1.Comparison of intraoperative neurophysiological monitoring between propofol and remimazolam during total intravenous anesthesia in the cervical spine surgery: a prospective, double-blind, randomized controlled trial
Myoung Hwa KIM ; Jinyoung PARK ; Yoon Ghil PARK ; Yong Eun CHO ; Dawoon KIM ; Dong Jun LEE ; Kyu Wan KWAK ; Jongyun LEE ; Dong Woo HAN
Korean Journal of Anesthesiology 2025;78(1):16-29
Background:
Although total intravenous anesthesia (TIVA) with propofol and remifentanil is frequently used to optimize intraoperative neurophysiological monitoring (IONM), the exact effect of remimazolam on IONM remains unknown. Here, we compared the effects of propofol and remimazolam along with remifentanil on IONM during TIVA.
Methods:
In this prospective, double-blind, randomized controlled trial, 64 patients requiring IONM during cervical spine surgery were administered either propofol (Group P) or remimazolam (Group R). The preoperative latencies of the somatosensory-evoked potentials (SEP; N20 for the median nerve and P37 for the tibial nerve) were measured. SEP latencies and amplitudes and motor-evoked potential (MEP) amplitudes were measured 30 min after anesthetic induction (T1), 30 min after surgical incision (T2), after laminectomy or discectomy (T3), immediately after plate insertion or pedicle screw fixation (T4), and before surgical wound closure (T5). The primary outcome was the between-group difference in the N20 latency changes measured at T1 and preoperatively.
Results:
The change in SEP latencies including N20 and P37 at T1 compared with preoperative time was not significantly different between Groups P and R. Except for the amplitude of the right abductor brevis, there was no significant group-by-time interaction effect for intraoperative MEP amplitudes or SEP latencies and amplitudes.
Conclusions
TIVA with remimazolam and remifentanil for cervical spine surgery yielded stable IONM, comparable to those observed with conventional TIVA with propofol and remifentanil. Further clinical trials are needed in other surgical contexts and with more diverse patient populations to determine the effects of remimazolam on IONM.
2.Comparison of intraoperative neurophysiological monitoring between propofol and remimazolam during total intravenous anesthesia in the cervical spine surgery: a prospective, double-blind, randomized controlled trial
Myoung Hwa KIM ; Jinyoung PARK ; Yoon Ghil PARK ; Yong Eun CHO ; Dawoon KIM ; Dong Jun LEE ; Kyu Wan KWAK ; Jongyun LEE ; Dong Woo HAN
Korean Journal of Anesthesiology 2025;78(1):16-29
Background:
Although total intravenous anesthesia (TIVA) with propofol and remifentanil is frequently used to optimize intraoperative neurophysiological monitoring (IONM), the exact effect of remimazolam on IONM remains unknown. Here, we compared the effects of propofol and remimazolam along with remifentanil on IONM during TIVA.
Methods:
In this prospective, double-blind, randomized controlled trial, 64 patients requiring IONM during cervical spine surgery were administered either propofol (Group P) or remimazolam (Group R). The preoperative latencies of the somatosensory-evoked potentials (SEP; N20 for the median nerve and P37 for the tibial nerve) were measured. SEP latencies and amplitudes and motor-evoked potential (MEP) amplitudes were measured 30 min after anesthetic induction (T1), 30 min after surgical incision (T2), after laminectomy or discectomy (T3), immediately after plate insertion or pedicle screw fixation (T4), and before surgical wound closure (T5). The primary outcome was the between-group difference in the N20 latency changes measured at T1 and preoperatively.
Results:
The change in SEP latencies including N20 and P37 at T1 compared with preoperative time was not significantly different between Groups P and R. Except for the amplitude of the right abductor brevis, there was no significant group-by-time interaction effect for intraoperative MEP amplitudes or SEP latencies and amplitudes.
Conclusions
TIVA with remimazolam and remifentanil for cervical spine surgery yielded stable IONM, comparable to those observed with conventional TIVA with propofol and remifentanil. Further clinical trials are needed in other surgical contexts and with more diverse patient populations to determine the effects of remimazolam on IONM.
3.Effects of dental implant surface treated with sandblasting large grit acid-etching and femtosecond laser on implant stability, marginal bone volume, and histological results in a rabbit model
Young-Tak SON ; KeunBaDa SON ; Hoseong CHO ; Jae-Mok LEE ; Sm Abu SALEAH ; JunHo HWANG ; JongHoon LEE ; HyunDeok KIM ; Myoung-Uk JIN ; Jeehyun KIM ; Mansik JEON ; Kyu-Bok LEE
The Journal of Advanced Prosthodontics 2025;17(2):101-114
PURPOSE:
The purpose of this study was to compare the surface characteristics and healing patterns after implantation of implants treated with SLA and those treated with both SLA and femtosecond laser.
