1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6. Characterization of group Ⅰ metabotropic glutamate receptors in rat superior cervical ganglion and their changes following chronic intermittent hypoxia
Xi-Xi WEI ; Chao-Hong LI ; Chen-Lu ZHAO ; Jia-Ping TANG ; Yu-Zhen LIU ; Xi-Xi WEI ; Chao-Hong LI ; Chen-Lu ZHAO ; Jia-Ping TANG ; Yu-Zhen LIU
Acta Anatomica Sinica 2024;55(1):3-9
Objective To observe the expression and localization of group Ⅰ metabotropic glutamate receptors (mGluR1/ 5) in rat superior cervical ganglion (SCG) and the effect of chronic intermittent hypoxia (CIH) on mGluR1/ 5 protein level. Methods Twelve male SD rats were randomly divided into control group(Ctrl)and CIH group(CIH), 6 rats in each group. After 6 weeks of modeling, the effect of CIH on mGluR1/ 5 protein level was detected by Western blotting, the expression and distribution of mGluR1/ 5 in SCG were detected by immunohistochemistry and double-immunofluorescent staining. Results mGluR1/ 5 was expressed in rat SCG. mGluR1 was distributed in neurons and small intensely fluorescent (SIF) cells, but not in satellite glial cells (SGCs), nerve fibers and blood vessels, whereas mGluR5 was mainly distributed in nerve fibers and a little in neurons, but not in SGCs, SIF cells and blood vessels. CIH increased the protein levels of mGluR1/ 5 (P<0. 01) in rat SCG. Conclusion Both mGluR1 and mGluR5 are expressed in the rat SCG, but their distribution are different, and the increased protein levels of both may be involved in CIH-induced hypertension.
7.Impact of positive preoperative E.coli infection on surgical site infection and postoperative fever after urethral strictoplasty
Hao PAN ; Yu LIU ; Xi JIN ; Hong LI ; Kunjie WANG
Journal of Army Medical University 2024;46(3):277-282
Objective To investigate whether E.coli infection increases surgical site infection and postoperative fever in comparison with other pathogens.Methods A retrospective cohort study was conducted on 506 patients who underwent urethral segment resection and end anastomosis for the bulb or posterior urethral stenosis in our department during 2011 and 2019.According to occurrence of postoperative surgical site infection(SSI)or postoperative fever(POF),they were divided into SSI group(n=19)and non-SSI group(n=487),as well as POF group(n=61)and non-POF group(n=445 patients)respectively.Multivariate logistic regression analysis and LASSO algorithm were used to screen the potential risk factors.According to the results of positive preoperative urine culture in 302 patients,they were subsequently divided into E.coli infection group(n=80)and other pathogen infection group(n=222),and after reducing potential bias with propensity score matching,finally 48 patients were assigned into E.coli infection group,and 192 into other pathogen infection groups.The differences in occurrences of SSI and POF were compared between the above 2 groups of patients.Results Multivariate logistic regression analysis and LASSO algorithm revealed that positive preoperative urine culture was an independent risk factor for predicting SSI(P=0.012)and POF(P<0.01).Among the 302 patients with positive results in preoperative urine culture,E.coli infections was in the first rank,accounting for 26.5%.After propensity score matched treatment,the incidence of SSI in the E.coli group and other pathogen groups was 29.2%and 2.1%,respectively(P<0.01).The incidence of POF was also higher in the E.coli infection group than the other pathogen infection group(27.1%vs 13.5%,P=0.02).Conclusion Preoperative E.coli infection may increase the risk of SSI and POF after urethroplasty when compared with other pathogen infections.
8.Effects of dexmedetomidine in perioperative period on pain, oxidative stress and adverse reactions after radical breast cancer surgery
Hong LI ; Jianjian LIU ; Shumin WEI ; Mujiao XI ; Fazhan ZHANG ; Shoukai ZONG ; Nana CHI ; Qingxiang CAO
Chinese Journal of Endocrine Surgery 2024;18(1):104-108
Objective:To explore the effects of dexmedetomidine (DEX) on postoperative pain, oxidative stress and adverse reactions in patients undergoing radical mastectomy.Methods:A total of 90 patients with breast cancer who received radical surgical treatment in our hospital from Jun. 2022 to Jun. 2023 were prospectively included as research objects and randomly divided into 3 groups with 30 patients in each group. DEX group was applied before, during and after surgery, respectively. The levels of pain visual analogue scale (VAS), Richmonation sedation score (RASS), superoxide dismu-tase (SOD) and malondialdehyde (MDA) were recorded.Results:The recovery time and extubation time in preoperative and intraoperative DEX group were significantly lower than those in postoperative DEX group, and the awakening time and extubation time in preoperative DEX group were significantly lower than those in intraoperative DEX group ( F value was 48.62 and 53.98, respectively, P<0.001). At 1 h, 6 h and 12 h after surgery, the VAS and RASS scores of patients in the preoperative and intraoperative DEX group were significantly lower than those in the postoperative DEX group, compared with those in the intraoperative DEX group. The VAS and RASS scores in the DEX group were significantly decreased ( F value: 62.34, 55.24, 69.26, 36.82, 24.20, 39.97, P<0.001). At 24h after surgery, there was no significant difference in VAS and RASS scores among the three groups ( F value was 0.45 and 0.81, respectively, P value was 0.613 and 0.418). Immediately after surgery, 24 h after surgery, 72 h after surgery, the SOD level of DEX group was significantly higher than that of DEX group before and during surgery ( F value was 29.37, 33.24, 10.35, P<0.001). MDA levels were significantly lower than those in postoperative DEX group ( F value was 30.52, 41.27, 8.26, P<0.001). There was no significant difference in the incidence of postoperative adverse reactions among all groups ( P>0.05) . Conclusion:Preoperative and intraoperative application of DEX can reduce postoperative pain and oxidative stress in breast cancer patients, help patients recover quickly after surgery, and preoperative application is superior to intraoperative application.
