1.A preliminary study of risk factors for the stress fracture in treated with clavicle hook plate.
Peng-Fei NIE ; Yuan-Lin XU ; Yong-Fu LI ; Lun ZHANG ; Qian-Qian ZHOU ; Jian-Nyu LUO ; Jian GUO
China Journal of Orthopaedics and Traumatology 2025;38(1):61-65
OBJECTIVE:
To investigate the effects of bone density, plate bending degree and proximal screw type on the stress fracture of clavicle hook.
METHODS:
Three sows weighing between 45 and 50 kg were selected, from which a total of 40 rivs were collected. The 15 ribs of sows were divided into 3 groups according to bone density and bone hardness with 5 rivs in each group. And then the 3 groups were fixed with 6-hole collarbone hook plates and 3 locking screws. Measure the maximum torsion force when the ribs were fractured by force. The same size 15 rids were divided into 3 groups, named forward bending group, 0° group(the angle between the plate surface and the rib surface) and reverse bending group. All fixed with 6-hole collarbone hook plates and locking screws to measure the maximum torsion force of rib stress fracture. Then the same size 10 rids were divided into 2 groups, the normal screw group and the locking screw group with 5 ribs in each group. Both groups were fixed with 6-hole collarbone hook plates and screws. The normal screw group was a normal screw, fixed in proximal end, and two locking screws. The locking screw group was fixed by locking screws. Measure the maximum torsion force of the two groups when the ribs fracture by force.
RESULTS:
In the bone density experiment, the torque force of hard bone group (104.51±6.27) N was greater than the normal bone group (75.04±3.81) N(t=8.979, P<0.05). The force of normal bone group was greater than the osteoporosis group (49.99±2.12) N(t=12.832, P<0.05). In the bending collarbone hook experiment, the order of the torque force generated by each group as follow:the forward bending group (343.59±6.18) N greater than the 0° group (106.01±5.29) N(t=65.279, P<0.05) greater than the reverse bending group (95.82±4.12) N(t=3.398, P<0.05). The force of the normal screw group (98.68±0.70) N was greater than the locking screw group (50.20±0.95) N(t=91.484, P<0.05). The data comparisons of each group were statistically significant.
CONCLUSION
Bone density, plate bending degree and proximal screw type had an impact on stress fracture of clavicle hook plate. Higher bone density, forward bending of the steel plate, and ordinary screws in proximal end can reduce the rates of stress fractures of clavicle hooks.
Animals
;
Bone Plates
;
Clavicle/surgery*
;
Swine
;
Fractures, Stress/etiology*
;
Female
;
Risk Factors
;
Fracture Fixation, Internal/instrumentation*
;
Bone Screws
;
Biomechanical Phenomena
;
Bone Density
2.A preclinical evaluation and first-in-man case for transcatheter edge-to-edge mitral valve repair using PulveClip® transcatheter repair device.
Gang-Jun ZONG ; Jie-Wen DENG ; Ke-Yu CHEN ; Hua WANG ; Fei-Fei DONG ; Xing-Hua SHAN ; Jia-Feng WANG ; Ni ZHU ; Fei LUO ; Peng-Fei DAI ; Zhi-Fu GUO ; Yong-Wen QIN ; Yuan BAI
Journal of Geriatric Cardiology 2025;22(2):265-269
3.NFKBIE: Novel Biomarkers for Diagnosis, Prognosis, and Immunity in Colorectal Cancer: Insights from Pan-cancer Analysis.
