1.Prevalence and Associated Factors of Depression and Anxiety Among Healthcare Workers During the Coronavirus Disease 2019 Pandemic:A Nationwide Study in Korea
Shinwon LEE ; Soyoon HWANG ; Ki Tae KWON ; EunKyung NAM ; Un Sun CHUNG ; Shin-Woo KIM ; Hyun-Ha CHANG ; Yoonjung KIM ; Sohyun BAE ; Ji-Yeon SHIN ; Sang-geun BAE ; Hyun Wook RYOO ; Juhwan JEONG ; NamHee OH ; So Hee LEE ; Yeonjae KIM ; Chang Kyung KANG ; Hye Yoon PARK ; Jiho PARK ; Se Yoon PARK ; Bongyoung KIM ; Hae Suk CHEONG ; Ji Woong SON ; Su Jin LIM ; Seongcheol YUN ; Won Sup OH ; Kyung-Hwa PARK ; Ju-Yeon LEE ; Sang Taek HEO ; Ji-yeon LEE
Journal of Korean Medical Science 2024;39(13):e120-
Background:
A healthcare system’s collapse due to a pandemic, such as the coronavirus disease 2019 (COVID-19), can expose healthcare workers (HCWs) to various mental health problems. This study aimed to investigate the impact of the COVID-19 pandemic on the depression and anxiety of HCWs.
Methods:
A nationwide questionnaire-based survey was conducted on HCWs who worked in healthcare facilities and public health centers in Korea in December 2020. Patient Health Questionnaire-9 (PHQ-9) and Generalized Anxiety Disorder-7 (GAD-7) were used to measure depression and anxiety. To investigate factors associated with depression and anxiety, stepwise multiple logistic regression analysis was performed.
Results:
A total of 1,425 participating HCWs were included. The mean depression score (PHQ-9) of HCWs before and after COVID-19 increased from 2.37 to 5.39, and the mean anxiety score (GAD-7) increased from 1.41 to 3.41. The proportion of HCWs with moderate to severe depression (PHQ-9 ≥ 10) increased from 3.8% before COVID-19 to 19.5% after COVID-19, whereas that of HCWs with moderate to severe anxiety (GAD-7 ≥ 10) increased from 2.0% to 10.1%. In our study, insomnia, chronic fatigue symptoms and physical symptoms after COVID-19, anxiety score (GAD-7) after COVID-19, living alone, and exhaustion were positively correlated with depression. Furthermore, post-traumatic stress symptoms, stress score (Global Assessment of Recent Stress), depression score (PHQ-9) after COVID-19, and exhaustion were positively correlated with anxiety.
Conclusion
In Korea, during the COVID-19 pandemic, HCWs commonly suffered from mental health problems, including depression and anxiety. Regularly checking the physical and mental health problems of HCWs during the COVID-19 pandemic is crucial, and social support and strategy are needed to reduce the heavy workload and psychological distress of HCWs.
2.False positive cases in automated blood culture systems due to hyperleukocytosis: a case report
Annals of Clinical Microbiology 2023;26(2):37-40
Automated blood culture systems are widely used in clinical microbiology laboratories to minimize the workload of laboratory personnel and permit fast turnaround times. However, sometimes false positive signals occur due to leukocytosis, presence of fastidious bacteria, or unexplained causes. We experienced false positive signal in a patient with hyperleukocytosis for the first time since the automated blood culture system was introduced in our hospital over 20 years ago. We present two case reports with literature review and describe the procedure for dealing with false-positive cases in our hospital.
3.Serotype Distribution and Antimicrobial Resistance of Streptococcus pneumoniae Causing Invasive Pneumococcal Disease in Korea Between 2017 and 2019 After Introduction of the 13-Valent Pneumococcal Conjugate Vaccine
Gyu Ri KIM ; Eun-Young KIM ; Si Hyun KIM ; Hae Kyung LEE ; Jaehyeon LEE ; Jong Hee SHIN ; Young Ree KIM ; Sae Am SONG ; Joseph JEONG ; Young UH ; Yu Kyung KIM ; Dongeun YONG ; Hyun Soo KIM ; Sunjoo KIM ; Young Ah KIM ; Kyeong Seob SHIN ; Seok Hoon JEONG ; Namhee RYOO ; Jeong Hwan SHIN
Annals of Laboratory Medicine 2023;43(1):45-54
Background:
Streptococcus pneumoniae is a serious pathogen causing various infections in humans. We evaluated the serotype distribution and antimicrobial resistance of S. pneumoniae causing invasive pneumococcal disease (IPD) after introduction of pneumococcal conjugate vaccine (PCV)13 in Korea and investigated the epidemiological characteristics of multidrug-resistant (MDR) isolates.
Methods:
S. pneumoniae isolates causing IPD were collected from 16 hospitals in Korea between 2017 and 2019. Serotyping was performed using modified sequential multiplex PCR and the Quellung reaction. Antimicrobial susceptibility tests were performed using the broth microdilution method. Multilocus sequence typing was performed on MDR isolates for epidemiological investigations.
