1.A Study on Verification of Equivalence and Effectiveness of Non-Pharmacologic Dementia Prevention and Early Detection Contents : Non-Randomly Equivalent Design
Hyun-Seok JEONG ; Oh-Lyong KIM ; Bon-Hoon KOO ; Ki-Hyun KIM ; Gi-Hwan KIM ; Dai-Seg BAI ; Ji-Yean KIM ; Mun-Seon CHANG ; Hye-Geum KIM
Journal of Korean Neurosurgical Society 2022;65(2):315-324
Objective:
: The aim of this study was to verify the equivalence and effectiveness of the tablet-administered Korean Repeatable Battery for the Assessment of Neuropsychological Status (K-RBANS) for the prevention and early detection of dementia.
Methods:
: Data from 88 psychiatry and neurology patient samples were examined to evaluate the equivalence between tablet and paper administrations of the K-RBANS using a non-randomly equivalent group design. We calculated the prediction scores of the tablet-administered K-RBANS based on demographics and covariate-test scores for focal tests using norm samples and tested format effects. In addition, we compared the receiver operating characteristic curves to confirm the effectiveness of the K-RBANS for preventing and detecting dementia.
Results:
: In the analysis of raw scores, line orientation showed a significant difference (t=-2.94, p<0.001), and subtests showed small to large effect sizes (0.04–0.86) between paper- and tablet-administered K-RBANS. To investigate the format effect, we compared the predicted scaled scores of the tablet sample to the scaled scores of the norm sample. Consequently, a small effect size (d≤0.20) was observed in most of the subtests, except word list and story recall, which showed a medium effect size (d=0.21), while picture naming and subtests of delayed memory showed significant differences in the one-sample t-test. In addition, the area under the curve of the total scale index (TSI) (0.827; 95% confidence interval, 0.738–0.916) was higher than that of the five indices, ranging from 0.688 to 0.820. The sensitivity and specificity of TSI were 80% and 76%, respectively.
Conclusion
: The overall results of this study suggest that the tablet-administered K-RBANS showed significant equivalence to the norm sample, although some subtests showed format effects, and it may be used as a valid tool for the brief screening of patients with neuropsychological disorders in Korea.
2.The Korean Repeatable Battery for the Assessment of Neuropsychological Status-Update : Psychiatric and Neurosurgery Patient Sample Validity
Jong-Ok PARK ; Bon-Hoon KOO ; Ji-Yean KIM ; Dai-Seg BAI ; Mun-Seon CHANG ; Oh-Lyong KIM
Journal of Korean Neurosurgical Society 2021;64(1):125-135
Objective:
: This study aimed to validate the Korean version of the Repeatable Battery for the Assessment of Neuropsychological Status Update (K-RBANS).
Methods:
: We performed a retrospective analysis of 283 psychiatric and neurosurgery patients. To investigate the convergent validity of the K-RBANS, correlation analyses were performed for other intelligence and neuropsychological test results. Confirmatory factor analysis was used to test a series of alternative plausible models of the K-RBANS. To analyze the various capabilities of the K-RBANS, we compared the area under the receiver operating characteristic (ROC) curves (AUC).
Results:
: Significant correlations were observed, confirming the convergent validity of the K-RBANS among the Total Scale Index (TSI) and indices of the K-RBANS and indices of intelligence (r=0.47–0.81; p<0.001) and other neuropsychological tests at moderate and above significance (r=0.41–0.63; p<0.001). Additionally, the results testing the construct validity of the K-RBANS showed that the second-order factor structure model (model 2, similar to an original factor structure of RBANS), which includes a first-order factor comprising five index scores (immediate memory, visuospatial capacity, language, attention, delayed memory) and one higher-order factor (TSI), was statistically acceptable. The comparative fit index (CFI) (CFI, 0.949) values and the goodness of fit index (GFI) (GFI, 0.942) values higher than 0.90 indicated an excellent fit. The root mean squared error of approximation (RMSEA) (RMSEA, 0.082) was considered an acceptable fit. Additionally, the factor structure of model 2 was found to be better and more valid than the other model in χ2 values (Δχ2=7.69, p<0.05). In the ROC analysis, the AUCs of the TSI and five indices were 0.716–0.837, and the AUC of TSI (AUC, 0.837; 95% confidence interval, 0.760–0.896) was higher than the AUCs of the other indices. The sensitivity and specificity of TSI were 77.66% and 78.12%, respectively.
