1.Hippocampal Extracellular Matrix Protein Laminin β1 Regulates Neuropathic Pain and Pain-Related Cognitive Impairment.
Ying-Chun LI ; Pei-Yang LIU ; Hai-Tao LI ; Shuai WANG ; Yun-Xin SHI ; Zhen-Zhen LI ; Wen-Guang CHU ; Xia LI ; Wan-Neng LIU ; Xing-Xing ZHENG ; Fei WANG ; Wen-Juan HAN ; Jie ZHANG ; Sheng-Xi WU ; Rou-Gang XIE ; Ceng LUO
Neuroscience Bulletin 2025;41(12):2127-2147
Patients suffering from nerve injury often experience exacerbated pain responses and complain of memory deficits. The dorsal hippocampus (dHPC), a well-defined region responsible for learning and memory, displays maladaptive plasticity upon injury, which is assumed to underlie pain hypersensitivity and cognitive deficits. However, much attention has thus far been paid to intracellular mechanisms of plasticity rather than extracellular alterations that might trigger and facilitate intracellular changes. Emerging evidence has shown that nerve injury alters the microarchitecture of the extracellular matrix (ECM) and decreases ECM rigidity in the dHPC. Despite this, it remains elusive which element of the ECM in the dHPC is affected and how it contributes to neuropathic pain and comorbid cognitive deficits. Laminin, a key element of the ECM, consists of α-, β-, and γ-chains and has been implicated in several pathophysiological processes. Here, we showed that peripheral nerve injury downregulates laminin β1 (LAMB1) in the dHPC. Silencing of hippocampal LAMB1 exacerbates pain sensitivity and induces cognitive dysfunction. Further mechanistic analysis revealed that loss of hippocampal LAMB1 causes dysregulated Src/NR2A signaling cascades via interaction with integrin β1, leading to decreased Ca2+ levels in pyramidal neurons, which in turn orchestrates structural and functional plasticity and eventually results in exaggerated pain responses and cognitive deficits. In this study, we shed new light on the functional capability of hippocampal ECM LAMB1 in the modulation of neuropathic pain and comorbid cognitive deficits, and reveal a mechanism that conveys extracellular alterations to intracellular plasticity. Moreover, we identified hippocampal LAMB1/integrin β1 signaling as a potential therapeutic target for the treatment of neuropathic pain and related memory loss.
Animals
;
Laminin/genetics*
;
Hippocampus/metabolism*
;
Neuralgia/metabolism*
;
Cognitive Dysfunction/etiology*
;
Male
;
Peripheral Nerve Injuries/metabolism*
;
Extracellular Matrix/metabolism*
;
Integrin beta1/metabolism*
;
Pyramidal Cells/metabolism*
;
Signal Transduction
2.Bioequivalence study of olmesartan medoxomil tablet in Chinese healthy subjects
Na SHAN ; Da-Hai JIANG ; Lin-Lin MIAO ; Zhen-Li REN ; Peng-Bo JIN ; Pei-Qi HAO ; Li AN ; Hong ZHU ; Yong XIN ; Guang-De YANG ; Feng LIU
The Chinese Journal of Clinical Pharmacology 2024;40(20):3033-3037
Objective To study the bioequivalence of test and reference olmesartan tablet in Chinese healthy subjects after single dose under fasting and fed conditions.Methods A single-center,random,open,single-dose,two-preparations,double-period,crossover study was adopted.A total of 48 healthy adult male and female subjects(24 cases of fasting test and 24 cases of fed test)were included in the random crossover administration.Single oral dose 20 mg of test and reference were taken under fasting and postprandial conditions,respectively.Plasma concentration of olmesartan in plasma were determined by liquid chromatography tandem mass spectrometry.The main pharmacokinetic parameters were calculated by Phoenix WinNonlin 8.0 software.Results The main pharmacokinetic parameters of the test and reference preparations of olmesartan tablets in the fasting group were as follows:Cmax were(653.06±133.53)and(617.37±151.16)ng·mL-1,AUC0-t were(4 201.18±1 035.21)and(4 087.38±889.99)ng·mL-1·h,AUC0-∞ were(4 254.30±1 058.90)and(4 135.69±905.29)ng·mL-1·h.The main pharmacokinetic parameters of the test and reference preparations of olmesartan tablets in the postprandial group were as follows:Cmax were(574.78±177.05)and(579.98±107.74)ng·mL-1,AUC0-t were(3 288.37±866.06)and(3 181.51±801.06)ng·mL-1·h,AUC0-∞ were(3 326.11±874.26)and(3 242.01±823.09)ng·mL-1·h.Under fasting and postprandial conditions,the 90%confidence intervals of the main pharmacokinetic parameters of the test and reference preparations are both 80.00%-125.00%.Conclusion Under fasting and postprandial conditions,a single oral dose of test and reference preparations olmesartan tablets in Chinese healthy adult volunteers showed bioequivalence.
