1.Outcomes of Deferring Percutaneous Coronary Intervention Without Physiologic Assessment for Intermediate Coronary Lesions
Jihoon KIM ; Seong-Hoon LIM ; Joo-Yong HAHN ; Jin-Ok JEONG ; Yong Hwan PARK ; Woo Jung CHUN ; Ju Hyeon OH ; Dae Kyoung CHO ; Yu Jeong CHOI ; Eul-Soon IM ; Kyung-Heon WON ; Sung Yun LEE ; Sang-Wook KIM ; Ki Hong CHOI ; Joo Myung LEE ; Taek Kyu PARK ; Jeong Hoon YANG ; Young Bin SONG ; Seung-Hyuk CHOI ; Hyeon-Cheol GWON
Korean Circulation Journal 2025;55(3):185-195
Background and Objectives:
Outcomes of deferring percutaneous coronary intervention (PCI) without invasive physiologic assessment for intermediate coronary lesions is uncertain.We sought to compare long-term outcomes between medical treatment and PCI of intermediate lesions without invasive physiologic assessment.
Methods:
A total of 899 patients with intermediate coronary lesions between 50% and 70% diameter-stenosis were randomized to the conservative group (n=449) or the aggressive group (n=450). For intermediate lesions, PCI was performed in the aggressive group, but was deferred in the conservative group. The primary endpoint was major adverse cardiac events (MACE, a composite of all-cause death, myocardial infarction [MI], or ischemia-driven any revascularization) at 3 years.
Results:
The number of treated lesions per patient was 0.8±0.9 in the conservative group and 1.7±0.9 in the aggressive group (p=0.001). At 3 years, the conservative group had a significantly higher incidence of MACE than the aggressive group (13.8% vs. 9.3%; hazard ratio [HR], 1.49; 95% confidence interval [CI], 1.00–2.21; p=0.049), mainly driven by revascularization of target intermediate lesion (6.5% vs. 1.1%; HR, 5.69; 95% CI, 2.20–14.73;p<0.001). Between 1 and 3 years after the index procedure, compared to the aggressive group, the conservative group had significantly higher incidence of cardiac death or MI (3.2% vs.0.7%; HR, 4.34; 95% CI, 1.24–15.22; p=0.022) and ischemia-driven any revascularization.
Conclusions
For intermediate lesions, medical therapy alone, guided only by angiography, was associated with a higher risk of MACE at 3 years compared with performing PCI, mainly due to increased revascularization.
2.Outcomes of Deferring Percutaneous Coronary Intervention Without Physiologic Assessment for Intermediate Coronary Lesions
Jihoon KIM ; Seong-Hoon LIM ; Joo-Yong HAHN ; Jin-Ok JEONG ; Yong Hwan PARK ; Woo Jung CHUN ; Ju Hyeon OH ; Dae Kyoung CHO ; Yu Jeong CHOI ; Eul-Soon IM ; Kyung-Heon WON ; Sung Yun LEE ; Sang-Wook KIM ; Ki Hong CHOI ; Joo Myung LEE ; Taek Kyu PARK ; Jeong Hoon YANG ; Young Bin SONG ; Seung-Hyuk CHOI ; Hyeon-Cheol GWON
Korean Circulation Journal 2025;55(3):185-195
Background and Objectives:
Outcomes of deferring percutaneous coronary intervention (PCI) without invasive physiologic assessment for intermediate coronary lesions is uncertain.We sought to compare long-term outcomes between medical treatment and PCI of intermediate lesions without invasive physiologic assessment.
Methods:
A total of 899 patients with intermediate coronary lesions between 50% and 70% diameter-stenosis were randomized to the conservative group (n=449) or the aggressive group (n=450). For intermediate lesions, PCI was performed in the aggressive group, but was deferred in the conservative group. The primary endpoint was major adverse cardiac events (MACE, a composite of all-cause death, myocardial infarction [MI], or ischemia-driven any revascularization) at 3 years.
