1.Next-Generation Patient-Based Real-Time Quality Control Models
Xincen DUAN ; Minglong ZHANG ; Yan LIU ; Wenbo ZHENG ; Chun Yee LIM ; Sollip KIM ; Tze Ping LOH ; Wei GUO ; Rui ZHOU ; Tony BADRICK ;
Annals of Laboratory Medicine 2024;44(5):385-391
Patient-based real-time QC (PBRTQC) uses patient-derived data to assess assay performance. PBRTQC algorithms have advanced in parallel with developments in computer science and the increased availability of more powerful computers. The uptake of Artificial Intelligence in PBRTQC has been rapid, with many stated advantages over conventional approaches. However, until this review, there has been no critical comparison of these. The PBRTQC algorithms based on moving averages, regression-adjusted real-time QC, neural networks and anomaly detection are described and contrasted. As Artificial Intelligence tools become more available to laboratories, user-friendly and computationally efficient, the major disadvantages, such as complexity and the need for high computing resources, are reduced and become attractive to implement in PBRTQC applications.
2.Next-Generation Patient-Based Real-Time Quality Control Models
Xincen DUAN ; Minglong ZHANG ; Yan LIU ; Wenbo ZHENG ; Chun Yee LIM ; Sollip KIM ; Tze Ping LOH ; Wei GUO ; Rui ZHOU ; Tony BADRICK ;
Annals of Laboratory Medicine 2024;44(5):385-391
Patient-based real-time QC (PBRTQC) uses patient-derived data to assess assay performance. PBRTQC algorithms have advanced in parallel with developments in computer science and the increased availability of more powerful computers. The uptake of Artificial Intelligence in PBRTQC has been rapid, with many stated advantages over conventional approaches. However, until this review, there has been no critical comparison of these. The PBRTQC algorithms based on moving averages, regression-adjusted real-time QC, neural networks and anomaly detection are described and contrasted. As Artificial Intelligence tools become more available to laboratories, user-friendly and computationally efficient, the major disadvantages, such as complexity and the need for high computing resources, are reduced and become attractive to implement in PBRTQC applications.
3.Next-Generation Patient-Based Real-Time Quality Control Models
Xincen DUAN ; Minglong ZHANG ; Yan LIU ; Wenbo ZHENG ; Chun Yee LIM ; Sollip KIM ; Tze Ping LOH ; Wei GUO ; Rui ZHOU ; Tony BADRICK ;
Annals of Laboratory Medicine 2024;44(5):385-391
Patient-based real-time QC (PBRTQC) uses patient-derived data to assess assay performance. PBRTQC algorithms have advanced in parallel with developments in computer science and the increased availability of more powerful computers. The uptake of Artificial Intelligence in PBRTQC has been rapid, with many stated advantages over conventional approaches. However, until this review, there has been no critical comparison of these. The PBRTQC algorithms based on moving averages, regression-adjusted real-time QC, neural networks and anomaly detection are described and contrasted. As Artificial Intelligence tools become more available to laboratories, user-friendly and computationally efficient, the major disadvantages, such as complexity and the need for high computing resources, are reduced and become attractive to implement in PBRTQC applications.
4.Next-Generation Patient-Based Real-Time Quality Control Models
Xincen DUAN ; Minglong ZHANG ; Yan LIU ; Wenbo ZHENG ; Chun Yee LIM ; Sollip KIM ; Tze Ping LOH ; Wei GUO ; Rui ZHOU ; Tony BADRICK ;
Annals of Laboratory Medicine 2024;44(5):385-391
Patient-based real-time QC (PBRTQC) uses patient-derived data to assess assay performance. PBRTQC algorithms have advanced in parallel with developments in computer science and the increased availability of more powerful computers. The uptake of Artificial Intelligence in PBRTQC has been rapid, with many stated advantages over conventional approaches. However, until this review, there has been no critical comparison of these. The PBRTQC algorithms based on moving averages, regression-adjusted real-time QC, neural networks and anomaly detection are described and contrasted. As Artificial Intelligence tools become more available to laboratories, user-friendly and computationally efficient, the major disadvantages, such as complexity and the need for high computing resources, are reduced and become attractive to implement in PBRTQC applications.
