1.Effects of dental implant surface treated with sandblasting large grit acid-etching and femtosecond laser on implant stability, marginal bone volume, and histological results in a rabbit model
Young-Tak SON ; KeunBaDa SON ; Hoseong CHO ; Jae-Mok LEE ; Sm Abu SALEAH ; JunHo HWANG ; JongHoon LEE ; HyunDeok KIM ; Myoung-Uk JIN ; Jeehyun KIM ; Mansik JEON ; Kyu-Bok LEE
The Journal of Advanced Prosthodontics 2025;17(2):101-114
PURPOSE:
The purpose of this study was to compare the surface characteristics and healing patterns after implantation of implants treated with SLA and those treated with both SLA and femtosecond laser.
MATERIALS AND METHODS:
A total of 10 male New Zealand white rabbits were used to compare recovery levels between implants treated with SLA (SLA group) and those treated with both SLA and femtosecond laser (SF group). The implants’ surface characteristics were determined through topographic evaluation, element analysis, surface roughness, and wettability evaluation. In total, 4 implants were placed in each rabbit (2 in each tibia), with 20 implants per treatment group. Using the implant stability quotient (ISQ), marginal bone volume, and histological analysis (bone-to-implant contact (BIC), bone volume/tissue volume (BV/TV)), and post implantation outcomes were assessed. Outcome data were analyzed using independent t-tests, Mann-Whitney U tests, Wilcoxon signed-rank tests, and one-way ANOVA (α = 0.05).
RESULTS:
No significant differences were noted between SLA and SF groups in terms of ISQ, marginal bone volume, BIC, and BV/TV (P > .05). However, significant differences in ISQ were observed within each group over time (P < .05). Furthermore, significant differences were noted in the marginal bone volume of the SF group (P < .05) and the BV/TV of the SLA group between weeks 4 and 6 (P < .05).
CONCLUSION
Surface treatment via SLA and femtosecond laser is feasible compared with SLA treatment alone in terms of ISQ, marginal bone volume, BIC, and BV/TV. However, further clinical research is warranted.
2.Comparison of interference from eccentric movements of dental crowns fabricated via dynamic jaw motion tracking and conventional methods: a double-blind clinical study
Myung Hyun PARK ; Keunbada SON ; Myoung-Uk JIN ; So-Yeun KIM ; Kyu-Bok LEE
The Journal of Advanced Prosthodontics 2025;17(1):36-46
PURPOSE:
The purpose of this clinical study was to evaluate the extent of intraoral occlusal adjustment required for zirconia crowns designed with a dynamic jaw motion tracking method compared to a conventional approach.
MATERIALS AND METHODS:
Fifteen patients needing zirconia crown restorations in the anterior or posterior regions participated in this study. Following tooth preparation, dynamic jaw motion tracking records were gathered using a tracking device. These records were imported into computer-aided design software and aligned with scanned upper and lower jaw data to design each crown's occlusal surface. Two crowns were fabricated for each patient: one using motion tracking data and another without it. Crowns were scanned pre- and post-adjustment following standard protocols. The scanned data were analyzed with 3D inspection software to calculate occlusal adjustments in the segmented occlusal area as root mean square values, with a paired t-test used for statistical analysis (α = 0.05).
RESULTS:
Crowns designed with motion tracking data required significantly less intraoral occlusal adjustment than those designed conventionally (P = .028).
CONCLUSION
Dynamic jaw motion tracking in crown design reduces the extent of intraoral occlusal adjustment, potentially enhancing clinical efficiency.
3.Effects of dental implant surface treated with sandblasting large grit acid-etching and femtosecond laser on implant stability, marginal bone volume, and histological results in a rabbit model
Young-Tak SON ; KeunBaDa SON ; Hoseong CHO ; Jae-Mok LEE ; Sm Abu SALEAH ; JunHo HWANG ; JongHoon LEE ; HyunDeok KIM ; Myoung-Uk JIN ; Jeehyun KIM ; Mansik JEON ; Kyu-Bok LEE
The Journal of Advanced Prosthodontics 2025;17(2):101-114
PURPOSE:
The purpose of this study was to compare the surface characteristics and healing patterns after implantation of implants treated with SLA and those treated with both SLA and femtosecond laser.