3.Study on fatigue vibration evaluation of ultrasonic knife tip based on Q factor
Ke-Sheng WANG ; Ze-Kai LI ; Pei LIU ; Jing-Sheng SUN ; Xu-Guang PENG ; Shuang-Shuang LI ; Qian-Hong HE ; Zhen LIU
Chinese Medical Equipment Journal 2024;45(6):17-22
Objective To propose a Q factor-based fatigue vibration evaluation method of the ultrasonic knife tip.Methods Firstly,an ultrasonic cutter fatigue testing table was established to realize repeated cutting,which was composed of a power supply module,a three-axis moving module,an ultrasonic cutter clamping module and a control module.Secondly,10 ultrasonic knives of some brand underwent fatigue testing with the table,during which non-contact measurement of the ultrasonic knife tip vibration was carried out and the Q factors were calculated at the five periods of the fatigue test,including the periods before cutting,after 500 times of cutting,after 1 000 times of cutting,after 2 000 times of cutting and after 3 000 times of cutting.Finally,the average cutting speed and burst pressure for coagulated vessels were computed at each period to validata the effectiveness of the method proposed.Results It's indicated that Q factor could effectively reflect the fatigue degradation of the ultrasonic knife tip,while the average cutting speed and burst pressure for coagulated vessels were difficult to efficiently evaluate the fatigue degradation level of the ultrasonic knife tip due to the uncertainty factors in the measurement process.Conclusion The proposed Q factor-based evaluation method can directly evaluate fatigue vibration of the ultrasonic knife tip in an accurate and quantitative manner.[Chinese Medical Equipment Journal,2024,45(6):17-22]
4.Accurate quantitative evaluation of MRI scanning noise based on laser vibrometry technology
Ke-Sheng WANG ; Pei-Jia XU ; Pei LIU ; Jing-Sheng SUN ; Ze-Kai LI ; Xu-Guang PENG ; Shuang-Shuang LI ; Qian-Hong HE ; Zhen LIU
Chinese Medical Equipment Journal 2024;45(10):20-24
Objective To carry out accurate quantative evaluation of MRI scanning noise based on laser vibrometry technology.Methods Skull and spine MRI was performed with mute and conventional sequences.A laser vibrometry device was used to sample the surface vibration noise at the outer edge of the inspection hole of MRI system according to GB/T 16539-1996 Acoustics—Determination of sound power levels of noise sources using vibration velocity—Measurement for seal machinery,and the indicators of sound power level,sound pressure level and perceived noise level obtained by the three calculation methods(LPN1,LPN2 and LPN3)were analyzed with some dedicated MRI noise analysis software.Results The peak sound pressure levels for conventional and mute sequences of skull scanning were 81 and 63 dB(A),respectively,and mute sequence reduced the noise level significantly;the peak sound pressure levels for conventional and mute sequences of spine scanning were 79 and 75 dB(A),respectively,and the noise reduction level was significantly lower than that of skull scanning.Significant differences in noise reduction were not found in spine scanning sequences,while were found in skull scanning sequences.During spine and skull scanning LPN1,LPN2 and LPN3 obtained by the three calculation methods of conventional and mute sequences were all higher than the overall sound power and overall pressure levels obviously.Conclusion Mute sequence can not realize linear noise reduction for the whole frequency band,the perceived noise of the human ear during MRI scanning is related directly to the scanning sequence,and there may be some bias when only one physical indicator is involved in the noise evaluation of MRI system.[Chinese Medical Equipment Journal,2024,45(10):20-24]
