1.Thoracic Duct Embolization for Treatment of Chyle Leakage After Thyroidectomy and Neck Dissection
Sungmo MOON ; Juil PARK ; Gyoung Min KIM ; Kichang HAN ; Joon Ho KWON ; Man-Deuk KIM ; Jong Yun WON ; Hyung Cheol KIM
Korean Journal of Radiology 2024;25(1):55-61
Objective:
This study aimed to evaluate the safety and efficacy of intranodal lymphangiography and thoracic duct embolization (TDE) for chyle leakage (CL) after thyroid surgery.
Materials and Methods:
Fourteen patients who underwent intranodal lymphangiography and TDE for CL after thyroid surgery were included in this retrospective study. Among the 14 patients, 13 underwent bilateral total thyroidectomy with neck dissection (central compartment neck dissection [CCND], n = 13; left modified radical neck dissection (MRND), n = 11;bilateral MRND, n = 2), and one patient underwent left hemithyroidectomy with CCND. Ten patients (76.9%) had high-output CL (> 500 mL/d). Before the procedure, surgical intervention was attempted in three patients (thoracic duct ligation, n = 1;lymphatic leakage site ligation, n = 2). Lymphangiographic findings, technical and clinical successes, and complications were analyzed. Technical success was defined as the successful embolization of the thoracic duct after access to the lymphatic duct via the transabdominal route. Clinical success was defined as the resolution of CL or surgical drain removal.
Results:
On lymphangiography, ethiodized oil leakage near the surgical bed was identified in 12 of 14 patients (85.7%). The technical success rate of TDE was 78.6% (11/14). Transabdominal antegrade access was not feasible due to the inability to visualize the identifiable cisterna chyli or a prominent lumbar lymphatic duct. Among patients who underwent a technically successful TDE, the clinical success rate was 90.1% (10/11). The median time from the procedure to drain removal was 3 days (with a range of 1–13 days) for the 13 patients who underwent surgical drainage. No CL recurrence was observed during the follow-up period (ranging from 2–44 months; median, 8 months). There were no complications, except for one case of chylothorax that developed after TDE.
Conclusion
TDE appears to be a safe and effective minimally invasive treatment option for CL after thyroid surgery, with acceptable technical and clinical success rates.
2.Feasibility of Percutaneous Pancreatic Stent Placement in Postoperative Pancreaticojejunostomy Stenosis
Juil PARK ; Kichang HAN ; Joon Ho KWON ; Man-Deuk KIM ; Jong Yun WON ; Sungmo MOON ; Gyoung Min KIM
Korean Journal of Radiology 2023;24(12):1241-1248
Objective:
To evaluate the role of percutaneous pancreatic stent placement in postoperative pancreaticojejunostomy stenosis (PJS).
Materials and Methods:
This retrospective single-center study included seven procedures in five patients (four males and one female; median age, 63 years) who underwent percutaneous pancreatic stent placement for postoperative PJS between January 2005 and December 2021. The patients were referred to interventional radiology because of unfavorable anatomy or bowel abnormalities. The pancreatic duct was accessed under ultrasound and/or computed tomography guidance. A stent was placed after balloon dilatation of the PJS. Moreover, plastic stents were placed for the first two procedures, whereas bare-metal stents were used for the remaining five procedures. Technical success was defined as the successful placement of stents for the PJS, meanwhile, clinical success was defined as the normalization of pancreatic enzymes without recurrence of pancreatitis.
Results:
Pancreatic duct access and stent placement were successfully performed in all patients (technical success rate: 100%).All the procedures initially yielded clinical success. However, recurrence of pancreatitis was observed after two procedures that used plastic stents because of stent migration at 0.3 and 3 months after the procedure. In contrast, no instances of recurrent pancreatitis were noted after metal stent placement for a follow-up duration of 1–36 months. No serious procedure-related adverse events were observed.
Conclusion
Percutaneous pancreatic stent placement may be a viable option for patients with postoperative PJS in whom an endoscopic approach is not feasible. Metal stents may be considered over plastic stents for the management of PJS, considering the possible lower stent migration and infeasibility of frequent endoscopic stent exchange due to the altered anatomy.
3.Feasibility of Deep Learning-Based Analysis of Auscultation for Screening Significant Stenosis of Native Arteriovenous Fistula for Hemodialysis Requiring Angioplasty
Jae Hyon PARK ; Insun PARK ; Kichang HAN ; Jongjin YOON ; Yongsik SIM ; Soo Jin KIM ; Jong Yun WON ; Shina LEE ; Joon Ho KWON ; Sungmo MOON ; Gyoung Min KIM ; Man-deuk KIM
Korean Journal of Radiology 2022;23(10):949-958
Objective:
To investigate the feasibility of using a deep learning-based analysis of auscultation data to predict significant stenosis of arteriovenous fistulas (AVF) in patients undergoing hemodialysis requiring percutaneous transluminal angioplasty (PTA).
