1.Effectiveness of transabdominal ultrasonography in predicting clinical relapse of Crohn’s disease
Shinya FUKUSHIMA ; Takehiko KATSURADA ; Mutsumi NISHIDA ; Satomi OMOTEHARA ; Kensuke SAKURAI ; Kana YAMANASHI ; Reizo ONISHI ; Naoya SAKAMOTO
Intestinal Research 2024;22(1):82-91
Background/Aims:
Transabdominal ultrasonography (US) helps evaluate Crohn’s disease (CD) activity. We investigated whether the US could predict subsequent adverse outcomes for patients with CD in clinical remission.
Methods:
This single-center retrospective study included patients with CD in clinical remission who underwent US between April 2011 and April 2021, focusing on the predictability of subsequent adverse outcomes within 5 years. We used the US-CD, which was calculated using multiple US findings. Predictive variables were assessed using Cox proportional hazards regression analysis, and the predictive value was evaluated using receiver operating characteristic curves.
Results:
Seventy-three patients were included. During a median follow-up of 1,441 days (range, 41–1,825 days), 16.4% (12/73) experienced clinical relapse, 9.6% (7/73) required endoscopic balloon dilation (EBD), 58.9% (43/73) required enhanced treatment, and 20.5% (15/73) underwent surgery. In the multivariate analysis, US-CD was significantly associated with clinical relapse (P= 0.038) and the need for enhanced treatment (P= 0.005). The area under the receiver operating characteristic curve for predicting clinical relapse and the need for EBD was 0.77 and 0.81, respectively, with US-CD (cutoff value = 11), and that for requiring enhanced treatment was 0.74 with US-CD (cutoff value = 6). Patients with US-CD ≥ 11 demonstrated a significantly higher occurrence of clinical relapse (P= 0.001) and EBD (P= 0.002) within 5 years. Patients with US-CD ≥ 6 experienced a significantly higher likelihood of requiring enhanced treatment (P< 0.001) within 5 years.
Conclusions
High US-CD is associated with subsequent adverse outcomes in patients with CD.
2.Characteristics and usefulness of transabdominal ultrasonography in immune-mediated colitis
Kensuke SAKURAI ; Takehiko KATSURADA ; Mutsumi NISHIDA ; Satomi OMOTEHARA ; Shinya FUKUSHIMA ; Shinsuke OTAGIRI ; Kazunori NAGASHIMA ; Reizo ONISHI ; Ryo TAKAGI ; Yoshito KOMATSU ; Naoya SAKAMOTO
Intestinal Research 2023;21(1):126-136
Background/Aims:
The usefulness of ultrasonography (US) in diseases of the gastrointestinal tract has been reported recently. This prospective study aimed to determine the features of US findings in immune-mediated colitis (IMC), an adverse event induced by immune checkpoint inhibitor, and examine the correlation between US findings, colonoscopy (CS) findings, and severity of colitis.
Methods:
We studied patients examined using CS and US upon suspicion of IMC in Hokkaido University Hospital between April 2018 and February 2021. Endoscopic findings of IMC were assessed using the Ulcerative Colitis Endoscopic Index of Severity (UCEIS). The severity of US findings in IMC was evaluated using US grade, which is the ultrasonographic grading scale in ulcerative colitis. Bowel wall thickness and the intensity of the color Doppler signal were also analyzed. Severity of colitis was evaluated using Common Terminology Criteria for Adverse Events (CTCAE) grade version 5.
Results:
Fourteen patients with IMC were enrolled. The US findings were bowel wall thickening, loss of stratification, ulceration and increased blood flow signal. The US grade was moderately correlated with the UCEIS (r=0.687, p=0.009) and CTCAE grade (r=0.628, p=0.035). Bowel wall thickness and UCEIS (r=0.628, p=0.020), as well as color Doppler signal grade and CTCAE grade (r=0.724, p=0.008), were significantly correlated.
Conclusions
US findings in IMC were mainly similar to those of ulcerative colitis, but there were some findings that were characteristic only of IMC. Significant correlation was found between US findings, CS findings, and severity of colitis. Hence, US could be useful for the evaluation of IMC.
