1.Effect modification of amino acid levels in association between polycyclic aromatic hydrocarbon exposure and metabolic syndrome: A nested case-control study among coking workers
Jinyu WU ; Jiajun WEI ; Shugang GUO ; Huixia XIONG ; Yong WANG ; Hongyue KONG ; Liuquan JIANG ; Baolong PAN ; Gaisheng LIU ; Fan YANG ; Jisheng NIE ; Jin YANG
Journal of Environmental and Occupational Medicine 2025;42(3):325-333
		                        		
		                        			
		                        			Background Exposure to polycyclic aromatic hydrocarbons (PAHs) is associated with the development of metabolic syndrome (MS). However, the role of amino acids in PAH-induced MS remains unclear. Objective To explore the impact of PAHs exposure on the incidence of MS among coking workers, and to determine potential modifying effect of amino acid on this relationship. Methods Unmatched nested case-control design was adopted and the baseline surveys of coking workers were conducted in two plants in Taiyuan in 2017 and 2019, followed by a 4-year follow-up. The cohort comprised 667 coking workers. A total of 362 participants were included in the study, with 84 newly diagnosed cases of MS identified as the case group and 278 as the control group. Urinary levels of 11 PAH metabolites and plasma levels of 17 amino acids were measured by ultrasensitive performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). Logistic regression was used to estimate the association between individual PAH metabolites and MS. Stratified by the median concentration of amino acids, Bayesian kernel machine regression (BKMR) model was employed to assess the mixed effects of PAHs on MS. Due to the skewed data distribution, all PAH metabolites and amino acids in the analysis were converted by natural logarithm ln (expressed as lnv). Results The median age of the 362 participants was 37 years, and 83.2% were male. Compared to the control group, the case group exhibited higher concentrations of urinary 2-hydroxyphenanthrene (2-OHPhe), 9-hydroxyphenanthrene (9-OHPhe), and hydroxyphenanthrene (OHPhe) (P=0.005, P=0.049, and P=0.004, respectively), as well as elevated levels of plasma branched chain amino acid (BCAA) and aromatic amino acid (AAA) (P<0.05). After being adjusted for confounding factors, for every unit increase in lnv2-OHPhe in urine, the OR (95%CI) of MS was 1.57 (1.11, 2.26), and for every unit increase in lnvOHPhe, the OR (95%CI) of MS was 1.82 (1.16, 2.90). Tyrosine, leucine, and AAA all presented a significant nonlinear correlation with MS. At low levels, tyrosine, leucine, and AAA did not significantly increase the risk of MS, but at high levels, they increased the risk of MS. In the low amino acid concentration group, as well as in the low BCAA and low AAA concentration groups, it was found that compared to the PAH metabolite levels at the 50th percentile (P50), the log-odds of MS when the PAH metabolite levels was at the 75th percentile (P75) were 0.158 (95%CI: 0.150, 0.166), 0.218 (95%CI: 0.209, 0.227), and 0.262 (95% CI: 0.241, 0.282), respectively, However, no correlation between PAHs and MS was found in the high amino acid concentration group. Conclusion Amino acids modify the effect of PAHs exposure on the incidence of MS. In individuals with low plasma amino acid levels, the risk of developing MS increases with higher concentrations of mixed PAH exposure. This effect is partly due to the low concentrations of BCAA and AAA.
		                        		
		                        		
		                        		
		                        	
2.Impacts of ambient air pollutants on childhood asthma from 2019 to 2023: An analysis based on asthma outpatient visits of Nanjing Children's Hospital
Li WEI ; Xing GONG ; Lilin XIONG ; Yi ZHANG ; Fengxia SUN ; Wei PAN ; Changdi XU
Journal of Environmental and Occupational Medicine 2025;42(4):408-414
		                        		