5.The LEAP Checklist for Laboratory Evaluation and Analytical Performance Characteristics Reporting of Clinical Measurement Procedures
Tze Ping LOH ; Brian R COOKE ; Thi Chi MAI TRAN ; Corey MARKUS ; Rosita ZAKARIA ; Chung Shun HO ; Elvar THEODORSSON ; Ronda F GREAVES ; Behalf of the IFCC Working Group on Method Evaluation Protocols (WG-MEP)
Annals of Laboratory Medicine 2024;44(2):122-125
Reporting a measurement procedure and its analytical performance following method evaluation in a peer-reviewed journal is an important means for clinical laboratory practitioners to share their findings. It also represents an important source of evidence base to help others make informed decisions about their practice. At present, there are significant variations in the information reported in laboratory medicine journal publications describing the analytical performance of measurement procedures. These variations also challenge authors, readers, reviewers, and editors in deciding the quality of a submitted manuscript. The International Federation of Clinical Chemistry and Laboratory Medicine Working Group on Method Evaluation Protocols (IFCC WG-MEP) developed a checklist and recommends its adoption to enable a consistent approach to reporting method evaluation and analytical performance characteristics of measurement procedures in laboratory medicine journals. It is envisioned that the Laboratory Evaluation and Analytical Performance Characteristics (LEAP) checklist will improve the standardisation of journal publications describing method evaluation and analytical performance characteristics, improving the quality of the evidence base that is relied upon by practitioners.
6.The Use of Bone-Turnover Markers in Asia-Pacific Populations
Samuel VASIKARAN ; Subashini C. THAMBIAH ; Rui Zhen TAN ; Tze Ping LOH ; APFCB Harmonization of Reference Interval Working Group
Annals of Laboratory Medicine 2024;44(2):126-134
Bone-turnover marker (BTM) measurements in the blood or urine reflect the bone-remodeling rate and may be useful for studying and clinically managing metabolic bone diseases.Substantial evidence supporting the diagnostic use of BTMs has accumulated in recent years, together with the publication of several guidelines. Most clinical trials and observational and reference-interval studies have been performed in the Northern Hemisphere and have mainly involved Caucasian populations. This review focuses on the available data for populations from the Asia-Pacific region and offers guidance for using BTMs as diagnostic biomarkers in these populations. The procollagen I N-terminal propeptide and β-isomerized C-terminal telopeptide of type-I collagen (measured in plasma) are reference BTMs used for investigating osteoporosis in clinical settings. Premenopausal reference intervals (established for use with Asia-Pacific populations) and reference change values and treatment targets (used to monitor osteoporosis treatment) help guide the management of osteoporosis. Measuring BTMs that are not affected by renal failure, such as the bone-specific isoenzyme alkaline phosphatase and tartrate-resistant acid phosphatase 5b, may be advantageous for patients with advanced chronic kidney disease. Further studies of the use of BTMs in individuals with metabolic bone disease, coupled with the harmonization of commercial assays to provide equivalent results, will further enhance their clinical applications.
7.Calibration Practices in Clinical Mass Spectrometry: Review and Recommendations
Wan Ling CHENG ; Corey MARKUS ; Chun Yee LIM ; Rui Zhen TAN ; Sunil Kumar SETHI ; Tze Ping LOH ;
Annals of Laboratory Medicine 2023;43(1):5-18
Background:
Calibration is a critical component for the reliability, accuracy, and precision of mass spectrometry measurements. Optimal practice in the construction, evaluation, and implementation of a new calibration curve is often underappreciated. This systematic review examined how calibration practices are applied to liquid chromatography-tandem mass spectrometry measurement procedures.
Methods:
The electronic database PubMed was searched from the date of database inception to April 1, 2022. The search terms used were “calibration,” “mass spectrometry,” and “regression.” Twenty-one articles were identified and included in this review, following evaluation of the titles, abstracts, full text, and reference lists of the search results.
Results:
The use of matrix-matched calibrators and stable isotope-labeled internal standards helps to mitigate the impact of matrix effects. A higher number of calibration standards or replicate measurements improves the mapping of the detector response and hence the accuracy and precision of the regression model. Constructing a calibration curve with each analytical batch recharacterizes the instrument detector but does not reduce the actual variability. The analytical response and measurand concentrations should be considered when constructing a calibration curve, along with subsequent use of quality controls to confirm assay performance. It is important to assess the linearity of the calibration curve by using actual experimental data and appropriate statistics. The heteroscedasticity of the calibration data should be investigated, and appropriate weighting should be applied during regression modeling.
Conclusions
This review provides an outline and guidance for optimal calibration practices in clinical mass spectrometry laboratories.
