1.Comparative Analysis of Olfactory and Gustatory Function of Patients With COVID-19 Olfactory Dysfunction and Non-COVID-19 Postinfectious Olfactory Dysfunction
Taesik JUNG ; Bo Yoon CHOI ; Minho JANG ; Taehee KIM ; EunHye SEO ; Jin Kook KIM
Journal of Korean Medical Science 2023;38(43):e352-
Background:
Coronavirus disease 2019 (COVID-19) is known to have a high incidence of loss of smell and taste. However, studies in the early stages of the COVID-19 pandemic have evaluated these symptoms using subjective surveys and simple olfactory tests only. Hence, we compared the olfactory and gustatory characteristics of patient groups with COVID-19 olfactory dysfunction (C19OD) and non-COVID-19 postinfectious olfactory dysfunction (PIOD) using an objective olfactory test and evaluated the significance of olfactory training in both patient groups.
Methods:
We retrospectively analyzed the medical records of 14 patients with a decreased sense of smell after having positive COVID-19 polymerase chain reaction results, and 56 patients with PIOD with no history of confirmed COVID-19. Participants were evaluated using the Korean version of the Sniffin’ stick (KVSS) II, and chemical gustometry and olfactory training was assessed during their first visit. Olfactory training was then re-evaluated after an average of 8 (± 6) weeks.
Results:
The average age of participants in the C19OD group was lower than in those in the non-COVID-19 PIOD group. The proportion of men in the C19OD group was higher than in the non-COVID-19 PIOD group. At baseline assessment, the C19OD group had better olfactory and gustatory functions. After olfactory training, the non-COVID-19 PIOD patient group showed a significant increase in all KVSS II Total, T, D, and I scores, but there was a non-significant increase in all scores in the C19OD group.
Conclusion
The C19OD group had better olfactory and gustatory function than the nonCOVID-19 PIOD group at the initial assessment. After olfactory training, there was an increase in olfactory function test scores in both groups. Olfactory training may be helpful in C19OD, as in non-COVID-19 PIOD.
2.Protocol for a Korean Multicenter Prospective Cohort Study of Active Surveillance or Surgery (KoMPASS) in Papillary Thyroid Microcarcinoma
Min Ji JEON ; Yea Eun KANG ; Jae Hoon MOON ; Dong Jun LIM ; Chang Yoon LEE ; Yong Sang LEE ; Sun Wook KIM ; Min-Hee KIM ; Bo Hyun KIM ; Ho-Cheol KANG ; Minho SHONG ; Sun Wook CHO ; Won Bae KIM
Endocrinology and Metabolism 2022;37(1):181-182
3.Full-arch accuracy of five intraoral scanners:In vivo analysis of trueness and precision
Miran KWON ; Youngmok CHO ; Dong-Wook KIM ; MyungSu KIM ; Yoon-Ji KIM ; Minho CHANG
The Korean Journal of Orthodontics 2021;51(2):95-104
Objective:
To evaluate the trueness and precision of full-arch scans acquired using five intraoral scanners and investigate the factors associated with the dimensional accuracy of the intraoral scan data.
Methods:
Nine adult participants (mean age, 34.3 ± 8.3 years) were recruited. Four zirconium spheres (Ø 6 mm) were bonded to the canines and the molars. Following acquisition of reference scans using an industrial-grade scanner, five intraoral scanners, namely i500, CS3600, Trios 3, iTero, and CEREC Omnicam, were used to scan the arches. Linear distances between the four reference spheres were automatically calculated, and linear mixed model analysis was performed to compare the trueness and precision of the intraoral scan data among the different scanners.
Results:
The absolute mean trueness and precision values for all intraoral scanners were 76.6 ± 79.3 and 56.6 ± 52.4 µm, respectively. The type of scanner and the measured linear distances had significant effects on the accuracy of the intraoral scan data. With regard to trueness, errors in the intermolar dimension and the distance from the canine to the contralateral molar were greater with Omnicam than with the other scanners. With regard to precision, the error in the linear distance from the canine to the molar in the same quadrant was greater with Omnicam and CS3600 than with the other scanners.
Conclusions
The dimensional accuracy of intraoral scan data may differ significantly according to the type of scanner, with the amount of error in terms of trueness being clinically significant.
