1.Research progress on valgus impacted proximal humeral fractures.
Bo LI ; Shimin CHANG ; Sunjun HU ; Shouchao DU ; Wenfeng XIONG
Chinese Journal of Reparative and Reconstructive Surgery 2024;38(1):107-112
OBJECTIVE:
To review the advancement made in the understanding of valgus impacted proximal humeral fracture (PHF).
METHODS:
The domestic and foreign literature about the valgus impacted PHF was extensively reviewed and the definition, classification, pathological features, and treatment of valgus impacted PHFs were summarized.
RESULTS:
PHF with a neck shaft angle ≥160° is recognized as a valgus impacted PHF characterized by the preservation of the medial epiphyseal region of the humeral head, which contributes to maintenance of the medial periosteum's integrity after fracture and reduces the occurrence of avascular necrosis. Therefore, the valgus impacted PHF has a better prognosis when compared to other complex PHFs. The Neer classification designates it as a three- or four-part fracture, while the AO/Association for the Study of Internal Fixation (AO/ASIF) categorizes it as type C (C1.1). In the management of the valgus impacted PHF, the selection between conservative and surgical approaches is contingent upon the patient's age and the extent of fracture displacement. While conservative treatment offers the advantage of being non-invasive, it is accompanied by limitations such as the inability to achieve anatomical reduction and the potential for multiple complications. Surgical treatment includes open reduction combined with steel wire or locking plate and/or non-absorbable suture, transosseous suture technology, and shoulder replacement. Surgeons must adopt personalized treatment strategies for each patient with a valgus impacted PHF. Minimally invasive surgery helps to preserve blood supply to the humeral head, mitigate the likelihood of avascular necrosis, and reduce postoperative complications of bone and soft tissue. For elderly patients with severe comminuted and displaced fractures, osteoporosis, and unsuitable internal fixation, shoulder joint replacement is the best treatment option.
CONCLUSION
Currently, there has been some advancement in the classification, vascular supply, and management of valgus impacted PHF. Nevertheless, further research is imperative to assess the clinical safety, biomechanical stability, and indication of minimally invasive technology.
Aged
;
Humans
;
Bone Plates
;
Bone Wires
;
Fracture Fixation, Internal/adverse effects*
;
Fractures, Comminuted/surgery*
;
Humeral Fractures
;
Osteonecrosis
;
Retrospective Studies
;
Shoulder Fractures/surgery*
;
Treatment Outcome
2.Research progress on biomechanics for internal fixation in tibial plateau fracture.
Jialun LIU ; Yingze ZHANG ; Zhanle ZHENG
Chinese Journal of Reparative and Reconstructive Surgery 2024;38(1):113-118
OBJECTIVE:
To review the biomechanical research progress of internal fixation of tibial plateau fracture in recent years and provide a reference for the selection of internal fixation in clinic.
METHODS:
The literature related to the biomechanical research of internal fixation of tibial plateau fracture at home and abroad was extensively reviewed, and the biomechanical characteristics of the internal fixation mode and position as well as the biomechanical characteristics of different internal fixators, such as screws, plates, and intramedullary nails were summarized and analyzed.
RESULTS:
Tibial plateau fracture is one of the common types of knee fractures. The conventional surgical treatment for tibial plateau fracture is open or closed reduction and internal fixation, which requires anatomical reduction and strong fixation. Anatomical reduction can restore the normal shape of the knee joint; strong fixation provides good biomechanical stability, so that the patient can have early functional exercise, restore knee mobility as early as possible, and avoid knee stiffness. Different internal fixators have their own biomechanical strengths and characteristics. The screw fixation has the advantage of being minimally invasive, but the fixation strength is limited, and it is mostly applied to Schatzker typeⅠfracture. For Schatzker Ⅰ-Ⅳ fracture, unilateral plate fixation can be used; for Schatzker Ⅴand Ⅵ fracture, bilateral plates fixation can be used to provide stronger fixation strength and avoid the stress concentration. The intramedullary nails fixation has the advantages of less trauma and less influence on the blood flow of the fracture end, but the fixation strength of the medial and lateral plateau is limited; so it is more suitable for tibial plateau fracture that involves only the metaphysis. Choosing the most appropriate internal fixation according to the patient's condition is still a major difficulty in the surgical treatment of tibial plateau fractures.
CONCLUSION
Each internal fixator has good fixation effect on tibial plateau fracture within the applicable range, and it is an important research direction to improve and innovate the existing internal fixator from various aspects, such as manufacturing process, material, and morphology.