MATERIALS AND METHODS:
A total of 10 male New Zealand white rabbits were used to compare recovery levels between implants treated with SLA (SLA group) and those treated with both SLA and femtosecond laser (SF group). The implants’ surface characteristics were determined through topographic evaluation, element analysis, surface roughness, and wettability evaluation. In total, 4 implants were placed in each rabbit (2 in each tibia), with 20 implants per treatment group. Using the implant stability quotient (ISQ), marginal bone volume, and histological analysis (bone-to-implant contact (BIC), bone volume/tissue volume (BV/TV)), and post implantation outcomes were assessed. Outcome data were analyzed using independent t-tests, Mann-Whitney U tests, Wilcoxon signed-rank tests, and one-way ANOVA (α = 0.05).
RESULTS:
No significant differences were noted between SLA and SF groups in terms of ISQ, marginal bone volume, BIC, and BV/TV (P > .05). However, significant differences in ISQ were observed within each group over time (P < .05). Furthermore, significant differences were noted in the marginal bone volume of the SF group (P < .05) and the BV/TV of the SLA group between weeks 4 and 6 (P < .05).
CONCLUSION
Surface treatment via SLA and femtosecond laser is feasible compared with SLA treatment alone in terms of ISQ, marginal bone volume, BIC, and BV/TV. However, further clinical research is warranted.
4.Comparison of interference from eccentric movements of dental crowns fabricated via dynamic jaw motion tracking and conventional methods: a double-blind clinical study
Myung Hyun PARK ; Keunbada SON ; Myoung-Uk JIN ; So-Yeun KIM ; Kyu-Bok LEE
The Journal of Advanced Prosthodontics 2025;17(1):36-46
PURPOSE:
The purpose of this clinical study was to evaluate the extent of intraoral occlusal adjustment required for zirconia crowns designed with a dynamic jaw motion tracking method compared to a conventional approach.
MATERIALS AND METHODS:
Fifteen patients needing zirconia crown restorations in the anterior or posterior regions participated in this study. Following tooth preparation, dynamic jaw motion tracking records were gathered using a tracking device. These records were imported into computer-aided design software and aligned with scanned upper and lower jaw data to design each crown's occlusal surface. Two crowns were fabricated for each patient: one using motion tracking data and another without it. Crowns were scanned pre- and post-adjustment following standard protocols. The scanned data were analyzed with 3D inspection software to calculate occlusal adjustments in the segmented occlusal area as root mean square values, with a paired t-test used for statistical analysis (α = 0.05).
RESULTS:
Crowns designed with motion tracking data required significantly less intraoral occlusal adjustment than those designed conventionally (P = .028).
CONCLUSION
Dynamic jaw motion tracking in crown design reduces the extent of intraoral occlusal adjustment, potentially enhancing clinical efficiency.
5.Effects of dental implant surface treated with sandblasting large grit acid-etching and femtosecond laser on implant stability, marginal bone volume, and histological results in a rabbit model
Young-Tak SON ; KeunBaDa SON ; Hoseong CHO ; Jae-Mok LEE ; Sm Abu SALEAH ; JunHo HWANG ; JongHoon LEE ; HyunDeok KIM ; Myoung-Uk JIN ; Jeehyun KIM ; Mansik JEON ; Kyu-Bok LEE
The Journal of Advanced Prosthodontics 2025;17(2):101-114
PURPOSE:
The purpose of this study was to compare the surface characteristics and healing patterns after implantation of implants treated with SLA and those treated with both SLA and femtosecond laser.
MATERIALS AND METHODS:
A total of 10 male New Zealand white rabbits were used to compare recovery levels between implants treated with SLA (SLA group) and those treated with both SLA and femtosecond laser (SF group). The implants’ surface characteristics were determined through topographic evaluation, element analysis, surface roughness, and wettability evaluation. In total, 4 implants were placed in each rabbit (2 in each tibia), with 20 implants per treatment group. Using the implant stability quotient (ISQ), marginal bone volume, and histological analysis (bone-to-implant contact (BIC), bone volume/tissue volume (BV/TV)), and post implantation outcomes were assessed. Outcome data were analyzed using independent t-tests, Mann-Whitney U tests, Wilcoxon signed-rank tests, and one-way ANOVA (α = 0.05).
RESULTS:
No significant differences were noted between SLA and SF groups in terms of ISQ, marginal bone volume, BIC, and BV/TV (P > .05). However, significant differences in ISQ were observed within each group over time (P < .05). Furthermore, significant differences were noted in the marginal bone volume of the SF group (P < .05) and the BV/TV of the SLA group between weeks 4 and 6 (P < .05).