5.Meta-analysis on the incidence of long COVID in Omicron-infected pa-tients
Li-Yu WANG ; Shi-Wei WU ; Meng-Qi XU ; Bao-Guang LIU ; Lan-Ying PEI ; Guo-Li YAN ; Guan-Min ZHENG
Chinese Journal of Infection Control 2024;23(11):1384-1390
Objective To explore the incidence of long CO VID symptoms in patients infected with Omicron variant of severe acute respiratory syndrome coronavirus 2(SARS-CoV-2).Methods According to the inclusion and exclu-sion criteria of literatures,relevant studies without language restrictions published up to 2024 were retrieved from both Chinese and English databases.The Chinese databases were China National Knowledge Infrastructure(CNKI),Wanfang Database,and VIP databases,and the foreign databases were PubMed,Embase,and Web of Science.Three-step screening was used to select literatures,and Stata 17.0 software was used for analysis.Results The incidence of at least one sequelae in patients infected with Omicron variant was 29.62%.The most common symptoms included fatigue(19.10%),joint or muscle pain(11.06%),memory loss(9.71%),brain fog(8.80%),cough(8.42%),headache(7.26%),and sore throat(6.68%).Subgroup analysis results showed that with the extension of follow-up(3 months vs 6 months),the incidence of smell or taste changes was significantly re-duced(7.22%vs 0.78%).The higher the proportion of women(<50%vs 50%-65%vs>65%),the higher the incidence of joint or muscle pain(1.09%vs 4.62%vs 19.53%);the greater the median age(≥45 years vs<45 years),the higher the incidence of chest pain or chest distress(0.90%vs 3.86%),all with statistically significant differences(all P<0.05).Conclusion Incidence of long COVID in Omicron-infected patients is high and can cause various symptoms.Follow-up time,median age and gender proportion have significant impacts on the incidence of some symptoms.
6.Morphological classification and molecular identification of Hyalomma asiaticum in parts of Xindi Township,Xinjiang
Xiao-Qing ZAN ; Qiao-Yun REN ; Jin LUO ; Yan-Long WANG ; Pei-Wen DIAO ; Li-Yan CHE ; Jian-Xun LUO ; Hong YIN ; Gui-Quan GUAN ; Guang-Yuan LIU ; Hong-Xi ZHAO
Chinese Journal of Zoonoses 2024;40(4):289-294
The purpose of this study was to identify the tick species native to Xindi Township,Yumin County,Xinjiang,China.Preliminary morphological identification of parasitic ticks collected from animals in the area was conducted with an ultra-depth of field three-dimensional VHX 600 digital stereo microscope.Total DNA of the ticks was extracted,amplified by PCR based on the COI and ITS2 gene loci,and the posi-tive PCR products were sequenced.The sequence were a-ligned with reference sequences from the NCBI database were aligned with the Basic Local Alignment Search Tool.A genet-ic phylogenetic tree was generated with the neighbor-joining method of MEGA 7.0 software to determine the evolutionary biological characteristics of ticks.Morphological identification showed that the ticks collected from Xindi Township of Yu-min County were consistent with the characteristics of Hya-lomma asiaticum.An evolutionary tree based on the COI and ITS2 gene sequences showed that the ticks collected in this study were clustered with known H.asiaticum sequences.The PCR products of COI and ITS2 were sequenced and compared,which confirmed that the collected tick species were H.asiaticum,in agreement with the morphological and molecular biological results.These findings help to clarify the distribution of ticks in Xindi Township of Xinjiang,and provide basic data for the analysis of tick genetic and evolutionary characteristics,as reference for surveillance and control of ticks in the Xinjiang Uygur Autonomous Region.