MATERIALS AND METHODS:
A total of 10 male New Zealand white rabbits were used to compare recovery levels between implants treated with SLA (SLA group) and those treated with both SLA and femtosecond laser (SF group). The implants’ surface characteristics were determined through topographic evaluation, element analysis, surface roughness, and wettability evaluation. In total, 4 implants were placed in each rabbit (2 in each tibia), with 20 implants per treatment group. Using the implant stability quotient (ISQ), marginal bone volume, and histological analysis (bone-to-implant contact (BIC), bone volume/tissue volume (BV/TV)), and post implantation outcomes were assessed. Outcome data were analyzed using independent t-tests, Mann-Whitney U tests, Wilcoxon signed-rank tests, and one-way ANOVA (α = 0.05).
RESULTS:
No significant differences were noted between SLA and SF groups in terms of ISQ, marginal bone volume, BIC, and BV/TV (P > .05). However, significant differences in ISQ were observed within each group over time (P < .05). Furthermore, significant differences were noted in the marginal bone volume of the SF group (P < .05) and the BV/TV of the SLA group between weeks 4 and 6 (P < .05).
CONCLUSION
Surface treatment via SLA and femtosecond laser is feasible compared with SLA treatment alone in terms of ISQ, marginal bone volume, BIC, and BV/TV. However, further clinical research is warranted.
4.Comparison of interference from eccentric movements of dental crowns fabricated via dynamic jaw motion tracking and conventional methods: a double-blind clinical study
Myung Hyun PARK ; Keunbada SON ; Myoung-Uk JIN ; So-Yeun KIM ; Kyu-Bok LEE
The Journal of Advanced Prosthodontics 2025;17(1):36-46
PURPOSE:
The purpose of this clinical study was to evaluate the extent of intraoral occlusal adjustment required for zirconia crowns designed with a dynamic jaw motion tracking method compared to a conventional approach.
MATERIALS AND METHODS:
Fifteen patients needing zirconia crown restorations in the anterior or posterior regions participated in this study. Following tooth preparation, dynamic jaw motion tracking records were gathered using a tracking device. These records were imported into computer-aided design software and aligned with scanned upper and lower jaw data to design each crown's occlusal surface. Two crowns were fabricated for each patient: one using motion tracking data and another without it. Crowns were scanned pre- and post-adjustment following standard protocols. The scanned data were analyzed with 3D inspection software to calculate occlusal adjustments in the segmented occlusal area as root mean square values, with a paired t-test used for statistical analysis (α = 0.05).
RESULTS:
Crowns designed with motion tracking data required significantly less intraoral occlusal adjustment than those designed conventionally (P = .028).
CONCLUSION
Dynamic jaw motion tracking in crown design reduces the extent of intraoral occlusal adjustment, potentially enhancing clinical efficiency.
5.Effects of dental implant surface treated with sandblasting large grit acid-etching and femtosecond laser on implant stability, marginal bone volume, and histological results in a rabbit model
Young-Tak SON ; KeunBaDa SON ; Hoseong CHO ; Jae-Mok LEE ; Sm Abu SALEAH ; JunHo HWANG ; JongHoon LEE ; HyunDeok KIM ; Myoung-Uk JIN ; Jeehyun KIM ; Mansik JEON ; Kyu-Bok LEE
The Journal of Advanced Prosthodontics 2025;17(2):101-114
PURPOSE:
The purpose of this study was to compare the surface characteristics and healing patterns after implantation of implants treated with SLA and those treated with both SLA and femtosecond laser.