Results:
The number of treated lesions per patient was 0.8±0.9 in the conservative group and 1.7±0.9 in the aggressive group (p=0.001). At 3 years, the conservative group had a significantly higher incidence of MACE than the aggressive group (13.8% vs. 9.3%; hazard ratio [HR], 1.49; 95% confidence interval [CI], 1.00–2.21; p=0.049), mainly driven by revascularization of target intermediate lesion (6.5% vs. 1.1%; HR, 5.69; 95% CI, 2.20–14.73;p<0.001). Between 1 and 3 years after the index procedure, compared to the aggressive group, the conservative group had significantly higher incidence of cardiac death or MI (3.2% vs.0.7%; HR, 4.34; 95% CI, 1.24–15.22; p=0.022) and ischemia-driven any revascularization.
Conclusions
For intermediate lesions, medical therapy alone, guided only by angiography, was associated with a higher risk of MACE at 3 years compared with performing PCI, mainly due to increased revascularization.
3.Performance of Digital Mammography-Based Artificial Intelligence Computer-Aided Diagnosis on Synthetic Mammography From Digital Breast Tomosynthesis
Kyung Eun LEE ; Sung Eun SONG ; Kyu Ran CHO ; Min Sun BAE ; Bo Kyoung SEO ; Soo-Yeon KIM ; Ok Hee WOO
Korean Journal of Radiology 2025;26(3):217-229
Objective:
To test the performance of an artificial intelligence-based computer-aided diagnosis (AI-CAD) designed for fullfield digital mammography (FFDM) when applied to synthetic mammography (SM).
Materials and Methods:
We analyzed 501 women (mean age, 57 ± 11 years) who underwent preoperative mammography and breast cancer surgery. This cohort consisted of 1002 breasts, comprising 517 with cancer and 485 without. All patients underwent digital breast tomosynthesis (DBT) and FFDM during the preoperative workup. The SM is routinely reconstructed using DBT. Commercial AI-CAD (Lunit Insight MMG, version 1.1.7.2) was retrospectively applied to SM and FFDM to calculate the abnormality scores for each breast. The median abnormality scores were compared for the 517 breasts with cancer using the Wilcoxon signed-rank test. Calibration curves of abnormality scores were evaluated. The discrimination performance was analyzed using the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity using a 10% preset threshold. Sensitivity and specificity were further analyzed according to the mammographic and pathological characteristics.The results of SM and FFDM were compared.
Results:
AI-CAD demonstrated a significantly lower median abnormality score (71% vs. 96%, P < 0.001) and poorer calibration performance for SM than for FFDM. SM exhibited lower sensitivity (76.2% vs. 82.8%, P < 0.001), higher specificity (95.5% vs.91.8%, P < 0.001), and comparable AUC (0.86 vs. 0.87, P = 0.127) than FFDM. SM showed lower sensitivity than FFDM in asymptomatic breasts, dense breasts, ductal carcinoma in situ, T1, N0, and hormone receptor-positive/human epidermal growth factor receptor 2-negative cancers but showed higher specificity in non-cancerous dense breasts.
Conclusion
AI-CAD showed lower abnormality scores and reduced calibration performance for SM than for FFDM.Furthermore, the 10% preset threshold resulted in different discrimination performances for the SM. Given these limitations, off-label application of the current AI-CAD to SM should be avoided.
4.Performance of Digital Mammography-Based Artificial Intelligence Computer-Aided Diagnosis on Synthetic Mammography From Digital Breast Tomosynthesis
Kyung Eun LEE ; Sung Eun SONG ; Kyu Ran CHO ; Min Sun BAE ; Bo Kyoung SEO ; Soo-Yeon KIM ; Ok Hee WOO
Korean Journal of Radiology 2025;26(3):217-229
Objective:
To test the performance of an artificial intelligence-based computer-aided diagnosis (AI-CAD) designed for fullfield digital mammography (FFDM) when applied to synthetic mammography (SM).