Results:
Among the 411 S. pneumoniae isolates analyzed, the most prevalent serotype was 3 (12.2%), followed by 10A (9.5%), 34 (7.3%), 19A (6.8%), 23A (6.3%), 22F (6.1%), 35B (5.8%), 11A (5.1%), and others (40.9%). The coverage rates of PCV7, PCV10, PCV13, and pneumococcal polysaccharide vaccine (PPSV)23 were 7.8%, 7.8%, 28.7%, and 59.4%, respectively. Resistance rates to penicillin, ceftriaxone, erythromycin, and levofloxacin were 13.1%, 9.2%, 80.3%, and 4.1%, respectively. MDR isolates accounted for 23.4% of all isolates. Serotypes 23A, 11A, 19A, and 15B accounted for the highest proportions of total isolates at 18.8%, 16.7%, 14.6%, and 8.3%, respectively. Sequence type (ST)166 (43.8%) and ST320 (12.5%) were common among MDR isolates.
Conclusions
Non-PCV13 serotypes are increasing among invasive S. pneumoniae strains causing IPD. Differences in antimicrobial resistance were found according to the specific serotype. Continuous monitoring of serotypes and antimicrobial resistance is necessary for the appropriate management of S. pneumoniae infections.
4.Guidelines for the Laboratory Diagnosis of Monkeypox in Korea
Ki Ho HONG ; Gab Jung KIM ; Kyoung Ho ROH ; Hyukmin LEE ; Ok Kyu PARK ; Taek Soo KIM ; Jae-Seok KIM ; Jaehyeon LEE ; Moon-Woo SEONG ; So Yeon KIM ; Jae-Sun PARK ; Younhee PARK ; Hee Jae HUH ; Namhee RYOO ; Hyun Soo KIM ; Heungsup SUNG ; Cheon Kwon YOO ;
Annals of Laboratory Medicine 2023;43(2):137-144
While the coronavirus disease 2019 pandemic is ongoing, monkeypox has been rapidly spreading in non-endemic countries since May 2022. Accurate and rapid laboratory tests are essential for identifying and controlling monkeypox. Korean Society for Laboratory Medicine and the Korea Disease Prevention and Control Agency have proposed guidelines for diagnosing monkeypox in clinical laboratories in Korea. These guidelines cover the type of tests, selection of specimens, collection of specimens, diagnostic methods, interpretation of test results, and biosafety. Molecular tests are recommended as confirmatory tests. Skin lesion specimens are recommended for testing in the symptomatic stage, and the collection of both blood and oropharyngeal swabs is recommended in the presymptomatic or prodromal stage.
5.Erratum: COVID-19 Molecular Testing in Korea:Practical Essentials and Answers From Experts Based on Experiences of Emergency Use Authorization Assays
Heungsup SUNG ; Kyoung Ho ROH ; Ki Ho HONG ; Moon-Woo SEONG ; Namhee RYOO ; Hyun Soo KIM ; Jaehyeon LEE ; So Yeon KIM ; Sook Won RYU ; Mi-Na KIM ; Myung Guk HAN ; Sang Won LEE ; Hyukmin LEE ; Cheon Kwon YOO ;
Annals of Laboratory Medicine 2021;41(1):126-127
6.Two Cases of Successful Plasma Exchange with Unfractionated Heparin Anticoagulation in Patients Exhibiting Anaphylaxis to Acid-citrate-dextrose Formula A
Hyein KANG ; Do-Hoon KIM ; Dong-Seok JEON ; Wonmok LEE ; Namhee RYOO ; Jungsook HA
Korean Journal of Blood Transfusion 2020;31(1):55-60
Plasma exchange performed with the aid of acid-citrate-dextrose formula A (ACD-A) is generally regarded as safe. However, unfractionated heparin (UFH) can serve as an anticoagulant for patients experiencing serious side effects such as anaphylaxis. No guidelines have currently been defined for the stand-alone UFH dosing during plasma exchange. We describe here two patients who developed anaphylaxis to ACD-A during plasma exchange, and we successfully used UFH as a standalone anticoagulant. The first patient was a 55-year-old man who required plasma exchange before ABO-incompatible kidney transplantation. During plasma exchange, he developed an allergic reaction. Thereafter, UFH was used as a standalone anticoagulant during four sessions of plasma exchange; the UFH (5,000 units) was added to a 500 mL normal saline bag and the UFH:whole blood ratio was maintained at 1:28. The second patient was an 80-year-old woman with steroid pulse-resistant neuromyelitis optica. She developed an allergic reaction during the first session of plasma exchange. The patient subsequently underwent five successful sessions of plasma exchange using UFH as a standalone anticoagulant. These findings may be useful when establishing a protocol for UFH as a standalone anticoagulant during plasma exchange in patients who develop an allergic reaction to citrate.