4.Protocol for a Korean Multicenter Prospective Cohort Study of Active Surveillance or Surgery (KoMPASS) in Papillary Thyroid Microcarcinoma
Min Ji JEON ; Yea Eun KANG ; Jae Hoon MOON ; Dong Jun LIM ; Chang Yoon LEE ; Yong Sang LEE ; Sun Wook KIM ; Min-Hee KIM ; Bo Hyun KIM ; Ho-Cheol KANG ; Minho SHONG ; Sun Wook CHO ; Won Bae KIM
Endocrinology and Metabolism 2021;36(2):359-364
Background:
A Korean Multicenter Prospective cohort study of Active Surveillance or Surgery (KoMPASS) for papillary thyroid microcarcinomas (PTMCs) has been initiated. The aim is to compare clinical outcomes between active surveillance (AS) and an immediate lobectomy for low-risk PTMCs. We here outline the detailed protocol for this study.
Methods:
Adult patients with a cytopathologically confirmed PTMC sized 6.0 to 10.0 mm by ultrasound (US) will be included. Patients will be excluded if they have a suspicious extra-thyroidal extension or metastasis of a PTMC or multiple thyroid nodules or other thyroid diseases which require a total thyroidectomy. Printed material describing the prognosis of PTMCs, and the pros and cons of each management option, will be provided to eligible patients to select their preferred intervention. For the AS group, thyroid US, thyroid function, and quality of life (QoL) parameters will be monitored every 6 months during the first year, and then annually thereafter. Disease progression will be defined as a ≥3 mm increase in maximal diameter of a PTMC, or the development of new thyroid cancers or metastases. If progression is detected, patients should undergo appropriate surgery. For the lobectomy group, a lobectomy with prophylactic central neck dissection will be done within 6 months. After initial surgery, thyroid US, thyroid function, serum thyroglobulin (Tg), anti-Tg antibody, and QoL parameters will be monitored every 6 months during the first year and annually thereafter. Disease progression will be defined in these cases as the development of new thyroid cancers or metastases.
Conclusion
KoMPASS findings will help to confirm the role of AS, and develop individualized management strategies, for low-risk PTMCs.
5.Full-arch accuracy of five intraoral scanners:In vivo analysis of trueness and precision
Miran KWON ; Youngmok CHO ; Dong-Wook KIM ; MyungSu KIM ; Yoon-Ji KIM ; Minho CHANG
The Korean Journal of Orthodontics 2021;51(2):95-104
Objective:
To evaluate the trueness and precision of full-arch scans acquired using five intraoral scanners and investigate the factors associated with the dimensional accuracy of the intraoral scan data.
Methods:
Nine adult participants (mean age, 34.3 ± 8.3 years) were recruited. Four zirconium spheres (Ø 6 mm) were bonded to the canines and the molars. Following acquisition of reference scans using an industrial-grade scanner, five intraoral scanners, namely i500, CS3600, Trios 3, iTero, and CEREC Omnicam, were used to scan the arches. Linear distances between the four reference spheres were automatically calculated, and linear mixed model analysis was performed to compare the trueness and precision of the intraoral scan data among the different scanners.
Results:
The absolute mean trueness and precision values for all intraoral scanners were 76.6 ± 79.3 and 56.6 ± 52.4 µm, respectively. The type of scanner and the measured linear distances had significant effects on the accuracy of the intraoral scan data. With regard to trueness, errors in the intermolar dimension and the distance from the canine to the contralateral molar were greater with Omnicam than with the other scanners. With regard to precision, the error in the linear distance from the canine to the molar in the same quadrant was greater with Omnicam and CS3600 than with the other scanners.
Conclusions
The dimensional accuracy of intraoral scan data may differ significantly according to the type of scanner, with the amount of error in terms of trueness being clinically significant.
6.Protocol for a Korean Multicenter Prospective Cohort Study of Active Surveillance or Surgery (KoMPASS) in Papillary Thyroid Microcarcinoma
Min Ji JEON ; Yea Eun KANG ; Jae Hoon MOON ; Dong Jun LIM ; Chang Yoon LEE ; Yong Sang LEE ; Sun Wook KIM ; Min-Hee KIM ; Bo Hyun KIM ; Ho-Cheol KANG ; Minho SHONG ; Sun Wook CHO ; Won Bae KIM
Endocrinology and Metabolism 2021;36(2):359-364
Background:
A Korean Multicenter Prospective cohort study of Active Surveillance or Surgery (KoMPASS) for papillary thyroid microcarcinomas (PTMCs) has been initiated. The aim is to compare clinical outcomes between active surveillance (AS) and an immediate lobectomy for low-risk PTMCs. We here outline the detailed protocol for this study.
