1.Effect of Home Blood Pressure Telemonitoring Plus Additional Support on Blood Pressure Control: A Randomized Clinical Trial.
Wen Wen MENG ; Yong Yi BAI ; Li YAN ; Wei ZHENG ; Qiang ZENG ; Yan Song ZHENG ; Lin ZHA ; Hong Ying PI ; Xiao Yong SAI
Biomedical and Environmental Sciences 2023;36(6):517-526
OBJECTIVE:
Current clinical evidence on the effects of home blood pressure telemonitoring (HBPT) on improving blood pressure control comes entirely from developed countries. Thus, we performed this randomized controlled trial to evaluate whether HBPT plus support (patient education and clinician remote hypertension management) improves blood pressure control more than usual care (UC) in the Chinese population.
METHODS:
This single-center, randomized controlled study was conducted in Beijing, China. Patients aged 30-75 years were eligible for enrolment if they had blood pressure [systolic (SBP) ≥ 140 mmHg and/or diastolic (DBP) ≥ 90 mmHg; or SBP ≥ 130 mmHg and/or DBP ≥ 80 mmHg with diabetes]. We recruited 190 patients randomized to either the HBPT or the UC groups for 12 weeks. The primary endpoints were blood pressure reduction and the proportion of patients achieving the target blood pressure.
RESULTS:
Totally, 172 patients completed the study, the HBPT plus support group ( n = 84), and the UC group ( n = 88). Patients in the plus support group showed a greater reduction in mean ambulatory blood pressure than those in the UC group. The plus support group had a significantly higher proportion of patients who achieved the target blood pressure and maintained a dipper blood pressure pattern at the 12th week of follow-up. Additionally, the patients in the plus support group showed lower blood pressure variability and higher drug adherence than those in the UC group.
CONCLUSION
HBPT plus additional support results in greater blood pressure reduction, better blood pressure control, a higher proportion of dipper blood pressure patterns, lower blood pressure variability, and higher drug adherence than UC. The development of telemedicine may be the cornerstone of hypertension management in primary care.
Humans
;
Blood Pressure
;
Blood Pressure Monitoring, Ambulatory
;
Hypertension/therapy*
;
Telemedicine/methods*
;
Hypotension
2.Technical Difficulties in the Implementation of the Continuous Glucose Monitoring System.
Yacheng FU ; Changyun QUAN ; Lixia LIU ; Wei ZHANG
Chinese Journal of Medical Instrumentation 2022;46(4):422-427
The continuous glucose monitoring system (CGMS) has been clinically applied to monitor the dynamic change of the subcutaneous interstitial glucose concentration which is a function of the blood glucose level by glucose sensors. It can track blood glucose levels all day along, and thus provide comprehensive and reliable information about blood glucose dynamics. The clinical application of CGMS enables monitoring of blood glucose fluctuations and the discovery of hidden hyperglycemia and hypoglycemia that are difficult to be detected by traditional methods. As a CGMS needs to work subcutaneously for a long time, a series of factors such as biocompatibility, enzyme inactivation, oxygen deficiency, foreign body reaction, implant size, electrode flexibility, error correction, comfort, device toxicity, electrical safety, et al. should be considered beforehand. The study focused on the difficulties in the technology, and compared the products of Abbott, Medtronic and DexCom, then summarized their cutting-edge. Finally, this study expounded some key technologies in dynamic blood glucose monitoring and therefore can be utilized as a reference for the development of CGMS.
Blood Glucose
;
Blood Glucose Self-Monitoring/methods*
;
Humans
;
Hyperglycemia
;
Hypoglycemia
;
Monitoring, Ambulatory/methods*
;
Monitoring, Physiologic
3.Remote cardiac rehabilitation is a good alternative of outpatient cardiac rehabilitation in the COVID-19 era.