Humans
;
Biomechanical Phenomena
;
Bone Plates
;
Fracture Fixation, Internal
;
Fracture Fixation, Intramedullary
;
Tibial Fractures/surgery*
;
Tibial Plateau Fractures
3.Osteotomy of non-core weight-bearing area of the lateral tibial plateau, reduction, and internal fixation in treatment of tibial plateau fractures involving posterolateral column collapse.
Xuan PEI ; Guodong WANG ; Shenglong QIAN ; Yipeng CHENG ; Zhixun FANG ; Xi KE ; Ximing LIU
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(4):410-416
OBJECTIVE:
To investigate the effectiveness of osteotomy of non-core weight-bearing area of the lateral tibial plateau, reduction, and internal fixation in the treatment of tibial plateau fractures involving posterolateral column collapse.
METHODS:
A clinical data of 23 patients with tibial plateau fractures involving posterolateral column collapse, who had undergone osteotomy of non-core weight-bearing area of the lateral tibial plateau, reduction, and internal fixation between January 2015 and June 2021, was retrospectively analyzed. There were 14 males and 9 females with an average age of 42.6 years ranging from 26 to 62 years. The causes of injury included traffic accident in 16 cases, falling from height in 5 cases, and other injuries in 2 cases. According to Schatzker classification, there were 15 cases of type Ⅴ and 8 cases of type Ⅵ. The time from injury to operation was 4-8 days with an average of 5.9 days. The operation time, intraoperative blood loss, fracture healing time, and complications were recorded. The depth of articular surface collapse of posterolateral column and posterior inclination angle (PSA) of the tibial plateau were compared before operation and at 2 days and 6 months after operation; fracture reduction of tibial plateau fracture was evaluated by Rasmussen anatomic score. The recovery of knee function was evaluated by Hospital for Special Surgery (HSS) score at 2 days and 6 months after operation.
RESULTS:
All 23 patients were completed the operation successfully. The operation time was 120-195 minutes, with an average of 152.8 minutes; the intraoperative blood loss was 50-175 mL, with an average of 109.5 mL. All patients were followed up 12-24 months, with an average of 16.7 months. One patient had superficial wound infection after operation, and the incision healed after dressing change; primary healing of incision of other patients was obtained. The fracture healing time was 12-18 weeks, with an average of 13.7 weeks. No failure of internal fixation, varus and valgus deformity of the knee joint, and instability of the knee joint was found at last follow-up. One patient developed joint stiffness and the range of motion of the knee joint was 10°-100°; the range of motion of the knee joint of other patients was 0°-125°. At 2 days and 6 months after operation, the depth of articular surface collapse of posterolateral column, PSA, and Rasmussen anatomic scores significantly improved when compared with those before operation ( P<0.05). There was no significant difference between the two postoperative time points ( P>0.05). The HSS score at 6 months after operation was significantly higher than that at 2 days after operation ( P<0.05).
CONCLUSION
For tibial plateau fractures involving posterolateral column collapse, reduction and internal fixation through osteotomy of non-core weight-bearing area of the lateral tibial plateau has the advantages of fully expose the posterolateral column fragment, good articular surface reduction, sufficient bone grafting, and fewer postoperative complications. It is beneficial to restore knee joint function and can be widely used in clinic.
Male
;
Female
;
Humans
;
Adult
;
Retrospective Studies
;
Blood Loss, Surgical
;
Tibial Plateau Fractures
;
Treatment Outcome
;
Bone Plates
;
Tibial Fractures/surgery*
;
Knee Joint
;
Fracture Fixation, Internal
;
Osteotomy
;
Weight-Bearing
4.Biomechanical effects of three internal fixation modes on femoral subtrochanteric spiral fractures in osteoporotic patients by finite element analysis.
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(6):688-693
OBJECTIVE:
The biomechanical characteristics of three internal fixation modes for femoral subtrochanteric spiral fracture in osteoporotic patients were compared and analyzed by finite element technology, so as to provide the basis for the optimization of fixation methods for femoral subtrochanteric spiral fracture.
METHODS:
Ten female patients with osteoporosis and femoral subtrochanteric spiral fractures caused by trauma, aged 65-75 years old, with a height of 160-170 cm and a body weight mass of 60-70 kg, were selected as the study subjects. The femur was scanned by spiral CT and a three-dimensional model of the femur was established by digital technology. The computer aided design models of proximal intramedullary nail (PFN), proximal femoral locking plate (PFLP), and the combination of the two (PFLP+PFN) were constructed under the condition of subtrochanteric fracture. Then the same load of 500 N was applied to the femoral head, and the stress distribution of the internal fixators, the stress distribution of the femur, and the displacement of femur after fracture fixation were compared and analyzed under the three finite element internal fixation modes, so as to evaluate the fixation effect.