Methods:
Adult patients with a cytopathologically confirmed PTMC sized 6.0 to 10.0 mm by ultrasound (US) will be included. Patients will be excluded if they have a suspicious extra-thyroidal extension or metastasis of a PTMC or multiple thyroid nodules or other thyroid diseases which require a total thyroidectomy. Printed material describing the prognosis of PTMCs, and the pros and cons of each management option, will be provided to eligible patients to select their preferred intervention. For the AS group, thyroid US, thyroid function, and quality of life (QoL) parameters will be monitored every 6 months during the first year, and then annually thereafter. Disease progression will be defined as a ≥3 mm increase in maximal diameter of a PTMC, or the development of new thyroid cancers or metastases. If progression is detected, patients should undergo appropriate surgery. For the lobectomy group, a lobectomy with prophylactic central neck dissection will be done within 6 months. After initial surgery, thyroid US, thyroid function, serum thyroglobulin (Tg), anti-Tg antibody, and QoL parameters will be monitored every 6 months during the first year and annually thereafter. Disease progression will be defined in these cases as the development of new thyroid cancers or metastases.
Conclusion
KoMPASS findings will help to confirm the role of AS, and develop individualized management strategies, for low-risk PTMCs.
7.The accuracy evaluation of digital surgical stents according to supported type
Junyoun LEE ; Minho YOON ; Taeseok PARK ; Inkon CHUN ; Kwidug YUN
The Journal of Korean Academy of Prosthodontics 2018;56(1):8-16
PURPOSE: The purpose of this study is to evaluate the accuracy of surgical stent according to the supported type. MATERIALS AND METHODS: 5 sets of dental models which have tooth supported edentulous area and tooth-tissue supported edentulous area were made. Dental model were scanned with model scanner, and CBCT was taken. CT data and model scan data were overlapped using In2Guide software, implant were virtually planned in the software. Surgical stents are fabricated by 3D printing. The implant fixture were installed using the surgical stent, CBCT were retaken. CBCT before surgery and after surgery were overlapped, and the differences (angle difference, coronal difference, apical difference) were evaluated using statistical analysis. RESULTS: In the assessment of the accuracy of surgical guides according to arch type, there are no statistically significant differences between maxilla and mandible. In the case of support type, tooth supported stents showed lower angle difference and length difference than tooth-tissue supported stents, which are statistically significant. CONCLUSION: Arch type does not affect the accuracy of surgical stents. But tooth support stents are more accurate than tooth-tissue support stents in the case of angle and length difference.
Dental Implants
;
Dental Models
;
Mandible
;
Maxilla
;
Printing, Three-Dimensional
;
Prostheses and Implants
;
Stents
;
Tooth
8.Identification of New Potential APE1 Inhibitors by Pharmacophore Modeling and Molecular Docking.
In Won LEE ; Jonghwan YOON ; Gunhee LEE ; Minho LEE
Genomics & Informatics 2017;15(4):147-155
Apurinic/apyrimidinic endonuclease 1 (APE1) is an enzyme responsible for the initial step in the base excision repair pathway and is known to be a potential drug target for treating cancers, because its expression is associated with resistance to DNA-damaging anticancer agents. Although several inhibitors already have been identified, the identification of novel kinds of potential inhibitors of APE1 could provide a seed for the development of improved anticancer drugs. For this purpose, we first classified known inhibitors of APE1. According to the classification, we constructed two distinct pharmacophore models. We screened more than 3 million lead-like compounds using the pharmacophores. Hits that fulfilled the features of the pharmacophore models were identified. In addition to the pharmacophore screen, we carried out molecular docking to prioritize hits. Based on these processes, we ultimately identified 1,338 potential inhibitors of APE1 with predicted binding affinities to the enzyme.
Antineoplastic Agents
;
Classification
;
DNA Repair
;
Molecular Docking Simulation
9.Structural Analysis of Recombinant Human Preproinsulins by Structure Prediction, Molecular Dynamics, and Protein-Protein Docking.
