1.Effects of honey-processed Astragalus on energy metabolism and polarization of RAW264.7 cells
Hong-chang LI ; Ke PEI ; Wang-yang XIE ; Xiang-long MENG ; Zi-han YU ; Wen-ling LI ; Hao CAI
Acta Pharmaceutica Sinica 2025;60(2):459-470
In this study, RAW264.7 cells were employed to investigate the effects of honey-processed
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7. Inhibition of HSP70 release by geniposide improves angiogenesis in moist heat arthralgia spasm syndrome collagen induced arthritis rats
Yin SHU ; Pei-Rong GAN ; Yan WANG ; Yan-Hong BU ; Hong WU
Chinese Pharmacological Bulletin 2024;40(2):324-334
Aim To investigate the relation between the effect of geniposide (GE) in improving angiogenesis in arthralgia spasm syndrome collagen induced arthritis (CIA) rats and the modulation of heat shock proteins 70 (HSP70) release. Methods A CIA model was constructed by multiple intradermal injections of complete Freund's adjuvant (CFA) and an equal volume mixture of chicken type II collagen (CCII) into the dorsal and caudal root regions of rats, on the basis of which a rheumatic fever stimulus was given to build up a moist heat arthralgia spasm syndrome in CIA rats. After successful modeling, the groups were randomly grouped, and the administered groups were gavaged with GE (60, 120 mg · kg
8.Exploration of the Acupoint Selection Rules of Acupuncture for the Treatment of Tic Disorders in Children Based on Data Mining Techniques
Shan-Hong WU ; Zi-Han GONG ; Yan WANG ; Yang GAO ; Yi-Ming YUAN ; Ming-Yue ZHAO ; Zi-Wei ZHANG ; Tian-Yi LI ; Fei PEI
Journal of Guangzhou University of Traditional Chinese Medicine 2024;41(4):1083-1090
Objective To analyze the acupoint selection rules of acupuncture for the treatment of tic disorders in children based on data mining techniques.Methods A computerized search was conducted for the clinical research literature on acupuncture treatment of tic disorders in children included in the CNKI,Wanfang,VIP,SinoMed,and PubMed databases from January 1992 to December 2022.A database was established by Excel 2019 to count the commonly used treatment methods and analyze the high-frequency application methods acupuncture(high-frequency acupoints,channel entry of acupoints,acupoint association rules,and acupoint clustering),auricular point seed-pressing(high-frequency auricular points,and acupoint association rules),and the high frequency division of cluster needling of scalp point.Results A total of 190 valid literature articles were included,involving 270 acupuncture prescriptions;among them,184 acupoints were counted in the acupuncture method,with a total application frequency of 1 906 times,and the high-frequency application of the acupoints in descending order were Baihui(DU20),Taichong(LR3),Fengchi(GB20),Hegu(LI4),Sanyinjiao(SP6),Neiguan(PC6),Shenmen(HT7),Zusanli(ST36),Yintang(EX-HN3),Sishencong(EX-HN1);and the high-frequency meridians were governor vessol,foot taiyang stomach meridian,foot taiyang stomach meridian,foot shaoyang gallbladder meridian,hand taiyang large intestine meridian,foot taiyang bladder meridian,foot jueyin gallbladder meridian;three sets of strong association rules and five clusters of acupoints were analyzed by SPSS modeler 18.0 and IBM SPSS Statistics 26.0 software.There were 29 acupoints of auricular point seed-pressing,application total frequency was 206 times,high-frequency application of auricular points in descending order of Shenmen(HT7),liver,heart,subcortex,kidney;four groups of acupoint strong association rules were obtained through the analysis of SPSS modeler 18.0 software.A total of 14 zones were involved in the application of cephalic acupoint plexus zoning,of which the high-frequency zones were parietal anterior temporal diagonal,parietal parietal 1,and chorea tremor control zone.Conclusion Acupuncture treatment of tic disorders in children,according to its pathogenesis(liver hyperactivity,kidney depletion,spleen deficiency,phlegm disturbance,etc.)and tic site,select acupoints compatibility,and mostly choose yang meridian acupoints,which is related to the nature and treatment characteristics of wind pathogen.Children's tic disorders are closely related to emotional disorders,therefore acupuncture and auricular acupoints all emphasize the method of soothing the liver and clearing the heart,and regulating the emotional state.Cluster needling of scalp point mostly used parietal temporal anterior oblique line,parietal 1 line,and dance tremor control area for the treatment of tic disorders.For children,auricular point seed-pressing and cluster needling of scalp point has the minimun of pain,the effect of treatment is long,and it is not easy to have dangerous situations such as bent needle,broken needle and so on.
