1.A case-crossover study on the impact of air pollution on the number of pediatric respiratory outpatient and emergency visits in a hospital in Shanghai
Peihua FU ; Julong LI ; Jing ZHANG ; Qiaozhen ZHANG ; Huimin JIN ; Min SONG ; Yanhan ZHANG ; Zhen GU
Journal of Public Health and Preventive Medicine 2024;35(1):29-33
Objective To investigate the correlation between the concentration of air pollutants (PM10, SO2, NO2) and the number of outpatient and emergency visits for pediatric respiratory diseases in a general hospital in Shanghai. Methods Data including pediatric respiratory disease outpatient and emergency visits in a hospital in Pudong New Area of Shanghai from May 1, 2013 to March 20, 2022 were collected. Daily concentration of air pollutants including PM10, SO2 and NO2 and meteorological data in Pudong New Area during the same period were collected. A case-crossover study with distributed lag non-linear model was conducted to explore the correlation between air pollutants (PM10, SO2, NO2) and the number of outpatient and emergency visits for pediatric respiratory diseases. Results The concentrations of PM10, SO2 and NO2 were positively with the number of outpatient and emergency visits for pediatric respiratory diseases. The strongest cumulative effect was observed on six days lag (Lag0-5) for PM10. For a 10 μg/m3 increase of the concentrations of PM10, the corresponding increase of cumulative pediatric respiratory disease outpatients was 1.10% (95%CI:0.97%, 1.23%) in Lag0-5. The strongest cumulative effect was observed on eight days lag (Lag0-7) for SO2 and NO2. For a 10 μg /m3 increase of the concentrations of SO2 and NO2, the corresponding increase of cumulative pediatric respiratory disease outpatients was 5.64% (95%CI:5.16%, 6.13%) and 5.41% (95%CI:5.15%, 5.66%) in Lag 0-7, respectively. The association of PM10 and SO2 with the number of pediatric respiratory disease visits in males was significantly stronger than that in females. The impact of PM10 on the number of pediatric respiratory disease visits in children aged 0-6 was higher than that in children aged 7-14, while the impact of SO2 and NO2 on the number of pediatric respiratory disease visits in children aged 7-14 was higher than that in children aged 0-6. Conclusion The concentration of ambient PM10, SO2, and NO2 is positively correlated with outpatient and emergency visits for pediatric respiratory diseases, with obvious lag and cumulative effect. Boys and children aged 0-6 are more susceptible to the hazard of air pollution.
2.Experimental analysis of clinical applicability of individualized customized materials
Yun WANG ; Peihua GU ; Jiehua WANG ; Jinlan GONG ; Li CHEN ; Yanshu MU ; Xiaoxiao ZHANG ; Chang GUAN ; Lu WANG
Chinese Journal of Radiological Health 2022;31(5):601-605
Objective To study the feasibility of clinical application of an individualized customized material. Methods Five batches of individualized customized materials were randomly selected, from which 10 cm × 11 cm samples were intercepted for experimental analysis. Among them, 10 cm × 10 cm materials were selected to perform dosimetric analysis and HU change analysis before and after irradiation with a radiotherapy dose for breast cancer of 50 Gy as the irradiation basis. The center Point 1 on the lower surface of the individualized material and the center Point 2 of the solid water volume were selected for dosimetric analysis before and after the sample is irradiated. After reaching a sufficient amount of irradiation, the 1 cm × 10 cm materials intercepted in the center position and the remaining 1 cm × 10 cm materials after the first sampling were sent to the material science laboratory for analysis of physical properties of density, viscosity, hardness, and tear strength. Results In the comparative analysis of HU values before and after exposure, after receiving 50 Gy dose irradiation, the difference rate of HU value was 5.252%, which was close to the expected 5% difference rate in clinical medicine. In the dosimetric analysis of Point 1 and Point 2, the dose in the irradiated samples was significantly higher than that in the unirradiated samples; the dose in Point 1 increased by 3.742%, and the dose in Point 2 increased by 2.039%. Before and after irradiation, except for the physical density which showed a significant difference, there was no significant difference in viscosity, hardness, and tear strength. Conclusion The individualized customized material can meet the requirements of routine clinical medicine.
