1.Guideline for Minimizing Radiation Exposure of Interventionalists during Fluoroscopy-guided Interventional Procedures
Il Sang SHIN ; Yun Nah LEE ; Jun Kyu LEE ; Joo Seong KIM ; Sung Bum KIM ; Jiyoung KEUM ; Chang Hoon OH ; Kang Won LEE ; Joowon CHUNG ; Lyo Min KWON ; Nam Hee KIM ; Sang Soo LEE ; Byoung Kwan SON ; Miyoung CHOI
The Korean Journal of Gastroenterology 2024;84(6):251-264
As fluoroscopy-guided interventional procedures gain popularity, the associated health threats from radiation exposure to interventionalists during these procedures are increasing. Therefore, an understanding of the potential risks of radiation and careful consideration on minimizing exposure to radiation during the procedures are of paramount importance. The Korean Pancreatobiliary Association has developed a clinical practice guideline to minimize radiation exposure during fluoroscopy-guided interventional procedures. This guideline provides recommendations to deal with the risk of radiation exposure to interventionalists who perform fluoroscopy-guided procedures, and emphasizes the importance of proper and practical approaches to avoid unnecessary radiation exposure.
2.Guideline for Minimizing Radiation Exposure of Interventionalists during Fluoroscopy-guided Interventional Procedures
Il Sang SHIN ; Yun Nah LEE ; Jun Kyu LEE ; Joo Seong KIM ; Sung Bum KIM ; Jiyoung KEUM ; Chang Hoon OH ; Kang Won LEE ; Joowon CHUNG ; Lyo Min KWON ; Nam Hee KIM ; Sang Soo LEE ; Byoung Kwan SON ; Miyoung CHOI
The Korean Journal of Gastroenterology 2024;84(6):251-264
As fluoroscopy-guided interventional procedures gain popularity, the associated health threats from radiation exposure to interventionalists during these procedures are increasing. Therefore, an understanding of the potential risks of radiation and careful consideration on minimizing exposure to radiation during the procedures are of paramount importance. The Korean Pancreatobiliary Association has developed a clinical practice guideline to minimize radiation exposure during fluoroscopy-guided interventional procedures. This guideline provides recommendations to deal with the risk of radiation exposure to interventionalists who perform fluoroscopy-guided procedures, and emphasizes the importance of proper and practical approaches to avoid unnecessary radiation exposure.
3.Guideline for Minimizing Radiation Exposure of Interventionalists during Fluoroscopy-guided Interventional Procedures
Il Sang SHIN ; Yun Nah LEE ; Jun Kyu LEE ; Joo Seong KIM ; Sung Bum KIM ; Jiyoung KEUM ; Chang Hoon OH ; Kang Won LEE ; Joowon CHUNG ; Lyo Min KWON ; Nam Hee KIM ; Sang Soo LEE ; Byoung Kwan SON ; Miyoung CHOI
The Korean Journal of Gastroenterology 2024;84(6):251-264
As fluoroscopy-guided interventional procedures gain popularity, the associated health threats from radiation exposure to interventionalists during these procedures are increasing. Therefore, an understanding of the potential risks of radiation and careful consideration on minimizing exposure to radiation during the procedures are of paramount importance. The Korean Pancreatobiliary Association has developed a clinical practice guideline to minimize radiation exposure during fluoroscopy-guided interventional procedures. This guideline provides recommendations to deal with the risk of radiation exposure to interventionalists who perform fluoroscopy-guided procedures, and emphasizes the importance of proper and practical approaches to avoid unnecessary radiation exposure.
4.Guideline for Minimizing Radiation Exposure of Interventionalists during Fluoroscopy-guided Interventional Procedures
Il Sang SHIN ; Yun Nah LEE ; Jun Kyu LEE ; Joo Seong KIM ; Sung Bum KIM ; Jiyoung KEUM ; Chang Hoon OH ; Kang Won LEE ; Joowon CHUNG ; Lyo Min KWON ; Nam Hee KIM ; Sang Soo LEE ; Byoung Kwan SON ; Miyoung CHOI
The Korean Journal of Gastroenterology 2024;84(6):251-264
As fluoroscopy-guided interventional procedures gain popularity, the associated health threats from radiation exposure to interventionalists during these procedures are increasing. Therefore, an understanding of the potential risks of radiation and careful consideration on minimizing exposure to radiation during the procedures are of paramount importance. The Korean Pancreatobiliary Association has developed a clinical practice guideline to minimize radiation exposure during fluoroscopy-guided interventional procedures. This guideline provides recommendations to deal with the risk of radiation exposure to interventionalists who perform fluoroscopy-guided procedures, and emphasizes the importance of proper and practical approaches to avoid unnecessary radiation exposure.