3.Endoscopic balloon dilations for strictures of rectum, ileocecal valve and duodenum in a patient with X-linked inhibitor of apoptosis deficiency: a case report
Shinsuke OTAGIRI ; Takehiko KATSURADA ; Kensuke SAKURAI ; Junichi SUGITA ; Naoya SAKAMOTO
Intestinal Research 2022;20(2):274-277
X-linked inhibitor of apoptosis (XIAP) deficiency is a rare primary immunodeficiency and gastrointestinal (GI) lesions in XIAP deficiency are similar to Crohn’s disease. For patients with Crohn’s disease, endoscopic balloon dilation (EBD) is known to be a standard procedure for intestinal strictures including upper GI tract. However, there are no articles which mention the efficacy of EBDs for the strictures in upper GI tract in patients with XIAP deficiency. Herein, we describe an 18-year-old male with XIAP deficiency in whom EBDs for the rectum, ileocecal valve (ICV), and duodenum were performed. Before hematopoietic stem cell transplantation (HSCT), GI endoscopy revealed strictures of the rectum, ICV and duodenum with active ulcers. Although these ulcers healed after HSCT, the strictures progressed. Therefore, we performed EBDs for the strictures of the rectum, ICV, and duodenum. In contrast studies, we did not find any other strictures in the small intestine. Throughout the patient’s clinical course, no complications of EBD occurred. He started eating after EBDs, but abdominal symptoms did not relapse without any dietary restrictions. Our case suggests that EBD could be an effective and safe procedure for intestinal strictures including upper GI tract after HSCT in patients with XIAP deficiency.
4.Effectiveness of administering zinc acetate hydrate to patients with inflammatory bowel disease and zinc deficiency: a retrospective observational two-center study
Kensuke SAKURAI ; Shigeru FURUKAWA ; Takehiko KATSURADA ; Shinsuke OTAGIRI ; Kana YAMANASHI ; Kazunori NAGASHIMA ; Reizo ONISHI ; Keiji YAGISAWA ; Haruto NISHIMURA ; Takahiro ITO ; Atsuo MAEMOTO ; Naoya SAKAMOTO
Intestinal Research 2022;20(1):78-89
Background/Aims:
Inflammatory bowel disease (IBD) patients frequently have zinc deficiency. IBD patients with zinc deficiency have higher risks of IBD-related hospitalization, complications, and requiring surgery. This study aimed to examine the effectiveness of zinc acetate hydrate (ZAH; Nobelzin) in IBD patients with zinc deficiency.
Methods:
IBD patients with zinc deficiency who received ZAH from March 2017 to April 2020 were registered in this two-center, retrospective, observational study. Changes in serum zinc levels and disease activity (Crohn’s Disease Activity Index [CDAI]) before and after ZAH administration were analyzed.
Results:
Fifty-one patients with Crohn’s disease (CD, n = 40) or ulcerative colitis (UC, n = 11) were registered. Median serum zinc level and median CDAI scores significantly improved (55.5–91.0 μg/dL, P< 0.001; 171.5–129, P< 0.001, respectively) in CD patients 4 weeks after starting ZAH administration. Similarly, median serum zinc levels and CDAI scores significantly improved (57.0–81.0 μg/dL, P< 0.001; 177–148, P= 0.012, respectively) 20 weeks after starting ZAH administration. Similar investigations were conducted in groups where no treatment change, other than ZAH administration, was implemented; significant improvements were observed in both serum zinc level and CDAI scores. Median serum zinc levels in UC patients 4 weeks after starting ZAH administration significantly improved from 63.0 to 94.0 μg/dL (P= 0.002), but no significant changes in disease activity were observed. One patient experienced side effects of abdominal discomfort and nausea.
Conclusions
ZAH administration is effective in improving zinc deficiency and may contribute to improving disease activity in IBD.
5.Nosocomial outbreak of coronavirus disease in two general wards during the initial wave of the pandemic in 2020, Tokyo, Japan
Naoya Sakamoto ; Masayuki Ota ; Tomoko Takeda ; Atsushi Kosaka ; Takuya Washino ; Sentaro Iwabuchi ; Minako Beppu ; Itaru Nishiduka ; Tamano Matsui ; Motoi Suzuki ; Fukumi Nakamura-Uchiyama
Western Pacific Surveillance and Response 2022;13(1):38-42
Objective:
Coronavirus disease 2019 (COVID-19), caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), was first reported in China and subsequently spread worldwide. In Japan, many clusters occurred during the first wave in 2020. We describe the investigation of an early outbreak in a Tokyo hospital.
Methods:
A COVID-19 outbreak occurred in two wards of the hospital from April to early May 2020. Confirmed cases were individuals with laboratory-confirmed SARS-CoV-2 infection linked to Wards A and B, and contacts were patients or workers in Wards A or B 2 weeks before the index cases developed symptoms. All contacts were tested, and cases were interviewed to determine the likely route of infection and inform the development of countermeasures to curb transmission.