RESULTS:
In the PFLP fixation mode, the stress of the plate was mainly concentrated in the main screw channel, the stresses of the different part of the plate were not equal, and gradually decreased from the head to the tail. In the PFN fixation mode, the stress was concentrated in the upper part of the lateral middle segment. In the PFLP+PFN fixation mode, the maximum stress appeared between the first and the second screws in the lower segment, and the maximum stress appeared in the lateral part of the middle segment of the PFN. The maximum stress of PFLP+PFN fixation mode was significantly higher than that of PFLP fixation mode, but significantly lower than that of PFN fixation mode ( P<0.05). In PFLP and PFN fixation modes, the maximum stress of femur appeared in the medial and lateral cortical bone of the middle femur and the lower side of the lowest screw. In PFLP+PFN fixation mode, the stress of femur concentrated in the medial and lateral of the middle femur. There was no significant difference in the maximum stress of femur among the three finite element fixation modes ( P>0.05). The maximum displacement occurred at the femoral head after three finite element fixation modes were used to fix subtrochanteric femoral fractures. The maximum displacement of femur in PFLP fixation mode was the largest, followed by PFN, and PFLP+PFN was the minimum, with significant differences ( P<0.05).
CONCLUSION
Under static loading conditions, the PFLP+PFN fixation mode produces the smallest maximum displacement when compared with the single PFN and PFLP fixation modes, but its maximum plate stress is greater than the single PFN and PFLP fixation mode, suggesting that the combination mode has higher stability, but the plate load is greater, and the possibility of fixation failure is higher.
Humans
;
Female
;
Aged
;
Finite Element Analysis
;
Biomechanical Phenomena
;
Fracture Fixation, Internal/methods*
;
Hip Fractures/surgery*
;
Bone Plates
;
Femur Head
;
Femoral Fractures/surgery*
5.Limited internal fixation combined with a hinged external fixator in treatment of peri-elbow bone infection.
Xiuan ZENG ; Jicheng HUANG ; Meng LI ; Qibing YANG ; Kejing WANG ; Zhenyang GAO ; Qiyuan WANG ; Xiangli LUO
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(6):694-699
OBJECTIVE:
To evaluate the effectiveness of limited internal fixation combined with a hinged external fixator in the treatment of peri-elbow bone infection.
METHODS:
The clinical data of 19 patients with peri-elbow bone infection treated with limited internal fixation combined with a hinged external fixator between May 2018 and May 2021 were retrospectively analyzed. There were 15 males and 4 females with an average age of 44.6 years (range, 28-61 years). There were 13 cases of distal humerus fractures and 6 cases of proximal ulna fractures. All the 19 cases were infected after internal fixation of fracture, and 2 cases were complicated with radial nerve injury. According to Cierny-Mader anatomical classification, 11 cases were type Ⅱ, 6 cases were type Ⅲ, and 2 cases were type Ⅳ. The duration of bone infection was 1-3 years. After primary debridement, the bone defect was (3.04±0.28) cm, and the antibiotic bone cement was implanted into the defect area, and the external fixator was installed; 3 cases were repaired with latissimus dorsi myocutaneous flap, and 2 cases were repaired with lateral brachial fascial flap. Bone defects repair and reconstruction were performed after 6-8 weeks of infection control. The wound healing was observed, and white blood cell (WBC), erythrocyte sedimentation rate (ESR), and C-reaction protein (CRP) were reexamined regularly after operation to evaluate the infection control. X-ray films of the affected limb were taken regularly after operation to observe the bone healing in the defect area. At last follow-up, the flexion and extension range of motion and the total range of motion of the elbow joint were observed and recorded, and compared with those before operation, and the function of the elbow joint was evaluated by Mayo score.
RESULTS:
All patients were followed up 12-34 months (mean, 26.2 months). The wounds healed in 5 cases after skin flap repair. Two cases of recurrent infection were effectively controlled by debridement again and replacement of antibiotic bone cement. The infection control rate was 89.47% (17/19) in the first stage. Two patients with radial nerve injury had poor muscle strength of the affected limb, and the muscle strength of the affected limb recovered from grade Ⅲ to about grade Ⅳ after rehabilitation exercise. During the follow-up period, there was no complication such as incision ulceration, exudation, bone nonunion, infection recurrence, or infection in the bone harvesting area. Bone healing time ranged from 16 to 37 weeks, with an average of 24.2 weeks. WBC, ESR, CRP, PCT, and elbow flexion, extension, and total range of motions significantly improved at last follow-up ( P<0.05). According to Mayo elbow scoring system, the results were excellent in 14 cases, good in 3 cases, and fair in 2 cases, and the excellent and good rate was 89.47%.