Sung Hun JUNG ; Chang Kyu KIM ; Gunhee LEE ; Jonghwan YOON ; Minho LEE
Genomics & Informatics 2017;15(4):142-146
More effective production of human insulin is important, because insulin is the main medication that is used to treat multiple types of diabetes and because many people are suffering from diabetes. The current system of insulin production is based on recombinant DNA technology, and the expression vector is composed of a preproinsulin sequence that is a fused form of an artificial leader peptide and the native proinsulin. It has been reported that the sequence of the leader peptide affects the production of insulin. To analyze how the leader peptide affects the maturation of insulin structurally, we adapted several in silico simulations using 13 artificial proinsulin sequences. Three-dimensional structures of models were predicted and compared. Although their sequences had few differences, the predicted structures were somewhat different. The structures were refined by molecular dynamics simulation, and the energy of each model was estimated. Then, protein-protein docking between the models and trypsin was carried out to compare how efficiently the protease could access the cleavage sites of the proinsulin models. The results showed some concordance with experimental results that have been reported; so, we expect our analysis will be used to predict the optimized sequence of artificial proinsulin for more effective production.
Computer Simulation
;
DNA, Recombinant
;
Humans*
;
Insulin
;
Molecular Dynamics Simulation*
;
Proinsulin
;
Protein Sorting Signals
;
Trypsin
10.Efficacy of a Once-Monthly Pill Containing Ibandronate and Cholecalciferol on the Levels of 25-Hydroxyvitamin D and Bone Markers in Postmenopausal Women with Osteoporosis.
In Jin CHO ; Ho Yeon CHUNG ; Sung Woon KIM ; Jae Won LEE ; Tae Won LEE ; Hye Soon KIM ; Sin Gon KIM ; Han Seok CHOI ; Sung Hee CHOI ; Chan Soo SHIN ; Ki Won OH ; Yong Ki MIN ; Jung Min KOH ; Yumie RHEE ; Dong Won BYUN ; Yoon Sok CHUNG ; Jeong Hyun PARK ; Dong Jin CHUNG ; Minho SHONG ; Eun Gyoung HONG ; Chang Beom LEE ; Ki Hyun BAEK ; Moo Il KANG
Endocrinology and Metabolism 2015;30(3):272-279
BACKGROUND: The present study evaluated the efficacy of a combination of ibandronate and cholecalciferol on the restoration of the levels of 25-hydroxyvitamin D (25[OH]D) and various bone markers in postmenopausal women with osteoporosis. METHODS: This was a randomized, double-blind, active-controlled, prospective 16-week clinical trial conducted in 20 different hospitals. A total of 201 postmenopausal women with osteoporosis were assigned randomly to one of two groups: the IBN group, which received a once-monthly pill containing 150 mg ibandronate (n=99), or the IBN+ group, which received a once-monthly pill containing 150 mg ibandronate and 24,000 IU cholecalciferol (n=102). Serum levels of 25(OH)D, parathyroid hormone (PTH), and various bone markers were assessed at baseline and at the end of a 16-week treatment period. RESULTS: After 16 weeks of treatment, the mean serum levels of 25(OH)D significantly increased from 21.0 to 25.3 ng/mL in the IBN+ group but significantly decreased from 20.6 to 17.4 ng/mL in the IBN group. Additionally, both groups exhibited significant increases in mean serum levels of PTH but significant decreases in serum levels of bone-specific alkaline phosphatase and C-telopeptide of type 1 collagen (CTX) at 16 weeks; no significant differences were observed between the groups. However, in subjects with a vitamin D deficiency, IBN+ treatment resulted in a significant decrease in serum CTX levels compared with IBN treatment. CONCLUSION: The present findings demonstrate that a once-monthly pill containing ibandronate and cholecalciferol may be useful for the amelioration of vitamin D deficiency in patients with postmenopausal osteoporosis. Moreover, this treatment combination effectively decreased serum levels of resorption markers, especially in subjects with a vitamin D deficiency, over the 16-week treatment period.
Alkaline Phosphatase
;
Cholecalciferol*
;
Collagen Type I
;
Female
;
Humans
;
Osteoporosis*
;
Osteoporosis, Postmenopausal
;
Parathyroid Hormone
;
Prospective Studies
;
Vitamin D Deficiency

Result Analysis
Print
Save
E-mail