Materials and Methods:
We analyzed 501 women (mean age, 57 ± 11 years) who underwent preoperative mammography and breast cancer surgery. This cohort consisted of 1002 breasts, comprising 517 with cancer and 485 without. All patients underwent digital breast tomosynthesis (DBT) and FFDM during the preoperative workup. The SM is routinely reconstructed using DBT. Commercial AI-CAD (Lunit Insight MMG, version 1.1.7.2) was retrospectively applied to SM and FFDM to calculate the abnormality scores for each breast. The median abnormality scores were compared for the 517 breasts with cancer using the Wilcoxon signed-rank test. Calibration curves of abnormality scores were evaluated. The discrimination performance was analyzed using the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity using a 10% preset threshold. Sensitivity and specificity were further analyzed according to the mammographic and pathological characteristics.The results of SM and FFDM were compared.
Results:
AI-CAD demonstrated a significantly lower median abnormality score (71% vs. 96%, P < 0.001) and poorer calibration performance for SM than for FFDM. SM exhibited lower sensitivity (76.2% vs. 82.8%, P < 0.001), higher specificity (95.5% vs.91.8%, P < 0.001), and comparable AUC (0.86 vs. 0.87, P = 0.127) than FFDM. SM showed lower sensitivity than FFDM in asymptomatic breasts, dense breasts, ductal carcinoma in situ, T1, N0, and hormone receptor-positive/human epidermal growth factor receptor 2-negative cancers but showed higher specificity in non-cancerous dense breasts.
Conclusion
AI-CAD showed lower abnormality scores and reduced calibration performance for SM than for FFDM.Furthermore, the 10% preset threshold resulted in different discrimination performances for the SM. Given these limitations, off-label application of the current AI-CAD to SM should be avoided.
5.Performance of Digital Mammography-Based Artificial Intelligence Computer-Aided Diagnosis on Synthetic Mammography From Digital Breast Tomosynthesis
Kyung Eun LEE ; Sung Eun SONG ; Kyu Ran CHO ; Min Sun BAE ; Bo Kyoung SEO ; Soo-Yeon KIM ; Ok Hee WOO
Korean Journal of Radiology 2025;26(3):217-229
Objective:
To test the performance of an artificial intelligence-based computer-aided diagnosis (AI-CAD) designed for fullfield digital mammography (FFDM) when applied to synthetic mammography (SM).
Materials and Methods:
We analyzed 501 women (mean age, 57 ± 11 years) who underwent preoperative mammography and breast cancer surgery. This cohort consisted of 1002 breasts, comprising 517 with cancer and 485 without. All patients underwent digital breast tomosynthesis (DBT) and FFDM during the preoperative workup. The SM is routinely reconstructed using DBT. Commercial AI-CAD (Lunit Insight MMG, version 1.1.7.2) was retrospectively applied to SM and FFDM to calculate the abnormality scores for each breast. The median abnormality scores were compared for the 517 breasts with cancer using the Wilcoxon signed-rank test. Calibration curves of abnormality scores were evaluated. The discrimination performance was analyzed using the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity using a 10% preset threshold. Sensitivity and specificity were further analyzed according to the mammographic and pathological characteristics.The results of SM and FFDM were compared.
Results:
AI-CAD demonstrated a significantly lower median abnormality score (71% vs. 96%, P < 0.001) and poorer calibration performance for SM than for FFDM. SM exhibited lower sensitivity (76.2% vs. 82.8%, P < 0.001), higher specificity (95.5% vs.91.8%, P < 0.001), and comparable AUC (0.86 vs. 0.87, P = 0.127) than FFDM. SM showed lower sensitivity than FFDM in asymptomatic breasts, dense breasts, ductal carcinoma in situ, T1, N0, and hormone receptor-positive/human epidermal growth factor receptor 2-negative cancers but showed higher specificity in non-cancerous dense breasts.
Conclusion
AI-CAD showed lower abnormality scores and reduced calibration performance for SM than for FFDM.Furthermore, the 10% preset threshold resulted in different discrimination performances for the SM. Given these limitations, off-label application of the current AI-CAD to SM should be avoided.
