05). Among the single quantitative parameters, v e had the highest diagnostic accuracy, with an area under the ROC curve (AUC) of 0.772 for distinguishing TDs from MLNs. A multivariable logistic regression model incorporating short axis, border, v e, and ADC mean improved diagnostic performance, achieving an AUC of 0.833 (P = 0.027). 
		                        		
		                        			Conclusion
		                        			The combination of morphological features, DCE-MRI parameters, and ADC values can effectively aid in the preoperative differentiation of TDs from MLNs in rectal cancer. 
		                        		
		                        		
		                        		
		                        	
7.Discriminating Tumor Deposits From Metastatic Lymph Nodes in Rectal Cancer: A Pilot Study Utilizing Dynamic Contrast-Enhanced MRI
Xue-han WU ; Yu-tao QUE ; Xin-yue YANG ; Zi-qiang WEN ; Yu-ru MA ; Zhi-wen ZHANG ; Quan-meng LIU ; Wen-jie FAN ; Li DING ; Yue-jiao LANG ; Yun-zhu WU ; Jian-peng YUAN ; Shen-ping YU ; Yi-yan LIU ; Yan CHEN
Korean Journal of Radiology 2025;26(5):400-410
		                        		
		                        			 Objective:
		                        			To evaluate the feasibility of dynamic contrast-enhanced MRI (DCE-MRI) in differentiating tumor deposits (TDs) from metastatic lymph nodes (MLNs) in rectal cancer. 
		                        		
		                        			Materials and Methods:
		                        			A retrospective analysis was conducted on 70 patients with rectal cancer, including 168 lesions (70 TDs and 98 MLNs confirmed by histopathology), who underwent pretreatment MRI and subsequent surgery between March 2019 and December 2022. The morphological characteristics of TDs and MLNs, along with quantitative parameters derived from DCE-MRI (K trans , kep, and v e) and DWI (ADCmin, ADCmax, and ADCmean), were analyzed and compared between the two groups.Multivariable binary logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the diagnostic performance of significant individual quantitative parameters and combined parameters in distinguishing TDs from MLNs. 
		                        		
		                        			Results:
		                        			All morphological features, including size, shape, border, and signal intensity, as well as all DCE-MRI parameters showed significant differences between TDs and MLNs (all P < 0.05). However, ADC values did not demonstrate significant differences (all P > 0.05). Among the single quantitative parameters, v e had the highest diagnostic accuracy, with an area under the ROC curve (AUC) of 0.772 for distinguishing TDs from MLNs. A multivariable logistic regression model incorporating short axis, border, v e, and ADC mean improved diagnostic performance, achieving an AUC of 0.833 (P = 0.027). 
		                        		
		                        			Conclusion
		                        			The combination of morphological features, DCE-MRI parameters, and ADC values can effectively aid in the preoperative differentiation of TDs from MLNs in rectal cancer. 
		                        		
		                        		
		                        		
		                        	
8.Discriminating Tumor Deposits From Metastatic Lymph Nodes in Rectal Cancer: A Pilot Study Utilizing Dynamic Contrast-Enhanced MRI
Xue-han WU ; Yu-tao QUE ; Xin-yue YANG ; Zi-qiang WEN ; Yu-ru MA ; Zhi-wen ZHANG ; Quan-meng LIU ; Wen-jie FAN ; Li DING ; Yue-jiao LANG ; Yun-zhu WU ; Jian-peng YUAN ; Shen-ping YU ; Yi-yan LIU ; Yan CHEN
Korean Journal of Radiology 2025;26(5):400-410
		                        		
		                        			 Objective:
		                        			To evaluate the feasibility of dynamic contrast-enhanced MRI (DCE-MRI) in differentiating tumor deposits (TDs) from metastatic lymph nodes (MLNs) in rectal cancer. 
		                        		
		                        			Materials and Methods:
		                        			A retrospective analysis was conducted on 70 patients with rectal cancer, including 168 lesions (70 TDs and 98 MLNs confirmed by histopathology), who underwent pretreatment MRI and subsequent surgery between March 2019 and December 2022. The morphological characteristics of TDs and MLNs, along with quantitative parameters derived from DCE-MRI (K trans , kep, and v e) and DWI (ADCmin, ADCmax, and ADCmean), were analyzed and compared between the two groups.Multivariable binary logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the diagnostic performance of significant individual quantitative parameters and combined parameters in distinguishing TDs from MLNs. 
		                        		