Atsuko NAKAYAMA ; Naoko TAKAYAMA ; Momoko KOBAYASHI ; Kanako HYODO ; Naomi MAESHIMA ; Fujiwara TAKAYUKI ; Hiroyuki MORITA ; Issei KOMURO
Environmental Health and Preventive Medicine 2020;25(1):48-48
BACKGROUND:
In the wake of the coronavirus disease 2019 (COVID-19) pandemic, people need to practice social distancing in order to protect themselves from SARS-CoV-2 infection. In such stressful situations, remote cardiac rehabilitation (CR) might be a viable alternative to the outpatient CR program.
METHODS:
We prospectively investigated patients hospitalized for heart failure (HF) with a left ventricular ejection fraction of < 50%. As for patients who participated in the remote CR program, telephone support was provided by cardiologists and nurses who specialized in HF every 2 weeks after discharge. The emergency readmission rate within 30 days of discharge was compared among the outpatient CR, remote CR, and non-CR groups, and the EQ-5D score was compared between the outpatient CR and remote CR groups.
RESULTS:
The participation rate of HF patients in our remote CR program elevated during the COVID-19 pandemic. As observed in the outpatient CR group (n = 69), the emergency readmission rate within 30 days of discharge was lower in the remote CR group (n = 30) than in the non-CR group (n = 137) (P = 0.02). The EQ-5D score was higher in the remote CR group than in the outpatient CR group (P = 0.03) 30 days after discharge.
CONCLUSIONS
Remote CR is as effective as outpatient CR for improving the short-term prognosis of patients hospitalized for heart failure post-discharge. This suggests that the remote CR program can be provided as a good alternative to the outpatient CR program.
Aged
;
Betacoronavirus
;
Cardiac Rehabilitation
;
methods
;
Coronavirus Infections
;
epidemiology
;
Heart Failure
;
rehabilitation
;
Humans
;
Japan
;
Middle Aged
;
Monitoring, Ambulatory
;
Pandemics
;
Pneumonia, Viral
;
epidemiology
;
Prospective Studies
;
Self Care
;
Telemedicine
;
methods
;
Telephone
4.Comparisons between different blood pressure measurement techniques in patients with chronic kidney disease
Shahrokh Ezzatzadegan JAHROMI ; Ghasem HAGHIGHI ; Jamshid ROOZBEH ; Vahid EBRAHIMI
Kidney Research and Clinical Practice 2019;38(2):212-219
BACKGROUND: Automated office blood pressure (AOBP) machines measure blood pressure (BP) multiple times over a brief period. We aimed to compare the results of manual office blood pressure (MOBP) and AOBP methods with ambulatory BP monitoring (ABPM) in patients with chronic kidney disease (CKD). METHODS: This study was performed on 64 patients with CKD (stages 3–4). A nurse manually measured the BP on both arms using a mercury sphygmomanometer, followed by AOBP of the arm with the higher BP and then ABPM. Mean BP readings were compared by paired t test and Bland–Altman graphs. RESULTS: The mean ± standard deviation (SD) age of participants was 59.3 ± 13.6. The mean ± SD awake systolic BP obtained by ABPM was 140.2 ± 19.0 mmHg, which was lower than the MOBP and AOBP methods (156.6 ± 17.8 and 148.8 ± 18.6 mmHg, respectively; P < 0.001). The mean ± SD awake diastolic BP was 78.6 ± 13.2 mmHg by ABPM which was lower than the MOBP and AOBP methods (88.9 ± 13.2 and 84.1 ± 14.0 mmHg, respectively; P < 0.001). Using Bland–Altman graphs, MOBP systolic BP readings showed a bias of 16.4 mmHg, while AOBP measurements indicated a bias of 8.6 mmHg compared with ABPM. CONCLUSION: AOBP methods may be more reliable than MOBP methods for determining BP in patients with CKD. However, the significantly higher mean BPs recorded by AOBP method suggested that AOBPs may not be as accurate as ABPM in patients with CKD.