6.Outcomes of Deferring Percutaneous Coronary Intervention Without Physiologic Assessment for Intermediate Coronary Lesions
Jihoon KIM ; Seong-Hoon LIM ; Joo-Yong HAHN ; Jin-Ok JEONG ; Yong Hwan PARK ; Woo Jung CHUN ; Ju Hyeon OH ; Dae Kyoung CHO ; Yu Jeong CHOI ; Eul-Soon IM ; Kyung-Heon WON ; Sung Yun LEE ; Sang-Wook KIM ; Ki Hong CHOI ; Joo Myung LEE ; Taek Kyu PARK ; Jeong Hoon YANG ; Young Bin SONG ; Seung-Hyuk CHOI ; Hyeon-Cheol GWON
Korean Circulation Journal 2025;55(3):185-195
Background and Objectives:
Outcomes of deferring percutaneous coronary intervention (PCI) without invasive physiologic assessment for intermediate coronary lesions is uncertain.We sought to compare long-term outcomes between medical treatment and PCI of intermediate lesions without invasive physiologic assessment.
Methods:
A total of 899 patients with intermediate coronary lesions between 50% and 70% diameter-stenosis were randomized to the conservative group (n=449) or the aggressive group (n=450). For intermediate lesions, PCI was performed in the aggressive group, but was deferred in the conservative group. The primary endpoint was major adverse cardiac events (MACE, a composite of all-cause death, myocardial infarction [MI], or ischemia-driven any revascularization) at 3 years.
Results:
The number of treated lesions per patient was 0.8±0.9 in the conservative group and 1.7±0.9 in the aggressive group (p=0.001). At 3 years, the conservative group had a significantly higher incidence of MACE than the aggressive group (13.8% vs. 9.3%; hazard ratio [HR], 1.49; 95% confidence interval [CI], 1.00–2.21; p=0.049), mainly driven by revascularization of target intermediate lesion (6.5% vs. 1.1%; HR, 5.69; 95% CI, 2.20–14.73;p<0.001). Between 1 and 3 years after the index procedure, compared to the aggressive group, the conservative group had significantly higher incidence of cardiac death or MI (3.2% vs.0.7%; HR, 4.34; 95% CI, 1.24–15.22; p=0.022) and ischemia-driven any revascularization.
Conclusions
For intermediate lesions, medical therapy alone, guided only by angiography, was associated with a higher risk of MACE at 3 years compared with performing PCI, mainly due to increased revascularization.
7.Performance of Digital Mammography-Based Artificial Intelligence Computer-Aided Diagnosis on Synthetic Mammography From Digital Breast Tomosynthesis
Kyung Eun LEE ; Sung Eun SONG ; Kyu Ran CHO ; Min Sun BAE ; Bo Kyoung SEO ; Soo-Yeon KIM ; Ok Hee WOO
Korean Journal of Radiology 2025;26(3):217-229
Objective:
To test the performance of an artificial intelligence-based computer-aided diagnosis (AI-CAD) designed for fullfield digital mammography (FFDM) when applied to synthetic mammography (SM).
Materials and Methods:
We analyzed 501 women (mean age, 57 ± 11 years) who underwent preoperative mammography and breast cancer surgery. This cohort consisted of 1002 breasts, comprising 517 with cancer and 485 without. All patients underwent digital breast tomosynthesis (DBT) and FFDM during the preoperative workup. The SM is routinely reconstructed using DBT. Commercial AI-CAD (Lunit Insight MMG, version 1.1.7.2) was retrospectively applied to SM and FFDM to calculate the abnormality scores for each breast. The median abnormality scores were compared for the 517 breasts with cancer using the Wilcoxon signed-rank test. Calibration curves of abnormality scores were evaluated. The discrimination performance was analyzed using the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity using a 10% preset threshold. Sensitivity and specificity were further analyzed according to the mammographic and pathological characteristics.The results of SM and FFDM were compared.
Results:
AI-CAD demonstrated a significantly lower median abnormality score (71% vs. 96%, P < 0.001) and poorer calibration performance for SM than for FFDM. SM exhibited lower sensitivity (76.2% vs. 82.8%, P < 0.001), higher specificity (95.5% vs.91.8%, P < 0.001), and comparable AUC (0.86 vs. 0.87, P = 0.127) than FFDM. SM showed lower sensitivity than FFDM in asymptomatic breasts, dense breasts, ductal carcinoma in situ, T1, N0, and hormone receptor-positive/human epidermal growth factor receptor 2-negative cancers but showed higher specificity in non-cancerous dense breasts.