3.Impact of statistical uncertainty on esophagus cancer plan for dose to water and dose to medium
Yun WANG ; Peihua GU ; Jiehua WANG ; Can CAO ; Qinghao LI ; Li CHEN ; Xiaoxiao ZHANG ; Lu WANG
Chinese Journal of Radiological Health 2021;30(3):295-302
Objective To study the dosimetry effect of Dw and Dm middle and lower esophageal cancer in Monaco treatment planning system (TPS). Methods 30 patients with T3N0M0StageⅡa middle and lower esophageal cancer were selected for experiment. For each patient, optimize the plan using dose to water (Dw) and dose to medium (Dm) dose calculation mode, then rescale prescription dose to 95% volume of PTV. Compare the difference in the two mode, conformity index (CI), Homogeneity index (HI), Mean dose (Dmean), Minimum dose (Dmin), Maximum dose (D2), Dose to Organ at risk (OAR), MU, Optimization time, photon usage, and QA results of MatriXX and Arc Check. Use SPSS for multivariate analysis. Results In the dose evaluation of the middle and lower esophageal cancer cases under different dose calculation methods, the spinal cord, trachea, V20 of the whole lung, and D2 of the liver have significant dosimetric differences, the dose value, the sequential dose results were compared as (37.92 ± 1.11)/(35.85 ± 1.08), (59.91 ± 1.43)/(60.25 ± 0.98), (22.52 ± 1.75)/(21.38 ± 2.01), (42.89 ± 0.52)/(41.73 ± 0.58). In the comparison of dose cloud distribution, the difference is mainly located in the cavity and the inner wall of the lung in the target area, the dose in the target cavity in the Dw group is higher than that in the Dm group. The dose in the inner and outer walls of the lung cavity in the Dw group are slightly adducted than that in the Dm group, especially in the central area.Dose QA of MartiXX (3%-3 mm) and Arc Check (2%-2 mm) with different dose calculation methods of 60 plans of 30 cases have all passed clinical requirements. Dm Group is better than Dw group. Conclusion It is recommended to use Dm dose calculation method for Monaco 5.11 TPS in the condition of treatment planning for middle and lower esophageal cancer.
4.The effect of cotton pad thickness plus compression bandage on radiation doses to irradiated keloid dermoplasty
Yun WANG ; Hui YAO ; Peihua GU ; Jiehua WANG
Chinese Journal of Radiological Medicine and Protection 2018;38(1):56-58
Objective To investigate the effect of cotton pad plus compression bandage on radiation doses from radiation therapy of keloid dermoplasty.Methods Radiation doses from electron beams with different energies were measured using Siemens Primus-H accelerator,PTW-Quickcheck and 1-10 layers of dry,wet,blood cotton pad,respectively.Results The cotton pad could be used to prevent errhysis after radiation therapy of keloids.When 5 or more layers of cotton pad,about 2 cm,were used and errhysis still occur red,9 MeV electron beam should be used for the purpose of achieving the desirable dose and treatment result without occurrence of errhysis.Conclusions In clinical practice,to achieve the desirable dose for keloid treatment,electron beam energy should be adapted according to the errhysis situation.It is recommended to provide the measured data to determine the prescribed dose.
