1.Identification of core genes of osteoarthritis by bioinformatics
Xuekun ZHU ; Heng LIU ; Hui FENG ; Yunlong GAO ; Lei WEN ; Xiaosong CAI ; Ben ZHAO ; Min ZHONG
Chinese Journal of Tissue Engineering Research 2025;29(3):637-644
BACKGROUND:At present,osteoarthritis has become a major disease affecting the quality of life of the elderly,and the therapeutic effect is poor,often focusing on preventing the disease process,and the pathogenesis of osteoarthritis is still not fully understood.Bioinformatics analysis was carried out to explore the main pathogenesis of osteoarthritis and related mechanisms of gene coding regulation. OBJECTIVE:To screen core differential genes with a major role in osteoarthritis by gene expression profiling. METHODS:Datasets were downloaded from the Gene Expression Omnibus(GEO):GSE114007,GSE117999,and GSE129147.Differential genes in the GSE114007 and GSE117999 data collections were screened using R software,performing differential genes to weighted gene co-expression network analysis.The module genes most relevant to osteoarthritis were selected to perform protein interaction analysis.Candidate core genes were selected using the cytocape software.The candidate core genes were subsequently subjected to least absolute shrinkage and selection operator regression and COX analysis to identify the core genes with a key role in osteoarthritis.The accuracy of the core genes was validated using an external dataset,GSE129147. RESULTS AND CONCLUSION:(1)A total of 477 differential genes were identified,265 differential genes associated with osteoarthritis were obtained by weighted gene co-expression network analysis,and 8 candidate core genes were identified.The least absolute shrinkage and selection operator regression analysis finally yielded a differential gene ASPM with core value that was externally validated.(2)It is concluded that abnormal gene ASPM expression screened by bioinformatics plays a key central role in osteoarthritis.
2.Analysis of red blood cell transfusion reactions in China from 2018 to 2023
Bo PAN ; Xiaoyu GUAN ; Jue WANG ; Yunlong PAN ; Liu HE ; Haixia XU ; Xin JI ; Li TIAN ; Ling LI ; Zhong LIU
Chinese Journal of Blood Transfusion 2025;38(5):704-710
Objective: To analyze the demographic characteristics of patients with red blood cell transfusion reactions, the usage of red blood cell preparations, and the differences in the composition ratio of adverse reactions based on multi-center data from the Haemovigilance Network, in order to reveal the clinical characteristics of red blood cell transfusion and its underlying issues. Methods: Clinical data of patients who experienced transfusion reactions after red blood cell transfusion in the Haemovigilance Network from 2018 to 2023 were collected. The demographic characteristics of patients who experienced transfusion reactions with different types of red blood cell preparations, the utilization of these preparations, and the differences of the composition ratios of transfusion reactions were analyzed. Count data were expressed as numbers (n) or percentages (%), and comparisons between groups were performed using the Chi-square test. Results: Red blood cell transfusion reactions were more common in females (53.56%), with the majority of patients aged 50-69 years (35.54%). The Han polulation accounted for the vast majority of patients (92.77%), and patients in the hematology and obstetrics/gynecology departments had a relatively high proportion of transfusion reactions (13.26% and 14.26%, respectively). Leukocyte-reduced red blood cells and suspended red blood cells were the most common types of transfusion reactions reported among red blood cell preparations. Allergic reactions and non-hemolytic febrile reactions were the most common transfusion reactions, and there were significant differences in the composition ratios of allergic reactions (χ
=869.89, P<0.05) and non-hemolytic febrile reactions (χ
=812.75, P<0.05) across various types of red blood cell preparations. Conclusion: There are differences in the demographic characteristics and composition ratio of transfusion reactions among different red blood cell preparations. The management of red blood cell transfusion reactions should be tailored to patient characteristics and conditions, and the selection and use of blood products should be optimized to reduce or avoid the occurrence of transfusion reactions, such as considering the use of washed red blood cells for patients with a history of transfusion allergies or those prone to allergies.