Conclusion
AI-CAD showed lower abnormality scores and reduced calibration performance for SM than for FFDM.Furthermore, the 10% preset threshold resulted in different discrimination performances for the SM. Given these limitations, off-label application of the current AI-CAD to SM should be avoided.
8.Outcomes of Deferring Percutaneous Coronary Intervention Without Physiologic Assessment for Intermediate Coronary Lesions
Jihoon KIM ; Seong-Hoon LIM ; Joo-Yong HAHN ; Jin-Ok JEONG ; Yong Hwan PARK ; Woo Jung CHUN ; Ju Hyeon OH ; Dae Kyoung CHO ; Yu Jeong CHOI ; Eul-Soon IM ; Kyung-Heon WON ; Sung Yun LEE ; Sang-Wook KIM ; Ki Hong CHOI ; Joo Myung LEE ; Taek Kyu PARK ; Jeong Hoon YANG ; Young Bin SONG ; Seung-Hyuk CHOI ; Hyeon-Cheol GWON
Korean Circulation Journal 2025;55(3):185-195
Background and Objectives:
Outcomes of deferring percutaneous coronary intervention (PCI) without invasive physiologic assessment for intermediate coronary lesions is uncertain.We sought to compare long-term outcomes between medical treatment and PCI of intermediate lesions without invasive physiologic assessment.
Methods:
A total of 899 patients with intermediate coronary lesions between 50% and 70% diameter-stenosis were randomized to the conservative group (n=449) or the aggressive group (n=450). For intermediate lesions, PCI was performed in the aggressive group, but was deferred in the conservative group. The primary endpoint was major adverse cardiac events (MACE, a composite of all-cause death, myocardial infarction [MI], or ischemia-driven any revascularization) at 3 years.
Results:
The number of treated lesions per patient was 0.8±0.9 in the conservative group and 1.7±0.9 in the aggressive group (p=0.001). At 3 years, the conservative group had a significantly higher incidence of MACE than the aggressive group (13.8% vs. 9.3%; hazard ratio [HR], 1.49; 95% confidence interval [CI], 1.00–2.21; p=0.049), mainly driven by revascularization of target intermediate lesion (6.5% vs. 1.1%; HR, 5.69; 95% CI, 2.20–14.73;p<0.001). Between 1 and 3 years after the index procedure, compared to the aggressive group, the conservative group had significantly higher incidence of cardiac death or MI (3.2% vs.0.7%; HR, 4.34; 95% CI, 1.24–15.22; p=0.022) and ischemia-driven any revascularization.
Conclusions
For intermediate lesions, medical therapy alone, guided only by angiography, was associated with a higher risk of MACE at 3 years compared with performing PCI, mainly due to increased revascularization.
9.Performance of Digital Mammography-Based Artificial Intelligence Computer-Aided Diagnosis on Synthetic Mammography From Digital Breast Tomosynthesis
Kyung Eun LEE ; Sung Eun SONG ; Kyu Ran CHO ; Min Sun BAE ; Bo Kyoung SEO ; Soo-Yeon KIM ; Ok Hee WOO
Korean Journal of Radiology 2025;26(3):217-229
Objective:
To test the performance of an artificial intelligence-based computer-aided diagnosis (AI-CAD) designed for fullfield digital mammography (FFDM) when applied to synthetic mammography (SM).
Materials and Methods:
We analyzed 501 women (mean age, 57 ± 11 years) who underwent preoperative mammography and breast cancer surgery. This cohort consisted of 1002 breasts, comprising 517 with cancer and 485 without. All patients underwent digital breast tomosynthesis (DBT) and FFDM during the preoperative workup. The SM is routinely reconstructed using DBT. Commercial AI-CAD (Lunit Insight MMG, version 1.1.7.2) was retrospectively applied to SM and FFDM to calculate the abnormality scores for each breast. The median abnormality scores were compared for the 517 breasts with cancer using the Wilcoxon signed-rank test. Calibration curves of abnormality scores were evaluated. The discrimination performance was analyzed using the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity using a 10% preset threshold. Sensitivity and specificity were further analyzed according to the mammographic and pathological characteristics.The results of SM and FFDM were compared.