		                        			Results:
		                        			All morphological features, including size, shape, border, and signal intensity, as well as all DCE-MRI parameters showed significant differences between TDs and MLNs (all P < 0.05). However, ADC values did not demonstrate significant differences (all P > 0.05). Among the single quantitative parameters, v e had the highest diagnostic accuracy, with an area under the ROC curve (AUC) of 0.772 for distinguishing TDs from MLNs. A multivariable logistic regression model incorporating short axis, border, v e, and ADC mean improved diagnostic performance, achieving an AUC of 0.833 (P = 0.027). 
		                        		
		                        			Conclusion
		                        			The combination of morphological features, DCE-MRI parameters, and ADC values can effectively aid in the preoperative differentiation of TDs from MLNs in rectal cancer. 
		                        		
		                        		
		                        		
		                        	
9.Temporomandibular joint capsule suspension for neocondyle stability in free fibular flap reconstruction of the mandibular condyle
Shuang BAI ; Yao YU ; Wen-Bo ZHANG ; Ya-Qing MAO ; Yang WANG ; Chi MAO ; Dian-Can WANG ; Xin PENG
Journal of the Korean Association of Oral and Maxillofacial Surgeons 2025;51(1):46-53
		                        		
		                        			 Objectives:
		                        			This study evaluates the efficacy of a new temporomandibular joint (TMJ) capsule suspension technique for stabilizing the TMJ after free fibular flap reconstruction of the mandibular condyle. 
		                        		
		                        			Patients and Methods:
		                        			Patients undergoing the TMJ capsule suspension technique during free fibular flap reconstruction after mandibulectomy with condylectomy (study group; n=9) were compared with a control group (n=9). Mandibular movement trajectory and surface electromyographic signals of bilateral masseters were recorded. The neocondyle–disc relationship was examined with magnetic resonance imaging (MRI) at 6 months after surgery. 
		                        		
		                        			Results:
		                        			Maximal mouth opening and bilateral marginal movement distances were comparable between the two groups (P>0.05). The asymmetry index of the condyle path length was significantly higher in controls (P=0.02). Bilateral mouth opening trajectories were symmetric in 7 patients and deviated to the affected side in 2 patients in the study group; they deviated to the affected side in all controls. The mean electromyographic values of the masseter on the affected side in resting, maximum bite, and chewing states were comparable between the two groups (P=0.13, P=0.65, and P=0.82, respectively). On MRI at 6 months, the thicknesses of the anterior, medial, and posterior bands and TMJ disc length were similar on the affected and normal sides in the study group (P=0.57, P=0.13, P=0.48, and P=0.87, respectively). 
		                        		
		                        			Conclusion
		                        			The proposed TMJ capsule suspension technique could improve postoperative TMJ structure and function after fibular free flap reconstruction following mandibulectomy with condylectomy. 
		                        		
		                        		
		                        		
		                        	
10.Temporomandibular joint capsule suspension for neocondyle stability in free fibular flap reconstruction of the mandibular condyle
Shuang BAI ; Yao YU ; Wen-Bo ZHANG ; Ya-Qing MAO ; Yang WANG ; Chi MAO ; Dian-Can WANG ; Xin PENG
Journal of the Korean Association of Oral and Maxillofacial Surgeons 2025;51(1):46-53
		                        		
		                        			 Objectives:
		                        			This study evaluates the efficacy of a new temporomandibular joint (TMJ) capsule suspension technique for stabilizing the TMJ after free fibular flap reconstruction of the mandibular condyle. 
		                        		
		                        			Patients and Methods:
		                        			Patients undergoing the TMJ capsule suspension technique during free fibular flap reconstruction after mandibulectomy with condylectomy (study group; n=9) were compared with a control group (n=9). Mandibular movement trajectory and surface electromyographic signals of bilateral masseters were recorded. The neocondyle–disc relationship was examined with magnetic resonance imaging (MRI) at 6 months after surgery. 
		                        		
		                        			Results:
		                        			Maximal mouth opening and bilateral marginal movement distances were comparable between the two groups (P>0.05). The asymmetry index of the condyle path length was significantly higher in controls (P=0.02). Bilateral mouth opening trajectories were symmetric in 7 patients and deviated to the affected side in 2 patients in the study group; they deviated to the affected side in all controls. The mean electromyographic values of the masseter on the affected side in resting, maximum bite, and chewing states were comparable between the two groups (P=0.13, P=0.65, and P=0.82, respectively). On MRI at 6 months, the thicknesses of the anterior, medial, and posterior bands and TMJ disc length were similar on the affected and normal sides in the study group (P=0.57, P=0.13, P=0.48, and P=0.87, respectively). 
		                        		
		                        			Conclusion
		                        			The proposed TMJ capsule suspension technique could improve postoperative TMJ structure and function after fibular free flap reconstruction following mandibulectomy with condylectomy. 
		                        		
		                        		
		                        		
		                        	
            
Result Analysis
Print
Save
E-mail