3.Preparation of HA-modified emodin-contained multi-walled carbon nanotubes drug delivery system and its inhi-bitory effect on breast cancer cells
Yuduo LI ; Juan DU ; Yunlong LIU ; Feng GENG ; Xiaobing CHEN
China Pharmacy 2025;36(12):1463-1469
OBJECTIVE To prepare hyaluronic acid (HA)-modified emodin (EMD)-contained multi-walled carbon nanotubes (MWCNTs) drug delivery system (HA-MWCNTs-EMD) and explore its in vitro inhibitory effect on breast cancer cells. METHODS EMD was loaded onto MWCNTs to prepare a drug delivery system MWCNTs-EMD; subsequently, the system was further modified with HA to obtain the drug delivery system HA-MWCNTs-EMD. The two drug delivery systems mentioned above were characterized. With free EMD as the reference, the drug release in vitro of the above two drug delivery systems was investigated; the uptake of EMD by two breast cancer cells (MCF-7, MDA-MB-231 cells) was detected. The impacts of the above two drug delivery systems on the expression of surface glycoprotein differentiation group 44 (CD44), activity, apoptosis and lactate dehydrogenase (LDH) release of two breast cancer cells were detected. RESULTS The encapsulation efficiencies of MWCNTs-EMD and HA-MWCNTs-EMD were both (63.52±2.74)%, with drug loading rates of (25.01±1.83)% and (12.13± 1.96)%, particle sizes of (865.95±2.16) and (351.86±1.68) nm, polydispersity indexes of 0.54±0.02 and 0.23±0.01, and Zeta potentials of (23.87±0.14) and (-42.79±0.39) mV, respectively. The 2, 4, 6, 8, 10, 12 and 24-hour cumulative release rates of EMD in MWCNTs-EMD and HA-MWCNTs-EMD were significantly lower than those in free EMD, while the cumulative release rate of HA-MWCNTs-EMD was significantly higher than that of MWCNTs-EMD (P<0.05); the EMD uptakes of MWCNTs-EMD and HA-MWCNTs-EMD by the two types of breast cancer cells were significantly higher than their uptake of free EMD (P<0.05). Compared with the free EMD group, the MWCNTs-EMD and MWCNTs-EMD groups showed significantly higher apoptosis rate and LDH release, significantly lower surface CD44 expression (except for the MWCNTs-EMD group) and cell viability in both cell types, and the effect of HA-MWCNTs-EMD was more pronounced (P<0.05). CONCLUSIONS A novel drug delivery system HA-MWCNTs- EMD loaded with EMD is developed successfully; the drug delivery system has a certain slow-release effect, which can significantly reduce the activity of breast cancer cells, promote their apoptosis and increase the release of LDH, and the above anti- breast cancer effect is significantly stronger than that of free EMD and MWCNTs-EMD.
4.A modified surgical technique of robot-assisted inferior vena cava thrombectomy for patients with left renal cell carcinoma and tumor emboli: a report of 7 cases eliminating preoperative interventional embolization
Shengzheng WANG ; Jinshan CUI ; Zhenhao LI ; Yunlong LIU ; Shuanbao YU ; Yafeng FAN ; Zhaowei ZHU ; Jin TAO ; Xuepei ZHANG
Journal of Modern Urology 2025;30(2):128-132
Objective: To explore the safety and feasibility of the disconnection of the left renal artery preferentially during robot-assisted inferior vena cava (IVC) thrombectomy for patients with left renal cell carcinoma and tumor emboli. Methods: Clinical data of 7 patients who underwent robot-assisted IVC thrombectomy and radical nephrectomy in the First Affiliated Hospital of Zhengzhou University during Dec.2021 and Oct.2024 were retrospectively analyzed.Thrombectomy was performed first,followed by nephrectomy. The “IVC-first, kidney-last”robotic technique was developed to minimize chances of IVC thrombus. When patients in left lateral decubitus position, the left renal artery was severed from the right side through the inferior vena cava and abdominal aorta. After removal of thrombus from IVC was completed, patients changed to the right lateral position to complete radical left nephrectomy. Results: Imaging examinations revealed that the median diameter of the renal cell carcinomas was 83(46-99) mm; the median length of the inferior vena cava cancerous emboli was 49(2-91) mm.According to the Mayo classification,the cancerous emboli were gradeⅠ in 2 cases,gradeⅡ in 4 cases,and grade Ⅲ in 1 case.All surgeries were successful.The median operation time was 248(201-331) minutes,blood loss 500(200-1000) mL,and 6 cases required intraoperative blood transfusion.The median time for transition into the intensive care unit was 1(1-4) days,and drainage tube removal 6(5-12) days.Serum creatinine increased significantly in 5 cases,4 of which returned to normal after 1 week,but 1 had renal insufficiency (creatinine 166 μmol/L).Chylous fistula occurred in 1 patient,and lower extremity venous thrombosis developed in 3 patients.Pathological examinations indicated 6 cases of renal cell carcinoma and 1 case of MiT family translocation renal cell carcinoma.During the median follow-up of 17(1-35) months,5 cases were tumor-free,while 2 had lung and retroperitoneal metastases.They received targeted therapy of axitinib combined immunotheraphy and lived with tumors. Conclusion: In the left lateral position for left renal cell carcinoma with cancerous emboli,robot-assisted laparoscopic thrombectomy by crossing the inferior vena cava and abdominal aorta and disconnecting the left renal artery first is safe and feasible.