7.Correlation between axial lengths and anterior segment parameters evaluated by swept-source optical coherence tomography
Min ZHANG ; Guang-Qi AN ; Pei LIU ; Fan YANG ; Bo JIN ; Xue-Min JIN ; Li-Ping DU
International Eye Science 2023;23(8):1338-1342
AIM:To evaluate the correlation between axial lengths and anterior segment parameters using swept-source optical coherence tomography(SS-OCT).METHODS:For the cross-sectional clinical study, a total of 109 adult volunteers with different degrees of myopia recruited from January 1, 2022, to March 31, 2022, at the ophthalmology clinic of the First Affiliated Hospital of Zhengzhou University were included. Participants were divided into 4 groups based on axial length(AL): group A(AL≤24.0mm), group B(24.0mm
8.Effects of Platycodonis Radix-Curcumae Rhizoma on oral nanoparticle uptake and in vitro inhibition against breast cancer metastasis.
Jiang-Pei SHI ; Rong-Guang ZHANG ; Xiao-Yan GU ; Ying-Wei SUN ; Nian-Ping FENG ; Ying LIU
China Journal of Chinese Materia Medica 2023;48(9):2419-2425
This study combined the herbal pair Platycodonis Radix-Curcumae Rhizoma(PR-CR) possessing an inhibitory effect on tumor cell proliferation and metastasis with the active component of traditional Chinese medicine(TCM) silibinin-loaded nanoparticles(NPs) with a regulatory effect on tumor microenvironment based on the joint effect on tumor cells and tumor microenvironment to inhi-bit cell metastasis. The effects of PR-CR on the cellular uptake of NPs and in vitro inhibition against breast cancer proliferation and metastasis were investigated to provide an experimental basis for improving nanoparticle absorption and enhancing therapeutic effects. Silibinin-loaded lipid-polymer nanoparticles(LPNs) were prepared by the nanoprecipitation method and characterized by transmission electron microscopy. The NPs were spherical or quasi-spherical in shape with obvious core-shell structure. The mean particle size was 107.4 nm, Zeta potential was-27.53 mV. The cellular uptake assay was performed by in vitro Caco-2/E12 coculture cell model and confocal laser scanning microscopy(CLSM), and the results indicated that PR-CR could promote the uptake of NPs. Further, in situ intestinal absorption assay by the CLSM vertical scanning approach showed that PR-CR could promote the absorption of NPs in the enterocytes of mice. The inhibitory effect of NPs on the proliferation and migration of 4T1 cells was analyzed using 4T1 breast cancer cells and co-cultured 4T1/WML2 cells, respectively. The results of the CCK8 assay showed that PR-CR-containing NPs could enhance the inhibition against the proliferation of 4T1 breast cancer cells. The wound healing assay indicated that PR-CR-containing NPs enhanced the inhibition against the migration of 4T1 breast cancer cells. This study enriches the research on oral absorption of TCM NPs and also provides a new idea for utilizing the advantages of TCM to inhibit breast cancer metastasis.
Humans
;
Mice
;
Animals
;
Female
;
Silybin/therapeutic use*
;
Caco-2 Cells
;
Polymers/chemistry*
;
Nanoparticles/chemistry*
;
Cell Line, Tumor
;
Breast Neoplasms/pathology*
;
Tumor Microenvironment
9.Clinical Value of Translocator Protein Gene in Evaluating the Efficacy of FLT3-ITD/DNMT3A R882 Double-Mutated Acute Myeloid Leukemia.
Shan-Hao TANG ; Ying LU ; Pi-Sheng ZHANG ; Dong CHEN ; Xu-Hui LIU ; Xiao-Hong DU ; Jun-Jie CAO ; Shuang-Yue LI ; Ke-Ya SHA ; Lie-Guang CHEN ; Xian-Xu ZHUANG ; Pei-Pei YE ; Li LIN ; Ren-Zhi PEI
Journal of Experimental Hematology 2023;31(1):45-49
OBJECTIVE:
To observe the clinical significance of translocator proteins (TSPO) gene in the treatment of FLT3-ITD/DNMT3A R882 double-mutated acute myeloid leukemia (AML).