9.Phenotypic evaluation of Ttc37 knockout mouse as type Ⅰ tricho-hepato-enteric syndrome model
Ming-Ya LI ; Xue-Lin WANG ; Ye WEI ; Pei-Hong YANG ; Lei SUN
Fudan University Journal of Medical Sciences 2024;51(2):249-256
Objective To establish a mouse model of type Ⅰ tricho-hepato-enteric syndrome(THES)induced by Ttc37 deficiency.Methods Ttc37 flox strain was established by site-specifically inserted loxP sites into Ttc37 gene via CRISPR/CAS9 technology.Ubiquitously expressed CAG-Cre was introduced for all-tissue removal of Ttc37 in Ttc37flox/flox;CAG-Cre mice.The knock-out effect was confirmed by fluorescence quantitative PCR and Western blot.Phenotypic evaluations were conducted in 8-week-old mice including hematoxylin-eosin staining of skin,spleen,liver,bladder,and gastrointestinal tract(GI),serum enzyme activity assay of aspartate aminotransferase(AST)and alanine aminotransferase(ALT),measurement of serum hemoglobin level,and ELISA for IgG and IgM level upon antigen immunization.Results Similar to type Ⅰ THES patients,Ttc37flox/flox;CAG-Cre mice exhibited impaired development of hair shaft,epidermis,B cell and eyes,while liver,GI,bladder and serum hemoglobin level seemed normal under unstressed condition.Conclusion A novel mouse model of typeⅠ THES was constructed successfully,which was applicable for pathological study.
10.A Rapid Non-invasive Method for Skin Tumor Tissue Early Detection Based on Bioimpedance Spectroscopy
Jun-Wen PENG ; Song-Pei HU ; Zhi-Yang HONG ; Li-Li WANG ; Kai LIU ; Jia-Feng YAO
Progress in Biochemistry and Biophysics 2024;51(5):1161-1173
ObjectiveIn recent years, with the intensification of environmental issues and the depletion of ozone layer, incidence of skin tumors has also significantly increased, becoming one of the major threats to people’s lives and health. However, due to factors such as high concealment in the early stage of skin tumors, unclear symptoms, and large human skin area, most cases are detected in the middle to late stage. Early detection plays a crucial role in postoperative survival of skin tumors, which can significantly improve the treatment and survival rates of patients. We proposed a rapid non-invasive electrical impedance detection method for early screening of skin tumors based on bioimpedance spectroscopy (BIS) technology. MethodsFirstly, we have established a complete skin stratification model, including stratum corneum, epidermis, dermis, and subcutaneous tissue. And the numerical analysis method was used to investigate the effect of dehydrated and dry skin stratum corneum on contact impedance in BIS measurement. Secondly, differentiation effect of different diameter skin tumor tissues was studied using a skin model after removing the stratum corneum. Then, in order to demonstrate that BIS technology can be used for detecting the microinvasion stage of skin tumors, we conducted a simulation study on the differentiation effect of skin tumors under different infiltration depths. Finally, in order to verify that the designed BIS detection system can distinguish between tumor microinvasion periods, we conducted tumor invasion experiments using hydrogel treated pig skin tissue. ResultsThe simulation results show that a dry and high impedance stratum corneum will bring about huge contact impedance, which will lead to larger measurement errors and affect the accuracy of measurement results. We extracted the core evaluation parameter of relaxed imaginary impedance (Zimag-relax) from the simulation results of the skin tumor model. When the tumor radius (Rtumor) and invasion depth (h)>1.5 mm, the designed BIS detection system can distinguish between tumor tissue and normal tissue. At the same time, in order to evaluate the degree of canceration in skin tissue, the degree of tissue lesion (εworse) is defined by the relaxed imaginary impedance (Zimag-relax) of normal and tumor tissue (εworse is the percentage change in virtual impedance of tumor tissue relative to that of normal tissue), and we fitted a Depth-Zimag-relax curve using relaxation imaginary impedance data at different infiltration depths, which can be applied to quickly determine the infiltration depth of skin tumors after being supplemented with a large amount of clinical data in the future. The experimental results proved that when εworse=0.492 0, BIS could identify microinvasive tumor tissue, and the fitting curve correction coefficient of determination was 0.946 8, with good fitting effect. The simulation using pig skin tissue correlated the results of real human skin simulation with the experimental results of pig skin tissue, proving the reliability of this study, and laying the foundation for further clinical research in the future. ConclusionOur proposed BIS method has the advantages of fast, real-time, and non-invasive detection, as well as high sensitivity to skin tumors, which can be identified during the stage of tumor microinvasion.

Result Analysis
Print
Save
E-mail