1.Mandibular advancement with clear aligners and functional appliances in the treatment of skeletal ClassⅡmalocclusion: a systematic review and meta-analysis.
Lei YU ; Ziwei LI ; Fujia KANG ; Songqing WANG ; Zunxuan XIE ; Xianchun ZHU
West China Journal of Stomatology 2023;41(3):305-314
OBJECTIVES:
This study aimed to conduct a meta-analysis of the efficacy of mandibular advance clear alig-ners with traditional functional appliances as the control group.
METHODS:
PubMed, Web of Science, Embase, Cochrane Library, China Biomedical Abstracts Database, China Knowledge Network Database, Wanfang Database, and Weipu Database were used in this study. The two groups of researchers screened the literature and extracted data based on the inclusion and exclusion criteria established by PICOS entries, and used the ROBINS-I scale for quality evaluation. Revman 5.4 and Stata 17.0 software were used for meta-analysis.
RESULTS:
Nine clinical controlled trials were included in this study with a total sample size of 283 cases. No significant difference was found in SNA, SNB, ANB, Go-Pog, U1-SN, Overjet, and other aspects between the invisible group and the traditional group in the treatment of skeletal class Ⅱ ma-locclusion patients; there was a 0.90° difference in mandibular plane angle between the two groups; the growth of the mandibular ramus (Co-Go) in the traditional group was 1.10 mm more than that in the invisible group; the lip inclination of the lower teeth in the invisible group was better controlled, 1.94° less than that in the control group.
CONCLUSIONS
The invisible group can better control the lip inclination of the mandibular anterior teeth when guiding the mandible. Furthermore, the mandibular plane angle (MP-SN) can remain unchanged, but the growth of the mandibular ramus is not as good as the traditional group, and auxiliary measures should be taken to improve it in clinical practice.
Humans
;
Malocclusion, Angle Class II/therapy*
;
Mandibular Advancement
;
Orthodontics, Corrective
;
Orthodontic Appliances, Functional
;
Mandible
;
Orthodontic Appliances, Removable
;
Cephalometry
2.Three-dimensional finite element study of mandibular first molar distalization with clear aligner.
Fujia KANG ; Lei YU ; Qi ZHANG ; Xinpeng LI ; Zhiqiang HU ; Xianchun ZHU
West China Journal of Stomatology 2023;41(4):405-413
OBJECTIVES:
This study aimed to construct the finite element model of the mandibular first molar with the invisible appliance and explore the dentition movement characteristics of the mandibular first molar when using micro-implant anchorage and different initial positions of the first molar.
METHODS:
Models of the mandible, tooth, periodontal membrane, and invisible appliance were constructed using cone beam computed tomography (CBCT) data. The two groups were divided into the non-anchorage group and the micro-implant group (between the roots of the first molar and the second molar) based on whether the elastic traction of the micro-implant was assisted or not. The two groups were divided into the following conditions based on the starting position of the first molar: Working condition 1: the distance between the first molar and the second premolar was 0 mm; working condition 2: the distance between the first molar and the second premolar was 1 mm; working condition 3: the distance between the first molar and the second premolar was 2 mm; working condition 4: the distance between the first molar and the second premolar was 3 mm. The data characte-ristics of total displacement and displacement in each direction of dentition were analyzed.
RESULTS:
In the non-ancho-rage group, all the other teeth showed reverse movement except for the first molar which was moved distally. Meanwhile, in the micro-implant group, except for a small amount of mesial movement of the second molar in wor-king condition 1, the whole dentition in other working conditions presented distal movement and anterior teeth showed lingual movement, among which the distal displacement of the first molar in working condition 4 was the largest. With the change of the initial position of the first molar to the distal, the movement of the first molar to the distal, the premolar to the mesial, and the anterior to the lip increased, while the movement of the second molar to the mesial decreased.
CONCLUSIONS
The micro-implant can effectively protect the anterior anchorage, increase the expression rate of molar distancing, and avoid the round-trip movement of the second molar. The initial position of the first molar movement is related to the amount of distancing and the remaining tooth movement.
Finite Element Analysis
;
Molar
;
Bicuspid
;
Periodontal Ligament
;
Tooth Movement Techniques/methods*
;
Orthodontic Appliances, Removable
3.Meta-analysis of condylar changes produced by a Twin-block appliance in Class Ⅱ malocclusion.
Yulin LI ; Jingchen XU ; Xiaoge JIANG ; Song CHEN
West China Journal of Stomatology 2023;41(4):463-470
OBJECTIVES:
To evaluate the effects of a Twin-block appliance on the condyles of patients with ClassⅡmalocclusion by conducting a systematic review and a Meta-analysis.
METHODS:
Pubmed, Embase, Cochrane Library, Chinese BioMedical Literature Database, China National Knowledge Infrastructure, and VIP Database were electronically searched. Randomized controlled trials, controlled clinical trials, and single-arm trials on condylar changes produced by a Twin-block appliance in patients with ClassⅡmalocclusion were included. Two reviewers independently extracted and assessed the risk of bias. Meta-analyses were conducted with Review Manager 5.3.