Results:
AI-CAD demonstrated a significantly lower median abnormality score (71% vs. 96%, P < 0.001) and poorer calibration performance for SM than for FFDM. SM exhibited lower sensitivity (76.2% vs. 82.8%, P < 0.001), higher specificity (95.5% vs.91.8%, P < 0.001), and comparable AUC (0.86 vs. 0.87, P = 0.127) than FFDM. SM showed lower sensitivity than FFDM in asymptomatic breasts, dense breasts, ductal carcinoma in situ, T1, N0, and hormone receptor-positive/human epidermal growth factor receptor 2-negative cancers but showed higher specificity in non-cancerous dense breasts.
Conclusion
AI-CAD showed lower abnormality scores and reduced calibration performance for SM than for FFDM.Furthermore, the 10% preset threshold resulted in different discrimination performances for the SM. Given these limitations, off-label application of the current AI-CAD to SM should be avoided.
10.Safety and Efficacy of Everolimus-Eluting Bioresorbable Vascular Scaffold Versus Second-Generation Drug-Eluting Stents in Real-World Practice
Joo Myung LEE ; Hyun Sung JOH ; Ki Hong CHOI ; David HONG ; Taek Kyu PARK ; Jeong Hoon YANG ; Young Bin SONG ; Jin-Ho CHOI ; Seung-Hyuk CHOI ; Jin-Ok JEONG ; Jong-Young LEE ; Young Jin CHOI ; Jei-Keon CHAE ; Seung-Ho HUR ; Jang-Whan BAE ; Ju-Hyeon OH ; Kook-Jin CHUN ; Hyun-Joong KIM ; Byung Ryul CHO ; Doosup SHIN ; Seung Hun LEE ; Doyeon HWANG ; Hyun-Jong LEE ; Ho-Jun JANG ; Hyun Kuk KIM ; Sang Jin HA ; Eun-Seok SHIN ; Joon-Hyung DOH ; Joo-Yong HAHN ; Hyeon-Cheol GWON ; On behalf of the SMART-REWARD Investigators
Journal of Korean Medical Science 2023;38(5):e34-
Background:
The risk of device thrombosis and device-oriented clinical outcomes with bioresorbable vascular scaffold (BVS) was reported to be significantly higher than with contemporary drug-eluting stents (DESs). However, optimal device implantation may improve clinical outcomes in patients receiving BVS. The current study evaluated mid-term safety and efficacy of Absorb BVS with meticulous device optimization under intravascular imaging guidance.
Methods:
The SMART-REWARD and PERSPECTIVE-PCI registries in Korea prospectively enrolled 390 patients with BVS and 675 patients with DES, respectively. The primary endpoint was target vessel failure (TVF) at 2 years and the secondary major endpoint was patientoriented composite outcome (POCO) at 2 years.
Results:
Patient-level pooled analysis evaluated 1,003 patients (377 patients with BVS and 626 patients with DES). Mean scaffold diameter per lesion was 3.24 ± 0.30 mm in BVS group.Most BVSs were implanted with pre-dilatation (90.9%), intravascular imaging guidance (74.9%), and post-dilatation (73.1%) at proximal to mid segment (81.9%) in target vessel.Patients treated with BVS showed comparable risks of 2-year TVF (2.9% vs. 3.7%, adjusted hazard ratio [HR], 1.283, 95% confidence interval [CI], 0.487–3.378, P = 0.615) and 2-year POCO (4.5% vs. 5.9%, adjusted HR, 1.413, 95% CI, 0.663–3.012,P = 0.370) than those with DES. The rate of 2-year definite or probable device thrombosis (0.3% vs. 0.5%, P = 0.424) was also similar. The sensitivity analyses consistently showed comparable risk of TVF and POCO between the 2 groups.
Conclusion
With meticulous device optimization under imaging guidance and avoidance of implantation in small vessels, BVS showed comparable risks of 2-year TVF and device thrombosis with DES.

Result Analysis
Print
Save
E-mail