CONCLUSION
Limited internal fixation combined with a hinged external fixator in the treatment of the peri-elbow bone infection can effectively control infection and restore the function of the elbow joint.
Male
;
Female
;
Humans
;
Adult
;
Elbow
;
Elbow Joint/surgery*
;
Retrospective Studies
;
Bone Cements
;
Treatment Outcome
;
External Fixators
;
Fracture Fixation, Internal/methods*
;
Fractures, Bone
;
Range of Motion, Articular
6.Three-dimensional finite element model construction and biomechanical analysis of customized titanium alloy lunate prosthesis.
Bin WANG ; Xingbo CAI ; Yue ZHANG ; Bihuan ZHANG ; Yongqing XU
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(7):821-826
OBJECTIVE:
To design customized titanium alloy lunate prosthesis, construct three-dimensional finite element model of wrist joint before and after replacement by finite element analysis, and observe the biomechanical changes of wrist joint after replacement, providing biomechanical basis for clinical application of prosthesis.
METHODS:
One fresh frozen human forearm was collected, and the maximum range of motions in flexion, extension, ulnar deviation, and radialis deviation tested by cortex motion capture system were 48.42°, 38.04°, 35.68°, and 26.41°, respectively. The wrist joint data was obtained by CT scan and imported into Mimics21.0 software and Magics21.0 software to construct a wrist joint three-dimensional model and design customized titanium alloy lunate prosthesis. Then Geomagic Studio 2017 software and Solidworks 2017 software were used to construct the three-dimensional finite element models of a normal wrist joint (normal model) and a wrist joint with lunate prosthesis after replacement (replacement model). The stress distribution and deformation of the wrist joint before and after replacement were analyzed for flexion at and 15°, 30°, 48.42°, extension at 15°, 30°, and 38.04°, ulnar deviation at 10°, 20°, and 35.68°, and radial deviation at 5°, 15°, and 26.41° by the ANSYS 17.0 finite element analysis software. And the stress distribution of lunate bone and lunate prosthesis were also observed.
RESULTS:
The three-dimensional finite element models of wrist joint before and after replacement were successfully constructed. At different range of motion of flexion, extension, ulnar deviation, and radial deviation, there were some differences in the number of nodes and units in the grid models. In the four directions of flexion, extension, ulnar deviation, and radial deviation, the maximum deformation of wrist joint in normal model and replacement model occurred in the radial side, and the values increased gradually with the increase of the range of motion. The maximum stress of the wrist joint increased gradually with the increase of the range of motion, and at maximum range of motion, the stress was concentrated on the proximal radius, showing an overall trend of moving from the radial wrist to the proximal radius. The maximum stress of normal lunate bone increased gradually with the increase of range of motion in different directions, and the stress position also changed. The maximum stress of lunate prosthesis was concentrated on the ulnar side of the prosthesis, which increased gradually with the increase of the range of motion in flexion, and decreased gradually with the increase of the range of motion in extension, ulnar deviation, and radialis deviation. The stress on prosthesis increased significantly when compared with that on normal lunate bone.
CONCLUSION
The customized titanium alloy lunate prosthesis does not change the wrist joint load transfer mode, which provided data support for the clinical application of the prosthesis.
Humans
;
Lunate Bone/surgery*
;
Finite Element Analysis
;
Titanium
;
Wrist Joint/surgery*
;
Artificial Limbs
;
Range of Motion, Articular
;
Biomechanical Phenomena
7.Correction of tibial multiplanar deformities using single Taylor external fixator combined with biplanar osteotomy.
Shaofeng JIAO ; Sihe QIN ; Zhenjun WANG ; Yue GUO ; Hongsheng XU ; Zhijie LIU ; Jianwen CHEN
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(7):839-845
OBJECTIVE:
To investigate the effectiveness of single Taylor external fixator combined with biplanar osteotomy on correction of tibial multiplanar deformities.
