1.Evaluation of left ventricular myocardial function after transcatheter aortic valve implantation in severe aortic stenosis patients with preserved left ventricular ejection fraction by two-dimensional speckle tracking imaging technology and pressure-strain loop
Qiumei GAO ; Maolong SU ; Bin WANG ; Xu CHEN ; Kunhui HUANG ; Jian WU ; Yongli ZENG
Chinese Journal of Ultrasonography 2021;30(11):975-981
Objective:To quantitatively evaluate the left ventricular myocardial strains and global myocardial work indices in severe aortic stenosis(AS) patients with preserved left ventricular ejection fraction (LVEF) undergoing transcatheter aortic valve implantation (TAVI) by using two-dimensional speckle tracking imaging (2D-STI) technology and pressure-strain loop (PSL).Methods:Twenty patients undergoing TAVI from January to November 2020 in Cardiovascular Hospital of Xiamen University were selected as the TAVI group, and 20 healthy volunteers (with the matched gender, age) were selected as the control group at the same period. Left ventricular global longitudinal strain (GLS), endocardial, middle, epicardial myocardial longitudinal strain (LSendo, LSmid, LSepi) were measured by 2D-STI. The correlation between aortic pressure and the left ventricular systolic pressure invasively measured by cardiac catheterization, and blood pressure and the left ventricular systolic pressure non-invasively measured by peripheral brachial artery systolic blood pressure combined with Doppler-derived mean aortic gradient was separately compared. The non-invasive PSL was used to evaluate the global work index (GWI), global constructive work (GCW), global wasted work (GWW) and global work efficiency (GWE). The differences of the myocardial strains and myocardial work indices between the two groups, including controls, patients with preoperation, 1 week and 3 months after TAVI, were compared.Results:Compared with the control group, GLS, LSendo, LSmid and LSepi of the left ventricle in the TAVI preoperation group were decreased (all P<0.05), LSendo increased at 1 week after TAVI, and GLS, LSendo, LSmid, and LSepi increased at 3 months after TAVI (all P<0.05). In the TAVI preoperative, invasive aortic pressure was positively correlated with peripheral brachial artery systolic blood pressure, invasive left ventricular systolic pressure was positively correlated with non-invasive left ventricular systolic pressure ( r=0.658, 0.565; all P<0.01). Compared with the control group, the preoperative the GWE decreased and the GWW increased in the TAVI group (all P<0.05). Compared with the preoperation, the GWI and GCW decreased at 1 week after TAVI (all P<0.05). Compared with 1 week after TAVI, GWI, GCW, GWE increased and GWW decreased at 3 months after TAVI (all P<0.05). Conclusions:The application of 2D-STI and PSL can quantitatively evaluate the left ventricular myocardial systolic function before and after TAVI in AS patients, which can provide a more objective reference index for clinical evaluation of the efficacy of TAVI.
2.Evaluation of left ventricular systolic function and global myocardial work in the patients with left bundle branch pacing operation by two-dimensional multi-layered speckle tracking imaging
Biqin LIN ; Binni CAI ; Linlin LI ; Zhenguo LIN ; Yueming WU ; Qiumei GAO ; Xinyi HUANG ; Maolong SU
Chinese Journal of Ultrasonography 2020;29(8):645-651
Objective:To assess the changes of left ventricular systolic function and global synchronization and myocardial work in patients with left bundle branch pacing (LBBP) by two-dimensional multi-layered speckle tracking imaging.Methods:Forty-two patients with Ⅱ degree Ⅱ type or Ⅲ degree atrioventricular block (AVB) in the Cardiovascular Hospital of Xiamen University from April to December 2019 were selected as pacing group, which were further divided into two groups according to different pacemaker modes: twenty patients with right ventricular septal pacing (RVSP), twenty-two patients with LBBP, and twenty patients with normal ECG and cardiac structure were enrolled as control group. Echocardiography of pacing group and control group was