Materials and Methods:
Forty patients (24 male and 16 female; median age, 62.5 years) with dysfunctional native AVF were prospectively recruited. Digital sounds from the AVF shunt were recorded using a wireless electronic stethoscope before (pre-PTA) and after PTA (post-PTA), and the audio files were subsequently converted to mel spectrograms, which were used to construct various deep convolutional neural network (DCNN) models (DenseNet201, EfficientNetB5, and ResNet50). The performance of these models for diagnosing ≥ 50% AVF stenosis was assessed and compared. The ground truth for the presence of ≥ 50% AVF stenosis was obtained using digital subtraction angiography. Gradient-weighted class activation mapping (Grad-CAM) was used to produce visual explanations for DCNN model decisions.
Results:
Eighty audio files were obtained from the 40 recruited patients and pooled for the study. Mel spectrograms of “pre-PTA” shunt sounds showed patterns corresponding to abnormal high-pitched bruits with systolic accentuation observed in patients with stenotic AVF. The ResNet50 and EfficientNetB5 models yielded an area under the receiver operating characteristic curve of 0.99 and 0.98, respectively, at optimized epochs for predicting ≥ 50% AVF stenosis. However, GradCAM heatmaps revealed that only ResNet50 highlighted areas relevant to AVF stenosis in the mel spectrogram.
Conclusion
Mel spectrogram-based DCNN models, particularly ResNet50, successfully predicted the presence of significant AVF stenosis requiring PTA in this feasibility study and may potentially be used in AVF surveillance.
5.Laparoscopic pancreaticoduodenectomy with excision of aberrant right hepatic artery after preoperative segmental embolization in mid-bile duct cancer
Yoonwon KOOK ; Munseok CHOI ; Jung Yup PARK ; Ho Kyoung HWANG ; Woo Jung LEE ; Man-Deuk KIM ; Chang Moo KANG
Journal of Minimally Invasive Surgery 2021;24(2):104-108
Laparoscopic pancreaticoduodenectomy has proven to be a safe and effective alternative to open pancreati coduodenectomy with similar oncologic outcomes. Cases including excision of the hepatic artery with or without reconstruction during pancreaticoduodenectomy have been reported for periampullary cancer. Here we present a case of an 82-year-old patient who underwent laparoscopic pancreaticoduodenectomy following preoperative arterial embolization of an aberrant right hepatic artery arising from the superior mesenteric artery.
7.Laparoscopic pancreaticoduodenectomy with excision of aberrant right hepatic artery after preoperative segmental embolization in mid-bile duct cancer
Yoonwon KOOK ; Munseok CHOI ; Jung Yup PARK ; Ho Kyoung HWANG ; Woo Jung LEE ; Man-Deuk KIM ; Chang Moo KANG
Journal of Minimally Invasive Surgery 2021;24(2):104-108
Laparoscopic pancreaticoduodenectomy has proven to be a safe and effective alternative to open pancreati coduodenectomy with similar oncologic outcomes. Cases including excision of the hepatic artery with or without reconstruction during pancreaticoduodenectomy have been reported for periampullary cancer. Here we present a case of an 82-year-old patient who underwent laparoscopic pancreaticoduodenectomy following preoperative arterial embolization of an aberrant right hepatic artery arising from the superior mesenteric artery.
8.Uterine Artery Embolization for Leiomyomas and Adenomyosis: A Pictorial Essay Based on Our Experience from 1300 Cases
Korean Journal of Radiology 2019;20(10):1462-1473
Since its introduction in 1995, uterine artery embolization (UAE) has become an established option for the treatment of leiomyomas. Identification of a leiomyoma using arteriography improves the ability to perform effective UAE. UAE is not contraindicated in a pedunculated subserosal leiomyoma. UAE in a cervical leiomyoma remains a challenging procedure. A leiomyoma with high signal intensity on T2-weighted imaging responds well to UAE, but a malignancy with similar radiological features should not be misdiagnosed as a leiomyoma. Administration of gonadotropin-releasing hormone agonists before UAE is useful in selected patients and is not a contraindication for the procedure. The risk of subsequent re-intervention 5 years after UAE is approximately 10%, which represents an acceptable profile. UAE for adenomyosis is challenging; initial embolization using small particles can achieve better success than that by using larger particles. An intravenous injection of dexamethasone prior to UAE, followed by a patient-controlled analgesia pump and intra-arterial administration of lidocaine after the procedure, are useful techniques to control pain. Dexmedetomidine is an excellent supplemental sedative, showing a fentanyl-sparing effect without causing respiratory depression. UAE for symptomatic leiomyoma is safe and can be an alternative to surgery in most patients with a low risk of re-intervention.
