1.Methacrylated dermal extracellular matrix hydrogel promotes repair of abdominal wall defects
Zhongyu LIU ; Wenya LI ; Yonghong FAN ; Shuang LYU ; Juan PEI ; Yaqin CHEN ; Beiyu LIU ; Hongyu SUN
Chinese Journal of Tissue Engineering Research 2025;29(10):2074-2082
BACKGROUND:Synthetic polymers,such as polypropylene and polyester,used for the treatment of abdominal wall defects not only lack biodegradability and bioactivity but also fail to meet the demands of complex and irregular wounds.Therefore,finding bioactive materials with low immunogenicity and good histocompatibility has become a hot spot in the repair of abdominal wall defects. OBJECTIVE:To prepare methacryloyl modified dermal extracellular matrix hydrogel and explore its potential application in abdominal wall defect. METHODS:(1)The porcine dermis was acellular with 0.25%trypsin and 1%Triton X-100 in turn to obtain the dermal extracellular matrix.After pepsin digestion and methacrylic anhydride modification,the methacrylated dermal extracellular matrix hydrogel was formed by photocrosslinking.The microscopic morphology of the hydrogel was observed by scanning electron microscope,and its rheological properties,swelling properties and other physical and chemical properties were tested.(2)Mice fibroblasts(L929)were inoculated into methacrylated dermal extracellular matrix hydrogel to detect the cell compatibility.(3)Totally 12 SD rats were randomly divided into two groups(n=6)to create abdominal wall defect model with peritoneum preserved.The defect site of the polypropylene group was filled with polypropylene material,and the hydrogel group was filled with methacrylated dermal extracellular matrix hydrogel.The wound skin of both groups was covered with polypropylene material.The wound healing was observed and histological analysis was carried out. RESULTS AND CONCLUSION:(1)Enzymatic hydrolysis had a good decellularization effect on porcine dermis after decellularization,and the original glycosaminoglycans and collagen were well retained.Scanning electron microscope observation revealed that the dermal extracellular matrix hydrogel presented loose and porous structure.The aperture was between 70 and 120 μm.The swelling ratio was(16.88±3.24)%and the water absorption was(94.24±1.11)%.The rheological property test showed that the methacrylated dermal extracellular matrix hydrogel was stable and had shear thinning characteristics,with injectability.(2)CCK-8 assay and live/dead staining showed that methacrylated dermal extracellular matrix hydrogel had good cell compatibility.(3)The results of animal experiments showed that the skin wound healing rate of the experimental group was higher than that of the control group at 7,10,and 14 days after operation(P<0.05).Hematoxylin-eosin and Masson staining of skin and muscle tissue exhibited that compared with the polypropylene group,the skin wound epithelialization,hair follicle formation,collagen fiber arrangement,and neovascularization were better in the hydrogel group 14 days after surgery.The skin wound new tissue structure was similar to the normal tissue at 28 days after surgery,and scar hyperplasia was less.A small amount of muscle regeneration was observed on day 28 after operation.(4)The results show that the methacrylated dermal extracellular matrix hydrogel can promote wound skin healing and muscle tissue regeneration in rats with abdominal wall defect.
2.Clinical Efficacy of Tangning Tongluo Tablets for Nonproliferative Diabetic Retinopathy
Fuwen ZHANG ; Junguo DUAN ; Wen XIA ; Tiantian SUN ; Yuheng SHI ; Shicui MEI ; Xiangxia LUO ; Xing LI ; Yujie PAN ; Yong DENG ; Chuanlian RAN ; Hao CHEN ; Li PEI ; Shuyu YANG
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(3):132-139
ObjectiveTo observe the clinical efficacy and safety of Tangning Tongluo tablets in the treatment of nonproliferative diabetic retinopathy (DR). MethodsFourteen research centers participated in this study, which spanned a time interval from September 2021 to May 2023. A total of 240 patients with nonproliferative DR were included and randomly assigned into an observation group (120 cases) and a control group (120 cases). The observation group was treated with Tangning Tongluo tablets, and the control group with calcium dobesilate capsules. Both groups were treated for 24 consecutive weeks. The vision, DR progression rate, retinal microhemangioma, hemorrhage area, exudation area, glycosylated hemoglobin (HbA1c) level, and TCM syndrome score were assessed before and after treatment, and the safety was observed. ResultsThe vision changed in both groups after treatment (P<0.05), and the observation group showed higher best corrected visual acuity (BCVA) than the control group (P<0.05). The DR progression was slow with similar rates in the two groups. The fundus hemorrhage area and exudation area did not change significantly after treatment in both groups, while the observation group outperformed the control group in reducing the fundus hemorrhage area and exudation area. There was no significant difference in the number of microhemangiomas between the two groups before treatment. After treatment, the number of microhemangiomas decreased in both the observation group (Z=-1.437, P<0.05) and the control