9.Research progress on the mechanism of several common sedatives and analgesics on cardiovascular pro-tection in patients with ischemic heart disease
Chinese Journal of cardiovascular Rehabilitation Medicine 2024;33(1):97-100
Currently,living standard of people keeps growing,however,living habit changes follow economic development.Poor diet makes incidence rate of cardiovascular diseases increase year by year.Number of patients suffering from ischemic heart disease remains high in China every year,its characteristics of sudden onset,rapidly changing condition and high mor-tality bring huge shock on many families.The development of modern medicine has greatly reduced the risk of surgery for patients with ischemic heart disease(IHD).However,it is still necessary to master and understand the effects of sedatives and analgesics on cardiovascular system in order to perform successful completion of surgery on the premise of patient safe-ty.Propofol,sevoflurane,sufentanil,remifentanil and dexmedetomidine are commonly used sedatives and analgesics.The present article makes a review on the mechanism of above drugs on cardiovascular protection.
10.Study on The Mechanism of Sinomenine Hydrochloride Induced Fibroblast Apoptosis in Rabbits with Adhesive Knee Ankylosis
Xin-Ju HOU ; Hong-Feng LEI ; Yong CHEN ; Fu-Xi LI ; Jing-Ning SUN ; Jia-Ming LIU ; Hong-Mei MA
Progress in Biochemistry and Biophysics 2024;51(4):959-968
ObjectiveThis study aimed to observe the impact of sinomenine hydrochloride on the proliferation of fibroblasts and the mRNA expression of related genes in knee joint adhesion and contracture in rabbits. Additionally, we sought to explore its potential mechanisms in combating knee joint adhesion and contracture. MethodsFibroblasts were cultured in vitro, and experimental groups with varying concentrations of sinomenine hydrochloride were established alongside a control group. Cell proliferation was assessed using the CCK-8 assay. Changes in the mRNA expression of fibroblast-related genes following sinomenine hydrochloride treatment were evaluated using RT-qPCR. The impact of the drug on serum levels of inflammatory cytokines was determined using the ELISA method, and the expression of related proteins was assessed using Western blot. ResultsSinomenine hydrochloride was found to inhibit fibroblast viability, with viability decreasing as the concentration of sinomenine hydrochloride increased. The effects of sinomenine hydrochloride in all experimental groups were highly significant (P<0.05). At the mRNA expression level, compared to the control group, sinomenine hydrochloride led to a significant downregulation of inflammatory cytokines in all groups (P<0.05). Additionally, the expression levels of apoptosis-related proteins significantly increased, while Bcl-2 mRNA expression decreased (P<0.05). The mRNA expression levels of the PI3K/mTOR/AKT3 signaling pathway also decreased (P<0.05). At the protein expression level, in comparison to the control group, the levels of inflammatory cytokines IL-6, IL-8, IL-1β, and TGF-β were significantly downregulated in the middle and high-dose sinomenine hydrochloride groups (P<0.05). The expression levels of cleaved-PARP, cleaved caspase-3/7, and Bax increased and were positively correlated with the dose, while the expression levels of the anti-apoptotic protein Bcl-2 and the PI3K/AKT3/mTOR signaling pathway were negatively correlated with the dose. Sinomenine hydrochloride exhibited a significant inhibitory effect on the viability of rabbit knee joint fibroblasts, which may be associated with the downregulation of inflammatory cytokines IL-6, IL-8, and IL-1β, promotion of apoptosis-related proteins cleaved-PARP, cleaved caspase-3/7, and Bax, suppression of Bcl-2 expression, and inhibition of gene expression in the downstream PI3K/AKT3/mTOR signaling pathway. ConclusionSinomenine hydrochloride can inhibit the inflammatory response of fibroblasts in adhesive knee joints and accelerate fibroblast apoptosis. This mechanism may offer a novel approach to improving and treating knee joint adhesion.

Result Analysis
Print
Save
E-mail