1.Analysis of verification results of protective effects of hearing protectors in different industries.
Han Xue SHI ; Shi Biao SU ; Ming LIU ; Rong Zong LI ; Tian Jian WANG ; Bin XIAO
Chinese Journal of Industrial Hygiene and Occupational Diseases 2023;41(5):333-337
Objective: To get insight into the current practice of noise reduction effect of workers as they wore hearing protectors in different domestic enterprises and the possible affected factors. Methods: From October 2020 to April 2021, using a random sampling method, 1197 workers exposed to noise in petrochemical factories, textile factories, and parts manufacturing factories were selected as the study subjects. The noise reduction effect of hearing protectors worn by workers in daily use was tested using a hearing protector suitability testing system. The personal sound attenuation level (PAR) was compared among workers in three enterprises, Targeted intervention and repetitive testing were conducted for workers who did not meet the noise reduction effect required by the enterprise, and the changes in PAR of workers before and after the intervention were compared. The comparison of baseline PARs between two or more groups was performed using the Mann Whitney test, the comparison of baseline PARs with post intervention PARs was performed using the Wilcoxon signed rank sum test, and the comparison of qualitative data between two or more groups was performed using the Chi square test. Results: The median baseline PAR for all workers was 15 dB. Men, age<30 years old, education level at or above college level, working experience of 5 to 15 years, and those who used hearing protectors for 5 to 15 years had higher PARs, with statistically significant differences (P<0.05). The median difference in baseline PAR among workers from three enterprises was statistically significant (H=175.06, P<0.01). The median PAR of subjects who did not pass the baseline increased from 3 dB to 21 dB after intervention (Z=-27.92, P<0.01) . Conclusion: Some workers wearing hearing protectors do not meet the required PAR, and low PARs may be related to incorrect wearing methods and incorrect selection of hearing protectors. As a tool for testing, training, and assisting in selection, the hearing protector suitability testing system is of great significance for worker hearing protection.
Male
;
Humans
;
Adult
;
Hearing Loss, Noise-Induced/prevention & control*
;
Ear Protective Devices
;
Noise, Occupational/prevention & control*
;
Hearing
;
Audiometry
2.Analysis of noise reduction measures in a noise workshop handover control room.
Rui Feng DONG ; Qing Dong WU ; Dong Liang CHAI ; Xiang Ming XUE ; Jing Ming ZHAN
Chinese Journal of Industrial Hygiene and Occupational Diseases 2023;41(5):379-382
Objective: To explore the sound insulation, sound absorption and other noise reduction transformation methods in a noise workshop handover control room. Methods: In December 2021, through the occupational health investigation and on-site testing of the handover control room of a noise workshop, the causes of excessive noise were analyzed, and the transformation design scheme to reduce noise was proposed and the effect was analyzed. Results: Before the transformation, the peak frequency band noise intensity of the noise workshop handover control room was 112.8 dB (A), and the peak frequency was 1000 Hz. After noise reduction, the theoretical calculated control value was 61.0 dB (A), and the measured noise intensity was 59.8 dB (A) . Conclusion: The noise intensity of the handover control room is reduced after noise reduction, which is in line with the contact limit requirements of the control room in GBZ 1-2010 "Hygienic Standards for the Design of Industrial Enterprises", and has reference significance for noise control engineering.
Noise/prevention & control*
;
Occupational Health
;
Industry
;
Reference Standards
;
Hygiene
;
Noise, Occupational/prevention & control*
3.Preliminary observation on the differential expression of metformin in preventing noise-induced hearing loss in inner ear protein group of rats.