8.Functional Reference Limits: Describing Physiological Relationships and Determination of Physiological Limits for Enhanced Interpretation of Laboratory Results
Tyng Yu CHUAH ; Chun Yee LIM ; Rui Zhen TAN ; Busadee PRATUMVINIT ; Tze Ping LOH ; Samuel VASIKARAN ; Corey MARKUS ;
Annals of Laboratory Medicine 2023;43(5):408-417
Functional reference limits describe key changes in the physiological relationship between a pair of physiologically related components. Statistically, this can be represented by a significant change in the curvature of a mathematical function or curve (e.g., an observed plateau). The point at which the statistical relationship changes significantly is the point of curvature inflection and can be mathematically modeled from the relationship between the interrelated biomarkers. Conceptually, they reside between reference intervals, which describe the statistical boundaries of a single biomarker within the reference population, and clinical decision limits that are often linked to the risk of morbidity or mortality and set as thresholds. Functional reference limits provide important physiological and pathophysiological insights that can aid laboratory result interpretation. Laboratory professionals are in a unique position to harness data from laboratory information systems to derive clinically relevant values. Increasing research on and reporting of functional reference limits in the literature will enhance their contribution to laboratory medicine and widen the evidence base used in clinical decision limits, which are currently almost exclusively contributed to by clinical trials. Their inclusion in laboratory reports will enhance the intellectual value of laboratory professionals in clinical care beyond the statistical boundaries of a healthy reference population and pave the way to them being considered in shaping clinical decision limits. This review provides an overview of the concepts related to functional reference limits, clinical examples of their use, and the impetus to include them in laboratory reports.
9.Calcium, Vitamin D, and Bone Derangement in Nephrotic Syndrome
Samantha Peiling Yang ; Lizhen Ong ; Tze Ping Loh ; Horng Ruey Chua ; Cassandra Tham ; Khoo Chin Meng ; Lim Pin
Journal of the ASEAN Federation of Endocrine Societies 2021;36(1):50-55
Introduction:
Derangement in calcium homeostasis is common in nephrotic syndrome (NS). It is postulated that low serum total calcium and vitamin D levels are due to loss of protein-bound calcium and vitamin D. It is unclear if free calcium and free vitamin D levels are truly low. The guideline is lacking with regards to calcium and vitamin D supplementation in NS. This study aims to examine calcium and vitamin D homeostasis and bone turnover in NS to guide practice in calcium and vitamin D levels supplementation.
Methodology:
This is a prospective pilot study of ten patients diagnosed with NS, and eight healthy controls. Calcium, vitamin D, and bone turnover-related analytes were assessed at baseline, partial and complete remission in NS patients and in healthy controls.
Results:
NS patients had low free and total serum calcium, low total 25(OH)D, normal total 1,25(OH)D levels and lack of parathyroid hormone response. With remission of disease, serum calcium and vitamin D metabolites improved. However, nephrotic patients who do not attain complete disease remission continue to have low 25(OH)D level.
Conclusion
In this study, the vitamin D and calcium derangement observed at nephrotic syndrome presentation trended towards normalisation in remission. This suggested calcium and vitamin D replacement may not be indicated in early-phase nephrotic syndrome but may be considered in prolonged nephrotic syndrome.
Vitamin D Deficiency
10.Hemoglobin A1c Levels Are Slightly but Significantly Lower in Normoglycemic Subjects With the Hemoglobin E Phenotype
Busadee PRATUMVINIT ; Kanit REESUKUMAL ; Sithikan HANYONGYUTH ; Sujitra WANGCHAIJAROENKIT ; Julaporn POOLIAM ; Gerald J KOST ; Panumas KAMKANG ; Tze Ping LOH
Annals of Laboratory Medicine 2019;39(2):209-213
Hb mutations can alter the structure, behavior, stability, or quantity of the globin chain produced. Some Hb variants shorten the erythrocyte life span, resulting in physiologically lower hemoglobin A1c (HbA1c) levels. The hemoglobin E (HbE) phenotype involves a single-nucleotide polymorphism that reduces β-globin chain synthesis. We compared the HbA1c levels of subjects with normal Hb (HbAA; N=131) and HbE (N=148) phenotypes, examining potential hematological and biochemical factors contributing to differences in HbA1c levels. All had normal fasting plasma glucose ( < 5.6 mmol/L), AST, ALT, and creatinine levels. Mean±SD HbA1c levels differed between HbAA and HbE subjects: 5.5±0.3% and 5.3±0.3% (P < 0.001) according to an immunoassay, and 5.5±0.3% and 5.3±0.3% (P < 0.001) according to cation-exchange HPLC, respectively. In multiple logistic regression, only mean corpuscular volume (P < 0.001) contributed to the difference in HbA1c levels between groups. Although a 0.2% difference in HbA1c is relatively small and unlikely to alter clinical decisions, epidemiologically, this can lead to misclassification of a significant proportion of the population, especially since the threshold of non-diabetes HbA1c (≤5.6%) falls very close to the HbA1c median of the general population.
Accidental Falls
;
Blood Glucose
;
Chromatography, High Pressure Liquid
;
Creatinine
;
Erythrocyte Indices
;
Erythrocytes
;
Fasting
;
Globins
;
Hemoglobin E
;
Hemoglobins
;
Immunoassay
;
Logistic Models
;
Phenotype


Result Analysis
Print
Save
E-mail