Chen Yang HOU ; Peng WANG ; Feng Xu YAN ; Yan Yan BO ; Zhen Peng ZHU ; Xi Ran WANG ; Shan LIU ; Dan Dan XU ; Jia Jia XIAO ; Jun XUE ; Fei GUO ; Qing Xue MENG ; Ren Sen RAN ; Wei Zheng LIANG
Biomedical and Environmental Sciences 2025;38(10):1320-1325
4.MicroRNA-451 from Human Umbilical Cord-Derived Mesenchymal Stem Cell Exosomes Inhibits Alveolar Macrophage Autophagy via Tuberous Sclerosis Complex 1/Mammalian Target of Rapamycin Pathway to Attenuate Burn-Induced Acute Lung Injury in Rats
Jia ZHIGANG ; Li LIN ; Zhao PENG ; Fei GUO ; Li SHUANGRU ; Song QINQIN ; Liu GUANGPENG ; Liu JISONG
Biomedical and Environmental Sciences 2024;37(9):1030-1043
Objective Our previous studies established that microRNA (miR)-451 from human umbilical cord mesenchymal stem cell-derived exosomes (hUC-MSC-Exos) alleviates acute lung injury (ALI). This study aims to elucidate the mechanisms by which miR-451 in hUC-MSC-Exos reduces ALI by modulating macrophage autophagy. Methods Exosomes were isolated from hUC-MSCs. Severe burn-induced ALI rat models were treated with hUC-MSC-Exos carrying the miR-451 inhibitor. Hematoxylin-eosin staining evaluated inflammatory injury. Enzyme-linked immunosorbnent assay measured lipopolysaccharide (LPS),tumor necrosis factor-α,and interleukin-1β levels. qRT-PCR detected miR-451 and tuberous sclerosis complex 1 (TSC1) expressions. The regulatory role of miR-451 on TSC1 was determined using a dual-luciferase reporter system. Western blotting determined TSC1 and proteins related to the mammalian target of rapamycin (mTOR) pathway and autophagy. Immunofluorescence analysis was conducted to examine exosomes phagocytosis in alveolar macrophages and autophagy level. Results hUC-MSC-Exos with miR-451 inhibitor reduced burn-induced ALI and promoted macrophage autophagy. MiR-451 could be transferred from hUC-MSCs to alveolar macrophages via exosomes and directly targeted TSC1. Inhibiting miR-451 in hUC-MSC-Exos elevated TSC1 expression and inactivated the mTOR pathway in alveolar macrophages. Silencing TSC1 activated mTOR signaling and inhibited autophagy,while TSC1 knockdown reversed the autophagy from the miR-451 inhibitor-induced. Conclusion miR-451 from hUC-MSC exosomes improves ALI by suppressing alveolar macrophage autophagy through modulation of the TSC1/mTOR pathway,providing a potential therapeutic strategy for ALI.
5.The value of high-throughput sequencing data reanalysis in identifying ERBB2 amplification in colorectal cancer patients
Min-Na SHEN ; Li ZHANG ; Xin-Ning CHEN ; Fei HUANG ; Chao-Gang BAI ; Li-Meng CHEN ; Hai-Xiang PENG ; Yan ZHOU ; Bei-Li WANG ; Bai-Shen PAN ; Wei GUO
Fudan University Journal of Medical Sciences 2024;51(2):166-171
Objective To evaluate the value of high-throughput sequencing(HTS)data reanalysis that does not include ERBB2 copy number variation(CNV)analysis,in identifying ERBB2 amplification in patients with colorectal cancer.Methods The HTS data of 252 cases of colorectal cancer diagnosed by pathological biopsy who received peripheral blood cfDNA HTS detection samples were retrospectively analyzed.According to the HTS data of ERBB2 non-amplified samples judged by immunohistochemistry(IHC)and/or fluorescence in situ hybridization(FISH),the number of chromosome 17(Chr17)reads in the total number of reads was calculated the range of the ratio was initially determined as the threshold for prompting ERBB2 amplification.Suspected positive samples were screened according to thresholds and verified by digital PCR,IHC and FISH.Results The proportion of the number of Chr17 reads accounts for the number of total reads in the 89 cases of ERBB2 non-amplified samples determined by IHC and/or FISH ranged from 0.188 to 0.299(0.239±0.192).Using 0.298(1.25 times the mean)as the threshold indicating ERBB2 amplification,the data of 163 samples were analyzed,of which 7 cases were suspected to be positive,and the ratio ranged from 0.302 to 0.853.Among them,5 cases were determined to be positive by IHC and/or FISH,and 6 cases were confirmed to be positive by digital PCR.The ratio of the number of Chr17 reads to the number of total reads was positively correlated with the ratio of ERBB2/EIF2C1,and the correlation was good(r2=0.909).Conclusion The high-throughput sequencing data that does not cover the ERBB2 CNV analysis has a certain hint value for ERBB2 amplification in patients with colorectal cancer.