MATERIALS AND METHODS:
A total of 10 male New Zealand white rabbits were used to compare recovery levels between implants treated with SLA (SLA group) and those treated with both SLA and femtosecond laser (SF group). The implants’ surface characteristics were determined through topographic evaluation, element analysis, surface roughness, and wettability evaluation. In total, 4 implants were placed in each rabbit (2 in each tibia), with 20 implants per treatment group. Using the implant stability quotient (ISQ), marginal bone volume, and histological analysis (bone-to-implant contact (BIC), bone volume/tissue volume (BV/TV)), and post implantation outcomes were assessed. Outcome data were analyzed using independent t-tests, Mann-Whitney U tests, Wilcoxon signed-rank tests, and one-way ANOVA (α = 0.05).
RESULTS:
No significant differences were noted between SLA and SF groups in terms of ISQ, marginal bone volume, BIC, and BV/TV (P > .05). However, significant differences in ISQ were observed within each group over time (P < .05). Furthermore, significant differences were noted in the marginal bone volume of the SF group (P < .05) and the BV/TV of the SLA group between weeks 4 and 6 (P < .05).
CONCLUSION
Surface treatment via SLA and femtosecond laser is feasible compared with SLA treatment alone in terms of ISQ, marginal bone volume, BIC, and BV/TV. However, further clinical research is warranted.
6.Comparison of interference from eccentric movements of dental crowns fabricated via dynamic jaw motion tracking and conventional methods: a double-blind clinical study
Myung Hyun PARK ; Keunbada SON ; Myoung-Uk JIN ; So-Yeun KIM ; Kyu-Bok LEE
The Journal of Advanced Prosthodontics 2025;17(1):36-46
PURPOSE:
The purpose of this clinical study was to evaluate the extent of intraoral occlusal adjustment required for zirconia crowns designed with a dynamic jaw motion tracking method compared to a conventional approach.
MATERIALS AND METHODS:
Fifteen patients needing zirconia crown restorations in the anterior or posterior regions participated in this study. Following tooth preparation, dynamic jaw motion tracking records were gathered using a tracking device. These records were imported into computer-aided design software and aligned with scanned upper and lower jaw data to design each crown's occlusal surface. Two crowns were fabricated for each patient: one using motion tracking data and another without it. Crowns were scanned pre- and post-adjustment following standard protocols. The scanned data were analyzed with 3D inspection software to calculate occlusal adjustments in the segmented occlusal area as root mean square values, with a paired t-test used for statistical analysis (α = 0.05).
RESULTS:
Crowns designed with motion tracking data required significantly less intraoral occlusal adjustment than those designed conventionally (P = .028).
CONCLUSION
Dynamic jaw motion tracking in crown design reduces the extent of intraoral occlusal adjustment, potentially enhancing clinical efficiency.
7.Thoracic spinal cord damage in rat following cardiac arrest: neuronal loss, blood-spinal cord barrier leakage, and astrocyte endfeet disruption
Myoung Cheol SHIN ; Hyun-Jin TAE ; Joon Ha PARK ; Ji Hyeon AHN ; Dae Won KIM ; Moo-Ho WON ; Jun Hwi CHO ; Tae-Kyeong LEE
Journal of the Korean Society of Emergency Medicine 2025;36(1):1-11
Objective:
Cardiac arrest and cardiopulmonary resuscitation (CA/R) lead to whole-body ischemia and reperfusion (IR) injury, causing multiple organ dysfunction, including ischemic spinal cord injury. The thoracic spinal cord levels are crucial for maintaining the sympathetic functions vital for life. This study examined blood-spinal cord barrier (BSCB) leakage and astrocyte endfeet (AEF) disruption and their effects on survival, physiological variables, and neuronal damage/death in the intermediate zone (IMZ) at the seventh thoracic spinal cord level after asphyxial CA/R in rats.
Methods:
The rats underwent whole-body IR injury by asphyxial CA/R. Kaplan-Meier analysis was conducted to assess the cumulative survival post-CA/R. The histological changes post-CA/R were evaluated using immunohistochemistry, histofluorescence, and double histofluorescence.