METHODS:
Between October 2016 and December 2021, 11 patients with tibial multiplanar deformities (20 sides) were treated with single Taylor external fixator and biplanar osteotomy. Of them, 4 were male and 7 were female; the average age ranged from 13 to 33 years (mean, 21.9 years). Diagnosis included rickets severe genu varum deformity (7 cases, 14 sides), rickets severe genu valgum deformity (2 cases, 4 sides), multiple osteochondromatosis calf deformity (1 case, 1 side), neurofibromatosis medial lower leg anterior arch deformity with short of leg (1 case, 1 side). After fibular osteotomy and tibial multiplanar osteotomy, a Taylor external fixator was installed. After operation, the deformities were corrected successively and fixed completely. The osteotomy healed, then the external fixator was removed. Before operation and at 12 months after operation, the full-length X-ray films were taken. The leg-length discrepancy, medial proximal tibial angle (MPTA), lateral distal tibial angle (LDTA), posterior proximal tibial angle (PPTA), anterior distal tibial angle (ADTA), and tibial rotation angle were measured. The degree of lower limb deformity was scored with reference to a customized tibial mechanical axis scoring table.
RESULTS:
Osteotomy was successfully completed without neurovascular injury and other complications. The external fixator was adjusted for 28-46 days, with an average of 37 days, and the external fixator was worn for 136-292 days, with an average of 169 days. Mild needle infection during the fixation period occurred in 3 sides, refracture at the distal tibial osteotomy in 1 side after removing the external fixator, and nonunion of the distal fibular osteotomy in 1 side. All patients were followed up 369-397 days (mean, 375 days). At 12 months after operation, the lower limb discrepancy decreased, but there was no significant difference ( P>0.05). MPTA, LDTA, PPTA, ADTA, and tibial rotation angle improved, and the differences in LDTA, ADTA, and tibial rotation angle were significant ( P<0.05). The score of lower limb deformity was significantly higher than that before operation ( P<0.05), and the results were excellent in 9 sides, good in 8 sides, fair in 3 sides, with the excellent and good rate of 85%.
CONCLUSION
Single Taylor external fixator combined with biplanar osteotomy is effective in the correction of tibial multiplanar deformities.
Humans
;
Male
;
Female
;
Adolescent
;
Young Adult
;
Adult
;
Tibia/surgery*
;
Osteotomy/methods*
;
Rickets
;
External Fixators
;
Retrospective Studies
;
Treatment Outcome
8.Treatment analysis of complex Schatzker type Ⅳ tibial plateau fractures.
Xiao-Bin CHEN ; Meng LU ; Ben XIAO ; Dao-Jing QIU ; Yuan-Ming HE ; Xue-Jun LI
China Journal of Orthopaedics and Traumatology 2023;36(4):308-312
OBJECTIVE:
To explore treatment strategy for complex Schatzker Ⅳ tibial plateau fracture.
METHODS:
Forty-one patients with complex Schatzker type Ⅳ tibial plateau fractures were treated from January 2016 to January 2021, including 28 males and 13 females, aged from 19 to 65 years old with an average of (35.3±19.8) years old. Individualized treatment plan was developed according to preoperative imaging characteristics, medial surgical approach was mainly combined with other auxiliary incisions. Posteromedial inverted L approach was used in 18 patients, posteromedial approach and anterolateral extended approach in 19 patients, and posteromedial approach with anterolateral and lateral condylar osteotomy in 4 patients. Articular surface and facture healing were observed, range of knee joint motion was measured at 12 months after opertaion, and function of knee joint was evaluated by Lysholm scoring system.
RESULTS:
Forty-one patients were followed up for 12 to 26 months with an average of (13.3±6.8) months. Twenty-nine patients and 10 patients were obtained complete fracture healing at 6 and 12 months after operation respectively, and fracture healing time was 4 to 13 months with an average of (5.0±3.7) months. Two patients occurred posterior medial internal fixation failure and varus deformity of knee joint, and the fracture healed and varus deformity was corrected after the second operation. Range of knee joint motion was (118±29) °, and Lysholm score was(83.0±16.0) points.
CONCLUSION
Individualized treatment should be reasonably selected for complex Schatzker Ⅳ tibial plateau fractures, the characteristics of lateral plateau fractures are an important reference for selecting surgical approaches, the effective fixation of posteromedial bone blocks should be pay full attention, and the overall treatment results are satisfied.
Male
;
Female
;
Humans
;
Young Adult
;
Adult
;
Middle Aged
;
Aged
;
Adolescent
;
Tibial Plateau Fractures
;
Bone Plates
;
Tibial Fractures/surgery*
;
Treatment Outcome
;
Knee Joint/surgery*
;
Fracture Fixation, Internal/methods*
;
Retrospective Studies
9.Double-column Die-punch fractures of distal radius treated with butterfly plate fixation via Henry approach.