RESULTS:
Eight studies were included; among which, seven were of high quality. After treatment with a twin block appliance, condyles moved anteriorly. The anterior joint spaces decreased (P<0.000 01), whereas the posterior spaces increased (P<0.000 01). The superior spaces were not changed (P=0.11). Moreover, a significant difference was observed in the increase of the condylar space index (P<0.000 01). After treatment, the anteroposterior diameters of the condyles and condylar height increased (P=0.000 2 and P<0.000 01, respectively). By contrast, no significant changes were discovered in the medial external diameters of the condyles (P=0.42).
CONCLUSIONS
A Twin-block appliance can promote the growth of a condyle in the posterior and upper direction and move it forward in favor of the correction of Class Ⅱ malocclusion.
Humans
;
Malocclusion, Angle Class II/therapy*
;
Temporomandibular Joint
;
Bone and Bones
;
China
;
Orthodontic Appliances, Functional
;
Cephalometry
4.Timely and appropriately performing early orthodontic treatment.
Chinese Journal of Stomatology 2022;57(8):789-793
In recent years, the early orthodontic treatment of malocclusion has become a hot issue in the field of orthodontics. Some new phenomena and new problems that have emerged require in-depth analysis and discussion, and need to be given correct guidance and norms. Malocclusion refers to the deformities of teeth, jaws, and craniofacial bones caused by genetic and environmental factors during growth and development. Based on the accurate judgment of the etiology and diagnosis, choosing the right time and suitable indications, with the advantage of growth and development, the most suitable appliance can be selected in the early stage of malocclusion to fix malocclusion, and to effectively prevent and block the formation and development of malocclusion. This article will discuss how to timely and appropriately carry out the early prevention and treatment of malocclusion with six aspects, including methods of performing early orthodontic treatment, the basis and guarantee of early orthodontic treatment, correctly understanding early orthodontic treatment, the issues that should be paid attention to in carrying out early orthodontic treatment, actively advocating multidisciplinary cooperation during early orthodontic treatment and understanding face management in a serious way.
Dental Care
;
Humans
;
Malocclusion/therapy*
;
Malocclusion, Angle Class II/therapy*
;
Orthodontic Appliances, Functional
;
Orthodontics, Corrective/methods*
5.Early orthodontic treatment in deciduous dentition.
Chinese Journal of Stomatology 2022;57(8):800-804
Early orthodontic treatment refers to the orthodontic treatment of dental-maxillofacial deformities in the early deciduous or mixed dentition. More and more attentions has been paid to early orthodontic treatment. Many kinds of orthodontic appliances are emerging on the market with the rapid development of the orthodontic technology. At the same time, problems and increased risks have followed in early orthodontic treatment. The contents of the article include the establishment of deciduous occlusion and the characteristics of the deciduous dentition, the orthodontic principles of different stages of deciduous dentition, the oral bad habits during the deciduous dentition and the risk control of early orthodontic treatment.
Dental Occlusion
;
Dentition, Mixed
;
Humans
;
Malocclusion/therapy*
;
Orthodontic Appliances
;
Tooth, Deciduous
6.Accuracy of progress assessment with clear aligners.
Bo LI ; Yimeng XU ; Ruiying SHI ; Yirong HU ; Siying LIU ; Zexu GU
West China Journal of Stomatology 2022;40(6):698-703
OBJECTIVES:
This study aimed to investigate the accuracy of model superimposition and automatic analysis for upper and lower dentition widths in iTero Progress Assessment during the clear aligner process.
METHODS:
Nineteen cases were included in this retrospective case control study. Pretreatment dental cast (T0) and post treatment dental cast after staged treatment (T1) were available for three-dimensional (3D) model superimposition. The movements of maxillary teeth in the horizontal plane (cross section) after staged treatment and the widths of upper and lower dentitions were measured by 3D model superimposition in real world and iTero Progress Assessment. The data collected from the two methods were compared.
RESULTS:
The movements [Median (upper and lower quartiles)] of maxillary teeth in the horizontal plane after staged treatment were 2.31 (1.59, 3.22) and 1.79 (1.21, 3.03) mm in iTero Progress Assessment and 3D model analysis, respectively. Significant difference was observed between the two groups (P<0.05). In the measurement of upper and lower dentition width, four indicators were measured, including intercanine width upper, intermolar width upper, intercanine width lower, and intermolar width lower. Before treatment, the measurement of iTero Progress Assessment were (35.78±2.49), (56.21±2.51), (27.43±1.38), (52.26±2.91) mm, respectively, and actual measurement were (35.77±2.53), (56.17±2.47), (27.40±1.41), (52.30±2.86) mm, respectively, without significant difference (P>0.05). After stage treatment, the measurement of iTero Progress Assessment were (37.37±2.86), (57.76±2.56), (28.89±2.00), (54.16±2.19) mm, respectively, and actual measurement were (37.29±2.94), (57.71±2.63), (28.88±2.05), (54.01±2.15) mm, respectively, and there was no significant difference (P>0.05).