5.Guideline for Minimizing Radiation Exposure of Interventionalists during Fluoroscopy-guided Interventional Procedures
Il Sang SHIN ; Yun Nah LEE ; Jun Kyu LEE ; Joo Seong KIM ; Sung Bum KIM ; Jiyoung KEUM ; Chang Hoon OH ; Kang Won LEE ; Joowon CHUNG ; Lyo Min KWON ; Nam Hee KIM ; Sang Soo LEE ; Byoung Kwan SON ; Miyoung CHOI
The Korean Journal of Gastroenterology 2024;84(6):251-264
As fluoroscopy-guided interventional procedures gain popularity, the associated health threats from radiation exposure to interventionalists during these procedures are increasing. Therefore, an understanding of the potential risks of radiation and careful consideration on minimizing exposure to radiation during the procedures are of paramount importance. The Korean Pancreatobiliary Association has developed a clinical practice guideline to minimize radiation exposure during fluoroscopy-guided interventional procedures. This guideline provides recommendations to deal with the risk of radiation exposure to interventionalists who perform fluoroscopy-guided procedures, and emphasizes the importance of proper and practical approaches to avoid unnecessary radiation exposure.
6.Guideline for Minimizing Radiation Exposure of Interventionalists during Fluoroscopy-Guided Interventional Procedures
Il Sang SHIN ; Yun Nah LEE ; Jun Kyu LEE ; Joo Seong KIM ; Sung Bum KIM ; Jiyoung KEUM ; Chang Hoon OH ; Kang Won LEE ; Joowon CHUNG ; Lyo Min KWON ; Nam Hee KIM ; Sang Soo LEE ; Byoung Kwan SON ; Miyoung CHOI
Korean Journal of Pancreas and Biliary Tract 2024;29(3):69-84
As fluoroscopy-guided interventional procedures gain popularity, the associated health threats from radiation exposure to interventionalists during these procedures are increasing. Therefore, an understanding of the potential risks of radiation and careful consideration on minimizing exposure to radiation during the procedures are of paramount importance. The Korean Pancreatobiliary Association has developed a clinical practice guideline to minimize radiation exposure during fluoroscopy-guided interventional procedures. This guideline provides recommendations to deal with the risk of radiation exposure to interventionalists who perform fluoroscopy-guided procedures, and emphasizes the importance of proper and practical approaches to avoid unnecessary radiation exposure.
7.A Comparative Study on Aqueous Chitosan Solution and Various Submucosal Injection Fluids Using a Three-Dimensional Sensor
Han Jo JEON ; Seung JEONG ; Hyuk Soon CHOI ; Se Hyun JANG ; Sang Hoon KIM ; Seung Han KIM ; Jae Min LEE ; Eun Sun KIM ; Bora KEUM ; Yoon Tae JEEN ; Hong Sik LEE ; Hoon Jai CHUN ; Jong Hoon CHUNG ; Seong Nam KIM
Gut and Liver 2021;15(2):217-224
Background/Aims:
Chitosan, a natural polymer widely used in the biomaterials field, has been proposed as a potential submucosal injection solution. The purpose of this study was to compare the performance and efficacy of aqueous chitosan solution and commercialized submucosal injection fluids using a three-dimensional sensor and to evaluate the efficacy of the measured parameters.
Methods:
Normal saline (0.9% NaCl), as a control, Eleview ® (Poloxamer 188), Blue Eye TM (0.4% hyaluronic acid), and aqueous chitosan solution (2.0%) were injected into the submucosa of porcine stomachs ex vivo. The mucosal elevation height, elevated surface area, and angle of the tangent of the submucosal fluid cushion were measured using a three-dimensional sensor. The rates of change for each variable were calculated, and the correlation between parameters was analyzed. Tissue specimens were stained with hematoxylin and eosin.
Results:
All variables exhibited the highest values under chitosan injection. The mucosal elevation height rate of change differed significantly between normal saline and chitosan solution (p=0.024). The elevated surface area rates of change for normal saline and Eleview® were significantly different from those for TS-905 and chitosan solution (p=0.006 and p=0.009, respectively). Further, height, area, and angle showed a positive correlation (p<0.001). A histological examination revealed an even distribution of aqueous chitosan within the submucosa without tissue damage.
Conclusions
Aqueous chitosan was superior to normal saline and Eleview® and was noninferior to TS-905. A three-dimensional sensor and the measured parameters were effective and useful for evaluating the performance of submucosal fluids.