5.Correlation Research of Plasma Glucose, Blood Pressure Level and TCM Syndromes in Shanghai Community Residents
Dong LI ; Huayu HE ; Zhan GU ; Huimin ZHU ; Xiuhua SUN ; Haoqing LING ; Peihua ZHANG ; Jianying WANG ; Baocheng LIU ; Lei ZHANG
World Science and Technology-Modernization of Traditional Chinese Medicine 2018;20(9):1705-1712
Objectives: The purpose of this study is to understand the relationships among plasma glucose, blood pressure level and Traditional Chinese Medicine (TCM) syndromes in Shanghai community residents, and provide a theoretical basis for the prevention of community chronic disease based on TCM syndrome differentiation.Methods: Residents above35 years old will attend the Type 2 Diabetes Mellitus (T2 DM) risk assessment at Community Health Center. By distributing questionnaires and performing glucose testing, we screened the residents at high risk of T2 DM, and conducted a physical examination of them. Further, a body constitution questionnaire was required to be completed by the residents. Results: In total, 933 residents were screened. The plasma glucose and blood pressure levels related to age, waist circumference, hip circumference, body mass index (BMI) and waist-to-height ratio (WHtR) . Residents with increasing blood pressure have an increased risk of T2 DM (P < 0.01) . Total 529 questionnaires were completed, and 129 subjects (24.4%) have single TCM syndromes, 75 subjects (14.2%) have at least two TCM syndromes and 325 subjects (61.4%) have no TCM syndromes. Conclusion: Plasma glucose and blood pressure are associated and interacted with several physical indexes. TCM syndromes distribution was found no significant change among subjects with different plasma glucose and blood pressure.
6.The radiology information system and picture archiving and communication system integration method based on HL7 standard
China Medical Equipment 2016;13(4):50-53,54
Objective:To analyse the dataflow and clinical flow in Suzhou municipal hospital radiology information system and picture archiving system, presents a set of system integration messages, and describes the effect of each message for the communication. Methods: Follow the framework of IHE and HL7 protocol, the paper uses standard messages to integrate two different systems for patient and study status communication. The integration can meet clinical users’ requirements.Results: Based on many years practice, the integration reached designed target.Conclusion: With further research on standard, the seamless system integration between different systems can help customer to make full use of each system and save more cost in system purchase.
7.The value of multi-modal MRI in diagnosis of breast cancer in the dense breasts
Qian CHEN ; Yuying SHEN ; Shuangqing CHEN ; Qing CAI ; Peihua GU ; Chuanxiao XU ; Mingmin TONG
Journal of Practical Radiology 2016;32(10):1535-1538
Objective To explore the multi-modal MRI characteristics of breast cancers in dense breasts.Methods 120 patients with breast cancer shown on mammography underwent breast MRI,which were solitary and confirmed by pathological examination. According to the BI-RADS classification of breast,the 120 cases were divided into two groups including dense type breast and non-dense type one.The differences in morphological features,ADC values (b=1 000 s/mm2 )and time-signal intensity curve (TIC)of the lesions between two groups were analyzed and compared.Statistical analysis was performed using SPSS1 6.0.Results The breast cancers in dense breast were vulnerable to have a spiculated margin (44/68 in the dense breast group vs.1 6/52 in the non-dense breast group,P =0.000).The size of the lesion in dense breast (1.83 ±0.98)cm was bigger than that in non-dense breast (1.40±0.46)cm (P =0.005).The non-mass-like enhancement of the lesion in dense breast was much more than that in non-dense breast (P =0.000).In addition,the average ADC values of the lesion in dense breast (0.89±0.12)×10 -3 mm2/s were lower than in non-dense breast (0.95±0.10)×10 -3 mm2/s(P =0.01 6).Conclusion The breast cancer in the dense breast has different MRI findings in comparison with non-dense breast.
8.A Monte Carlo simulation method for reconstruction of accelerator based on verified 6 MV X-ray phase-space and energy spectrum information
Yun WANG ; Hui YAO ; Jiehua WANG ; Peihua GU
Chinese Journal of Radiation Oncology 2016;25(8):847-850
Objective To establish a novel Monte Carlo simulation method for reconstruction of medical accelerator model and X?ray energy spectrum based on IAEA Varian 6 MV X?ray phase?space file and photon energy spectrum of the target accelerator. Methods The verified 6 MV X?ray phase?space files were preprocessed to elevate the energy of each particle. Particles were saved in different Phase?Space?Let ( PSL) files according to their position and energy, yielding an initial photon energy spectrum for Monte Carlo simulation of accelerator under an initial target energy. The initial photon energy spectrum was fit to a photon energy spectrum of an accelerator ( Elekta Precise 10 MV X?ray accelerator) under an unknown target energy to yield a fitting coefficient, which was the weight of each PSL. Finally, an accelerator model under an unknown target energy was reconstructed using the initial PSL files and the weight information. The percentage depth dose ( PDD) distribution was calculated in different square open fields. The effectiveness of this method was verified using one dimensional gamma passing rate. Results The peak position and overall distribution of the reconstructed 10 MV photon energy spectrum were in accordance with those of the verified 10 MV photon energy spectrum. The PDD calculated from the reconstructed 10 MV accelerator model agreed well with the measured PDD. The one?dimensional gamma passing rate was above 96%( 1%/1 mm, threshold=0%) . Conclusion The Monte Carlo reconstruction method proposed in this study is reliable, accurate, and effective.