		                        			
		                        			Background Asthma poses a serious threat to children's growth, development, and mental health, thus there has been an increasing focus on the control of asthma morbidity in children and the assessment of its risk factors. A growing body of research has found that exposure to ambient air pollutants an significatly increase the risk of childhood asthma. Objective To understand the changes of ambient air pollutant concentrations in Nanjing and asthma outpatient visits to Nanjing Children's Hospital, and to quantitatively analyze the effects of exposure to different ambient air pollutants on children's asthma outpatient visits. Methods Daily data of ambient air pollutants fine particulate matter (PM2.5), inhalable particle (PM10), sulfur dioxide (SO2), nitrogen dioxide (NO2), carbon monoxide (CO), ozone (O3), meteorological factors (air temperature & relative humidity), and outpatient visits due to asthma in the hospital from January 1, 2019 to December 31, 2023 were collected, and a generalized additive model based on quasi poisson distributions was used to quantitatively analyze the short-term effects of ambient air pollutant exposure on outpatient visits due to asthma in the hospital. Results The annual average concentrations of PM2.5, PM10, SO2, and NO2 in Nanjing from 2019 to 2023 did not exceed the national limits. For single-day lagged effects, the single-pollutant model showed that the effects of PM2.5, PM10, NO2, and CO on children's asthma outpatient visits were greatest for every 10 units increase at lag0, with excess risk (ER) of 1.39% (95%CI: 0.65%, 2.14%), 1.46% (95%CI: 0.97%, 1.95%), 5.46% (95%CI: 4.36%, 6.57%), and 0.18% (95%CI: 0.11%, 0.26%), respectively, and SO2 reached the maximum effect at lag1, with an ER of 23.15% (95%CI: 13.57%, 33.53%) for each 10 units increase in concentration. Different pollutants reached their maximum cumulative lag effects at different time. The PM10, PM2.5, SO2, NO2, and CO showed the largest cumulative lag effects at lag01, lag01, lag02, lag02, and lag03, respectively, with ERs of 1.35% (95%CI: 0.77%, 1.92%), 0.96% (95%CI: 0.10%, 1.83%), 28.50% (95%CI: 15.49%, 42.98%), 6.92% (95%CI: 5.53%, 8.33%), and 0.31% (95%CI: 0.20%, 0.42%), respectively. The influences of PM2.5 and PM10 on outpatient visits due to asthma in the hospital became more pronounced with advancing age, while the associations with NO₂, SO₂, and CO were weakened as children grew older. Conclusion Ambient air pollutants (PM2.5, PM10, SO2, NO2, CO) can increase childhood asthma visits, and different pollutants have varied effects on the number of asthmatic children's visits at different ages.
		                        		
		                        		
		                        		
		                        	
3.Research status and advances in immunotherapy for chronic myeloid leukemia
Mengmeng WANG ; Jingyun MA ; Boyu XIONG ; Zhuowen DAI ; Yueyue PAN ; Qiong WANG
Chinese Journal of Blood Transfusion 2025;38(5):739-746
		                        		
		                        			
		                        			Chronic myeloid leukemia (CML) is a malignant hematologic disorder caused by abnormal proliferation of hematopoietic stem cells. In recent years, while the application of tyrosine kinase inhibitors (TKIs) has significantly improved the prognosis of CML patients through in-depth exploration of pathogenesis of CML and advancements in targeted therapies, some patients still face challenges including drug resistance, disease relapse, and failure to achieve treatment-free remission. Imunotherapy, as a complementary or alternative strategy, holds significant potential for overcoming these limitations, and has gradually emerged as a critical research focus in CML treatment. This review aims to summarize the current research status and latest advances in immunotherapy for CML.
		                        		
		                        		
		                        		
		                        	
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
9.High-level expression of anti FLAG tag antibody in plants.
Zhicheng KONG ; Xiaoran XIONG ; Chuan WU ; Weisong PAN
Chinese Journal of Biotechnology 2024;40(1):269-279
		                        		
		                        			
		                        			Plant bioreactor is a new production platform for expression of recombinant protein, which is one of the cores of molecular farming. In this study, the anti DYKDDDDK (FLAG) antibody was recombinantly expressed in tobacco (Nicotiana benthamiana) and purified. FLAG antibody with high affinity was obtained after immunizing mice for several times and its sequence was determined. Based on this, virus vectors expressing heavy chain (HC) and light chain (LC) inoculated into Nicotiana benthamiana leaves by using Agrobacterium-mediated delivery. Accumulation of the HC and LC was analyzed by SDS/PAGE followed by Western blotting probed with specific antibodies from 2 to 9 days postinfiltration (dpi). Accumulation of the FLAG antibody displayed at 3 dpi, and reached a maximum at 5 dpi. It was estimated that 66 mg of antibody per kilogram of fresh leaves could be obtained. After separation and purification, the antibody was concentrated to 1 mg/mL. The 1:10 000 diluted antibody can probe with 1 ng/mL FLAG fused antigen well, indicating the high affinity of the FLAG antibody produced in plants. In conclusion, the plant bioreactor is able to produce high affinity FLAG antibodies, with the characteristics of simplicity, low cost and highly added value, which contains enormous potential for the rapid and abundant biosynthesis of antibodies.
		                        		