performed and analyzed. The left ventricular subendocardial longitudinal strain peak(LSendo), the middle layer myocardial longitudinal strain peak(LSmid), subepicardial longitudinal strain peak(LSepi), global myocardial longitudinal strain peak(GLS), peak strain dispersion (PSD), global work index (GWI), global constructive work (GCW), global wasted work (GWW) and global work efficiency (GWE) were acquired. The differences among the three groups were analyzed and the high difference indexes were screened by statistical modeling.Results:LSendo in three groups had no difference ( P>0.05). LSmid, LSepi, GLS in the control group, LBBP group and RVSP groups were decreased gradually ( P<0.05). GLS in LBBP group was higher than in RVSP group ( P<0.05). Compared with the control group, the increases of QRS and PSD in LBBP group were not statistically significant ( P>0.05), while the decreases of QRS and PSD in LBBP group were statistically significant compared with the RVSP group ( P<0.05). The values of GCW among three groups had no statistical significance ( P>0.05). Compared with the control group, the decrease of GWI in LBBP group was not statistically significant ( P>0.05), while the increase of GWW and the decrease of GWE were statistically significant ( P<0.05). Compared with the RVSP group, the increases of GWI and GWE and the decrease of GWW in LBBP group were statistically significant ( P<0.05). QRS, LSendo, GLS, LSmid, left ventricular apex rotation to basal rotation peak time(ApexBase period) were the indexes with significant difference among LBBP and RVSP groups and all index characteristics showed better in LBBP than RVSP group. Conclusions:Two-dimensional multi-layered speckle tracking imaging can be used to evaluate the effect of LBBP on left ventricular systolic function and global synchronization and myocardial work. LBBP longitudinal mechanical synchronization is better than right ventricular septal pacing by improving the peak global myocardial longitudinal strain and myocardial work after pacemaker.
3.Evaluation of cardiac synchrony in patients with permanent left bundle branch area pacing by tissue Doppler imaging
Xinyi HUANG ; Binni CAI ; Linlin LI ; Maolong SU
Chinese Journal of Ultrasonography 2019;28(4):289-294
Objective To compare and analyze the synchrony of cardiac contraction when left bundle branch area pacing ( LBBP ) using tissue Doppler imaging ( TDI ) . Methods T wenty‐four patients with LBBP and 20 patients with right ventricular pacing ( RVP ) were enrolled in the study . Among them , 35 cases were diagnosed as sick sinus syndrome ( SSS ) and 9 cases were diagnosed as Ⅱ or Ⅲ degree atrioventricular block ( AVB) before operation . Echocardiographic images were collected with ventricular pacemaker‐on ,and patients with SSS in LBBP group under the condition of pacemaker program control also collected the image of self‐conduction . TDI was used to measure time of the peak velocity ( T s ) of myocardial contraction in the left ventricular 12 segments ,right ventricle 2 segments ,and atrial 3 walls .The difference between the basal segment of left ventricular lateral wall and right ventricular free wall ( T s‐LV‐RV ) ,the mean value of the right ventricular 2 segments ( T s‐2‐RV ) ,the average( T s‐12‐LV ) and standard deviation ( T sd‐12‐LV ) of the left ventricular 12 segments ,and the difference in peak systolic time among 3 walls T AL‐R ,T AI‐R ,T AL‐I were calculated . Results Compared with the RVP pacing state ,the parameters of left ventricular systolic synchrony in LBBP pacing were shortened ,and the difference was statistically significant ( P < 0 .05 ) . T here was no significant difference in parameters of left ventricular/right ventricular systolic synchrony and cardiac function between the LBBP group and the self‐conduction status ( P>0 .05) . Conclusions Left ventricular systolic synchrony is superior to RVP in LBBP pacing ,and left/right ventricular systolic synchrony and cardiac function are not different from self‐conduction . LBBP is a new physiological pacing . TDI is able to quantitatively assess cardiac systolic synchrony .
