1.Establishment of Local Diagnostic Reference Levels for Pediatric Neck CT at Nine University Hospitals in South Korea
Jisun HWANG ; Hee Mang YOON ; Jae-Yeon HWANG ; Young Hun CHOI ; Yun Young LEE ; So Mi LEE ; Young Jin RYU ; Sun Kyoung YOU ; Ji Eun PARK ; Seok Kee LEE
Korean Journal of Radiology 2025;26(1):65-74
Objective:
To establish local diagnostic reference levels (DRLs) for pediatric neck CT based on age, weight, and water-equivalent diameter (WED) across multiple university hospitals in South Korea.
Materials and Methods:
This retrospective study analyzed pediatric neck CT examinations from nine university hospitals, involving patients aged 0–18 years. Data were categorized by age, weight, and WED, and radiation dose metrics, including volume CT dose index (CTDIvol) and dose length product, were recorded. Data retrieval and analysis were conducted using a commercially available dose-management system (Radimetrics, Bayer Healthcare). Local DRLs were established following the International Commission on Radiological Protection guidelines, using the 75th percentile as the reference value.
Results:
A total of 1159 CT examinations were analyzed, including 169 scans from Institution 1, 132 from Institution 2, 126 from Institution 3, 129 from Institution 4, 128 from Institution 5, 105 from Institution 6, 162 from Institution 7, 127 from Institution 8, and 81 from Institution 9. Radiation dose metrics increased with age, weight, and WED, showing significant variability both within and across institutions. For patients weighing less than 10 kg, the DRL for CTDIvol was 5.2 mGy. In the 10–19 kg group, the DRL was 5.8 mGy; in the 20–39 kg group, 7.6 mGy; in the 40–59 kg group, 11.0 mGy; and for patients weighing 60 kg or more, 16.2 mGy. DRLs for CTDIvol by age groups were as follows: 5.3 mGy for infants under 1 year, 5.7 mGy for children aged 1–4 years, 7.6 mGy for ages 5–9 years, 11.2 mGy for ages 10–14 years, and 15.6 mGy for patients 15 years or older.
Conclusion
Local DRLs for pediatric neck CT were established based on age, weight, and WED across nine university hospitals in South Korea.
2.Establishment of Local Diagnostic Reference Levels for Pediatric Neck CT at Nine University Hospitals in South Korea
Jisun HWANG ; Hee Mang YOON ; Jae-Yeon HWANG ; Young Hun CHOI ; Yun Young LEE ; So Mi LEE ; Young Jin RYU ; Sun Kyoung YOU ; Ji Eun PARK ; Seok Kee LEE
Korean Journal of Radiology 2025;26(1):65-74
Objective:
To establish local diagnostic reference levels (DRLs) for pediatric neck CT based on age, weight, and water-equivalent diameter (WED) across multiple university hospitals in South Korea.
Materials and Methods:
This retrospective study analyzed pediatric neck CT examinations from nine university hospitals, involving patients aged 0–18 years. Data were categorized by age, weight, and WED, and radiation dose metrics, including volume CT dose index (CTDIvol) and dose length product, were recorded. Data retrieval and analysis were conducted using a commercially available dose-management system (Radimetrics, Bayer Healthcare). Local DRLs were established following the International Commission on Radiological Protection guidelines, using the 75th percentile as the reference value.
Results:
A total of 1159 CT examinations were analyzed, including 169 scans from Institution 1, 132 from Institution 2, 126 from Institution 3, 129 from Institution 4, 128 from Institution 5, 105 from Institution 6, 162 from Institution 7, 127 from Institution 8, and 81 from Institution 9. Radiation dose metrics increased with age, weight, and WED, showing significant variability both within and across institutions. For patients weighing less than 10 kg, the DRL for CTDIvol was 5.2 mGy. In the 10–19 kg group, the DRL was 5.8 mGy; in the 20–39 kg group, 7.6 mGy; in the 40–59 kg group, 11.0 mGy; and for patients weighing 60 kg or more, 16.2 mGy. DRLs for CTDIvol by age groups were as follows: 5.3 mGy for infants under 1 year, 5.7 mGy for children aged 1–4 years, 7.6 mGy for ages 5–9 years, 11.2 mGy for ages 10–14 years, and 15.6 mGy for patients 15 years or older.