7.Correlation Between C3d Assay and Single Antigen Bead Assay for Detection of Human Leukocyte Antigen Class II Antibodies
Hyein KANG ; Do-Hoon KIM ; Jung Sook HA ; Namhee RYOO ; Dong-Seok JEON ; Wonmok LEE
Laboratory Medicine Online 2020;10(4):295-300
Background:
Detection of anti-human leukocyte antigen (HLA) antibodies is important during the selection of an appropriate donor prior to organ transplantation and also for monitoring the patients after transplantation. In this study, we compared antibodies detected via C3d assays, which monitors C3d complement-binding activities of HLA antibodies with those detected via single antigen bead (SAB) assays.
Methods:
A total of 66 serum samples were tested in parallel by SAB assays (Immucor Transplant Diagnostics, USA) and C3d assays (Immucor) for the detection of HLA class II antibodies. The relationship between these two methods was analyzed based on the types, numbers, median fluorescent intensity (MFI) values, and positivity of the antibodies using MATCH IT! Antibody (Immucor) program.
Results:
The number of antibodies obtained based on SAB and C3d assays was the highest with 24 samples (36.4%) in the 11–20 range and 23 (34.8%) in the 2–5 range detected via each assay. Among the SAB-positive antibodies, only 28 (6.4%) of the 440 antibodies with MFI ≤3,000 were C3d-positive, and 341 (61.3%) of the 556 antibodies with MFI ≥3,001 were C3d-positive. Whereas, among the 442 C3d-positive antibodies, SAB assays were positive except for 32 (7.2%) and 41 (9.3%) antibodies in the sections of MFI ≤500 and 1,001 ≤MFI ≤10,000, respectively. C3d-positive samples had higher maximum MFI values based on SAB assays, compared with C3d-negative samples.
Conclusions
MFI values of HLA class II antibodies detected through SAB assays in C3d-positive samples were higher than those in C3d-negative samples.
8.Correlation Between C3d Assay and Single Antigen Bead Assay for Detection of Human Leukocyte Antigen Class II Antibodies
Hyein KANG ; Do-Hoon KIM ; Jung Sook HA ; Namhee RYOO ; Dong-Seok JEON ; Wonmok LEE
Laboratory Medicine Online 2020;10(4):295-300
Background:
Detection of anti-human leukocyte antigen (HLA) antibodies is important during the selection of an appropriate donor prior to organ transplantation and also for monitoring the patients after transplantation. In this study, we compared antibodies detected via C3d assays, which monitors C3d complement-binding activities of HLA antibodies with those detected via single antigen bead (SAB) assays.
Methods:
A total of 66 serum samples were tested in parallel by SAB assays (Immucor Transplant Diagnostics, USA) and C3d assays (Immucor) for the detection of HLA class II antibodies. The relationship between these two methods was analyzed based on the types, numbers, median fluorescent intensity (MFI) values, and positivity of the antibodies using MATCH IT! Antibody (Immucor) program.
Results:
The number of antibodies obtained based on SAB and C3d assays was the highest with 24 samples (36.4%) in the 11–20 range and 23 (34.8%) in the 2–5 range detected via each assay. Among the SAB-positive antibodies, only 28 (6.4%) of the 440 antibodies with MFI ≤3,000 were C3d-positive, and 341 (61.3%) of the 556 antibodies with MFI ≥3,001 were C3d-positive. Whereas, among the 442 C3d-positive antibodies, SAB assays were positive except for 32 (7.2%) and 41 (9.3%) antibodies in the sections of MFI ≤500 and 1,001 ≤MFI ≤10,000, respectively. C3d-positive samples had higher maximum MFI values based on SAB assays, compared with C3d-negative samples.
Conclusions
MFI values of HLA class II antibodies detected through SAB assays in C3d-positive samples were higher than those in C3d-negative samples.
9.Experience at Department of Laboratory Medicine during the COVID-19 Outbreak in Daegu
Sunggyun PARK ; Do-Hoon KIM ; Won-Mok LEE ; Ung-Sook HA ; Dong-Seok JEON ; Jae-Hee LEE ; Namhee RYOO
Annals of Clinical Microbiology 2020;23(4):225-231
The first case of coronavirus disease 2019 (COVID-19) in Korea was reported in January 2020.As the secondary transmissions accelerated within the country, the government revised the outbreak alert for COVID-19 from attention to caution. Mid-February, when a massive outbreak was reported from a church in Daegu, our institution initiated testing for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). More than 300 laboratory tests were performed within the first 2 months, before the number of cases began to decline. Here, we describe our experience of 4 months at the department of Laboratory Medicine, Keimyung University Dongsan Hospital, located in Daegu, where a massive COVID-19 outbreak occurred.
10.COVID-19 Molecular Testing in Korea: Practical Essentials and Answers From Experts Based on Experiences of Emergency Use Authorization Assays
Heungsup SUNG ; Kyoung Ho ROH ; Ki Ho HONG ; Moon-Woo SEONG ; Namhee RYOO ; Hyun Soo KIM ; Jaehyeon LEE ; So Yeon KIM ; Sookwon YOO ; Mi-Na KIM ; Myung Guk HAN ; Sang Won LEE ; Hyukmin LEE ; Cheon Kwon YOO ;
Annals of Laboratory Medicine 2020;40(6):439-447

Result Analysis
Print
Save
E-mail