METHODS:
Seventy-six patients with AML hospitalized in the Department of Hematology of the Affiliated People's Hospital of Ningbo University from June 2018 to June 2020 were selected, including 34 patients with FLT3-ITD mutation, 27 patients with DNMT3A R882 mutation, 15 patients with FLT3-ITD/DNMT3A R882 double mutation, as well as 19 patients with immune thrombocytopenia (ITP) hospitalized during the same period as control group. RNA was routinely extracted from 3 ml bone marrow retained during bone puncture, and TSPO gene expression was detected by transcriptome sequencing (using 2-deltadeltaCt calculation).
RESULTS:
The expression of TSPO gene in FLT3-ITD group and DNMT3A R882 group at first diagnosis was 2.02±1.04 and 1.85±0.76, respectively, which were both higher than 1.00±0.06 in control group, but the differences were not statistically significant (P=0.671, P=0.821). The expression of TSPO gene in the FLT3-ITD/DNMT3A R882 group was 3.98±1.07, wich was significantly higher than that in the FLT3-ITD group and DNMT3A R882 group, the differences were statistically significant (P=0.032, P=0.021). The expression of TSPO gene in patients who achieved complete response after chemotherapy in the FLT3-ITD/DNMT3A R882 group was 1.19±0.87, which was significantly lower than that at first diagnosis, and the difference was statistically significant (P=0.011).
CONCLUSION
TSPO gene may be used as an indicator of efficacy in FLT3-ITD /DNMT3A R882 double-mutated AML.
Humans
;
DNA (Cytosine-5-)-Methyltransferases/genetics*
;
DNA Methyltransferase 3A
;
Mutation
;
Leukemia, Myeloid, Acute/drug therapy*
;
Nucleophosmin
;
Prognosis
;
fms-Like Tyrosine Kinase 3/genetics*
;
Receptors, GABA/therapeutic use*
10.Image-guided Strategy of Intensity-modulated Radiotherapy in Helical Tomography for Nasopharyngeal Carcinoma
Meng-xue HE ; Pei-xun XU ; Hong HUANG ; Xuan-guang CHEN ; Hui-lang HE ; Zi-xian ZHANG ; Hui LIU ; Sen-kui XU ; Wen-yan YAO
Journal of Sun Yat-sen University(Medical Sciences) 2023;44(1):131-137
ObjectiveThis study aimed to analyze the difference in setup error before and after correction of systematic error. To determine the most appropriate image-guided strategy during HT treatment, we use different scanning ranges and image-guidance frequencies in patients with nasopharyngeal carcinoma (NPC) treated with helical tomotherapy (HT). MethodsFifteen patients with NPC who received HT treatment in Sun Yat-sen University Cancer Center from October 2019 to February 2020 were selected. Megavoltage computed tomography (MVCT) scanning was performed before each treatment. After five times of radiotherapy, system-error correction was performed to adjust the setup center. The setup errors before and after the correction of systematic errors, as well as the setup errors of different scanning ranges and different scanning frequencies, were collected for analysis and comparison. ResultsWhen comparing the setup errors before and after the correction of systematic error, the differences in setup errors in the left–right (LR), superior–inferior (SI), and anterior–posterior (AP) directions were statistically significant (P<0.05).The different scanning ranges of "nasopharynx + neck" and "nasopharynx" were compared, and a statistically significant difference was found in yaw rotational errors (P<0.05). In the comparison of daily and weekly scan frequency after system-error correction, a significant difference was found in AP direction (P<0.05). ConclusionDuring radiotherapy for NPC, the systematic error can be corrected according to the first five setup errors, and then small-scale scanning was selected for image-guided radiotherapy every day.

Result Analysis
Print
Save
E-mail