9.Clinical evaluation of modified transthecal digital block and traditional dorsal digital block techniques for hand injury of adults in emergency
Ye LU ; Wenqi GU ; Peihua CAI ; Yanfeng LI ; Yulin ZHAN ; Yimin CHAI
Chinese Journal of Tissue Engineering Research 2015;(15):2356-2360
BACKGROUND:Dorsal digital block refers to the commonly used anesthesia for adults in smal or moderate hand injury surgeries, but in recent years, modified transthecal digital block technique is gradualy respected, which is favored with a rapid and good effect and fewer complications.
OBJECTIVE:To evaluate the clinical anesthetic outcomes of modified transthecal digital block and traditional dorsal digital block technique for the treatment of hand injury of adults in emergency by a prospective randomized controled study.
METHODS:Totaly 60 adult patients with hand injury were enroled and divided into two groups of modified transthecal digital block and traditional dorsal digital block randomly. Blocks were performed by one single surgeon. The operation time, local anesthetic dose, onset time of anesthesia, duration of anesthesia, success rate of anesthesia, visual analogue scale scores and complications were recorded.
RESULTS AND CONCLUSION:The anesthesia effects in the two groups were acceptable. There was no significant difference in the onset time of anesthesia, duration of anesthesia, success rate of anesthesia and complications between the two groups (P > 0.05). The operation time of anesthesia, local anesthetic dose, and visual analogue scale scores were significantly different between the two groups (P< 0.05). Modified transthecal digital block is more convenient and has less pain than the traditional root digital block, which is a safe and reliable anesthetic technique.
10.Activation of AMP-activated protein kinase is involved in doxorubicin-induced anti-breast cancer cell proliferation
Jinhua GU ; Ling CHEN ; Peihua LU ; Minbin CHEN
Cancer Research and Clinic 2012;24(4):235-238
Objective To investigate the mechanism of anti-breast cancer cell proliferation induced by doxorubicin (DOX).Methods AMP-Activated Protein Kinase (AMPK) activator AICAR,AMPK siRNA,AMPK inhibitor compound C(AMPKi) and doxorubicin treated MCF-7 cells at different time points; AMPK,acetyl CoA carboxylase (ACC),p38 activation were detected by Western blot.MTT was used as cell viability assay. Results Doxorubicin-induced activation of AMPK, AMPK agonist (AICAR)or in combination with doxorubicin activated AMPK and increased MCF-7 cell proliferation rate [the difference of cell viability between group AICAR+DOX(17.7±1.6 ) % and group DOX(71.4±1.8 ) % was significant(P<0.001)].After AMPKi or AMPK siRNA and doxorubicin combined administration, P-AMPK and P-ACC expression was significantly decreased,the level of p38 was not affected,and MCF-7 cell proliferation inhibition rate decreased [the cell viability of group AMPKi+DOX(72.7±1.8 ) % vs group DOX(96.3±1.7 ) %,P<0.001 ;group AMPK siRNA +DOX( 76.9±2.2 ) % vs group scramble siRNA+DOX(95.9±1.8) %,P<0.001].Conclusion AMPK is involved in doxorubicin-induced anti-breast cancer cell proliferation.


Result Analysis
Print
Save
E-mail