8.Incidence Rate and Characteristics of Falls in Patients Using Comprehensive Nursing Care Service
Jaei SON ; Byung Kyu PARK ; Chan Hee LEE ; Keum Hui AHN ; Jung Nam KIM ; Min Hyun PARK ; Eun Young CHOI ; Eun Hui BOO ; Min Jin KANG ; Jung Hwa HONG
Health Policy and Management 2019;29(2):172-183
BACKGROUND: Falls are the most frequent adverse events reported in hospitals. The aim of this study was to investigate the incidence rate and characteristics of falls in patients who used comprehensive nursing care service in National Health Insurance Service Ilsan Hospital. METHODS: Incidence rate of falls was investigated in patients using comprehensive nursing care service, from July 2013 to Jun 2017 and compared with those not using this service. The characteristics and risk factors for falls, and fall-related injuries were obtained. RESULTS: Among the 62,445 patients who used the comprehensive nursing care service for 4 years, total of 672 falls were reported. The incidence rate of falls per 1,000 patients-day was 1.15. The percentage of fall-related injuries was 26.9% and that of major injury was 2.2%. Although the incidence rate of all falls was slightly higher in patients using comprehensive nursing care service than those not using this service, falls-related injuries were not correlated with the implementation of this service. CONCLUSION: The falls could be more frequently detected and reported in comprehensive nursing care service, but there was no difference in fall-related injuries.
Accidental Falls
;
Humans
;
Incidence
;
National Health Programs
;
Nursing Care
;
Nursing
;
Risk Factors
9.Expression of Hepatocyte Hepatitis B Core Antigen and Hepatitis B Surface Antigen as a Marker in the Management of Chronic Hepatitis B Patients.
Sun Young YIM ; Tae Hyung KIM ; Suh Sang JUN ; Eun Sun KIM ; Bora KEUM ; Yeon Seok SEO ; Hyung Joon YIM ; Yoon Tae JEEN ; Hoon Jai CHUN ; Hong Sik LEE ; Soon Ho UM ; Chang Duck KIM ; Nam Hee WON ; Ho Sang RYU
Gut and Liver 2017;11(3):417-425
BACKGROUND/AIMS: We aimed to clarify the association of hepatitis B surface antigen (HBsAg)/hepatitis B core antigen (HBcAg) with the disease status and treatment response in patients with chronic hepatitis B (CHB). METHODS: We investigated 171 biopsy-proven entecavir-treated CHB patients (109 hepatitis B e antigen [HBeAg]-positive, 62 HBeAg-negative). HBcAg expression was positive when ≥10% of hepatocytes stained, and classified into nuclear, mixed, and cytoplasmic patterns. HBsAg expressions were intracytoplasmic (diffuse, globular, and submembranous) and membranous. The histologic activity index (HAI) and fibrosis stage followed Ishak system. RESULTS: In HBeAg-positive patients, older age, increased HAI score, advanced fibrosis, and reduced viral load were observed when HBcAg expression shifted from nucleus to cytoplasm in HBcAg-positive patients, and HBsAg expression from non-submembranous to submembranous in HBcAg-negative patients (all, p<0.05). In HBeAg-negative patients, only intracytoplasmic HBsAg expression patterns had clinical relevance with decreased ALT levels and viremia. In HBeAg-positive patients without favorable predictors of virologic response, negative HBcAg and membranous HBsAg expression predicted greater virologic response (both, p<0.05). The probability of HBeAg seroclearance was higher in patients with increased HAI or lacking HBcAg expression (both, p<0.05). Higher serum HBsAg levels and hepatocyte HBcAg positivity were associated with reduced serum HBsAg during first and post-first year treatment, respectively (both, p<0.05). CONCLUSIONS: Hepatocyte HBcAg/HBsAg expression is a good marker for disease status and predicting treatment response.
Cytoplasm
;
Fibrosis
;
Hepatitis B Core Antigens*
;
Hepatitis B e Antigens
;
Hepatitis B Surface Antigens*
;
Hepatitis B*
;
Hepatitis B, Chronic*
;
Hepatitis*
;
Hepatitis, Chronic*
;
Hepatocytes*
;
Humans
;
Viral Load
;
Viremia
10.Quality Indicators for Small Bowel Capsule Endoscopy.
Ki Nam SHIM ; Seong Ran JEON ; Hyun Joo JANG ; Jinsu KIM ; Yun Jeong LIM ; Kyeong Ok KIM ; Hyun Joo SONG ; Hyun Seok LEE ; Jae Jun PARK ; Ji Hyun KIM ; Jaeyoung CHUN ; Soo Jung PARK ; Dong Hoon YANG ; Yang Won MIN ; Bora KEUM ; Bo In LEE
Clinical Endoscopy 2017;50(2):148-160
Capsule endoscopy (CE) enables evaluation of the entire mucosal surface of the small bowel (SB), which is one of the most important steps for evaluating obscure gastrointestinal bleeding. Although the diagnostic yield of SB CE depends on many clinical factors, there are no reports on quality indicators. Thus, the Korean Gut Image Study Group (KGISG) publishes an article titled, “Quality Indicators for Small Bowel Capsule Endoscopy” under approval from the Korean Society of Gastrointestinal Endoscopy (KSGE). Herein, we initially identified process quality indicators, while the structural and outcome indicators are reserved until sufficient clinical data are accumulated. We believe that outcomes of SB CE can be improved by trying to meet our proposed quality indicators.
Capsule Endoscopy*
;
Endoscopy, Gastrointestinal
;
Hemorrhage

Result Analysis
Print
Save
E-mail