Conclusion
Local DRLs for pediatric neck CT were established based on age, weight, and WED across nine university hospitals in South Korea.
3.Establishment of Local Diagnostic Reference Levels for Pediatric Neck CT at Nine University Hospitals in South Korea
Jisun HWANG ; Hee Mang YOON ; Jae-Yeon HWANG ; Young Hun CHOI ; Yun Young LEE ; So Mi LEE ; Young Jin RYU ; Sun Kyoung YOU ; Ji Eun PARK ; Seok Kee LEE
Korean Journal of Radiology 2025;26(1):65-74
Objective:
To establish local diagnostic reference levels (DRLs) for pediatric neck CT based on age, weight, and water-equivalent diameter (WED) across multiple university hospitals in South Korea.
Materials and Methods:
This retrospective study analyzed pediatric neck CT examinations from nine university hospitals, involving patients aged 0–18 years. Data were categorized by age, weight, and WED, and radiation dose metrics, including volume CT dose index (CTDIvol) and dose length product, were recorded. Data retrieval and analysis were conducted using a commercially available dose-management system (Radimetrics, Bayer Healthcare). Local DRLs were established following the International Commission on Radiological Protection guidelines, using the 75th percentile as the reference value.
Results:
A total of 1159 CT examinations were analyzed, including 169 scans from Institution 1, 132 from Institution 2, 126 from Institution 3, 129 from Institution 4, 128 from Institution 5, 105 from Institution 6, 162 from Institution 7, 127 from Institution 8, and 81 from Institution 9. Radiation dose metrics increased with age, weight, and WED, showing significant variability both within and across institutions. For patients weighing less than 10 kg, the DRL for CTDIvol was 5.2 mGy. In the 10–19 kg group, the DRL was 5.8 mGy; in the 20–39 kg group, 7.6 mGy; in the 40–59 kg group, 11.0 mGy; and for patients weighing 60 kg or more, 16.2 mGy. DRLs for CTDIvol by age groups were as follows: 5.3 mGy for infants under 1 year, 5.7 mGy for children aged 1–4 years, 7.6 mGy for ages 5–9 years, 11.2 mGy for ages 10–14 years, and 15.6 mGy for patients 15 years or older.
Conclusion
Local DRLs for pediatric neck CT were established based on age, weight, and WED across nine university hospitals in South Korea.
4.Establishment of Local Diagnostic Reference Levels for Pediatric Neck CT at Nine University Hospitals in South Korea
Jisun HWANG ; Hee Mang YOON ; Jae-Yeon HWANG ; Young Hun CHOI ; Yun Young LEE ; So Mi LEE ; Young Jin RYU ; Sun Kyoung YOU ; Ji Eun PARK ; Seok Kee LEE
Korean Journal of Radiology 2025;26(1):65-74
Objective:
To establish local diagnostic reference levels (DRLs) for pediatric neck CT based on age, weight, and water-equivalent diameter (WED) across multiple university hospitals in South Korea.
Materials and Methods:
This retrospective study analyzed pediatric neck CT examinations from nine university hospitals, involving patients aged 0–18 years. Data were categorized by age, weight, and WED, and radiation dose metrics, including volume CT dose index (CTDIvol) and dose length product, were recorded. Data retrieval and analysis were conducted using a commercially available dose-management system (Radimetrics, Bayer Healthcare). Local DRLs were established following the International Commission on Radiological Protection guidelines, using the 75th percentile as the reference value.
Results:
A total of 1159 CT examinations were analyzed, including 169 scans from Institution 1, 132 from Institution 2, 126 from Institution 3, 129 from Institution 4, 128 from Institution 5, 105 from Institution 6, 162 from Institution 7, 127 from Institution 8, and 81 from Institution 9. Radiation dose metrics increased with age, weight, and WED, showing significant variability both within and across institutions. For patients weighing less than 10 kg, the DRL for CTDIvol was 5.2 mGy. In the 10–19 kg group, the DRL was 5.8 mGy; in the 20–39 kg group, 7.6 mGy; in the 40–59 kg group, 11.0 mGy; and for patients weighing 60 kg or more, 16.2 mGy. DRLs for CTDIvol by age groups were as follows: 5.3 mGy for infants under 1 year, 5.7 mGy for children aged 1–4 years, 7.6 mGy for ages 5–9 years, 11.2 mGy for ages 10–14 years, and 15.6 mGy for patients 15 years or older.