group (Z=-2.238, P<0.05), and it showed no significant difference between the two groups. As the treatment time prolonged, the number of microhemangiomas gradually decreased in both groups. There was no significant difference in the HbA1c level between the two groups before treatment. After treatment, the decline in the HbA1c level showed no significant difference between the two groups. The TCM syndrome score did not have a statistically significant difference between the two groups before treatment. After treatment, neither the TCM syndrome score nor the response rate had significant difference between the two groups. With the extension of the treatment time, both groups showed amelioration of TCM syndrome compared with the baseline. ConclusionTangning Tongluo tablets are safe and effective in the treatment of nonproliferative DR, being capable of improving vision and reducing hemorrhage and exudation in the fundus.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Three 2,3-diketoquinoxaline alkaloids with hepatoprotective activity from Heterosmilax yunnanensis
Rong-rong DU ; Xin-yi GUO ; Wen-jie QIN ; Hua SUN ; Xiu-mei DUAN ; Xiang YUAN ; Ya-nan YANG ; Kun LI ; Pei-cheng ZHANG
Acta Pharmaceutica Sinica 2024;59(2):413-417
Three 2,3-diketoquinoxaline alkaloids were isolated from
9.Phenotypic evaluation of Ttc37 knockout mouse as type Ⅰ tricho-hepato-enteric syndrome model
Ming-Ya LI ; Xue-Lin WANG ; Ye WEI ; Pei-Hong YANG ; Lei SUN
Fudan University Journal of Medical Sciences 2024;51(2):249-256
Objective To establish a mouse model of type Ⅰ tricho-hepato-enteric syndrome(THES)induced by Ttc37 deficiency.Methods Ttc37 flox strain was established by site-specifically inserted loxP sites into Ttc37 gene via CRISPR/CAS9 technology.Ubiquitously expressed CAG-Cre was introduced for all-tissue removal of Ttc37 in Ttc37flox/flox;CAG-Cre mice.The knock-out effect was confirmed by fluorescence quantitative PCR and Western blot.Phenotypic evaluations were conducted in 8-week-old mice including hematoxylin-eosin staining of skin,spleen,liver,bladder,and gastrointestinal tract(GI),serum enzyme activity assay of aspartate aminotransferase(AST)and alanine aminotransferase(ALT),measurement of serum hemoglobin level,and ELISA for IgG and IgM level upon antigen immunization.Results Similar to type Ⅰ THES patients,Ttc37flox/flox;CAG-Cre mice exhibited impaired development of hair shaft,epidermis,B cell and eyes,while liver,GI,bladder and serum hemoglobin level seemed normal under unstressed condition.Conclusion A novel mouse model of typeⅠ THES was constructed successfully,which was applicable for pathological study.
10.Desalination effect on FⅧ components: a compartive study among 5 desalination methods
Renjun PEI ; Xi DU ; Pan SUN ; Xiaoyue LI ; Peng JIANG ; Changqing LI ; Fangzhao LIN ; Haijun CAO
Chinese Journal of Blood Transfusion 2024;37(3):304-311
【Objective】 To compare the desalination effects of five desalination methods and their effects on the components for human coagulation factor Ⅷ(FⅧ), and provide reference for selection of protein desalination methods. 【Methods】 Sephadex G-25 Medium gel, Fractogel EMD BioSEC gel, ultrafiltration, room temperature dialysis and 4℃ dialysis were used to desalt human FⅧ. The desalination effect was evaluated by the removal rate of Na +, citrate ion and glycine. FⅧ protein recovery, FⅧ activity (FⅧ∶C), VWF antigen (VWF∶Ag), VWF activity(VWF∶Ac), VWF polymers and SDS-PAGE analysis before and after desalination were compared to evaluate the effect of desalination on FⅧ components. 【Results】 In terms of desalination effect, the removal rate of Na+ was the lowest in ultrafiltration desalination, while that of Fractogel EMD BioSEC gel was the highest [(97.90±0.06) % vs (99.82±0.07) %]. Except that there was no statistical significance between Sephadex G-25 Medium gel desalination and Fractogel EMD BioSEC gel desalination (P=0.90), the removal rates of the other four methods were statistically significant. The removal rate of glycine was the lowest in ultrafiltration desalination, wihle that of Fractogel EMD BioSEC gel desalination was the highest [(95.78±0.42) % vs (99.81±0.08) %]. Significant difference in glycine removal was noticed in ultrafiltration desalination, but not among the other four desalination methods. There was no significant difference in the removal rate of citrate ions among the five methods (P=0.85). For the effect of FⅧ components, FⅧ∶C, VWF∶Ag, VWF∶Ac and protein recovery rates of ultrafiltration desalination were the highest, with (18.34±1.99) IU/mL, (11.81±0.33) IU/mL, (12.26±0.58) IU/mL and (97.13±1.37) %, respectively. There was no significant change in VWF∶Ac/VWF∶Ag before and after desalination by the five methods. SDS-PAGE and VWF polymer analysis showed that different desalination methods had no significant impact on protein composition. 【Conclusion】 Although different desalination methods had no significant effect on the composition of FⅧ protein, the desalination effect was different. Moreover, different desalination methods had significant effects on protein recovery, FⅧ∶C, VWF∶Ag and VWF∶Ac. The selection of desalination methods should be more considered during protein processing,

Result Analysis
Print
Save
E-mail