Results:
No significant differences in body weight, mean arterial pressure, and heart rate were found between the sham and CA/R groups post-CA/R. The survival rates in the CA/R group at 12, 24, and 48 hours were 62.58%, 36.37%, and 7.8%, respectively. Neuronal loss and BSCB leakage began 12 hours post-CA/R, increasing with time. Reactive astrogliosis appeared at 12 hours and increased, while AEF disruption around blood vessels was evident at 48 hours.
Conclusion
The survival rate declined significantly by 48 hours post-CA/R. Neuronal loss and BSCB leakage in the thoracic spinal cord IMZ was evident at 12 hours and significant by 48 hours, aligning with AEF disruption. Neuronal loss in the thoracic spinal cord IMZ post-CA/R may be related to BSCB leakage and AEF disruption.
8.Prognostic Value of Ambulatory Status at Transplant in Older Heart Transplant Recipients: Implications for Organ Allocation Policy
Junho HYUN ; Jong-Chan YOUN ; Jung Ae HONG ; Darae KIM ; Jae-Joong KIM ; Myoung Soo KIM ; Jaewon OH ; Jin-Jin KIM ; Mi-Hyang JUNG ; In-Cheol KIM ; Sang-Eun LEE ; Jin Joo PARK ; Min-Seok KIM ; Sung-Ho JUNG ; Hyun-Jai CHO ; Hae-Young LEE ; Seok-Min KANG ; Dong-Ju CHOI ; Jon A. KOBASHIGAWA ; Josef STEHLIK ; Jin-Oh CHOI
Journal of Korean Medical Science 2025;40(3):e14-
Background:
Shortage of organ donors in the Republic of Korea has become a major problem. To address this, it has been questioned whether heart transplant (HTx) allocation should be modified to reduce priority of older patients. We aimed to evaluate post-HTx outcomes according to recipient age and specific pre-HTx conditions using a nationwide prospective cohort.
Methods:
We analyzed clinical characteristics of 628 patients from the Korean Organ Transplant Registry who received HTx from January 2015 to December 2020. Enrolled recipients were divided into three groups according to age. We also included comorbidities including ambulatory status. Non-ambulatory status was defined as pre-HTx support with either extracorporeal membrane oxygenation, continuous renal replacement therapy, or mechanical ventilation.
Results:
Of the 628 patients, 195 were < 50 years, 322 were 50–64 years and 111 were ≥ 65years at transplant. Four hundred nine (65.1%) were ambulatory and 219 (34.9%) were nonambulatory. Older recipients tended to have more comorbidities, ischemic cardiomyopathy, and received older donors. Post-HTx survival was significantly lower in older recipients (P = 0.025) and recipients with non-ambulatory status (P < 0.001). However, in contrast to non-ambulatory recipients who showed significant survival differences according to the recipient’s age (P = 0.004), ambulatory recipients showed comparable outcomes (P = 0.465).
Conclusion
Our results do not support use of age alone as an allocation criterion. Transplant candidate age in combination with some comorbidities such as non-ambulatory status may identify patients at a sufficiently elevated risk at which suitability of HTx should be reconsidered.
9.Prognostic Value of Ambulatory Status at Transplant in Older Heart Transplant Recipients: Implications for Organ Allocation Policy
Junho HYUN ; Jong-Chan YOUN ; Jung Ae HONG ; Darae KIM ; Jae-Joong KIM ; Myoung Soo KIM ; Jaewon OH ; Jin-Jin KIM ; Mi-Hyang JUNG ; In-Cheol KIM ; Sang-Eun LEE ; Jin Joo PARK ; Min-Seok KIM ; Sung-Ho JUNG ; Hyun-Jai CHO ; Hae-Young LEE ; Seok-Min KANG ; Dong-Ju CHOI ; Jon A. KOBASHIGAWA ; Josef STEHLIK ; Jin-Oh CHOI
Journal of Korean Medical Science 2025;40(3):e14-
Background:
Shortage of organ donors in the Republic of Korea has become a major problem. To address this, it has been questioned whether heart transplant (HTx) allocation should be modified to reduce priority of older patients. We aimed to evaluate post-HTx outcomes according to recipient age and specific pre-HTx conditions using a nationwide prospective cohort.