Conclusion
Local DRLs for pediatric neck CT were established based on age, weight, and WED across nine university hospitals in South Korea.
5.Establishment of Local Diagnostic Reference Levels for Pediatric Neck CT at Nine University Hospitals in South Korea
Jisun HWANG ; Hee Mang YOON ; Jae-Yeon HWANG ; Young Hun CHOI ; Yun Young LEE ; So Mi LEE ; Young Jin RYU ; Sun Kyoung YOU ; Ji Eun PARK ; Seok Kee LEE
Korean Journal of Radiology 2025;26(1):65-74
Objective:
To establish local diagnostic reference levels (DRLs) for pediatric neck CT based on age, weight, and water-equivalent diameter (WED) across multiple university hospitals in South Korea.
Materials and Methods:
This retrospective study analyzed pediatric neck CT examinations from nine university hospitals, involving patients aged 0–18 years. Data were categorized by age, weight, and WED, and radiation dose metrics, including volume CT dose index (CTDIvol) and dose length product, were recorded. Data retrieval and analysis were conducted using a commercially available dose-management system (Radimetrics, Bayer Healthcare). Local DRLs were established following the International Commission on Radiological Protection guidelines, using the 75th percentile as the reference value.
Results:
A total of 1159 CT examinations were analyzed, including 169 scans from Institution 1, 132 from Institution 2, 126 from Institution 3, 129 from Institution 4, 128 from Institution 5, 105 from Institution 6, 162 from Institution 7, 127 from Institution 8, and 81 from Institution 9. Radiation dose metrics increased with age, weight, and WED, showing significant variability both within and across institutions. For patients weighing less than 10 kg, the DRL for CTDIvol was 5.2 mGy. In the 10–19 kg group, the DRL was 5.8 mGy; in the 20–39 kg group, 7.6 mGy; in the 40–59 kg group, 11.0 mGy; and for patients weighing 60 kg or more, 16.2 mGy. DRLs for CTDIvol by age groups were as follows: 5.3 mGy for infants under 1 year, 5.7 mGy for children aged 1–4 years, 7.6 mGy for ages 5–9 years, 11.2 mGy for ages 10–14 years, and 15.6 mGy for patients 15 years or older.
Conclusion
Local DRLs for pediatric neck CT were established based on age, weight, and WED across nine university hospitals in South Korea.
6.Sensitive Detection of Hypochlorous Acid Using Porphyrin-pyridyl Conjugated Oligomer-based Fluorescent Nanoprobe
Ji-Yan HUANG ; Mi-Xue CHEN ; Jin-Ling LI ; Yi XIAO ; Hong-Mei HUANG ; You-Yu ZHANG
Chinese Journal of Analytical Chemistry 2024;52(8):1132-1140,中插6-中插11
Conjugated oligomers,as analogues of conjugated polymers,allow for constructing ultrafine fluorescent nanoparticles with improved sensing sensitivity due to their more precisely defined molecular structure and smaller size.Herein,a new porphyrin-pyridyl conjugated oligomer,i.e.,Zn-TPP-OMe,was designed and synthesized via Sonogashira coupling strategy and a super-small(~2.0 nm)water-soluble fluorescent nanoprobe(Zn-TPP-OMe nanoparticles(NPs))was subsequent obtained by nanoprecipitation method.Due to the addition reaction of chlorine atom to porphyrin ring,the fluorescence intensity of Zn-TPP-OMe NPs at 619-660 nm significantly decreased with increasing HCLO concentration.Meanwhile,Zn-TPP-OMe NPs aggregated obviously after adding HClO,achieving enhanced fluorescence quenching.The fluorescence detection mechanism was verified by transmission electron microscopy(TEM),proton nuclear magnetic resonance(1H NMR)and high resolution mass spectrometry(HRMS)analyses.The experimental results indicated that the porphyrin-pyridyl conjugated oligomer nanosystem had high sensitivity(LOD=0.005 μmol/L)and excellent selectivity in detection of HClO,and was successfully applied to the sensing of HClO in actual water samples.