6.Development and prospects of predicting drug polymorphs technology
Mei GUO ; Wen-xing DING ; Bo PENG ; Jin-feng LIU ; Yi-fei SU ; Bin ZHU ; Guo-bin REN
Acta Pharmaceutica Sinica 2024;59(1):76-83
Most chemical medicines have polymorphs. The difference of medicine polymorphs in physicochemical properties directly affects the stability, efficacy, and safety of solid medicine products. Polymorphs is incomparably important to pharmaceutical chemistry, manufacturing, and control. Meantime polymorphs is a key factor for the quality of high-end drug and formulations. Polymorph prediction technology can effectively guide screening of trial experiments, and reduce the risk of missing stable crystal form in the traditional experiment. Polymorph prediction technology was firstly based on theoretical calculations such as quantum mechanics and computational chemistry, and then was developed by the key technology of machine learning using the artificial intelligence. Nowadays, the popular trend is to combine the advantages of theoretical calculation and machine learning to jointly predict crystal structure. Recently, predicting medicine polymorphs has still been a challenging problem. It is expected to learn from and integrate existing technologies to predict medicine polymorphs more accurately and efficiently.
7.Clinical safety and validity analysis of retrograde new endo-scopic visual field in miniature pigs
Zhe KUANG ; Peng LI ; Da-Qing JIN ; Yong-Chao ZHANG ; Hui-Li GUO ; Yu-Fei ZHANG ; Guang-Lin HE ; Guo-Feng SUN ; Yuan HE
Chinese Journal of Current Advances in General Surgery 2024;27(1):14-18
Objective:To study the clinical safety and validity of retrograde new endoscopic field of vision in miniature pigs.Methods:6 live miniature pigs were selected as study subjects,En-doscopic Retrograde New View(ERNV)was selected.The performance,image quality and intraoper-ative and postoperative complications were evaluated.To evaluate whether all the experimental ani-mals could complete the relevant endoscopy.Verify ERNV's operating performance,including whether the duodenoscope can enter the biliary tract smoothly,and made sure whether the injection,suction,and instrument channels were unobstructed.Choledochoscope image clarity,color resolu-tion,image deformation and distortion,accurate evaluation of lumen conditions and clear observation of mucosal surface conditions were analyzed.Whether there were operant injuries such as bleeding and perforation,as well as adverse events such as respiratory depression and cardiac arrest.The sur-vival status and adverse reactions of all pigs were observed.Results:The choledochoscope was successfully inserted into the bile duct of 6 miniature pigs.The product had good operation perfor-mance and could enter the bile duct through the duodenoscope smoothly.The injection,suction and instrument channels were relatively smooth.In addition,the endoscopic images are clear,with better color resolution,and without image deformation and distortion,which can realize accurate evaluation of the conditions in the lumen and observe the mucosal surface conditions more clearly.No bile duct stenosis or dilatation occurred in all miniature pigs,and the bile duct mucosa was smooth,without hyperemia and edema,and no abnormal thickening or bending of mucous vessels.During the exami-nation,there were no operational injuries such as bleeding and perforation,and no adverse events such as respiratory depression and cardiac arrest occurred.The vital signs of all miniature pigs tended to be stable after operation,and the survival state was good,and there were no complications such as cholangitis,bleeding and perforation.Conclusion:ERNV has good clinical safety and efficacy,ex-cellent operation performance and excellent image quality,and is worthy of clinical application.
8.A novel chalcone derivative C13 inhibits the growth of human gastric cancer cells through suppressing ErbB4/PI3K/AKT signaling pathway
Peng TAN ; Yun-feng ZHANG ; Long-yan WANG ; Hui-ming HUANG ; Fei WANG ; Xue-jiao WEI ; Zhu-guo WANG ; Jun LI ; Zhong-dong HU
Acta Pharmaceutica Sinica 2024;59(4):957-964
3ʹ-Hydroxy-4ʹ-methoxy-2-hydroxy-5-bromochalcone (hereinafter referred to as C13) is a novel chalcone derivative obtained in the process of structural modification of DHMMF, the antitumor active compound of
9.Comparsion of bone setting technique combined with percutaneous vertebroplasty and percutaneous kyphoplasty for the treatment of osteoporotic vertebral compression fractures
Wen-Chao LI ; Peng-Fei YU ; Guang-Ye ZHU ; Hong GUO ; Ya-Hao LI ; Xian-Da ZHANG ; Chao LI ; Hong JIANG ; Hong-Wei LI
China Journal of Orthopaedics and Traumatology 2024;37(6):546-552