Methods:
We analyzed clinical characteristics of 628 patients from the Korean Organ Transplant Registry who received HTx from January 2015 to December 2020. Enrolled recipients were divided into three groups according to age. We also included comorbidities including ambulatory status. Non-ambulatory status was defined as pre-HTx support with either extracorporeal membrane oxygenation, continuous renal replacement therapy, or mechanical ventilation.
Results:
Of the 628 patients, 195 were < 50 years, 322 were 50–64 years and 111 were ≥ 65years at transplant. Four hundred nine (65.1%) were ambulatory and 219 (34.9%) were nonambulatory. Older recipients tended to have more comorbidities, ischemic cardiomyopathy, and received older donors. Post-HTx survival was significantly lower in older recipients (P = 0.025) and recipients with non-ambulatory status (P < 0.001). However, in contrast to non-ambulatory recipients who showed significant survival differences according to the recipient’s age (P = 0.004), ambulatory recipients showed comparable outcomes (P = 0.465).
Conclusion
Our results do not support use of age alone as an allocation criterion. Transplant candidate age in combination with some comorbidities such as non-ambulatory status may identify patients at a sufficiently elevated risk at which suitability of HTx should be reconsidered.
10.Evaluating Rituximab Failure Rates in Neuromyelitis Optica Spectrum Disorder: A Nationwide Real-World Study From South Korea
Su-Hyun KIM ; Ju-Hong MIN ; Sung-Min KIM ; Eun-Jae LEE ; Young-Min LIM ; Ha Young SHIN ; Young Nam KWON ; Eunhee SOHN ; Sooyoung KIM ; Min Su PARK ; Tai-Seung NAM ; Byeol-A YOON ; Jong Kuk KIM ; Kyong Jin SHIN ; Yoo Hwan KIM ; Jin Myoung SEOK ; Jeong Bin BONG ; Sohyeon KIM ; Hung Youl SEOK ; Sun-Young OH ; Ohyun KWON ; Sunyoung KIM ; Sukyoon LEE ; Nam-Hee KIM ; Eun Bin CHO ; Sa-Yoon KANG ; Seong-il OH ; Jong Seok BAE ; Suk-Won AHN ; Ki Hoon KIM ; You-Ri KANG ; Woohee JU ; Seung Ho CHOO ; Yeon Hak CHUNG ; Jae-Won HYUN ; Ho Jin KIM
Journal of Clinical Neurology 2025;21(2):131-136
Background:
and Purpose Treatments for neuromyelitis optica spectrum disorder (NMOSD) such as eculizumab, ravulizumab, satralizumab, and inebilizumab have significantly advanced relapse prevention, but they remain expensive. Rituximab is an off-label yet popular alternative that offers a cost-effective solution, but its real-world efficacy needs better quantification for guiding the application of newer approved NMOSD treatments (ANTs). This study aimed to determine real-world rituximab failure rates to anticipate the demand for ANTs and aid in resource allocation.
Methods:
We conducted a nationwide retrospective study involving 605 aquaporin-4-antibody-positive NMOSD patients from 22 centers in South Korea that assessed the efficacy and safety of rituximab over a median follow-up of 47 months.
Results:
The 605 patients treated with rituximab included 525 (87%) who received continuous therapy throughout the follow-up period (median=47 months, interquartile range=15–87 months). During this period, 117 patients (19%) experienced at least 1 relapse. Notably, 68 of these patients (11% of the total cohort) experienced multiple relapses or at least 1 severe relapse.Additionally, 2% of the patients discontinued rituximab due to adverse events, which included severe infusion reactions, neutropenia, and infections.
Conclusions
This study has confirmed the efficacy of rituximab in treating NMOSD, as evidenced by an 87% continuation rate among patients over a 4-year follow-up period. Nevertheless, the occurrence of at least one relapse in 19% of the cohort, including 11% who experienced multiple or severe relapses, and a 2% discontinuation rate due to adverse events highlight the urgent need for alternative therapeutic options.

Result Analysis
Print
Save