7.Relationship of MicroRNA according to Immune Components of Breast Milk in Korean Lactating Mothers
You Jin CHOI ; Da Hye LEE ; Jeonglyn SONG ; Ki-Uk KIM ; Hyeyoung MIN ; Sung-Hoon CHUNG ; Tae Hyeong KIM ; Chae-Young KIM ; Insoo KANG ; Na Mi LEE ; Dae Yong YI
Pediatric Gastroenterology, Hepatology & Nutrition 2024;27(5):322-331
Purpose:
Human breast milk (HBM) contains immune components that produced and delivered from the mother along with nutrients necessary for the baby. MicroRNA (miRNA) is a small noncoding RNA molecule, that is used as an ideal biomarker for diagnosis and prognosis of various diseases and are more abundant in HBM. We analyzed and compared the immune components and miRNAs of HBM.
Methods:
HBM were collected from 20 healthy breastfeeding mothers. We measured the amount of lactoferrin, lysozyme, and immunoglobulin A (IgA) and extracted the miRNAs from each breast milk samples. Next, the top 5 and bottom 5 expressed miRNAs were compared and analyzed based on the amounts of the 3 immune components.
Results:
The mean levels and ranges of lactoferrin, lysozyme, and IgA were 6.33 (2.24–14.77)×106 ng/mL, 9.90 (1.42–17.59)×107 pg/mL, and 6.64 (0.48–20.01)×105 ng/mL, respectively. The miRNAs concentration per 1 mL of skim milk was 40.54 (14.95–110.01) ng/μL. Comparing the bottom 5 and top 5 groups of each immune component, 19 miRNAs were significantly upregulated (6, 9, and 4 targeting lactoferrin, lysozyme, and IgA, respectively) and 21 were significantly downregulated (4, 9, and 8 targeting lactoferrin, lysozyme, and IgA, respectively). There were no miRNAs that were expressed significantly higher or lower in common to all 3 components.However, 2 and 3 miRNAs were commonly overexpressed and underexpressed, in the top 5 groups of lysozyme and IgA concentrations.
Conclusion
We identified the immune components and miRNAs in breast milk and found that each individual has different ingredients.
8.Relationship of MicroRNA according to Immune Components of Breast Milk in Korean Lactating Mothers
You Jin CHOI ; Da Hye LEE ; Jeonglyn SONG ; Ki-Uk KIM ; Hyeyoung MIN ; Sung-Hoon CHUNG ; Tae Hyeong KIM ; Chae-Young KIM ; Insoo KANG ; Na Mi LEE ; Dae Yong YI
Pediatric Gastroenterology, Hepatology & Nutrition 2024;27(5):322-331
Purpose:
Human breast milk (HBM) contains immune components that produced and delivered from the mother along with nutrients necessary for the baby. MicroRNA (miRNA) is a small noncoding RNA molecule, that is used as an ideal biomarker for diagnosis and prognosis of various diseases and are more abundant in HBM. We analyzed and compared the immune components and miRNAs of HBM.
Methods:
HBM were collected from 20 healthy breastfeeding mothers. We measured the amount of lactoferrin, lysozyme, and immunoglobulin A (IgA) and extracted the miRNAs from each breast milk samples. Next, the top 5 and bottom 5 expressed miRNAs were compared and analyzed based on the amounts of the 3 immune components.
Results:
The mean levels and ranges of lactoferrin, lysozyme, and IgA were 6.33 (2.24–14.77)×106 ng/mL, 9.90 (1.42–17.59)×107 pg/mL, and 6.64 (0.48–20.01)×105 ng/mL, respectively. The miRNAs concentration per 1 mL of skim milk was 40.54 (14.95–110.01) ng/μL. Comparing the bottom 5 and top 5 groups of each immune component, 19 miRNAs were significantly upregulated (6, 9, and 4 targeting lactoferrin, lysozyme, and IgA, respectively) and 21 were significantly downregulated (4, 9, and 8 targeting lactoferrin, lysozyme, and IgA, respectively). There were no miRNAs that were expressed significantly higher or lower in common to all 3 components.However, 2 and 3 miRNAs were commonly overexpressed and underexpressed, in the top 5 groups of lysozyme and IgA concentrations.
Conclusion
We identified the immune components and miRNAs in breast milk and found that each individual has different ingredients.