Arm
;
Bias (Epidemiology)
;
Blood Pressure Monitoring, Ambulatory
;
Blood Pressure
;
Humans
;
Hypertension
;
Methods
;
Reading
;
Renal Insufficiency, Chronic
;
Sphygmomanometers
5.Prevalence of Masked Hypertension: a Population-Based Survey in a Large City by Using 24-Hour Ambulatory Blood Pressure Monitoring.
Moo Yong RHEE ; Sun Woong KIM ; Eun Hee CHOI ; Ji Hyun KIM ; Deuk Young NAH ; Sung Joon SHIN ; Namyi GU
Korean Circulation Journal 2016;46(5):681-687
BACKGROUND AND OBJECTIVES: We estimated the prevalence of hypertension and hypertension subtypes in a large semi-urban city in Korea, using 24-hour ambulatory blood pressure monitoring (ABPM) in a randomly selected sample population. SUBJECTS AND METHODS: A random sample (aged 20-65 years) from a city with an adult population of approximately 600000 was selected by using a list-assisted random digit dialing method. The 24-hour ABPM and conventional blood pressure measurement (CBPM) of these individuals were obtained. RESULTS: Among the 496 participants, valid 24-hour ABPM and CBPM were obtained from 462 (93%) individuals. The estimated prevalence of hypertension in Goyang was 17.54% by CBPM and 32.70% by 24-hour ABPM (p<0.01). In the age stratified analysis, both CBPM and 24-hour ABPM showed increased prevalence of hypertension with age. The estimated prevalence of masked hypertension was 16.22% and that of white-coat hypertension was 1.08%. Men had a higher prevalence of masked hypertension than women (20.79% vs. 11.86%, p=0.0295). The estimated prevalence of masked hypertension was 17.5%, 20.58%, 24.34%, and 13.29% in the age categories of 30s, 40s, 50s, and 60s, respectively. The estimated prevalence of masked uncontrolled hypertension was 26.79% in patients with hypertension who were taking antihypertensive medications. CONCLUSION: The estimated prevalence of hypertension by 24-hour ABPM was higher than that by CBPM, revealing high prevalence of masked hypertension. The high prevalence of masked hypertension supports the adoption of ABPM in the national population survey and clinical practice to improve public health and reduce health care costs.
Adult
;
Blood Pressure
;
Blood Pressure Monitoring, Ambulatory*
;
Female
;
Health Care Costs
;
Humans
;
Hypertension
;
Korea
;
Male
;
Masked Hypertension*
;
Masks*
;
Methods
;
Prevalence*
;
Public Health
6.Effect of angiotensin receptor blockade on central aortic systolic blood pressure in hypertensive Asians measured using radial tonometry: an open prospective cohort study.
Hui Hwang TEONG ; Adeline Mei Lin CHIN ; Ashish Anil SULE ; Jam Chin TAY
Singapore medical journal 2016;57(7):384-389
INTRODUCTIONCentral aortic systolic pressure (CASP) has been shown to be a stronger predictor of cardiovascular events than brachial blood pressure (BP). Different classes of drugs have differential effects on CASP and brachial BP. This open prospective cohort study aimed to observe changes in CASP (measured using radial tonometry) among hypertensive Asians after 12 weeks of treatment with valsartan, an angiotensin receptor blocker (ARB).
METHODSPatients with treatment-naïve hypertension or uncontrolled hypertension who were on non-ARB therapy were eligible for inclusion. Patients with uncontrolled BP (i.e. ≥ 140/90 mmHg) received valsartan for 12 weeks. The patients' brachial systolic and diastolic BP (SBP and DBP), and CASP changes were monitored using the BPro® watch.