Conclusion
: The overall results of this study suggest that the K-RBANS may be used as a valid tool for the brief screening of neuropsychological patients in Korea.
3.Risk Factors for Adverse Events of Therapeutic Plasma Exchange Assessed in a Single Center Study
Cheon Gang PARK ; A Jin LEE ; Seon Ho MUN ; Sang Gyung KIM ; Chang Ho JEON ; Hun Suk SUH
Korean Journal of Blood Transfusion 2019;30(2):148-155
BACKGROUND: Therapeutic plasma exchange (TPE) is used to remove pathologic substances involved in various disease etiologies. The use of TPE is increasing steadily in a variety of disease. This study analyzed the incidence, type and severity of adverse events (AE) according to the initial TPE of each patient in a single center. The risk factors for AE of TPE were also elucidated. METHODS: The medical and laboratory records of patients, who received TPE from January 2014 to December 2018, were reviewed retrospectively. The signs or symptoms during and after TPE were analyzed. RESULTS: TPE sessions were performed on 95 patients. The mean age was 53.3 years and men comprised 63.2%. The most common indication for TPE was desensitization for ABO-incompatible liver transplantation (ABO-i LT) (N=56, 58.9%). A total of 27 patients (28.4%) experienced AE during the initial TPE. The types of AE were allergic reactions (N=14, 14.7%), anaphylactic reaction (N=3, 11.1%), hypotension (N=5, 5.3%), hypocalcemic reaction (N=4, 4.2%), and febrile nonhemolytic reaction (N=1, 1.1%). The severities of AE were evaluated as mild in eight procedures (8.4 %), moderate in seventeen (17.9 %), and severe in two (2.1 %). Multivariable logistic regression analysis showed that the desensitization for ABO-i LT (odds ratio (OR), 2.08; 95% CI, 1.03~4.22) and the amount of FFP (OR, 1.07; 95% CI, 1.01~1.09) were associated with a higher incidence of AE. CONCLUSION: TPE can be performed under careful patient monitoring to provide prompt intervention, particularly in patients with desensitization of ABO-i LT using FFP.
Anaphylaxis
;
Humans
;
Hypersensitivity
;
Hypotension
;
Incidence
;
Liver Transplantation
;
Logistic Models
;
Male
;
Monitoring, Physiologic
;
Plasma Exchange
;
Plasma
;
Retrospective Studies
;
Risk Factors
4.The First Case of Otitis in Korea Caused by Brevibacterium otitidis
Seon Ho MUN ; A Jin LEE ; Sang Gyung KIM ; Chang Ho JEON ; Cheon Gang PARK ; Hun Suk SUH
Laboratory Medicine Online 2019;9(3):181-184
Brevibacterium spp. are gram-positive rods that are considered to be strictly nonpathogenic, and a very few cases of their infection in humans have been reported. In this study, we report a case of otitis caused by Brevibacterium otitidis. A 53-year-old woman, who visited the hospital, complained of symptoms, such as otorrhea from both ears, ear fullness, tinnitus, and hearing impairment, for several months. Ear discharge was cultured on blood agar for pathogen identification. Bacteria from the isolated colony were initially identified as Actinomyces odontolyticus by VITEK 2 (bioMerieux, France), whereas VITEK® MS (bioMerieux, France) identified them as Brevibacterium luteolum. Subsequently, bacteria from the isolated colony were confirmed as B. otitidis by 16S rRNA sequencing. Antimicrobial susceptibility testing confirmed their sensitivity to vancomycin and linezolid and resistance to clindamycin and penicillin. To our knowledge, this is the first reported case of otitis caused by B. otitidis in Korea.