Results:
There were 518 contacts, comprising 472 health-care workers (HCWs) and 46 patients, of whom 517 were tested. SARS-CoV-2 infection was confirmed in 42 individuals (30 HCWs and 12 patients). The proportions of SARS-CoV-2 infections in HCWs were highest among surgeons, nurses, nursing assistants and medical assistants. Several HCWs in these groups reported being in close proximity to one another while not wearing medical masks. Among HCWs, infection was thought to be associated with the use of a small break room and conference room.
Discussion
Nosocomial SARS-CoV-2 infections occurred in two wards of a Tokyo hospital, affecting HCWs and patients. Not wearing masks was considered a key risk factor for infection during this outbreak; masks are now a mandated countermeasure to prevent the spread of SARS-CoV-2 infection in hospital settings.
6.A Prospective Multicenter Study Evaluating Bleeding Risk after Endoscopic Ultrasound-Guided Fine Needle Aspiration in Patients Prescribed Antithrombotic Agents.
Kazumichi KAWAKUBO ; Kei YANE ; Kazunori ETO ; Hirotoshi ISHIWATARI ; Nobuyuki EHIRA ; Shin HABA ; Ryusuke MATSUMOTO ; Keisuke SHINADA ; Hiroaki YAMATO ; Taiki KUDO ; Manabu ONODERA ; Toshinori OKUDA ; Yoko TAYA-ABE ; Shuhei KAWAHATA ; Kimitoshi KUBO ; Yoshimasa KUBOTA ; Masaki KUWATANI ; Hiroshi KAWAKAMI ; Akio KATANUMA ; Michihiro ONO ; Tsuyoshi HAYASHI ; Minoru UEBAYASHI ; Naoya SAKAMOTO
Gut and Liver 2018;12(3):353-359
BACKGROUND/AIMS: Although the risk of bleeding after endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is low, the safety of EUS-FNA in patients prescribed antithrom-botic agents is unclear. Therefore, this study evaluated the incidence of bleeding after EUS-FNA in those patients. METHODS: Between September 2012 and September 2015, patients who were prescribed antithrombotic agents underwent EUS-FNA at 13 institutions in Japan were prospectively enrolled in the study. The antithrombotic agents were managed according to the guidelines of the Japanese Gastrointestinal Endoscopy Society. The rate of bleeding events, thromboembolic events and other complications within 2 weeks after EUS-FNA were analyzed. RESULTS: Of the 2,629 patients who underwent EUS-FNA during the study period, 85 (62 males; median age, 74 years) patients were included in this stduy. Two patients (2.4%; 95% confidence interval [CI], 0.6% to 8.3%) experienced bleeding events. One patient required surgical intervention for hemothorax 5 hours after EUS-FNA, and the other experienced melena 8 days after EUS-FNA and required red blood cell transfusions. No thromboembolic events occurred (0%; 95% CI, 0.0% to 4.4%). Three patients (3.5%; 95% CI, 1.2% to 10.0%) experienced peri-puncture abscess formation. CONCLUSIONS: The rate of bleeding after EUS-FNA in patients prescribed antithrombotic agents might be considerable.
Abscess
;
Asian Continental Ancestry Group
;
Endoscopic Ultrasound-Guided Fine Needle Aspiration*
;
Endoscopy, Gastrointestinal
;
Erythrocyte Transfusion
;
Fibrinolytic Agents*
;
Hemorrhage*
;
Hemothorax
;
Humans
;
Incidence
;
Japan
;
Male
;
Melena
;
Prospective Studies*
7.Combined use of a two-channel endoscope and a flexible tip catheter for difficult biliary cannulation
Masaki KUWATANI ; Yoshimasa KUBOTA ; Shuhei KAWAHATA ; Kimitoshi KUBO ; Kazumichi KAWAKUBO ; Hiroshi KAWAKAMI ; Naoya SAKAMOTO
Gastrointestinal Intervention 2018;7(1):34-35
A 69-year-old woman with jaundice was referred to our hospital. After a final diagnosis of pancreatic cancer with liver metastasis, we performed transpapillary biliary drainage with a covered self-expandable metal stent (SEMS). Three months later, we also placed an uncovered duodenal stent for duodenal stricture in a side-to-end fashion. Another month later, for biliary SEMS obstruction, we attempted a transpapillary approach. A duodenoscope was advanced and a guidewire was passed through the mesh of the duodenal stent into the bile duct with a flexible tip catheter, but the catheter was not. Thus, we exchanged the duodenoscope for a forward-viewing two-channel endoscope and used the left working channel with a flexible tip catheter. By adjusting the axis, we finally succeeded biliary cannulation and accomplished balloon cleaning for recanalization of the SEMS. This is the first case with successful biliary cannulation by combined use of a two-channel endoscope and a flexible tip catheter.
