1.A correlation study of necrotizing enterocolitis and encephalopathy of prematurity in premature infants with gestational age < 32 weeks
Ke ZHANG ; Weiwei LIN ; Mili XIAO ; Jianguo ZHOU ; Tian QIAN ; Lan HU ; Chao CHEN ; Rong ZHANG
Chinese Journal of Neonatology 2018;33(3):187-190
Objective To study the correlation of necrotizing enterocolitis (NEC) and encephalopathy of prematurity (EOP) in premature infants with gestational age (GA) < 32 weeks.Method From January 2009 to December 2014,clinical data of preterm infants (GA < 32 weeks) admitted to department of neonatology of Children's Hospital of Fudan University and received brain magnetic resonance imaging (MRI) at corrected GA of full term or near full term were collected.NEC patients were assigned into the NEC group.At the same time,patients with similar GA and birth weight without NEC were assigned into the control group.The incidence and MRI characteristics of EOP were studied using Chi-square method.Result A total of312 preterm infants were included in our study,104 in the NEC group,and 208 in the control group.The incidence of EOP in the NEC group was higher than the control group (27.9% vs.17.3%).The difference between the two groups were statistically significant (P =0.030).The incidence of non-cystic EOP in the NEC group was significantly higher than the control group (89.7% vs.63.9%,P =0.017).Conclusion NEC and EOP may be correlated in preterm infants with GA <32 weeks.Most of EOP were non-cystic injury.
2.Design and development of a portable multi-parameter monitoring system based on an 8Xc196Mc single-chip microcomputer
Xiao-Lan DU ; Bao-Ming WU ; Qing-Hua HE ; Yan LIU ; Jian XIAO ; Xiang-Dong LI
Journal of Third Military Medical University 2001;23(5):605-607
Objective To design and develop a portable multi -parameter life sign monitor. Methods Electrocardiogram (ECG). blood pressure(BP), breath frequency (BF), heart rate (HR) and body temperature (BT) in real time were recorded with a single-chip microprocessor 8Xc196Mc and a high-resolution (640×200) graphic liquid crystal display (LCD) through sign al detecting and processing techniques. Results This system cou ld display the ECG wave, and other parameters in real time dynamically. It could also provide a 24 hours trend graph for each parameter measured and exchange th e data through the serial communication interface (RS232) with the PC. C onclusion This portable monitoring system is capable of performing cont inuous monitoring and also has the capability to resist environmental interferen ce through the added design, so it can be used widely.

Result Analysis
Print
Save
E-mail