Actinomyces
;
Agar
;
Bacteria
;
Brevibacterium
;
Clindamycin
;
Ear
;
Female
;
Gram-Positive Rods
;
Hearing Loss
;
Humans
;
Korea
;
Linezolid
;
Middle Aged
;
Otitis
;
Penicillins
;
RNA, Ribosomal, 16S
;
Tinnitus
;
Vancomycin
5.Acute Monoblastic Leukemia with t(11;17)(q23;q21): Fusion of the KMT2A(MLL) and MLLT6(AF17) Genes
Cheon Gang PARK ; Seon Ho MUN ; A Jin LEE ; Chang Ho JEON ; Hun Suk SUH ; Sang Gyung KIM
Laboratory Medicine Online 2019;9(4):258-262
The KMT2A (formerly MLL) gene is associated with at least 10% of all cases of acute leukemia. More than 80 translocation partner genes of KMT2A have been discovered to date, six of which have been identified on the long arm of chromosome 17. Among these, the MLLT6 (formerly AF17) gene is located at 17q12 and fuses with the KMT2A gene in rare cases of acute leukemia. We report here a case of AML with a KMT2A/MLLT6 fusion that was confirmed using molecular genetic methods. According to a literature review, this is the first reported case of AML with a KMT2A/MLLT6 fusion in Korea.
Arm
;
Chromosomes, Human, Pair 17
;
Korea
;
Leukemia
;
Leukemia, Monocytic, Acute
;
Molecular Biology
6.Effect of epidural corticosteroid injection on magnetic resonance imaging findings.
Min Soo KIM ; Tae Yoon JEONG ; Yu Seon CHEONG ; Young Wook JEON ; So Young LIM ; Seong Sik KANG ; In Nam KIM ; Tsong Bin CHANG ; Hyun Ho SEONG ; Byeong Mun HWANG
The Korean Journal of Pain 2017;30(4):281-286
BACKGROUND: Magnetic resonance imaging (MRI) of the spine is the preferred diagnostic tool for pathologic conditions affecting the spine. However, in patients receiving epidural corticosteroid injection (ESI) for treatment of spinal diseases, there is a possibility of misreading of MR images because of air or fluid in the epidural space after the injection. Therefore, we defined the characteristics of abnormal changes in MRI findings following an ESI in patients with low back pain. METHODS: We reviewed the medical records of 133 patients who underwent MRI of the lumbar spine within 7 days after ESI between 2006 and 2015.All patients were administered an ESI using a 22-gauge Tuohy needle at the lumbar spine through the interlaminar approach. The epidural space was identified by the loss of resistance technique with air. RESULTS: The incidences of abnormal changes in MRI findings because of ESI were 54%, 31%, and 25% in patients who underwent MRI at approximately 24 h, and 2 and 3 days after ESI, respectively. Abnormal MRI findings included epidural air or fluid, needle tracks, and soft tissue changes. Epidural air, the most frequent abnormal finding (82%), was observed in 41% of patients who underwent MRI within 3 days after injection. Abnormal findings due to an ESI were not observed in MR images acquired 4 days after ESI or later. CONCLUSIONS: Pain physicians should consider the possibility of abnormal findings in MR images acquired after epidural injection using the interlaminar approach and the loss of resistance technique with air at the lumbar spine.
Artifacts
;
Epidural Space
;
Glucocorticoids
;
Humans
;
Incidence
;
Injections, Epidural
;
Low Back Pain
;
Magnetic Resonance Imaging*
;
Medical Records
;
Needles
;
Spinal Diseases
;
Spine
7.Neuropsychological Characteristics of Mild Cognitive Impairment in Parkinson Disease and Subcortical Vascular Mild Cognitive Impairment.
Ji Hye KIM ; Young Sun JIN ; Mun Seon CHANG ; So Young CHOI ; Oh Dae KWON
Journal of the Korean Neurological Association 2011;29(3):177-183
BACKGROUND: Patients with Parkinson's disease and mild cognitive impairment (PD-MCI) and patients with subcortical vascular mild cognitive impairment (svMCI) are known to have cognitive dysfunction. The aim of this study was to determine the cognitive characteristics that can be used to differentiate these two conditions. METHODS: Twenty-two PD-MCI and 22 svMCI patients seen in our neurodegenerative disease clinic, and 22 normal controls were recruited. These three groups were matched in terms of age, gender, and education level. Mild cognitive impairment was diagnosed according to the criteria of Petersen. svMCI should meet the criteria modified from those of Erkinjuntti. RESULTS: Analysis of covariance revealed that frontal executive dysfunction was prominent in both the PD-MCI and svMCI groups after adjusting for depression. The scores in word fluency and the Stroop test were lower in the svMCI group than in the PD-MCI group. Both groups exhibited decreased performance in verbal and visuospatial memory tests. The score in the verbal recognition test was lower in the PD-MCI group than in the svMCI group, which exhibited comparatively reduced visuospatial memory. The depression level was higher in the PD-MCI group than in the svMCI group, as assessed using the Geriatric Depression Scale. CONCLUSIONS: The impairment in frontal executive function was more severe in the svMCI group than in the PD-MCI group, which displayed severe impairment in verbal memory function. These differences in cognitive function may help to differentiate PD-MCI from svMCI, and to further the understanding of their pathophysiologies. PD-MCI patients also exhibited severe depressive mood, which raises the possibility of cognitive improvement through therapy.