4.Prediction of left ventricular systolic function after repair or replacement of mitral regurgitation by two‐dimensional speckle tracking imaging
Chinese Journal of Ultrasonography 2019;28(6):487-492
To investigate the predictive value of left ventricular longitudinal strain parameters in patients with severe mitral regurgitation before surgery on the reduction of transthoracic automatic left ventricular three -dimensional ejection fraction ( Heart Model EF ) aftersurgery . Methods Clinical data ,two‐dimensional and three‐dimensional dynamic images of 33 patients preparing for mitral regurgitation surgery and 39 healthy adults were obtained . T wo‐dimensional strain parameters of left ventricular ,and Heart Model EF of left ventricular were obtained by software analysis . Healthy adults were set as control group ,and patients with mitral regurgitation were divided into M R 1 group ( Heart M odel EF did not reduce or decrease ≤ 10% ) and M R2 group ( Heart M odel EF reduced > 10% ) according to the degree of Heart M odel EF reduction 6 months after surgery . Logistic regression analysis was used to evaluate the parameters related to the decrease of Heart Model EF 6 months after operation in the longitudinal strain parameters of left ventricular myocardium before operation ,and the critical values of sensitive predictive parameters were obtained by drawing receiver operating characteristic ( ROC ) curve . Results ①T he absolute values of left ventricular strain parameters in M R 2 group were significantly lower than those in control group and M R1 group ( P < 0 .05 ) . T he results of univariate Logistic regression analysis and ROC curve analysis showed that the left ventricular systolic global peak longitudinal strain ( GLS) ,left ventricular systolic basal peak longitudinal strain ( BLS) and left ventricular systolic inferior wall peak longitudinal strain ( I‐LS) can be used as predictors of post‐operative Heart Model EF reduction ( P <0 .05) . T he OR ( 95% CI ) value ,cut‐off value ,sensitivity and specificity were 0 .752 ( 0 .753 ,0 .987 ) ,-19 .35 ,67% ,92% ( GLS) ,0 .757 ( 0 .590 ,0 .970 ) ,-19 .01 ,78% ,77% ( BLS ) and 0 .821 ( 0 .675 ,0 .998 ) ,-18 .43 ,67% ,92% ( I‐LS ) ,respectively . ② T he multivariate logistic regression analysis of left ventricular strain parameters showed that only BLS can be used as predictors of post‐operative EF reduction . T he OR ( 95% CI ) value and P value were 0 .757 ( 0 .590 ,0 .970 ) and 0 .028 , respectively . Conclusions Two‐dimensional speckle tracking imaging has the ability to detect preoperative subclinical left ventricular dysfunction ,and is a reliable reference for selecting surgical timing for patients with severe mitral regurgitation . In addition to left ventricular GLS ,left ventricular BLS and left ventricular I‐LS can also predict postoperative left ventricular dysfunction ,among w hich left ventricular BLS is more significant .
5.Comparative study of left ventricular hemodynamic changes after Revivent surgery by dual‐modality imaging
Huimin WANG ; Maolong SU ; Guosheng XIAO ; Bin WANG ; Guoming ZHANG ; Hao YOU ; Zhi LIN ; Xu CHEN ; Xinyu WANG ; Jian WANG ; Zhiwei ZHAO ; Yan WANG
Chinese Journal of Ultrasonography 2019;28(7):588-594
Objective To investigate the hemodynamic changes before and after Revivent surgery in patients with left ventricular apical aneurysm by cardiac magnetic resonance imaging ( CM R ) and echocardiography . Methods Twenty‐two cases with left ventricular apical aneurysm were examined by two‐dimensional and three‐dimensional transthoracic echocardiography 1 week before operation ,1 month and 12 months after operation ,by CM R 1 week before operation and 12 months after operation .Left ventricular end‐diastolic volume( LVEDV ) ,left ventricular end‐systolic volume ( LVESV ) ,left ventricular end‐diastolic diameter ( LVEDd ) , left ventricular end‐systolic diameter ( LVESd ) , left ventricular ejection fraction ( LVEF) ,stroke volume ( SV ) ,stroke output index ( SVI) ,cardiac output ( CO ) and cardiac output index ( CI) were quantitatively measured and statistical analysis were performed . Results T here were significant differences between preoperation and 1 month after operation for the measurements of LVEDV ,LVESV , LVEDd and LVEF by both CM R and echocardiography ( all P < 0 .05 ) . Compared with preoperation , LVESd decreased significantly 12 months after operation ( P <0 .01) . However ,there were no significant differences between preoperation and 1 or 12 months after operation for the measurements of SV ,SVI ,CO and CI ( all P > 0 .05 ) . T he consistency between CM R and echocardiography measurements was good . Conclusions Revivent surgery provides an effective and feasible treatment for patients with left ventricular apical ventricular aneurysm . T he dual‐modality imaging with CM R and echocardiography are reliable technical means to evaluate the changes of left ventricular heamodynamiscs during the perioperative period of Revivent