Aged
;
Bile Ducts
;
Catheterization
;
Catheters
;
Cholestasis
;
Constriction, Pathologic
;
Diagnosis
;
Drainage
;
Duodenoscopes
;
Endoscopes
;
Female
;
Humans
;
Jaundice
;
Liver
;
Neoplasm Metastasis
;
Pancreatic Neoplasms
;
Stents
9.Efficacy and Safety of Bolus 5-Fluorouracil and L-Leucovorin as Salvage Chemotherapy for Oral Fluoropyrimidine-Resistant Unresectable or Recurrent Gastric Cancer: A Single Center Experience.
Tetsuhito MURANAKA ; Satoshi YUKI ; Yoshito KOMATSU ; Kentaro SAWADA ; Kazuaki HARADA ; Yasuyuki KAWAMOTO ; Hiroshi NAKATSUMI ; Naoya SAKAMOTO
Journal of Gastric Cancer 2016;16(3):177-181
PURPOSE: The International Organization for Standardization-5fluorouracil (FU) 10 trial found that bolus 5-FU and l-leucovorin was not inferior to S-1 in the treatment of gastric cancer (GC). Continuous 5-FU and the rapid injection of 5-FU have different anti-cancer effects. Thus, bolus 5-FU and l-leucovorin treatment might be useful for oral FU-resistant GC. MATERIALS AND METHODS: We retrospectively analyzed the medical records of all patients with S-1 or capecitabine-resistant, unresectable, or recurrent GC treated with bolus 5-FU and l-leucovorin between January 2010 and December 2015 at Hokkaido University Hospital. The bolus 5-FU and l-leucovorin regimen consisted of intravenous l-leucovorin (250 mg/m²/2 h) and bolus 5-FU (600 mg/m²) administered once weekly followed by a 2-week rest period; each cycle was repeated every 8 weeks. RESULTS: A total of 14 patients were identified. The disease control rate was 35.7%. The median progression-free survival was 1.6 months (95% confidence interval [CI], 1.3~2.0 months), and the median overall survival was 6.3 months (95% CI, 4.7~7.9 months). No patient died from treatment-related causes. The most common severe adverse event associated with bolus 5-FU and l-leucovorin was neutropenia, which occurred in 21.4% of patients. CONCLUSIONS: Bolus 5-FU and l-leucovorin treatment might be useful for oral FU-resistant GC. We are planning a multi-center prospective phase II trial to evaluate the efficacy and safety of bolus 5-FU and l-leucovorin treatment for pre-treated unresectable or recurrent GC to confirm the results of this limited, retrospective study.
Disease-Free Survival
;
Drug Therapy*
;
Fluorouracil*
;
Humans
;
Leucovorin
;
Medical Records
;
Neutropenia
;
Prospective Studies
;
Retrospective Studies
;
Stomach Neoplasms*
10.A Unique Use of a Double-Pigtail Plastic Stent: Correction of Kinking of the Common Bile Duct Due to a Metal Stent.
Masaki KUWATANI ; Hiroshi KAWAKAMI ; Yoko ABE ; Shuhei KAWAHATA ; Kazumichi KAWAKUBO ; Kimitoshi KUBO ; Naoya SAKAMOTO
Gut and Liver 2015;9(2):251-252
A 72-year-old man with jaundice by ampullary adenocarcinoma was treated at our hospital. For biliary decompression, a transpapillary, fully covered, self-expandable metal stent (FCSEMS) was deployed. Four days later, the patient developed acute cholangitis. Endoscopic carbon dioxide cholangiography revealed kinking of the common bile duct above the proximal end of the FCSEMS. A 7-F double-pigtail plastic stent was therefore placed through the FCSEMS to correct the kink, straightening the common bile duct (CBD) and improving cholangitis. This is the first report of a unique use of a double-pigtail plastic stent to correct CBD kinking. The placement of a double-pigtail plastic stent can correct CBD kinking, without requiring replacement or addition of a FCSEMS, and can lead to cost savings.
Aged
;
Common Bile Duct/*injuries
;
Constriction, Pathologic/surgery
;
Decompression, Surgical/instrumentation/methods
;
Humans
;
Male
;
Self Expandable Metallic Stents/adverse effects
;
*Stents
;
Torsion Abnormality/*surgery


Result Analysis
Print
Save
E-mail