An Ran ZHANG ; Ke Feng MA ; Xiao Jun SHE ; Hong Tao LIU ; Bo CUI ; Rui WANG
Chinese Journal of Industrial Hygiene and Occupational Diseases 2022;40(4):248-254
Objective: To study the protective effects of metformin on noise-induced hearing loss (NIHL) and its differential protein omics expression profile. Methods: In January 2021, 39 male Wistar rats were randomly divided into control group, noise exposure group and metformin+noise exposure group, with 13 rats in each group. Rats in the noise exposure group and metformin+noise exposure group were continuously exposed to octave noise with sound pressure level of 120 dB (A) and center frequency of 8 kHz for 4 h. Rats in the metformin+noise exposure group were treated with 200 mg/kg/d metformin 3 d before noise exposure for a total of 7 d. Auditory brainstem response (ABR) was used to test the changes of hearing thresholds before noise exposure and 1, 4, 7 d after noise exposure in the right ear of rats in each group. Tandem mass tag (TMT) quantitative proteomics was used to identify and analyze the differentially expressed protein in the inner ear of rats in each group, and it was verified by immunofluorescence staining with frozen sections. Results: The click-ABR thresholds of right ear in the noise exposure group and metformin+noise exposure group were significantly higher than those in the control group 1, 4, 7 d after noise exposure (P<0.05) . The click-ABR threshold of right ear in the metformin+noise exposure group were significantly lower than that in the noise exposure group (P<0.05) . Compared with the noise exposure group, 1035 up-regulated proteins and 1145 down-regulated proteins were differentially expressed in the metformin+noise exposure group. GO enrichment analysis showed that the significantly differentially expressed proteins were mainly involved in binding, molecular function regulation, signal transduction, and other functions. Enrichment analysis of KEGG pathway revealed that the pathways for significant enrichment of differentially expressed proteins included phosphatidylinositol 3-kinase-protein kinase B (PI3K-Akt) signaling pathway, focal adhesion, diabetic cardiomyopathy, mitogen, and mitogen-activated protein kinase (MAPK) signaling pathway. Immunofluorescence experiments showed that compared with the noise exposure group, the fluorescence intensity of insulin-like growth factor 1 receptor (IGF1R) in the metformin+noise exposure group was increased, and the fluorescence intensity of eukaryotic translation initiation factor 4E binding protein 1 (eIF4EBP1) was decreased. Conclusion: Noise exposure can lead to an increase in rat hearing threshold, and metformin can improve noise-induced hearing threshold abnormalities through multiple pathways and biological processes.
Animals
;
Auditory Threshold/physiology*
;
Cochlea
;
Ear, Inner
;
Evoked Potentials, Auditory, Brain Stem/physiology*
;
Hearing Loss, Noise-Induced/prevention & control*
;
Male
;
Metformin/pharmacology*
;
Phosphatidylinositol 3-Kinases/metabolism*
;
Rats
;
Rats, Wistar
4.An overview of occupational noise-induced hearing loss among workers: epidemiology, pathogenesis, and preventive measures.
Kou-Huang CHEN ; Shih-Bin SU ; Kow-Tong CHEN
Environmental Health and Preventive Medicine 2020;25(1):65-65
Occupational noise-induced hearing loss (ONIHL) is the most prevalent occupational disease in the world. The goal of this study was to review the epidemiology, pathogenesis, and preventive measures of ONIHL among workers and provide evidence for the implementation of control measures. Literature studies were identified from the MEDLINE, PubMed, Embase, Web of Science, and Google Scholar using the search terms "noise-induced hearing loss" "prevalence", "pathogenesis", and "preventive measures". The articles reviewed in this report were limited from 2000 to 2020. Articles that were not published in the English language, manuscripts without an abstract, and opinion articles were excluded. After a preliminary screening, all of the articles were reviewed and synthesized to provide an overview of the current status of ONIHL among workers. The mechanism of ONIHL among workers is a complex interaction between environmental and host factors (both genetic and acquired factors). The outcomes of noise exposure are different among individual subjects. Clinical trials are currently underway to evaluate the treatment effect of antioxidants on ONIHL. Noise exposure may contribute to temporary or permanent threshold shifts; however, even temporary threshold shifts may predispose an individual to eventual permanent hearing loss. Noise prevention programs are an important preventive measure in reducing the morbidity of ONIHL among workers.
Adult
;
Aged
;
Female
;
Hearing Loss, Noise-Induced/prevention & control*
;
Humans
;
Male
;
Middle Aged
;
Noise
;
Occupational Diseases/prevention & control*
;
Prevalence
;
Young Adult
5.Solid lipid nanoparticles loaded with edaravone for inner ear protection after noise exposure.
Gang GAO ; Ya LIU ; Chang-Hua ZHOU ; Ping JIANG ; Jian-Jun SUN
Chinese Medical Journal 2015;128(2):203-209
BACKGROUNDAntioxidants and the duration of treatment after noise exposure on hearing recovery are important. We investigated the protective effects of an antioxidant substance, edaravone, and its slow-release dosage form, edaravone solid lipid nanoparticles (SLNs), in steady noise-exposed guinea pigs.