Cognition
;
Dementia, Vascular
;
Depression
;
Executive Function
;
Humans
;
Memory
;
Mild Cognitive Impairment
;
Neurodegenerative Diseases
;
Parkinson Disease
;
Stroop Test
8.Usefulness of Verbal Fluency Performance as Follow-up Screening Tool in Patients With Mild to Moderate Alzheimer's Disease.
Ju Hui LEE ; Kyung Hun KANG ; Ho Wan KWAK ; Mun Seon CHANG ; Dai Seg BAI ; Sung Pa PARK ; Ho Won LEE
Journal of the Korean Neurological Association 2011;29(2):106-111
BACKGROUND: Impaired verbal fluency in Alzheimer's disease (AD) has been well documented. Furthermore, crosssectional studies suggest that semantic fluency is disproportionately impaired relative to phonemic fluency in AD. The aim of this study was to determine the ability of fluency measures as follow-up screening tool for mild to moderate AD. METHODS: Participants were recruited from AD patients in mild to moderate stages. We annually evaluated semantic (animal, supermarket) and phonemic (giyeok, siot, ieung) fluency and tested other extensive neuropsychological measures for two years. RESULTS: A total of 33 AD patients were included at baseline and 1-year follow-up, who were aged 70.18+/-5.97 years at baseline. Eleven patients completed a 2-year follow-up. Phonemic fluency total score was not significantly changed during the study period. However, semantic fluency total score tended to decline annually, and significantly declined at 2-year follow-up compared to baseline. In addition, difference score (semantic fluency minus phonemic fluency) was significantly decreased at every follow-up compared to previous year. In Pearson correlation analyses between changes of verbal fluency and other neuropsychological measures, changes of semantic fluency appeared to be significantly correlated with neuropsychological measures much more than changes of phonemic fluency. CONCLUSIONS: Significant longitudinal declines in semantic fluency compared to phonemic fluency seem to be consistent with previous cross-sectional studies. These patterns of changes in verbal fluency were observed even at an interval of one year follow-up in our study. The verbal fluency might be useful follow-up screening test for mild to moderate AD in the memory clinic setting.
Aged
;
Alzheimer Disease
;
Follow-Up Studies
;
Humans
;
Longitudinal Studies
;
Mass Screening
;
Memory
;
Semantics
9.The Relationship of Subclinical Hypothyroidism with Bone Mineral Density and Biochemical Bone Markers in Postmenopausal Women.
Chang O KIM ; Kye Seon PARK ; Kyung Chae PARK ; Kyung Kyun SHIN ; Moon Jong KIM ; Young Jin LEE
Journal of the Korean Academy of Family Medicine 2008;29(1):41-47
BACKGROUND: It is well recognized that thyroid hormone stimulates bone turnover, increasing bone resorption, thus affecting bone mineral density, but few data are available on untreated subclinical hypothyroidism. The aim of this study was to examine whether bone mineral density is increased in postmenopausal subclinical hypothyroidism patients compared with postmenopausal normal thyroid function women, and to evaluate the relationship between thyroid hormones (TSH, FT(4)) and bone mineral density or various biochemical markers of bone metabolism. METHODS: This was a cross sectional study of 132 postmenopausal women aged from 51 to 70 who undertook health screening program in Pundang CHA general hospital from 1996 to 2001. They were divided into two groups; subclinical hypothyroidism group (n=52) and normal thyroid function group (n=80) matched by age. RESULTS: The total bone mineral density was significantly increased in the subclinical hypothyroid group than in the normal group (P<0.05). The serum osteocalcin was lower in the subclinical hypothyroidism group (P<0.05), but neither the alkaline phosphatase nor the deoxypyridinoline showed any significance. For all participants in this study, TSH, but not FT(4), exhibited significant correlation with the total bone mineral density (r=0.188, P<0.05), and with the osteocalcin (r=-0.191, P<0.05). Multiple regression analysis identified the TSH as an independent predictor of the total bone mineral density (beta=0.0410; P< 0.05). CONCLUSION: This study indicated that subclinical hypothyroidism is one of the factors which can elevate bone mineral density in postmenopausal women.