RESULTSThe mean age of the 44 enrolled patients was 35 years. At baseline, the mean BP and CASP were 150.2/91.4 ± 10.6/9.4 mmHg and 136.3 ± 12.2 mmHg, respectively. Valsartan reduced SBP, DBP and CASP by 14.9 ± 10.7 mmHg, 10.9 ± 8.4 mmHg and 15.3 ± 10.9 mmHg, respectively (all p < 0.001). Every 1.0-mmHg reduction in brachial SBP resulted in a 0.8-mmHg reduction in CASP (p < 0.001). A CASP cut-off of 122.5 mmHg discriminated between controlled and uncontrolled BP (sensitivity 74%, specificity 88%).
CONCLUSIONUsing radial tonometry, we demonstrated good correlation between CASP and brachial SBP reductions after 12 weeks of treatment with valsartan in our study cohort. Correlation analysis between CASP and SBP reductions may be useful for demonstrating whether a drug is able to lower CASP beyond lowering SBP.
Adult ; Angiotensin Receptor Antagonists ; pharmacology ; Aorta ; drug effects ; Blood Pressure ; Blood Pressure Monitoring, Ambulatory ; Diastole ; Female ; Humans ; Hypertension ; drug therapy ; Male ; Manometry ; methods ; Middle Aged ; Prospective Studies ; Receptors, Angiotensin ; metabolism ; Systole ; drug effects ; Valsartan ; therapeutic use ; Young Adult
7.Time points for obtaining representative values of 24-hour blood pressure in chronic kidney disease.
Jiwon RYU ; Ran Hui CHA ; Dong Ki KIM ; Ju Hyun LEE ; Sun Ae YOON ; Dong Ryeol RYU ; Jieun OH ; Sejoong KIM ; Sang Youb HAN ; Eun Young LEE ; Yon Su KIM
The Korean Journal of Internal Medicine 2015;30(5):665-674
BACKGROUND/AIMS: Ambulatory blood pressure (BP) monitoring has been widely recommended for evaluating the status of BP, but is lacking in practicality. Determination of the specific time points for BP measurement that are representative of 24-hour mean BP could be useful and convenient in hypertensive patients with chronic kidney disease (CKD). METHODS: A total of 1,317 patients for whom 24-hour ambulatory BP monitoring was performed were enrolled in a multicenter study on hypertensive CKD. We analyzed the time points at which systolic blood pressure (SBP) values exhibited the smallest differences from 24-hour mean SBP (mSBP). We included office mSBP and analyzed the relationships between SBPs at the office and the time points with the smallest differences from 24-hour mSBP using several methods. RESULTS: The time points with the smallest differences from 24-hour mSBP were 7:00 AM, 2:00 PM, and 9:30 PM. In regression analysis, SBPs at 7:00 AM and 9:30 PM were better correlated with 24-hour mSBP than SBPs at 2:00 PM and the office. The proportions of patients with SBPs within 30% of 24-hour mSBP were higher at 7:00 AM and 9:30 PM. The best consistency between the uncontrolled hypertensive groups, defined as > or = 135 mmHg of 24-hour mSBP and higher values of SBPs corresponding to 135 mmHg of 24-hour mSBP, were observed at the 7:00 AM and 9:30 PM time points. CONCLUSIONS: The specific time points for SBPs that correlated well with 24-hour mSBP in hypertensive CKD patients were 7:00 AM and 9:30 PM.
Adult
;
Aged
;
*Blood Pressure
;
Blood Pressure Monitoring, Ambulatory/*methods
;
Circadian Rhythm
;
Cross-Sectional Studies
;
Female
;
Humans
;
Hypertension/*diagnosis/physiopathology
;
Male
;
Middle Aged
;
Office Visits
;
Predictive Value of Tests
;
Prospective Studies
;
Renal Insufficiency, Chronic/*diagnosis/physiopathology
;
Republic of Korea
;
Time Factors
;
Young Adult
8.An implantable micro-device using wireless power transmission for measuring aortic aneurysm sac pressure.