		                        		
		                        		
		                        			Animals
		                        			;
		                        		
		                        			Mice
		                        			;
		                        		
		                        			Antibodies
		                        			;
		                        		
		                        			Nicotiana/genetics*
		                        			;
		                        		
		                        			Agrobacterium/genetics*
		                        			;
		                        		
		                        			Bioreactors
		                        			;
		                        		
		                        			Blotting, Western
		                        			
		                        		
		                        	
10.Bone remodeling in the Masquelet-induced membrane model of rat femur by modulation of H-type vessels by total flavonoids of rhizome drynariae
Zhikui ZENG ; Wei XIONG ; Weidong LIANG ; Guowen QIAN ; Chaoyi LIANG ; Bin PAN ; Ling GUO ; Wenqiang WEI ; Xunxiang QIU ; Wenfang DENG ; Lingmei YUAN
Chinese Journal of Tissue Engineering Research 2024;28(32):5130-5135
		                        		
		                        			
		                        			BACKGROUND:Several studies have found that the total flavonoids of rhizome drynariae can promote neovascularization in the induced membrane,improve the biological properties of the induced membrane,and accelerate bone remodeling in the induced membrane,but the related molecular mechanisms still need to be further explored. OBJECTIVE:To explore the effect of total flavonoids of rhizome drynariae on bone remodeling in rat femoral Masquelet-induced membrane model by regulating H-type blood vessels. METHODS:Thirty-six male Sprague-Dawley rats were stratified by body mass and then randomly divided into blank group,model group and traditional Chinese medicine group,with 12 rats in each group.A 4-mm femoral bone defect model was established in all the rats.Bone defects in the model group and traditional Chinese medicine group were filled with polymethylmethacrylate bone cement.At 6 weeks after modeling,the tail bone of the rats was implanted in the blank group,as well as in the other two groups after removal of bone cement.The traditional Chinese medicine group was given 157.5 mg/kg per day of total flavonoids of rhizome drynariae at 3 days after bone implantation,while the model and blank groups were given the same amount of saline by gavage until the 8th week after bone implantation.Bone graft samples were taken for relevant testing at 8 weeks after implantation. RESULTS AND CONCLUSION:X-ray films showed that in the blank group,the fracture line in the defect area was clear,and only a small amount of bone callus formed;in the model group,the bone defect area still existed,where discontinuous cortical bone was visible;in the traditional Chinese medicine group,the defect area was filled with newborn bone tissues,the bone marrow cavity and part of the cortical bone formed,and the fracture line disappeared.Micro-CT scans showed that the amount of new bone in the defect area was low in the blank group,the number of bone trabeculae in the defect area was significantly increased in the model group,and a large amount of new bone tissue was filled in the bone defect area in the traditional Chinese medicine group.Hematoxylin-eosin staining results showed that in the blank group,only a small amount of new bone formed in the defect area and the quality of osteogenesis was poor;in the model group,there was more new bone tissue in the defect area,but some fibrous connective tissues were interspersed within the bone tissue;and in the traditional Chinese medicine group,a large amount of new bone formed in the defect area and the quality of osteogenesis was the best.CD31/Emcn immunofluorescence double-labeling staining results showed that the number of H-type blood vessels in the newborn bone tissue in the bone defect area of the blank group was sparse and sparsely distributed;compared with the blank group,there were more H-type blood vessels in the bone tissue in the bone defect area of the model group,and the blood vessels were distributed in relatively regular strips;the number of H-type blood vessels in the bone defect area of the traditional Chinese medicine group was the highest and the blood vessels were densely distributed.To conclude,the total flavonoids of rhizoma drynariae can upregulate the expression of H-type blood vessels to enhance the angiogenic-osteogenic effect,improve the osteogenic efficiency of the rat femoral Masquelet induced membrane model,and promote bone remodeling.
		                        		
		                        		
		                        		
		                        	
            
Result Analysis
Print
Save
E-mail