CONCLUSION
Surface treatment via SLA and femtosecond laser is feasible compared with SLA treatment alone in terms of ISQ, marginal bone volume, BIC, and BV/TV. However, further clinical research is warranted.
6.Comparison of interference from eccentric movements of dental crowns fabricated via dynamic jaw motion tracking and conventional methods: a double-blind clinical study
Myung Hyun PARK ; Keunbada SON ; Myoung-Uk JIN ; So-Yeun KIM ; Kyu-Bok LEE
The Journal of Advanced Prosthodontics 2025;17(1):36-46
PURPOSE:
The purpose of this clinical study was to evaluate the extent of intraoral occlusal adjustment required for zirconia crowns designed with a dynamic jaw motion tracking method compared to a conventional approach.
MATERIALS AND METHODS:
Fifteen patients needing zirconia crown restorations in the anterior or posterior regions participated in this study. Following tooth preparation, dynamic jaw motion tracking records were gathered using a tracking device. These records were imported into computer-aided design software and aligned with scanned upper and lower jaw data to design each crown's occlusal surface. Two crowns were fabricated for each patient: one using motion tracking data and another without it. Crowns were scanned pre- and post-adjustment following standard protocols. The scanned data were analyzed with 3D inspection software to calculate occlusal adjustments in the segmented occlusal area as root mean square values, with a paired t-test used for statistical analysis (α = 0.05).
RESULTS:
Crowns designed with motion tracking data required significantly less intraoral occlusal adjustment than those designed conventionally (P = .028).
CONCLUSION
Dynamic jaw motion tracking in crown design reduces the extent of intraoral occlusal adjustment, potentially enhancing clinical efficiency.
7.Effects of dental implant surface treated with sandblasting large grit acid-etching and femtosecond laser on implant stability, marginal bone volume, and histological results in a rabbit model
Young-Tak SON ; KeunBaDa SON ; Hoseong CHO ; Jae-Mok LEE ; Sm Abu SALEAH ; JunHo HWANG ; JongHoon LEE ; HyunDeok KIM ; Myoung-Uk JIN ; Jeehyun KIM ; Mansik JEON ; Kyu-Bok LEE
The Journal of Advanced Prosthodontics 2025;17(2):101-114
PURPOSE:
The purpose of this study was to compare the surface characteristics and healing patterns after implantation of implants treated with SLA and those treated with both SLA and femtosecond laser.
MATERIALS AND METHODS:
A total of 10 male New Zealand white rabbits were used to compare recovery levels between implants treated with SLA (SLA group) and those treated with both SLA and femtosecond laser (SF group). The implants’ surface characteristics were determined through topographic evaluation, element analysis, surface roughness, and wettability evaluation. In total, 4 implants were placed in each rabbit (2 in each tibia), with 20 implants per treatment group. Using the implant stability quotient (ISQ), marginal bone volume, and histological analysis (bone-to-implant contact (BIC), bone volume/tissue volume (BV/TV)), and post implantation outcomes were assessed. Outcome data were analyzed using independent t-tests, Mann-Whitney U tests, Wilcoxon signed-rank tests, and one-way ANOVA (α = 0.05).
RESULTS:
No significant differences were noted between SLA and SF groups in terms of ISQ, marginal bone volume, BIC, and BV/TV (P > .05). However, significant differences in ISQ were observed within each group over time (P < .05). Furthermore, significant differences were noted in the marginal bone volume of the SF group (P < .05) and the BV/TV of the SLA group between weeks 4 and 6 (P < .05).
CONCLUSION
Surface treatment via SLA and femtosecond laser is feasible compared with SLA treatment alone in terms of ISQ, marginal bone volume, BIC, and BV/TV. However, further clinical research is warranted.
8.Comparison of interference from eccentric movements of dental crowns fabricated via dynamic jaw motion tracking and conventional methods: a double-blind clinical study
Myung Hyun PARK ; Keunbada SON ; Myoung-Uk JIN ; So-Yeun KIM ; Kyu-Bok LEE
The Journal of Advanced Prosthodontics 2025;17(1):36-46
PURPOSE:
The purpose of this clinical study was to evaluate the extent of intraoral occlusal adjustment required for zirconia crowns designed with a dynamic jaw motion tracking method compared to a conventional approach.
MATERIALS AND METHODS:
Fifteen patients needing zirconia crown restorations in the anterior or posterior regions participated in this study. Following tooth preparation, dynamic jaw motion tracking records were gathered using a tracking device. These records were imported into computer-aided design software and aligned with scanned upper and lower jaw data to design each crown's occlusal surface. Two crowns were fabricated for each patient: one using motion tracking data and another without it. Crowns were scanned pre- and post-adjustment following standard protocols. The scanned data were analyzed with 3D inspection software to calculate occlusal adjustments in the segmented occlusal area as root mean square values, with a paired t-test used for statistical analysis (α = 0.05).