5.Research progress on mesenchymal stem cell products and their exosomes in the treatment of inflammatory bowel disease
Jingwen YANG ; Qian CHEN ; Yunlong SHAN ; Jiali LIU ; Ning WEI ; Jing WANG ; Guangji WANG ; Fang ZHOU
Journal of China Pharmaceutical University 2024;55(1):103-114
Abstract: Inflammatory bowel disease (IBD), whose pathogenesis remains elusive, is a group of autoimmune diseases characterized by chronic, progressive, and lifelong inflammation of the digestive tract. The pathogenesis of IBD remains elusive. Although a number of drugs have been developed to treat IBD, their effects are merely anti-inflammatory. In addition, current treatments for IBD are easily susceptible to resistance in clinical practice. Mesenchymal stem cells (MSCs) have been reported to have the ability to migrate to the site of inflammation, with potent immunoregulatory effects, and to rebalance the immune microenvironment and restore the integrity of the epithelial barrier with significant value of application, particularly for patients who are refractory to classic medicines. In this paper, we reviewed the clinical applications, mechanisms and engineerable properties of MSC products and their exosomes to provide some reference for the use of MSCs and their exosomes in the treatment of IBD.
6.Zinc deficiency during pregnancy and its effect on pregnancy outcome
Yunlong LI ; Rui LI ; Yuping ZHANG ; Rui WANG ; Yanping LIU
Basic & Clinical Medicine 2024;44(4):422-427
Zinc deficiency during pregnancy is common and has been significantly associated with adverse pregnancy outcomes such as spontaneous preterm birth(PTB),recurrent abortion(RA),low birth weight(LBW),small-for-gestational-age infant(SGA),preeclampsia(PE),and gestational diabetes mellitus(GDM).Unfortunately,there is no specific biomarkers which are sensitive,easy-to-collect and detect available for the clini-cal evaluation of zinc nutritional status.However,recent studies have identified metallothionein and the ratio of oleic acid to dihydroxymethyl gamma-linolenic acid(LA/DGLA)as potentially candidates of biomarkers.This article focuses on summarizing and discussing the progress of domestic and international researches on zinc deficiency dur-ing pregnancy and adverse pregnancy outcomes,potential zinc biomarkers,and zinc deficiency treatments,aiming at providing ideas for perinatal nutritional guidance.
7.Research progress of strontium and pregnancy and pregnancy diseases
Rui WANG ; Rui LI ; Yunlong LI ; Yuping ZHANG ; Kang YU ; Yanping LIU
Basic & Clinical Medicine 2024;44(4):428-433
Strontium(Sr)is a trace element naturally found in the human skeletal system.In recent years,the po-tential impact of strontium on bone and cardiovascular health has called significant attention,particularly during pregnancy,when alterations in mineral metabolism may affect the health of both the mother and the fetus.This com-prehensive review assesses the current understanding of the role of strontium as a nutritional substance during preg-nancy,its effects on maternal health and fetal development,and its potential associations with pregnancy complica-tions such as preeclampsia,gestational hypertension,and lactation-induced osteoporosis.The review also summarizes the possible effects of strontium deficiency,excess,and supplementation,and provides information for developing prenatal nutrition supplementation guideline.
8.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
9.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
10.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.

Result Analysis
Print
Save
E-mail