1.Clinical Efficacy of Tangning Tongluo Tablets for Nonproliferative Diabetic Retinopathy
Fuwen ZHANG ; Junguo DUAN ; Wen XIA ; Tiantian SUN ; Yuheng SHI ; Shicui MEI ; Xiangxia LUO ; Xing LI ; Yujie PAN ; Yong DENG ; Chuanlian RAN ; Hao CHEN ; Li PEI ; Shuyu YANG
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(3):132-139
ObjectiveTo observe the clinical efficacy and safety of Tangning Tongluo tablets in the treatment of nonproliferative diabetic retinopathy (DR). MethodsFourteen research centers participated in this study, which spanned a time interval from September 2021 to May 2023. A total of 240 patients with nonproliferative DR were included and randomly assigned into an observation group (120 cases) and a control group (120 cases). The observation group was treated with Tangning Tongluo tablets, and the control group with calcium dobesilate capsules. Both groups were treated for 24 consecutive weeks. The vision, DR progression rate, retinal microhemangioma, hemorrhage area, exudation area, glycosylated hemoglobin (HbA1c) level, and TCM syndrome score were assessed before and after treatment, and the safety was observed. ResultsThe vision changed in both groups after treatment (P<0.05), and the observation group showed higher best corrected visual acuity (BCVA) than the control group (P<0.05). The DR progression was slow with similar rates in the two groups. The fundus hemorrhage area and exudation area did not change significantly after treatment in both groups, while the observation group outperformed the control group in reducing the fundus hemorrhage area and exudation area. There was no significant difference in the number of microhemangiomas between the two groups before treatment. After treatment, the number of microhemangiomas decreased in both the observation group (Z=-1.437, P<0.05) and the control group (Z=-2.238, P<0.05), and it showed no significant difference between the two groups. As the treatment time prolonged, the number of microhemangiomas gradually decreased in both groups. There was no significant difference in the HbA1c level between the two groups before treatment. After treatment, the decline in the HbA1c level showed no significant difference between the two groups. The TCM syndrome score did not have a statistically significant difference between the two groups before treatment. After treatment, neither the TCM syndrome score nor the response rate had significant difference between the two groups. With the extension of the treatment time, both groups showed amelioration of TCM syndrome compared with the baseline. ConclusionTangning Tongluo tablets are safe and effective in the treatment of nonproliferative DR, being capable of improving vision and reducing hemorrhage and exudation in the fundus.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Analysis of early acute gastrointestinal injury and its influencing factors in patients with extracorporeal membrane oxygenation
Wenxue JIANG ; Chunxi PAN ; Yanlin WEI ; Qiao WEI ; Chi WANG ; Mingyu PEI ; Liwen LYU
Chinese Journal of Emergency Medicine 2024;33(2):210-214
Objective:To investigate the acute gastrointestinal injury (AGI) in patients with extracorporeal membrane oxygenation (ECMO) at the early stage of operation and its influencing factors.Methods:A total of 70 patients with ECMO who were hospitalized in the Emergency Care Unit of Guangxi Zhuang Autonomous Region People's Hospital from September 2020 to December 2021 were retrospectively analyzed, and a total of 70 patients with ECMO who were hospitalized in the emergency care unit of Guangxi Zhuang Autonomous Region People's Hospital from September 2020 to December 2021 were retrospectively analyzed. According to the 2012 guidelines of the European Society of Intensive Care Medicine on the classification of acute gastrointestinal injury in critically ill patients, the patients were divided into AGI group and non-AGI group. The incidence of acute gastrointestinal injury in the early stage was statistically analyzed, and the results of blood gas analysis during ECMO loading and ECMO parameters, hemodynamic indexes and biochemical indexes after ECMO transfer were statistically analyzed. To explore the influencing factors and independent risk factors of AGI in the early stage. In addition, 70 patients were divided into successful group and non-successful group according to whether they were successfully withdrawn. The occurrence of acute gastrointestinal injury between the two groups was compared, and the effect of acute gastrointestinal injury on ECMO patients was analyzed.Results:Among the 70 ECMO patients, the incidence of early AGI was 71.43% (50 cases), and the components of AGI Ⅰ, Ⅱ, Ⅲ and Ⅳ were 18.57% (13 cases), 41.43% (29 cases), 11.43% (8 cases) and 0% (0 cases), respectively. ① Univariate analysis showed that systolic blood pressure, diastolic blood pressure, mean arterial pressure (MAP), vasoactive drug index (VIS), pH, lactic acid and BMI were significantly different between AGI group and non-AGI group when ECMO was used ( P < 0.05). Logistic binary regression analysis showed that BMI was an independent risk factor for early AGI in ECMO patients (ROC area 0.657, 95% confidence interval 0.522-0.791 ( P < 0.05), and Yoden index 0.15). (3) The AGI composition ratio of the unsuccessful group was higher than that of the unsuccessful group ( P < 0.05). Conclusions:Patients with ECMO have a high incidence of AGI in the early stage, mainly occurring in grade I and Ⅱ. Systolic blood pressure, diastolic blood pressure, MAP, VIS, pH, lactic acid and BMI when ECMO is put on are influential factors for the early development of AGI in ECMO patients, among which BMI is an independent risk factor for the early development of AGI in ECMO patients. The occurrence of AGI reduces the probability of successful withdrawal in ECMO patients.