Xudong GUO ; Bin GE ; Wenxing WANG
Journal of Biomedical Engineering 2013;30(4):724-729
In order to detect endoleaks after endovascular aneurysm repair (EVAR), we developed an implantable micro-device based on wireless power transmission to measure aortic aneurysm sac pressure. The implantable micro-device is composed of a miniature wireless pressure sensor, an energy transmitting coil, a data recorder and a data processing platform. Power transmission without interconnecting wires is performed by a transmitting coil and a receiving coil. The coupling efficiency of wireless power transmission depends on the coupling coefficient between the transmitting coil and the receiving coil. With theoretical analysis and experimental study, we optimized the geometry of the receiving coil to increase the coupling coefficient. In order to keep efficiency balance and satisfy the maximizing conditions, we designed a closed loop power transmission circuit, including a receiving voltage feedback module based on wireless communication. The closed loop improved the stability and reliability of transmission energy. The prototype of the micro-device has been developed and the experiment has been performed. The experiments showed that the micro-device was feasible and valid. For normal operation, the distance between the transmitting coil and the receiving coil is smaller than 8cm. Besides, the distance between the micro-device and the data recorder is within 50cm.
Aortic Aneurysm, Abdominal
;
physiopathology
;
surgery
;
Blood Pressure Monitors
;
Equipment Design
;
Humans
;
Monitoring, Ambulatory
;
instrumentation
;
Postoperative Care
;
instrumentation
;
methods
;
Prostheses and Implants
;
Wireless Technology
;
instrumentation
9.Study on the method and system for falling detection based on the inclinometer.
Yong ZHU ; Yan ZHANG ; Jia SONG ; Tianshuang QIU
Journal of Biomedical Engineering 2013;30(1):95-99
A falling is a risky incident of safety and health of human. It may cause serious injuries, such as bone fracture, and even death. A falling detection method based on inclinometer is described. At first, we collect angle data recorded by a wearable inclinometer placed at subject's waist. The angular data are transmitted to PC through a wireless data transmission device. Then, the falling duration is divided into three phases: the state of fall, the impact phase, and the posture phase. We make threshold-based fall-detection decisions in every phase after feature extraction and analysis of the short-time angle data. Finally, a robust falling detection result is given by comprehensive considerations of the three phases decisions. The experiment results proved that the accuracy of our falling detection method was up to 97.23% without undetected falls.
Accidental Falls
;
prevention & control
;
Aged
;
Algorithms
;
Equipment Design
;
Female
;
Humans
;
Male
;
Monitoring, Ambulatory
;
instrumentation
;
methods
;
Posture
10.Study on real-time wearable monitoring system for human heat and cold stresses.
Yuhong SHEN ; Tianhao WANG ; Chenming LI
Journal of Biomedical Engineering 2013;30(1):80-94
In order to study the way of evaluating human performance under heat and cold stresses, we developed a wearable physiological monitoring system-intelligent belt system, capable of providing real-time, continuous and dynamic monitoring of multiple physiological parameters. The system has following features: multiuser communication, high integration, strong environment adaptability, dynamic features and real time physiological monitoring ability. The system uses sensing belts and elastic belts to acquire physiological parameters, uses WIFI to build wireless network monitoring for multiuser, and uses Delphi to develop data processing software capable of real-time viewing, storagng, processing, and alerting. With four different intensity-activity trials on six subjects and compared with standard laboratory human physiological acquisition instruments, the system was proved to be able to acquire accu-rate physiological parameters such as ECG, respiration, multi-point body temperatures, and body movement. The system worked steadily and reliably. This wearable real-time monitoring system for human heat and cold stresses can solve the problem facing our country that human heat stress and cold stress monitoring technology is insufficient, provide new methods and new ways for monitoring and evaluation of human heat and cold stresses under real task or stress environment, and provide technical platform for the study on human ergonomics.
Biosensing Techniques
;
methods
;
Cold Temperature
;
Hot Temperature
;
Humans
;
Monitoring, Ambulatory
;
instrumentation
;
Stress, Physiological
;
physiology

Result Analysis
Print
Save
E-mail