METHODSSLNs loaded with edaravone were produced by an ultrasound technique. Edaravone solution or edaravone SLNs were administered by intratympanic or intravenous injection after the 1 st day of noise exposure. Guinea pigs were exposed to 110 dB sound pressure level (SPL) noise, centered at 0.25-4.0 kHz, for 4 days at 2 h/d. After noise exposure, the guinea pigs underwent auditory brainstem response (ABR) threshold measurements, reactive oxygen species (ROS) were detected in their cochleas with electron spin resonance (ESR), and outer hair cells (OHCs) were counted with silvernitrate (AgNO 3 ) staining at 1, 4, and 6 days.
RESULTSThe ultrasound technique was able to prepare adequate edaravone SLNs with a mean particle size of 93.6 nm and entrapment efficiency of 76.7%. Acoustic stress-induced ROS formation and edaravone exerted a protective effect on the cochlea. Comparisons of hearing thresholds and ROS changes in different animal groups showed that the threshold shift and ROS generation were significantly lower in treated animals than in those without treatment, especially in the edaravone SLN intratympanic injection group.
CONCLUSIONSEdaravone SLNs show noticeable slow-release effects and have certain protective effects against noise-induced hearing loss (NIHL).
Animals ; Antipyrine ; analogs & derivatives ; chemistry ; Ear, Inner ; drug effects ; injuries ; Female ; Guinea Pigs ; Hearing Loss, Noise-Induced ; prevention & control ; Lipids ; chemistry ; Nanoparticles ; chemistry ; Reactive Oxygen Species ; metabolism
6.Numerical simulation of the internal noise in the pressure generator of a continuous positive airway pressure ventilator.
Yunzhang CHENG ; Fangfang HUANG ; Lihua ZHU
Journal of Biomedical Engineering 2013;30(2):312-315
It is important to overcome the problem of noise for the research and development of ventilator technologies. Previous research of this subject showed that the pressure generator, produced by German EMB-PAPST Company and specially used for continuous positive airway pressure (CPAP) ventilator, created noise easily, due to local backflow in the volute, uneven velocity distribution in the impeller and local negative pressure in the inlet of the impeller. Based on the previous research, a combination of the computational fluid dynamics (CFD) software FLUENT and steady-state solution of noise source of Reynolds-Averaged Navier-Stokes (RANS) was used in this study. We combined equation of Lilley and Synthetic Turbulence to get the information about speed fluctuation of the pressure generator, which is used to finish noise prediction. After detailed analysis, it showed that noise source of different degrees spreaded around the inlet of the impeller and the volute, interface of blade edge and corner of the volute tongue, which influenced its overall performance to certain extent. Therefore, its structural design needs to be improved.
Algorithms
;
Computer Simulation
;
Continuous Positive Airway Pressure
;
adverse effects
;
instrumentation
;
Equipment Design
;
methods
;
Models, Theoretical
;
Noise
;
prevention & control
7.A cross-sectional study on the industrial noise over-limit status in Guangzhou factories.
Wei-sen ZHANG ; Wei-jia DU ; Zhi WANG ; Shi-qi MAI ; Qi-rong XU ; Yi-min LIU
Chinese Journal of Industrial Hygiene and Occupational Diseases 2011;29(3):216-219
OBJECTIVETo investigate the industrial noise over-limit status of the worksites in Guangzhou factories, so as to promote the prevention and control of occupational noise hazards.
METHODS211 factories in Guangzhou were monitored and investigated. The analysis and assessment were developed for the properties and size of the factories, the districts of the factories being located, the industries of the factories being classified and the date of monitoring.
RESULTSIn this understudied factories, most of them were national-owned and joint-ventures, medium size, located in urban, and mainly involved in the industries of manufacturing of motor vehicle, shipping, electron and electric equipment, and the industries of petroleum and chemicals. The prevalence of noise over-limit was higher in joint-ventures (36.0%) and private-run enterprises (31.2%). The over-limit status mainly presented in industries of textile, food and beverage processing, and leather producing, with getting prevalence of over-limit 46.7%, 43.1% and 41.3% respectively. Subsequence were industries of manufacturing of electron and electric equipment, motor vehicle and shipping, and industries of printing and goods producing for culture and sports, with the prevalence for all > 35%. Factories monitored during spring and summer also had higher prevalence of noise over-limit. The similar results were got after adjustment for each other using multivariable regression. The most common over-limit sites mainly focused on the operation of cutting and sawing, milling and planing, pressing, riveting, drilling, jointing, assembling and quality inspecting in industries of mechanism processing and manufacturing, on quality inspecting and packing in industries of pharmacy and food and beverage manufacture, on spinning and scutching in textile industry, and on cleaning and maintaining as assistant jobs, and patrolling and inspecting air-press machine, ventilation machine, dynamotor and pump.
