1.Performance of Digital Mammography-Based Artificial Intelligence Computer-Aided Diagnosis on Synthetic Mammography From Digital Breast Tomosynthesis
Kyung Eun LEE ; Sung Eun SONG ; Kyu Ran CHO ; Min Sun BAE ; Bo Kyoung SEO ; Soo-Yeon KIM ; Ok Hee WOO
Korean Journal of Radiology 2025;26(3):217-229
Objective:
To test the performance of an artificial intelligence-based computer-aided diagnosis (AI-CAD) designed for fullfield digital mammography (FFDM) when applied to synthetic mammography (SM).
Materials and Methods:
We analyzed 501 women (mean age, 57 ± 11 years) who underwent preoperative mammography and breast cancer surgery. This cohort consisted of 1002 breasts, comprising 517 with cancer and 485 without. All patients underwent digital breast tomosynthesis (DBT) and FFDM during the preoperative workup. The SM is routinely reconstructed using DBT. Commercial AI-CAD (Lunit Insight MMG, version 1.1.7.2) was retrospectively applied to SM and FFDM to calculate the abnormality scores for each breast. The median abnormality scores were compared for the 517 breasts with cancer using the Wilcoxon signed-rank test. Calibration curves of abnormality scores were evaluated. The discrimination performance was analyzed using the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity using a 10% preset threshold. Sensitivity and specificity were further analyzed according to the mammographic and pathological characteristics.The results of SM and FFDM were compared.
Results:
AI-CAD demonstrated a significantly lower median abnormality score (71% vs. 96%, P < 0.001) and poorer calibration performance for SM than for FFDM. SM exhibited lower sensitivity (76.2% vs. 82.8%, P < 0.001), higher specificity (95.5% vs.91.8%, P < 0.001), and comparable AUC (0.86 vs. 0.87, P = 0.127) than FFDM. SM showed lower sensitivity than FFDM in asymptomatic breasts, dense breasts, ductal carcinoma in situ, T1, N0, and hormone receptor-positive/human epidermal growth factor receptor 2-negative cancers but showed higher specificity in non-cancerous dense breasts.
Conclusion
AI-CAD showed lower abnormality scores and reduced calibration performance for SM than for FFDM.Furthermore, the 10% preset threshold resulted in different discrimination performances for the SM. Given these limitations, off-label application of the current AI-CAD to SM should be avoided.
2.Performance of Digital Mammography-Based Artificial Intelligence Computer-Aided Diagnosis on Synthetic Mammography From Digital Breast Tomosynthesis
Kyung Eun LEE ; Sung Eun SONG ; Kyu Ran CHO ; Min Sun BAE ; Bo Kyoung SEO ; Soo-Yeon KIM ; Ok Hee WOO
Korean Journal of Radiology 2025;26(3):217-229
Objective:
To test the performance of an artificial intelligence-based computer-aided diagnosis (AI-CAD) designed for fullfield digital mammography (FFDM) when applied to synthetic mammography (SM).
Materials and Methods:
We analyzed 501 women (mean age, 57 ± 11 years) who underwent preoperative mammography and breast cancer surgery. This cohort consisted of 1002 breasts, comprising 517 with cancer and 485 without. All patients underwent digital breast tomosynthesis (DBT) and FFDM during the preoperative workup. The SM is routinely reconstructed using DBT. Commercial AI-CAD (Lunit Insight MMG, version 1.1.7.2) was retrospectively applied to SM and FFDM to calculate the abnormality scores for each breast. The median abnormality scores were compared for the 517 breasts with cancer using the Wilcoxon signed-rank test. Calibration curves of abnormality scores were evaluated. The discrimination performance was analyzed using the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity using a 10% preset threshold. Sensitivity and specificity were further analyzed according to the mammographic and pathological characteristics.The results of SM and FFDM were compared.
Results:
AI-CAD demonstrated a significantly lower median abnormality score (71% vs. 96%, P < 0.001) and poorer calibration performance for SM than for FFDM. SM exhibited lower sensitivity (76.2% vs. 82.8%, P < 0.001), higher specificity (95.5% vs.91.8%, P < 0.001), and comparable AUC (0.86 vs. 0.87, P = 0.127) than FFDM. SM showed lower sensitivity than FFDM in asymptomatic breasts, dense breasts, ductal carcinoma in situ, T1, N0, and hormone receptor-positive/human epidermal growth factor receptor 2-negative cancers but showed higher specificity in non-cancerous dense breasts.