9.Relationship of MicroRNA according to Immune Components of Breast Milk in Korean Lactating Mothers
You Jin CHOI ; Da Hye LEE ; Jeonglyn SONG ; Ki-Uk KIM ; Hyeyoung MIN ; Sung-Hoon CHUNG ; Tae Hyeong KIM ; Chae-Young KIM ; Insoo KANG ; Na Mi LEE ; Dae Yong YI
Pediatric Gastroenterology, Hepatology & Nutrition 2024;27(5):322-331
Purpose:
Human breast milk (HBM) contains immune components that produced and delivered from the mother along with nutrients necessary for the baby. MicroRNA (miRNA) is a small noncoding RNA molecule, that is used as an ideal biomarker for diagnosis and prognosis of various diseases and are more abundant in HBM. We analyzed and compared the immune components and miRNAs of HBM.
Methods:
HBM were collected from 20 healthy breastfeeding mothers. We measured the amount of lactoferrin, lysozyme, and immunoglobulin A (IgA) and extracted the miRNAs from each breast milk samples. Next, the top 5 and bottom 5 expressed miRNAs were compared and analyzed based on the amounts of the 3 immune components.
Results:
The mean levels and ranges of lactoferrin, lysozyme, and IgA were 6.33 (2.24–14.77)×106 ng/mL, 9.90 (1.42–17.59)×107 pg/mL, and 6.64 (0.48–20.01)×105 ng/mL, respectively. The miRNAs concentration per 1 mL of skim milk was 40.54 (14.95–110.01) ng/μL. Comparing the bottom 5 and top 5 groups of each immune component, 19 miRNAs were significantly upregulated (6, 9, and 4 targeting lactoferrin, lysozyme, and IgA, respectively) and 21 were significantly downregulated (4, 9, and 8 targeting lactoferrin, lysozyme, and IgA, respectively). There were no miRNAs that were expressed significantly higher or lower in common to all 3 components.However, 2 and 3 miRNAs were commonly overexpressed and underexpressed, in the top 5 groups of lysozyme and IgA concentrations.
Conclusion
We identified the immune components and miRNAs in breast milk and found that each individual has different ingredients.
10.Evaluation of Burnout and Contributing Factors in Imaging Cardiologists in Korea
You-Jung CHOI ; Kang-Un CHOI ; Young-Mee LEE ; Hyun-Jung LEE ; Inki MOON ; Jiwon SEO ; Kyu KIM ; So Ree KIM ; Jihoon KIM ; Hong-Mi CHOI ; Seo-Yeon GWAK ; Minkwan KIM ; Minjeong KIM ; Kyu-Yong KO ; Jin Kyung OH ; Jah Yeon CHOI ; Dong-Hyuk CHO ; On behalf of the Korean Society of Echocardiography Heart Imagers of Tomorrow
Journal of Korean Medical Science 2024;40(5):e21-
Background:
We aimed to examine the prevalence of burnout among imaging cardiologists in Korea and to identify its associated factors.
Methods:
An online survey of imaging cardiologists affiliated with university hospitals in Korea was conducted using SurveyMonkey ® in November 2023. The validated Korean version of the Maslach Burnout Inventory-Human Service Survey was used to assess burnout across three dimensions: emotional exhaustion, depersonalization, and lack of personal accomplishment. Data on demographics, work environment factors, and job satisfaction were collected using structured questionnaires.
Results:
A total of 128 imaging cardiologists (46.1% men; 76.6% aged ≤ 50 years) participated in the survey. Regarding workload, 74.2% of the respondents interpreted over 50 echocardiographic examinations daily, and 53.2% allocated > 5 of 10 working sessions per week to echocardiographic laboratory duties. Burnout levels were high, with a significant proportion of participants experiencing emotional exhaustion (28.1%), depersonalization (63.3%), and a lack of personal accomplishment (92.2%). Younger age (< 50 years) was correlated with higher emotional exhaustion risk, while more research time was protective against burnout in the depersonalization domain. Factors, such as being single, living with family, and specific job satisfaction facets, including uncontrollable workload and value mismatch, were associated with varying levels of burnout risk across different dimensions
Conclusion
Our study underscores the high burnout rates among Korean imaging cardiologists, attributed to factors such as the subjective environment and job satisfaction.Hence, evaluating and supporting cardiologists in terms of individual values and subjective factors are important to effectively prevent burnout..

Result Analysis
Print
Save
E-mail