CONCLUSIONNoise in Guangzhou factories widely exists with different industries and districts. To strengthen noise occupational hazards prevention and control for the high risk districts, industries and worksites should be the key job in the future.
China ; Cross-Sectional Studies ; Industry ; Noise, Occupational ; prevention & control ; Occupational Exposure ; prevention & control ; Occupational Health ; Workplace
8.The numerical simulation of the internal flow field inside the pressure generator of a continuous positive airway pressure ventilator.
Yunzhang CHENG ; Lihua ZHU ; Weiguo ZHANG ; Wenquan WU
Journal of Biomedical Engineering 2011;28(6):1131-1135
The problem of noise in ventilator has always been an important topic to study in the development of the ventilator. A great number of data are showing that there are still large gaps of research and application levels in noise control of the ventilator between China and some more advanced foreign countries. In this study, with cooperation of the Shanghai Medical Equipment Limited Liability Company, we used the computational fluid dynamics (CFD), software FLUENT, adopted the standard k-epsilon turbulence model and the SIMPLE algorithm to simulate the inner flow field of the continuous positive airway pressure (CPAP) ventilator's pressure generator. After a detailed analysis, we figured out that there are several deficiencies in this ventilator, like local reflow in volute, uneven velocity distribution and local negative pressure in inlet of the impeller, which easily lead to noise and affect the ventilator's performances. So, it needs to be improved to a certain extent.
Algorithms
;
Computer Simulation
;
Continuous Positive Airway Pressure
;
adverse effects
;
instrumentation
;
Equipment Design
;
methods
;
Models, Theoretical
;
Noise
;
prevention & control
9.The study of active noise control method for noisy surgery tools.
Bin LIAO ; Yanjian LIAO ; Hongyan LUO
Journal of Biomedical Engineering 2011;28(6):1126-1140
Noise problem is encountered in many types of surgery, especially in orthopaedic surgery, where the cutting tool and its actuation part such as motor always generates big noise. This work is dedicated to developing a novel and promising solution based on the active noise control (ANC) technology to solve the noise problem in an orthopaedic theatre. The development process began with building an engineering evaluation model (EEM) to analyze the specifics of sound interactions and sound field involved in the noise problem. This model can describe the acoustic problem in a straightforward way, help to design a good control system and furthermore to assess the result and to optimize the control structure. Then the "auto position tracking near head space ANC" strategy was proposed from the model study. Furthermore, the real sound field measurement experiment proved the possibility of proposed design.
Humans
;
Models, Theoretical
;
Noise
;
prevention & control
;
Operating Rooms
;
Orthopedic Procedures
;
instrumentation
;
Surgical Instruments
10.Study of protective effects on noise-induced hearing loss using N-acetyl-cysteine.
Zhenmin GE ; Shu MA ; Xiaoqing JIA ; Li SONG
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2011;25(22):1040-1041
OBJECTIVE:
To evaluate the protective effects of oral administration of N-acetyl-cysteine (NAC) on noise-induced hearing loss.
METHOD:
Three hundred sixty three volunteers were recruited and randomly divided into two groups: experimental group (n=223) and control group (n=140). The subjects had received oral administration of NAC in the experimental group and placebo in the control group before noise exposure. The routine audiometric evaluation and ABR testing were performed and recorded pre- and post-noise exposure. The statistical analysis was carried out on the data obtained from two groups with SPSS 11.0.
RESULT:
The hearings of all the participatory were changed after noise exposure, but there were statistically significant differences between two groups.
CONCLUSION
The protective effects of NAC were prominent on the noise-induced hearing loss.
Acetylcysteine
;
administration & dosage
;
therapeutic use
;
Adult
;
Hearing Loss, Noise-Induced
;
drug therapy
;
prevention & control
;
Humans
;
Male
;
Military Personnel
;
Young Adult

Result Analysis
Print
Save
E-mail