Conclusion
AI-CAD showed lower abnormality scores and reduced calibration performance for SM than for FFDM.Furthermore, the 10% preset threshold resulted in different discrimination performances for the SM. Given these limitations, off-label application of the current AI-CAD to SM should be avoided.
3.Performance of Digital Mammography-Based Artificial Intelligence Computer-Aided Diagnosis on Synthetic Mammography From Digital Breast Tomosynthesis
Kyung Eun LEE ; Sung Eun SONG ; Kyu Ran CHO ; Min Sun BAE ; Bo Kyoung SEO ; Soo-Yeon KIM ; Ok Hee WOO
Korean Journal of Radiology 2025;26(3):217-229
Objective:
To test the performance of an artificial intelligence-based computer-aided diagnosis (AI-CAD) designed for fullfield digital mammography (FFDM) when applied to synthetic mammography (SM).
Materials and Methods:
We analyzed 501 women (mean age, 57 ± 11 years) who underwent preoperative mammography and breast cancer surgery. This cohort consisted of 1002 breasts, comprising 517 with cancer and 485 without. All patients underwent digital breast tomosynthesis (DBT) and FFDM during the preoperative workup. The SM is routinely reconstructed using DBT. Commercial AI-CAD (Lunit Insight MMG, version 1.1.7.2) was retrospectively applied to SM and FFDM to calculate the abnormality scores for each breast. The median abnormality scores were compared for the 517 breasts with cancer using the Wilcoxon signed-rank test. Calibration curves of abnormality scores were evaluated. The discrimination performance was analyzed using the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity using a 10% preset threshold. Sensitivity and specificity were further analyzed according to the mammographic and pathological characteristics.The results of SM and FFDM were compared.
Results:
AI-CAD demonstrated a significantly lower median abnormality score (71% vs. 96%, P < 0.001) and poorer calibration performance for SM than for FFDM. SM exhibited lower sensitivity (76.2% vs. 82.8%, P < 0.001), higher specificity (95.5% vs.91.8%, P < 0.001), and comparable AUC (0.86 vs. 0.87, P = 0.127) than FFDM. SM showed lower sensitivity than FFDM in asymptomatic breasts, dense breasts, ductal carcinoma in situ, T1, N0, and hormone receptor-positive/human epidermal growth factor receptor 2-negative cancers but showed higher specificity in non-cancerous dense breasts.
Conclusion
AI-CAD showed lower abnormality scores and reduced calibration performance for SM than for FFDM.Furthermore, the 10% preset threshold resulted in different discrimination performances for the SM. Given these limitations, off-label application of the current AI-CAD to SM should be avoided.
4.Performance of Digital Mammography-Based Artificial Intelligence Computer-Aided Diagnosis on Synthetic Mammography From Digital Breast Tomosynthesis
Kyung Eun LEE ; Sung Eun SONG ; Kyu Ran CHO ; Min Sun BAE ; Bo Kyoung SEO ; Soo-Yeon KIM ; Ok Hee WOO
Korean Journal of Radiology 2025;26(3):217-229
Objective:
To test the performance of an artificial intelligence-based computer-aided diagnosis (AI-CAD) designed for fullfield digital mammography (FFDM) when applied to synthetic mammography (SM).
Materials and Methods:
We analyzed 501 women (mean age, 57 ± 11 years) who underwent preoperative mammography and breast cancer surgery. This cohort consisted of 1002 breasts, comprising 517 with cancer and 485 without. All patients underwent digital breast tomosynthesis (DBT) and FFDM during the preoperative workup. The SM is routinely reconstructed using DBT. Commercial AI-CAD (Lunit Insight MMG, version 1.1.7.2) was retrospectively applied to SM and FFDM to calculate the abnormality scores for each breast. The median abnormality scores were compared for the 517 breasts with cancer using the Wilcoxon signed-rank test. Calibration curves of abnormality scores were evaluated. The discrimination performance was analyzed using the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity using a 10% preset threshold. Sensitivity and specificity were further analyzed according to the mammographic and pathological characteristics.The results of SM and FFDM were compared.