RESULTS:
Crowns designed with motion tracking data required significantly less intraoral occlusal adjustment than those designed conventionally (P = .028).
CONCLUSION
Dynamic jaw motion tracking in crown design reduces the extent of intraoral occlusal adjustment, potentially enhancing clinical efficiency.
9.Comparison of intraoperative neurophysiological monitoring between propofol and remimazolam during total intravenous anesthesia in the cervical spine surgery: a prospective, double-blind, randomized controlled trial
Myoung Hwa KIM ; Jinyoung PARK ; Yoon Ghil PARK ; Yong Eun CHO ; Dawoon KIM ; Dong Jun LEE ; Kyu Wan KWAK ; Jongyun LEE ; Dong Woo HAN
Korean Journal of Anesthesiology 2025;78(1):16-29
Background:
Although total intravenous anesthesia (TIVA) with propofol and remifentanil is frequently used to optimize intraoperative neurophysiological monitoring (IONM), the exact effect of remimazolam on IONM remains unknown. Here, we compared the effects of propofol and remimazolam along with remifentanil on IONM during TIVA.
Methods:
In this prospective, double-blind, randomized controlled trial, 64 patients requiring IONM during cervical spine surgery were administered either propofol (Group P) or remimazolam (Group R). The preoperative latencies of the somatosensory-evoked potentials (SEP; N20 for the median nerve and P37 for the tibial nerve) were measured. SEP latencies and amplitudes and motor-evoked potential (MEP) amplitudes were measured 30 min after anesthetic induction (T1), 30 min after surgical incision (T2), after laminectomy or discectomy (T3), immediately after plate insertion or pedicle screw fixation (T4), and before surgical wound closure (T5). The primary outcome was the between-group difference in the N20 latency changes measured at T1 and preoperatively.
Results:
The change in SEP latencies including N20 and P37 at T1 compared with preoperative time was not significantly different between Groups P and R. Except for the amplitude of the right abductor brevis, there was no significant group-by-time interaction effect for intraoperative MEP amplitudes or SEP latencies and amplitudes.
Conclusions
TIVA with remimazolam and remifentanil for cervical spine surgery yielded stable IONM, comparable to those observed with conventional TIVA with propofol and remifentanil. Further clinical trials are needed in other surgical contexts and with more diverse patient populations to determine the effects of remimazolam on IONM.
10.Effects of dental implant surface treated with sandblasting large grit acid-etching and femtosecond laser on implant stability, marginal bone volume, and histological results in a rabbit model
Young-Tak SON ; KeunBaDa SON ; Hoseong CHO ; Jae-Mok LEE ; Sm Abu SALEAH ; JunHo HWANG ; JongHoon LEE ; HyunDeok KIM ; Myoung-Uk JIN ; Jeehyun KIM ; Mansik JEON ; Kyu-Bok LEE
The Journal of Advanced Prosthodontics 2025;17(2):101-114
PURPOSE:
The purpose of this study was to compare the surface characteristics and healing patterns after implantation of implants treated with SLA and those treated with both SLA and femtosecond laser.
MATERIALS AND METHODS:
A total of 10 male New Zealand white rabbits were used to compare recovery levels between implants treated with SLA (SLA group) and those treated with both SLA and femtosecond laser (SF group). The implants’ surface characteristics were determined through topographic evaluation, element analysis, surface roughness, and wettability evaluation. In total, 4 implants were placed in each rabbit (2 in each tibia), with 20 implants per treatment group. Using the implant stability quotient (ISQ), marginal bone volume, and histological analysis (bone-to-implant contact (BIC), bone volume/tissue volume (BV/TV)), and post implantation outcomes were assessed. Outcome data were analyzed using independent t-tests, Mann-Whitney U tests, Wilcoxon signed-rank tests, and one-way ANOVA (α = 0.05).
RESULTS:
No significant differences were noted between SLA and SF groups in terms of ISQ, marginal bone volume, BIC, and BV/TV (P > .05). However, significant differences in ISQ were observed within each group over time (P < .05). Furthermore, significant differences were noted in the marginal bone volume of the SF group (P < .05) and the BV/TV of the SLA group between weeks 4 and 6 (P < .05).
CONCLUSION
Surface treatment via SLA and femtosecond laser is feasible compared with SLA treatment alone in terms of ISQ, marginal bone volume, BIC, and BV/TV. However, further clinical research is warranted.

Result Analysis
Print
Save
E-mail