Objective To explore clinical efficacy of osteoplasty combined with percutaneous vertebroplasty(PVP)and percutaneous kyphoplasty(PKP)alone in treating osteoporosis vertebral compression fractures(OVCFs).Methods The clini-cal data of 80 patients with single-level OVCFs treated from January 2021 to June 2022 were retrospectively analyzed,and were divided into treatment group and control group according to different surgical methods,40 patients in each group.In treatment group,there were 24 males and 16 females,aged from 60 to 83 years old with an average of(70.43±7.31)years old;bone min-eral density ranged from-3.30 to-2.50 SD with an average of(-2.84±0.24)SD;1 patient with T10,4 patients with T11,11 pa-tients with T12,7 patients with L1,7 patients with L2,5 patients with L3,3 patients with L4,2 patients with L5;bone setting tech-nique combined with PVP were performed.In control group,there were 27 males and 13 females,aged from 60 to 82 years old with an average of(68.98±6.94)years old;bone mineral density ranged from-3.40 to-2.50 SD with an average of(-2.76±0.23)SD;2 patients with T10,3 patients with T11,13 patients with T12,11 patients with L1,5 patients with L2,3 patients with L3,2 patients with L4,1 patient with L5;simple PKP were peformed.Visual analogue scale(VAS)and lumbar Oswestry disability in-dex(ODI)were compared between two groups before operation,3 days,3 and 12 months after operation.The changes of local kyphotic angle,vertebral wedge angle and vertebral anterior margin height ratio were compared between two groups before op-eration,3 days and 12 months after operation.Results All patients were successfully completed operation.Treatment group were followed up from 13 to 22 months with an average of(16.82±2.14)months,and control group were followed up from 13 to 23 months with an average of(16.45±2.56)months.Three patients were occurred bone cement leakage in treatment group,while 1 patient were occurred bone cement leakage and 1 patient occurred sensory disturbance of lower limb skin in control group;there were no significant difference in complications between two groups(P>0.05).There were no significant difference in preoperative VAS and ODI between two groups(P>0.05).At 3 days after operation,VAS of treatment group 3.68±0.62 was significantly higher than that of control group 4.00±0.72(P<0.05).There were no significant difference in VAS and ODI be-tween two groups at 3 and 12 months after operation(P>0.05).There were no significant difference in local kyphotic angle,vertebral wedge angle and vertebral anterior margin height between two groups at 3 days and 12 months after operation(P>0.05).Conclusion Compared with PKP,bone setting manipulation combined with PVP for the treatment of OVCFs has advan-tages in early postoperative pain relief.In terms of vertebral height recovery,bone setting manipulation combined with PVP and PKP alone have similar clinical effects.
10.Evaluation and optimization of metagenomic sequencing platforms for bloodstream infection samples
Xin PENG ; Hang FAN ; Meng-Nan CUI ; Lei LIN ; Guang-Qian PEI ; Yun-Fei WANG ; Xiu-Juan ZUO ; Xiao-Feng FANG ; Yan GUO ; Yu-Jun CUI
Chinese Journal of Zoonoses 2024;40(10):928-934
This study was aimed at comparing performance differences among three metagenomic sequencing platforms,MGISEQ-2000,Illumina NextSeq 2000,and Ion GeneStudio S5 Plus,to optimize the sequencing process for trace samples.The three sequencing platforms were used to perform high-throughput sequencing on DNA standards and simulated samples.Through analysis of the quality of raw data and microbial detection capabilities,systematic differences among platforms were compared.The sequencing results were optimized for trace samples by incorporation of exogenous nucleic acids during the li-brary preparation process.In terms of data output per batch and base quality,MGISEQ-2000 surpassed the other two plat-forms.Illumina NextSeq 2000 had the lowest proportion of duplicate reads,whereas Ion GeneStudio S5 Plus had the highest proportion,and significant differences were observed across platforms(P<0.001).In sequencing uniformity,MGISEQ-2000 and Illumina NextSeq 2000 were superior to Ion GeneStudio S5 Plus.MGISEQ-2000 provided a substantial advantage in microbial detection capability(P<0.001),but the advantage diminished with decreasing bacterial fluid concentration.Ion GeneStudio S5 Plus had the shortest duration for single-batch sequencing.Moreo-ver,for trace samples with DNA content ≤0.05 ng,the experi-mental group(with added exogenous nucleic acids)achieved a higher number of reads than the control group(without exogenous nucleic acids),with a 11.09±8.03 fold increase.In conclu-sion,the different sequencing platforms each had advantages and disadvantages,thus allowing researchers to choose the appro-priate platform according to specific needs.Furthermore,the addition of exogenous nucleic acids improved the microorganism detection efficiency,and provided better support for subsequent diagnosis and evaluation of results.

Result Analysis
Print
Save
E-mail