Results:
AI-CAD demonstrated a significantly lower median abnormality score (71% vs. 96%, P < 0.001) and poorer calibration performance for SM than for FFDM. SM exhibited lower sensitivity (76.2% vs. 82.8%, P < 0.001), higher specificity (95.5% vs.91.8%, P < 0.001), and comparable AUC (0.86 vs. 0.87, P = 0.127) than FFDM. SM showed lower sensitivity than FFDM in asymptomatic breasts, dense breasts, ductal carcinoma in situ, T1, N0, and hormone receptor-positive/human epidermal growth factor receptor 2-negative cancers but showed higher specificity in non-cancerous dense breasts.
Conclusion
AI-CAD showed lower abnormality scores and reduced calibration performance for SM than for FFDM.Furthermore, the 10% preset threshold resulted in different discrimination performances for the SM. Given these limitations, off-label application of the current AI-CAD to SM should be avoided.
5.Performance of Digital Mammography-Based Artificial Intelligence Computer-Aided Diagnosis on Synthetic Mammography From Digital Breast Tomosynthesis
Kyung Eun LEE ; Sung Eun SONG ; Kyu Ran CHO ; Min Sun BAE ; Bo Kyoung SEO ; Soo-Yeon KIM ; Ok Hee WOO
Korean Journal of Radiology 2025;26(3):217-229
Objective:
To test the performance of an artificial intelligence-based computer-aided diagnosis (AI-CAD) designed for fullfield digital mammography (FFDM) when applied to synthetic mammography (SM).
Materials and Methods:
We analyzed 501 women (mean age, 57 ± 11 years) who underwent preoperative mammography and breast cancer surgery. This cohort consisted of 1002 breasts, comprising 517 with cancer and 485 without. All patients underwent digital breast tomosynthesis (DBT) and FFDM during the preoperative workup. The SM is routinely reconstructed using DBT. Commercial AI-CAD (Lunit Insight MMG, version 1.1.7.2) was retrospectively applied to SM and FFDM to calculate the abnormality scores for each breast. The median abnormality scores were compared for the 517 breasts with cancer using the Wilcoxon signed-rank test. Calibration curves of abnormality scores were evaluated. The discrimination performance was analyzed using the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity using a 10% preset threshold. Sensitivity and specificity were further analyzed according to the mammographic and pathological characteristics.The results of SM and FFDM were compared.
Results:
AI-CAD demonstrated a significantly lower median abnormality score (71% vs. 96%, P < 0.001) and poorer calibration performance for SM than for FFDM. SM exhibited lower sensitivity (76.2% vs. 82.8%, P < 0.001), higher specificity (95.5% vs.91.8%, P < 0.001), and comparable AUC (0.86 vs. 0.87, P = 0.127) than FFDM. SM showed lower sensitivity than FFDM in asymptomatic breasts, dense breasts, ductal carcinoma in situ, T1, N0, and hormone receptor-positive/human epidermal growth factor receptor 2-negative cancers but showed higher specificity in non-cancerous dense breasts.
Conclusion
AI-CAD showed lower abnormality scores and reduced calibration performance for SM than for FFDM.Furthermore, the 10% preset threshold resulted in different discrimination performances for the SM. Given these limitations, off-label application of the current AI-CAD to SM should be avoided.
6.Remaining life expectancy of Korean hemodialysis patients: how much longer can they live?
Hayne Cho PARK ; Do Hyoung KIM ; AJin CHO ; Bo Yeon KIM ; Miri LEE ; Gui Ok KIM ; Jinseog KIM ; Young-Ki LEE
Kidney Research and Clinical Practice 2024;43(5):671-679
Hemodialysis (HD) patients have a higher mortality rate compared to the general population. However, no study has investigated life expectancy in Korean HD patients so far. Therefore, this study aimed to calculate the remaining life expectancy among Korean maintenance HD patients and compare it to those of the general population as well as HD patients from other countries. Methods: Baseline data were retrieved from HD quality assessment data from 2015. Among the patients over 30 years old who were alive at the beginning of 2016 (20,304 males and 14,264 females), a total of 22,078 (12,621 males and 9,457 females) were still alive at the end of 2021 while 12,490 (7,683 males and 4,807 females) were deceased during 6 years of follow-up. We used the life table method to calculate the expected remaining years of life in 2-year increments. Results: The remaining life expectancies for 60-year-old patients were 11.64 years for males and 14.64 years for females. The average remaining life expectancies of the HD population were only about half of the general population. Diabetic patients demonstrated shorter life expectancy compared to patients with hypertension or glomerulonephritis. The remaining life expectancy of Korean HD patients was similar to that of Japanese and was almost double that of HD patients in Western countries such as Europe and the United States. Conclusion: The HD population shows a shorter life expectancy compared to the general population. Longitudinal analysis should be warranted to analyze the effect of advanced dialysis technology on improved survival rates among the HD population.