7.Assessment of left ventricular hemodynamics and systolic function in patients with apical aneurysm after percutaneous ventricular restoration by echocardiography
Yujing MA ; Bin WANG ; Maolong SU ; Xu CHEN ; Xinyu WANG ; Xin DU ; Huimin WANG ; Xinyi HUANG ; Yueming WU ; Biqin LIN ; Jinghui CHEN
Chinese Journal of Ultrasonography 2018;27(8):656-660
Objective To evaluate the changes of left ventricular hemodynamics and systolic function in patients with apical aneurysm after percutaneous ventricular restoration ( PVR) by echocardiography . Methods Fifty patients with apical aneurysm were divided into PVR group ( 25 cases) and conservative treatment group ( control group ,25 cases ) . Two-dimensional transthoracic echocardiography ( 2D-TTE ) combined with real-time three-dimensional transesophageal echocardiography( RT-3DTEE) were applied for all the subjects in PVR group on preoperative ,one week after operaction ,three months after operaction and in control group on initial stage of prevent ventricular remodeling therapy ,one week after therapy ,three months after therapy to obtain left ventricular end-diastolic diameter( LVEDD) ,left ventricular end-systolic diameter( LVSDD) ,left ventricular end-diastolic volume( EDV ) ,end-systolic volume( ESV ) ,left ventricular ejection fraction( LVEF) ,left ventricular fractional shortening ( LVFS ) ,body surface area ( BSA ) ,stroke volume( SV) ,stroke volume index ( SVI) ,cardiac output ( CO ) ,cardiac output index ( CI) . Results There were significant differences in all parameters( P < 0 .05) especially in LVEF and SVI( P < 0 .01) between PVR group and control group in the following three months after operaction ,while there was no significant difference of the following one week after operaction( P > 0 .05) .Compared with preoperative ,there was no difference in all parameters in the following one week after operaction ( P > 0 .05) ,there was significant increase in SV and significant reduce in LVEDD and EDV ( P < 0 .01) between preoperative and in the following three months after operaction ,while there was no significant difference between preoperative and in the following one week after operaction ( P > 0 .05 ) .For the control group there was no significant difference between initial stage of prevevt ventricular remodeling therapy and in the following one week or three months after operaction .Conclusions PVR has a definite effect on left ventricular hemodynamics and systolic function in patients with apical aneurysm in the short term ,while 2D-TTE and RT-3DTEE provides a reliable basis for clinical to evaluate the effect of the PVR .
8.Immediate effect of percutaneous ventricular restoration on cardiac output of ischemic cardiomyopathy patients with apical aneurysm
Jian WANG ; Keke LAI ; Zheyi ZHANG ; Maolong SU ; Yan WANG
Chinese Journal of Interventional Cardiology 2017;25(3):133-137
Objective To evaluate the immediate effect of percutaneous ventricular restoration (PVR) using the PARACHUTE system in ischemic cardiomyopathy patients with apical aneurysm.Methods The study included 25 patients who received PARACHUTE partitioning device (PVD) implantation in the Xiamen Cardiovascular Hospital between January 2015 to December 2016.Invasive left ventricular hemodynamic assessments as well as cardiac output and cardiac output index were analyzed.Results Twenty-five patients [mean age (65.4±11.9) years] suffered from left ventricular aneurysm and heart failure patients after anterior myocardial infarction were enrolled.Ventricular partitioning device implantation was successful in 24/25 (96.0%) patients.PVR was failed in 1 patient due to unable to land the PVD in a satisfactory location.After implantation, a significant increase in cardiac output [(3.83±0.72) L/min vs.(4.85±0.93) L/min, P<0.01] and cardiac index [(2.32±0.74) L/(min·m2) vs.(2.90±0.82) L/(min·m2), P<0.01] was found.Conclusions Our preliminary experience on percutaneous ventricular restoration using PARACHUTE system demonstrates its feasibility and safety with increase in cardiac output and cardiac index immediately following the device implantation.