8.Desalination effect on FⅧ components: a compartive study among 5 desalination methods
Renjun PEI ; Xi DU ; Pan SUN ; Xiaoyue LI ; Peng JIANG ; Changqing LI ; Fangzhao LIN ; Haijun CAO
Chinese Journal of Blood Transfusion 2024;37(3):304-311
【Objective】 To compare the desalination effects of five desalination methods and their effects on the components for human coagulation factor Ⅷ(FⅧ), and provide reference for selection of protein desalination methods. 【Methods】 Sephadex G-25 Medium gel, Fractogel EMD BioSEC gel, ultrafiltration, room temperature dialysis and 4℃ dialysis were used to desalt human FⅧ. The desalination effect was evaluated by the removal rate of Na +, citrate ion and glycine. FⅧ protein recovery, FⅧ activity (FⅧ∶C), VWF antigen (VWF∶Ag), VWF activity(VWF∶Ac), VWF polymers and SDS-PAGE analysis before and after desalination were compared to evaluate the effect of desalination on FⅧ components. 【Results】 In terms of desalination effect, the removal rate of Na+ was the lowest in ultrafiltration desalination, while that of Fractogel EMD BioSEC gel was the highest [(97.90±0.06) % vs (99.82±0.07) %]. Except that there was no statistical significance between Sephadex G-25 Medium gel desalination and Fractogel EMD BioSEC gel desalination (P=0.90), the removal rates of the other four methods were statistically significant. The removal rate of glycine was the lowest in ultrafiltration desalination, wihle that of Fractogel EMD BioSEC gel desalination was the highest [(95.78±0.42) % vs (99.81±0.08) %]. Significant difference in glycine removal was noticed in ultrafiltration desalination, but not among the other four desalination methods. There was no significant difference in the removal rate of citrate ions among the five methods (P=0.85). For the effect of FⅧ components, FⅧ∶C, VWF∶Ag, VWF∶Ac and protein recovery rates of ultrafiltration desalination were the highest, with (18.34±1.99) IU/mL, (11.81±0.33) IU/mL, (12.26±0.58) IU/mL and (97.13±1.37) %, respectively. There was no significant change in VWF∶Ac/VWF∶Ag before and after desalination by the five methods. SDS-PAGE and VWF polymer analysis showed that different desalination methods had no significant impact on protein composition. 【Conclusion】 Although different desalination methods had no significant effect on the composition of FⅧ protein, the desalination effect was different. Moreover, different desalination methods had significant effects on protein recovery, FⅧ∶C, VWF∶Ag and VWF∶Ac. The selection of desalination methods should be more considered during protein processing,
9.MoS2 nanozyme attenuated inflammation-related endothelial cell injury by regulating mitochondrial dynamics and mitophagy
Dong-mei PAN ; Sun-kui KE ; Qian-hao YIN ; Pei-yan YANG ; Chao LI ; She-fang YE
Acta Pharmaceutica Sinica 2024;59(10):2791-2799
To explore the protective mechanisms of a novel molybdenum disulfide (MoS2) nanozyme in alleviating inflammation-related endothelial cell injury by regulating mitochondrial dynamic, flower like-MoS2 nanosheets were prepared by hydrothermal method, and its antioxidant enzyme-mimic activities were assessed
10.The application of percutaneous puncture renal fascia suspension in laparoscopic partial nephrectomy
Qi LI ; Pei ZHENG ; Yusheng WANG ; Guangyuan JING ; Mingrui WANG ; Bo ZHAO ; Tengfei XU ; Xiaoli WANG ; Kaidong WANG ; Xiao PAN ; Fen YIN
Chinese Journal of Urology 2024;45(1):53-54
When partial nephrectomy is performed by posterior abdominal approach, the surgical field is poorly exposed, resulting in increased surgical difficulty and risk of injury.In this study, 28 patients with T 1a stage kidney tumors underwent retroperitoneal laparoscopic partial nephrectomy. Intraoperatively, exposure of the surgical field was achieved using the percutaneous puncture of the renal fascia suspension technique. There were no dissatisfactory exposures due to peritoneal damage during the surgery, no additional tubes were inserted, and no conversions to open surgery were needed. The operation time was (76.5±20.3) minutes, blood loss was (92.1±18.7) ml, renal artery clamping time was (19.5±4.3) minutes. Postoperatively, there were no complications such as bleeding, infection, or hematuria.

Result Analysis
Print
Save
E-mail