7.Remaining life expectancy of Korean hemodialysis patients: how much longer can they live?
Hayne Cho PARK ; Do Hyoung KIM ; AJin CHO ; Bo Yeon KIM ; Miri LEE ; Gui Ok KIM ; Jinseog KIM ; Young-Ki LEE
Kidney Research and Clinical Practice 2024;43(5):671-679
Hemodialysis (HD) patients have a higher mortality rate compared to the general population. However, no study has investigated life expectancy in Korean HD patients so far. Therefore, this study aimed to calculate the remaining life expectancy among Korean maintenance HD patients and compare it to those of the general population as well as HD patients from other countries. Methods: Baseline data were retrieved from HD quality assessment data from 2015. Among the patients over 30 years old who were alive at the beginning of 2016 (20,304 males and 14,264 females), a total of 22,078 (12,621 males and 9,457 females) were still alive at the end of 2021 while 12,490 (7,683 males and 4,807 females) were deceased during 6 years of follow-up. We used the life table method to calculate the expected remaining years of life in 2-year increments. Results: The remaining life expectancies for 60-year-old patients were 11.64 years for males and 14.64 years for females. The average remaining life expectancies of the HD population were only about half of the general population. Diabetic patients demonstrated shorter life expectancy compared to patients with hypertension or glomerulonephritis. The remaining life expectancy of Korean HD patients was similar to that of Japanese and was almost double that of HD patients in Western countries such as Europe and the United States. Conclusion: The HD population shows a shorter life expectancy compared to the general population. Longitudinal analysis should be warranted to analyze the effect of advanced dialysis technology on improved survival rates among the HD population.
8.Remaining life expectancy of Korean hemodialysis patients: how much longer can they live?
Hayne Cho PARK ; Do Hyoung KIM ; AJin CHO ; Bo Yeon KIM ; Miri LEE ; Gui Ok KIM ; Jinseog KIM ; Young-Ki LEE
Kidney Research and Clinical Practice 2024;43(5):671-679
Hemodialysis (HD) patients have a higher mortality rate compared to the general population. However, no study has investigated life expectancy in Korean HD patients so far. Therefore, this study aimed to calculate the remaining life expectancy among Korean maintenance HD patients and compare it to those of the general population as well as HD patients from other countries. Methods: Baseline data were retrieved from HD quality assessment data from 2015. Among the patients over 30 years old who were alive at the beginning of 2016 (20,304 males and 14,264 females), a total of 22,078 (12,621 males and 9,457 females) were still alive at the end of 2021 while 12,490 (7,683 males and 4,807 females) were deceased during 6 years of follow-up. We used the life table method to calculate the expected remaining years of life in 2-year increments. Results: The remaining life expectancies for 60-year-old patients were 11.64 years for males and 14.64 years for females. The average remaining life expectancies of the HD population were only about half of the general population. Diabetic patients demonstrated shorter life expectancy compared to patients with hypertension or glomerulonephritis. The remaining life expectancy of Korean HD patients was similar to that of Japanese and was almost double that of HD patients in Western countries such as Europe and the United States. Conclusion: The HD population shows a shorter life expectancy compared to the general population. Longitudinal analysis should be warranted to analyze the effect of advanced dialysis technology on improved survival rates among the HD population.
9.Remaining life expectancy of Korean hemodialysis patients: how much longer can they live?