9.Safety and Efficacy of Percutaneous Ventricular Partitioning in Ischemic Heart Failure Patients With Apical Aneurysm
Jian WANG ; Bin WANG ; Guosheng XIAO ; Tao YE ; Mingri ZHENG ; Maolong SU ; Feng QIU ; Keke LAI ; Qian YANG ; Hongmei WEN ; Yan WANG
Chinese Circulation Journal 2016;31(8):775-779
Objective: To evaluate the safety and efifcacy of percutaneous ventricular partitioning (PVP) in ischemic heart failure (IHF) patients with apical aneurysm. Methods: A total of 19 IHF patients with apical aneurysm at the age of (68.1 ± 8.2) years were enrolled. The patients received PVP operation with adequate clinical and medical imaging examinations; the safety of operation was evaluated and post-operative clinical events with cardiac function were followed-up. Results: There were 18/19 (95%) patients with successful PVP and 1 had to stop the operation due to unsatisfactory landing of ventricular partitioning device. 2 patients suffered from vessel access related complication and received femoral artery stent implantation. With (252 ± 170) days follow-up study, no post-operative device failure, cardiac death, thromboembolism and HF re-hospitalization occurred. At 3 months after operation, the patients had improved NYHA classiifcation (2.72 ± 0.67) vs (1.67 ± 0.59) and 6 min walk test (462 ± 96) m vs (484 ± 87) m, bothP<0.01. Echocardiography indicated that post-operative left ventricle end-diastolic volume index (LVEDVI) decreased form (137.4 ± 19.1) ml/m2 to (125.6 ± 18.5) ml/m2,P=0.0056 and LVESVI decreased from (89.7 ± 22.3) ml/m2 to (78.8 ± 20.7) ml/m2,P=0.0019; while LVEF increased from (34.8 ± 8.13) % to (41.3 ± 6.2) %, P=0.031. Conclusion: Our preliminary experience showed that with adequate evaluation, PVP was safe and effective in IHF patients with apical aneurysm; short-term follow-up study implied the improved hemodynamic and cardiac function.
10.Preliminary study of the relationship between the ischemic mitral regurgitation mechanism and geometric structure of the mitral valve in the papillary muscle dysfunction
Xiaofang ZHONG ; Jing WANG ; Maolong SU ; Xiaoyang HUANG
Chinese Journal of Ultrasonography 2014;(11):925-929
Objective To study the relationship between ischemic mitral regurgitation and geometric angles of the mitral valve leaflets in patients with coronary artery disease and papillary muscle dysfunction by transesophageal echocardiography(TEE) ,and to evaluate anatomy and pathophysiology mechanicm of the ischemic mitral regurgitation with left ventricular papillary muscle dysfunction .Methods A total of 84 subjects were enrolled in this study .All of the subjects were divided into group A (healthy volunteers constituted the control group ,n =40) ,group B (chronic inferior or posterior myocardial infarction patients with papillary muscle dysfunction group ,n =44) ,group C(patients from group B after mitral valvuloplasty surgery ,n = 20) .The relationship between mitral regurgitation and geometric angles of the mitral valve leaflets and mitral annulus were studied by TEE .Results Geometric angle between the mitral valve leaflets and mitral annulus were significantly larger in group B ,and geometric angles of the mitral valve leaflets and mitral annulus was positive correlated with degree of mitral regurgitation .Degree of mitral regurgitation significantly reduced in group C ,no significant difference was found at the geometric angles of the mitral valve leaflets and mitral valve annular compared with group A .Conclusions The degree of mitral regurgitation were highly correlated with geometric angles of the mitral valve leaflets and mitral valve annular in patients with left ventricular papillary muscle dysfunction caused by coronary heart disease .Repair of the mitral valve leaflets surgery can significantly reduce geometric angles of the mitral valve leaflets and mitral valve annular ,and reduce the degree of mitral regurgitation significantly .

Result Analysis
Print
Save
E-mail