Adenomyosis
;
Analgesia, Patient-Controlled
;
Angiography
;
Dexamethasone
;
Dexmedetomidine
;
Gonadotropin-Releasing Hormone
;
Humans
;
Injections, Intravenous
;
Leiomyoma
;
Lidocaine
;
Magnetic Resonance Imaging
;
Respiratory Insufficiency
;
Uterine Artery Embolization
;
Uterine Artery
;
Uterus
9.Mesocaval Shunt Creation for Jejunal Variceal Bleeding with Chronic Portal Vein Thrombosis
Ja Kyung YOON ; Man Deuk KIM ; Do Yun LEE ; Seok Joo HAN
Yonsei Medical Journal 2018;59(1):162-166
The creation of transjugular intrahepatic portosystemic shunt (TIPS) is a widely performed technique to relieve portal hypertension, and to manage recurrent variceal bleeding and refractory ascites in patients where medical and/or endoscopic treatments have failed. However, portosystemic shunt creation can be challenging in the presence of chronic portal vein occlusion. In this case report, we describe a minimally invasive endovascular mesocaval shunt creation with transsplenic approach for the management of recurrent variceal bleeding in a portal hypertension patient with intra- and extrahepatic portal vein occlusion.
Adolescent
;
Chronic Disease
;
Esophageal and Gastric Varices/complications
;
Esophageal and Gastric Varices/diagnostic imaging
;
Esophageal and Gastric Varices/therapy
;
Female
;
Gastrointestinal Hemorrhage/complications
;
Gastrointestinal Hemorrhage/diagnostic imaging
;
Gastrointestinal Hemorrhage/therapy
;
Humans
;
Jejunum/pathology
;
Portacaval Shunt, Surgical
;
Portal Vein/diagnostic imaging
;
Portal Vein/pathology
;
Portal Vein/surgery
;
Tomography, X-Ray Computed
;
Treatment Outcome
;
Venous Thrombosis/complications
;
Venous Thrombosis/diagnostic imaging
;
Venous Thrombosis/therapy
10.Angled Cool-Tip Electrode for Radiofrequency Ablation of Small Superficial Subcapsular Tumors in the Liver: A Feasibility Study.
Sung Il PARK ; Il Jung KIM ; Shin Jae LEE ; Min Woo SHIN ; Wonseon SHIN ; Yong Eun CHUNG ; Gyoung Min KIM ; Man Deuk KIM ; Jong Yun WON ; Do Yun LEE ; Jin Sub CHOI ; Kwang Hyub HAN
Korean Journal of Radiology 2016;17(5):742-749
OBJECTIVE: To evaluate the feasibility of angled cool-tip electrode for radiofrequency ablation of small superficial subcapsular liver tumors abutting abdominal wall, in order to traverse normal liver parenchyma, and thereby, obtain favorable configuration of ablation margin. MATERIALS AND METHODS: In this study, we retrospectively analyzed 15 small superficial subcapsular liver tumors abutting abdominal wall in 15 patients, treated with radiofrequency ablation from March 2013 to June 2015 using a cool-tip electrode manually modified to create 25-35° angle at the junction between exposed and insulated segments. The tumors were hepatocellular carcinoma (n = 13) and metastases (n = 2: cholangiocellular carcinoma and rectosigmoid cancer), with maximum diameter of 10-26 mm (mean, 15.68 ± 5.29 mm). Under ultrasonographic guidance, the electrode tip was advanced to the depth of the tumors' epicenter about 1 cm from the margin. The tip was re-directed to penetrate the tumor for radiofrequency ablation. Minimal ablation margin was measured at immediate post-treatment CT. Radiological images and medical records were evaluated for success rate, length of minimal ablation margin and complications. RESULTS: Technical success rate of obtaining complete necrosis of the tumors was 100%, with no procedure-related complication. Minimal ablation margin ranged from 3-12 mm (mean, 7.07 ± 2.23 mm). CT/MRI follow-up at 21-1022 days (mean, 519.47 ± 304.51 days) revealed no local recurrence, but distant recurrence in 9 patients. CONCLUSION: Using an angled cool-tip electrode for radiofrequency ablation of small superficial subcapsular tumors abutting abdominal wall may be a feasible technique for obtaining adequate ablation margin and lower complication rate.
Abdominal Wall
;
Carcinoma, Hepatocellular
;
Catheter Ablation*
;
Cholangiocarcinoma
;
Electrodes*
;
Feasibility Studies*
;
Follow-Up Studies
;
Humans
;
Liver*
;
Medical Records
;
Necrosis
;
Neoplasm Metastasis
;
Recurrence
;
Retrospective Studies

Result Analysis
Print
Save
E-mail