Hayne Cho PARK ; Do Hyoung KIM ; AJin CHO ; Bo Yeon KIM ; Miri LEE ; Gui Ok KIM ; Jinseog KIM ; Young-Ki LEE
Kidney Research and Clinical Practice 2024;43(5):671-679
Hemodialysis (HD) patients have a higher mortality rate compared to the general population. However, no study has investigated life expectancy in Korean HD patients so far. Therefore, this study aimed to calculate the remaining life expectancy among Korean maintenance HD patients and compare it to those of the general population as well as HD patients from other countries. Methods: Baseline data were retrieved from HD quality assessment data from 2015. Among the patients over 30 years old who were alive at the beginning of 2016 (20,304 males and 14,264 females), a total of 22,078 (12,621 males and 9,457 females) were still alive at the end of 2021 while 12,490 (7,683 males and 4,807 females) were deceased during 6 years of follow-up. We used the life table method to calculate the expected remaining years of life in 2-year increments. Results: The remaining life expectancies for 60-year-old patients were 11.64 years for males and 14.64 years for females. The average remaining life expectancies of the HD population were only about half of the general population. Diabetic patients demonstrated shorter life expectancy compared to patients with hypertension or glomerulonephritis. The remaining life expectancy of Korean HD patients was similar to that of Japanese and was almost double that of HD patients in Western countries such as Europe and the United States. Conclusion: The HD population shows a shorter life expectancy compared to the general population. Longitudinal analysis should be warranted to analyze the effect of advanced dialysis technology on improved survival rates among the HD population.
10.Transradial Versus Transfemoral Access for Bifurcation Percutaneous Coronary Intervention Using SecondGeneration Drug-Eluting Stent
Jung-Hee LEE ; Young Jin YOUN ; Ho Sung JEON ; Jun-Won LEE ; Sung Gyun AHN ; Junghan YOON ; Hyeon-Cheol GWON ; Young Bin SONG ; Ki Hong CHOI ; Hyo-Soo KIM ; Woo Jung CHUN ; Seung-Ho HUR ; Chang-Wook NAM ; Yun-Kyeong CHO ; Seung Hwan HAN ; Seung-Woon RHA ; In-Ho CHAE ; Jin-Ok JEONG ; Jung Ho HEO ; Do-Sun LIM ; Jong-Seon PARK ; Myeong-Ki HONG ; Joon-Hyung DOH ; Kwang Soo CHA ; Doo-Il KIM ; Sang Yeub LEE ; Kiyuk CHANG ; Byung-Hee HWANG ; So-Yeon CHOI ; Myung Ho JEONG ; Hyun-Jong LEE
Journal of Korean Medical Science 2024;39(10):e111-
Background:
The benefits of transradial access (TRA) over transfemoral access (TFA) for bifurcation percutaneous coronary intervention (PCI) are uncertain because of the limited availability of device selection. This study aimed to compare the procedural differences and the in-hospital and long-term outcomes of TRA and TFA for bifurcation PCI using secondgeneration drug-eluting stents (DESs).
Methods:
Based on data from the Coronary Bifurcation Stenting Registry III, a retrospective registry of 2,648 patients undergoing bifurcation PCI with second-generation DES from 21 centers in South Korea, patients were categorized into the TRA group (n = 1,507) or the TFA group (n = 1,141). After propensity score matching (PSM), procedural differences, in-hospital outcomes, and device-oriented composite outcomes (DOCOs; a composite of cardiac death, target vessel-related myocardial infarction, and target lesion revascularization) were compared between the two groups (772 matched patients each group).
Results:
Despite well-balanced baseline clinical and lesion characteristics after PSM, the use of the two-stent strategy (14.2% vs. 23.7%, P = 0.001) and the incidence of in-hospital adverse outcomes, primarily driven by access site complications (2.2% vs. 4.4%, P = 0.015), were significantly lower in the TRA group than in the TFA group. At the 5-year follow-up, the incidence of DOCOs was similar between the groups (6.3% vs. 7.1%, P = 0.639).
Conclusion
The findings suggested that TRA may be safer than TFA for bifurcation PCI using second-generation DESs. Despite differences in treatment strategy, TRA was associated with similar long-term clinical outcomes as those of TFA. Therefore, TRA might be the preferred access for bifurcation PCI using second-generation DES.

Result Analysis
Print
Save
E-mail