Aged
;
Alkaline Phosphatase
;
Amino Acids
;
Biomarkers
;
Bone Density
;
Bone Resorption
;
Female
;
Hospitals, General
;
Humans
;
Hypothyroidism
;
Mass Screening
;
Osteocalcin
;
Thyroid Gland
;
Thyroid Hormones
10.Using a Microwave Oven to Disinfect Intermittent-Use Catheters.
Jeong Hwa CHOI ; Hye Ran CHOI ; Hyang Mi MUN ; Mi Rye SUH ; Hye Ryeon PARK ; Jae Bum JEON ; Seon Ok SONG ; Sang Ho CHOI ; Mi Suk LEE ; Nam Joong KIM ; Mi Na KIM ; Yang Soo KIM ; Jun Hee WOO ; Jiso RYU ; Mee Sou CHANG
Korean Journal of Nosocomial Infection Control 2005;10(2):65-72
BACKGROUND: Clean intermittent catheterization is one of the management of the neurogenic bladder caused by such disease as spinal injury. The purpose of this study is to assess the amount of time in a microwave oven required to eliminate seven pathogens isolated from urine of the patients, and to evaluate the effect of repeated use of a microwave oven on the patency and pliability of silicon catheter. METHODS: Seven microorganisms isolated from urine of patients were used as inoculating pathogens. These included Escherichia coli, Klebsiella pneumoniae, Pseudomonas aeruginosa, Enterococcus faecalis, Enterococcus faecium, Staphylococcus aureus, Candida albicans. The silicon catheter was divided into six pieces (4 cm) and sterilized by ethylene oxide gas, Each piece of catheter was incubated for 60 minutes in a suspension of microorganisms, and placed in a plastic container. The piece was microwaved for 0 (control catheters) to 15 minutes a dose of 1,000 watts. Two methods were used. First method was a water-free method that was microwaved after removing water from the catheter. Second method was a water-added method that was microwaved after adding 5 mL of sterile water around the catheter. Then, that was placed in 15 mL sterile phosphate buffer in a conical tube. The fluid was cultured. Using a new silicon catheter, the microwave procedure was repeated until the catheter was no longer patent or pliable. RESULTS: Using a water-free method, E, coli, C. albicans were eliminated at 5 minutes, P. aeruginosa was at 8 minutes, K. pneumoniae, E. faecalis was at 12 minutes, but S. aureus was remained until 15 minutes, Using a water-added method, all strains were eliminated at 8 minutes. The characteristics of the silicon catheter after repeated procedures were not changed in patency or pliability until 100 times. CONCLUSION: The disinfection of silicon catheters using a microwave oven after adding water around the catheter was able to sterilize the frequent pathogens including C. albicans within 8 minutes. It was clinically useful to sterilize repeatedly the catheter using microwave oven without distorting the characteristics of the silicon catheter.
Candida albicans
;
Catheters*
;
Disinfection
;
Enterococcus faecalis
;
Enterococcus faecium
;
Escherichia coli
;
Ethylene Oxide
;
Humans
;
Intermittent Urethral Catheterization
;
Klebsiella pneumoniae
;
Microwaves*
;
Plastics
;
Pliability
;
Pneumonia
;
Pseudomonas aeruginosa
;
Silicones
;
Spinal Injuries
;
Staphylococcus aureus
;
Sterilization
;
Urinary Bladder, Neurogenic
;
Water

Result Analysis
Print
Save
E-mail