Hai-Bo XIA ; Jun LAN ; Li-Qing JIANG ; Hua-Fei YANG ; Xiao-Hui NIU
China Journal of Orthopaedics and Traumatology 2023;36(4):376-380
OBJECTIVE:
To explore clinical effect of open reduction and internal fixation with Henry's approach butterfly plate in treating double-column Die-punch fractures of distal radius.
METHODS:
From January 2018 to June 2021, 26 patients with double-column Die-column distal radius were treated with open reduction and internal fixation through Henry's surgical approach and using distal radius volar column plate(butterfly plate), including 14 males and 12 females, aged from 20 to 75 years old with an average age of (44.2±3.4) years old. Postopertaive complications were observed, Gartland-Werley score at 12 months after opertaion was used to evaluate wrist joint function.
RESULTS:
All 26 patients were followed up from 10 to 18 months with an average of(13.4±0.8) months. All fractures were obtained fracture union, the time ranged from 8.5 to 15.8 weeks with an average of (11.4±0.5) weeks. All incisions healed at stageⅠwithout infection, nerve injury and internal fixation failure occurred. Postoperative Gartland-Werley score at 12 months was (3.65±0.36), and 16 patients got excellent result, 8 good and 2 moderate.
CONCLUSION
Open reduction and internal fixation with butterfly plate for the treatment of double-column Die-punch fractures of the distal radius through volar Henry approach could obtain satisfactory clinical outcomes.
Adult
;
Aged
;
Animals
;
Female
;
Humans
;
Male
;
Middle Aged
;
Young Adult
;
Bone Plates
;
Fracture Fixation, Internal/methods*
;
Radius/surgery*
;
Radius Fractures/surgery*
;
Range of Motion, Articular
;
Treatment Outcome
;
Wrist Joint
10.Percutaneous minimally invasive osteotomy with 8-shaped bandage and hallux valgus splint fixation for the treatment of moderate hallux valgus.
Bao-Chen TAO ; Kai YANG ; Ying-Lin ZHAO ; Jun ZHAO ; Tie-Bing SONG
China Journal of Orthopaedics and Traumatology 2023;36(4):381-385
OBJECTIVE:
To observe clinical effect of percutaneous minimally invasive osteotomy with 8-shaped bandage and hallux valgus splint fixation in treating moderate hallux valgus.
METHODS:
Totally 23 patients with moderate hallux valgus were treated with percutaneous minimally invasive osteotomy with 8-shaped bandage and hallux valgus splint fixation from August 2019 to January 2021, and 1 patient was loss to follow-up, and finally 22 patients(30 feet) were included, 4 males (6 feet) and 18 females(24 feet), aged from 27 to 66 years old with an average of(50.59±11.95) years old. Hallux valgus angle (HVA), intermetatarsal angle (IMA), metatarsal span (the distance between the first and the fifth metatarsal bones), changed of soft tissue width, American Orthopaedic Foot and Ankle Society(AOFAS) score, and Visual Analogue Scale (VAS) were collected and compared before operation and 6 months after operation.
RESULTS:
Twenty-two patients were followed up from 5.7 to 6.4 months with an average of (6.13±0.85) months. The first metatarsal osteotomy of patients were obtained bone union, and deformity of the toes was corrected. Complications such as avascular necrosis of metatarsal head and transfer metatarsalgia were not occurred. Postoperative HVA, IMA, metatarsal span, soft tissue width, VAS, AOFAS score at 6 months were significantly improved compared with pre-operation (P<0.01). According to AOFAS score at 6 months after operation, 10 feet were excellent, 18 good and 2 poor. Two feet with poor were excellent after prolonged 8-shaped bandage and hallux valgus splint fixation time.
CONCLUSION
Percutaneous minimally invasive osteotomy with 8-shaped bandage and hallux valgus splint fixation for the treatment of moderate hallux valgus could better correct deformity of hallux valgus, relieve foot symptoms, good recovery of postoperative function, and has a significant clinical efficacy.
Male
;
Female
;
Humans
;
Adult
;
Middle Aged
;
Aged
;
Hallux Valgus/diagnostic imaging*
;
Splints
;
Radiography
;
Bunion
;
Treatment Outcome
;
Metatarsal Bones/surgery*
;
Osteotomy
;
Bandages

Result Analysis
Print
Save