CONCLUSIONS
The data from iTero Progress Assessment did not coincide with the model superimposition results with palate as reference. The accuracy of model superimposition in iTero Progress Assessment needs further investigation, whereas the arch width analysis is accurate. Therefore, iTero Progress Assessment results should be interpreted with caution by orthodontists in clinical applications.
Case-Control Studies
;
Cuspid
;
Dental Arch
;
Orthodontic Appliances, Removable
;
Retrospective Studies
;
Humans
7.Guidelines for clear aligner orthodontic treatment (2021).
Chinese Journal of Stomatology 2021;56(10):983-988
The content of the guidelines is based on monographs and literatures on the clear aligner orthodontic treatment in the past five years, and the clinical consensus of all the members of Expert Group for Writing Project of Clear Aligner Technology. This guidelines provide guidance and reference for orthodontists who want carry out clear aligner orthodontic treatment in three parts: overview, diagnosis and design, and common treatment strategies. In the part of the overview, the instructions for the preparation of this guide were described. The requirements for practitioners providing clear aligner orthodontic treatment were put forward, and the risks associated with clear aligner orthodontic treatment were suggested. In the part of diagnosis and design, the indications and selection of clear aligner orthodontic treatment were defined. The requirements of collecting data in orthodontic cases and the design process of clear aligner orthodontic treatment were also explained. The present common treatment strategies for clear aligner orthodontic treatment were summarized in the third part of the guidelines. The elaboration of the treatment methods such as distalization of molar, interproximal enamel reduction and stepwise tooth movement were explained.
Dental Care
;
Humans
;
Molar
;
Orthodontic Appliances, Removable
;
Tooth Movement Techniques
8.Efficacy of mandibular molar distalization by clear aligner treatment.
Dongxue WU ; Yunshan ZHAO ; Meng MA ; Qianqian ZHANG ; He LEI ; Yaqian WANG ; Yueshan LI ; Xi CHEN
Journal of Central South University(Medical Sciences) 2021;46(10):1114-1121
OBJECTIVES:
At present, the research on clear aligner of molar distalization mainly focuses on the upper jaw, while the research on mandibular molars is few.This study aims to evaluate the therapeutic effect of mandibular molars distalization with clear aligner via cone beam CT (CBCT) and Dolphin software.
METHODS:
Twenty cases of mandibular molars with clear aligner were included according to the inclusion and exclusion criteria. CBCT was taken before treatment (T0) and when the first molar was moved in place (T1). Dolphin software was used to measure the effectiveness of molar distalization. Three-dimensional changes in direction and the impact on the incisors and facial soft and hard tissues were evaluated.
RESULTS:
The effective rates of crown and root distalization of the second and first mandibular molars were 74%, 49%, and 71%, 47%, respectively. The second and first molars were both the distal buccal cusp with the largest distalization [(2.15 ± 0.91) mm and (1.85±1.09) mm], respectively, with significant difference between the T0 and T1 (
CONCLUSIONS
Clear aligner can effectively move mandibular molars farther, the crown is more effective than the root, and it is tilted. The second mandibular molar is more effective than the first mandibular molar in its distant displacement and three-dimensional changes. Molar distalization causes minor changes in mandibular incisors and facial soft and hard tissues.
Cephalometry
;
Maxilla
;
Molar
;
Orthodontic Appliances, Removable
;
Tooth Movement Techniques
9.Reader's Forum.
The Korean Journal of Orthodontics 2019;49(1):1-2
No abstract available.
Malocclusion, Angle Class II
;
Orthodontic Appliance Design
;
Orthodontic Appliances
;
Tooth Movement Techniques
10.Intrusion of the extruded maxillary central incisor using skeletal anchorage system and unilateral segmental intrusion arch
Eun Young KWON ; Young Jae BAEK ; Soo Byung PARK ; Seong sik KIM ; Yong il KIM ; Youn kyung CHOI
Journal of Dental Rehabilitation and Applied Science 2019;35(3):180-190
Patients who have a moderate periodontitis with pathologic tooth migration of maxillary incisors, it is necessary not only periodontal treatment for reduce periodontal inflammation, but also orthodontic treatment to teeth repositioning. For orthodontic treatment, it is necessary to apply less force and careful considerations of the center of resistance of the tooth and optimal force of tooth movement. At this time, the segmental arch applied only to the target teeth, is more effective and predictable, because applied force and direction can be controlled. In addition, to design the orthodontic appliance that can prevent the unwanted tooth movement that used as an anchorage is important. In recent years, various types of skeletal anchorage system have been used for preventing loss of the anchorage. We reported the patient who had extruded maxillary central incisor due to pathologic tooth migration, treated by a successful periodontal-orthodontic multidisciplinary treatment using an orthodontic appliance designed to apply less traumatic force and reduce an anchorage loss.
Humans
;
Incisor
;
Inflammation
;
Orthodontic Appliance Design
;
Orthodontic Appliances
;
Orthodontic Wires
;
Periodontitis
;
Tooth
;
Tooth Migration
;
Tooth Movement

Result Analysis
Print
Save
E-mail