1.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
2.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
3.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
4.Quality evaluation for Beidougen Formula Granules
Gui-Yun CAO ; Xue-Song ZHUANG ; Bo NING ; Yong-Qiang LIN ; Dai-Jie WANG ; Wei-Liang CUI ; Hong-Chao LIU ; Xiao-Di DONG ; Meng-Meng HUANG ; Zhao-Qing MENG
Chinese Traditional Patent Medicine 2024;46(3):717-723
AIM To evaluate the quality of Beidougen Formula Granules.METHODS Fifteen batches of standard decoctions and three batches of formula granules were prepared,after which paste rate and contents,transfer rates of magnoflorine,daurisoline,dauricine were determined.HPLC specific chromatograms were established,and cluster analysis was adopted in chemical pattern recognition.RESULTS For three batches of formula granules,the paste rates were 15.1%-16.6%,the contents of magnoflorine,daurisoline,dauricine were 18.93-19.39,9.42-9.60,6.79-6.85 mg/g with the transfer rates of 34.42%-35.25%,43.81%-44.65%,27.27%-27.51%from decoction pieces to formula granules,respectively,and there were seven characteristic peaks in the specific chromatograms with the similarities of more than 0.95,which demonstrated good consistence with those of standard decoctions and accorded with related limit requirements.Fifteen batches of standard decoctions were clustered into two types,and the medicinal materials produced from Jilin,Hebei,Shangdong could be used for the preparation of formula granules.CONCLUSION This reasonable and reliable method can provide references for the quality control and clinical application of Beidougen Formula Granules.
5.A phase Ⅱ clinical study of the efficacy and safety of antaitasvir phosphate combined with yiqibuvir for the treatment of chronic hepatitis C in adults
Lai WEI ; Hongxin PIAO ; Jinglan JIN ; Shufen YUAN ; Xuan AN ; Jia SHANG ; Wenhua ZHANG ; Jiabao CHANG ; Tong SUN ; Yujuan GUAN ; Bo NING ; Jing ZHU ; Wentao GUO ; Qingwei HE ; Lin LUO ; Yulei ZHUANG ; Hongming XIE ; Yingjun ZHANG
Chinese Journal of Hepatology 2024;32(7):637-642
Objective:To evaluate the efficacy and safety of antaitasvir phosphate 100 mg or 200 mg combined with yiqibuvir for 12 weeks in patients with various genotypes of chronic hepatitis C, without cirrhosis or compensated stage cirrhosis.Methods:Patients with chronic hepatitis C (without cirrhosis or compensated stage cirrhosis) were randomly assigned to the antaitasvir phosphate 100 mg+yiqibuvir 600 mg group (100 mg group) or the antaitasvir phosphate 200 mg+yiqibuvir 600 mg group (200 mg group) in a 1∶1 ratio. The drugs were continuously administered once a day for 12 weeks and observed for 24 weeks after drug withdrawal. The drug safety profile was assessed concurrently with the observation of the sustained virological response (SVR12) in the two patient groups 12 weeks following the drug cessation. The intention-to-treat concept was used to define as closely as possible a full analysis set, including all randomized cases who received the experimental drug at least once. The safety set was collected from all subjects who received the experimental drug at least once (regardless of whether they participated in the randomization group) in this study. All efficacy endpoints and safety profile data were summarized using descriptive statistics. The primary efficacy endpoint was SVR12. The primary analysis was performed on a full analysis set. The frequency and proportion of cases were calculated in the experimental drug group (antaitasvir phosphate capsules combined with yiqibuvir tablets) that achieved "HCV RNA
6.Analysis on Quality Standard of Fraxini Cortex(Fraxinus chinensis) Dispensing Granules Based on Standard Decoction
Guiyun CAO ; Bo NING ; Jinmiao QIN ; Xuesong ZHUANG ; Daijie WANG ; Yongqiang LIN ; Xiaodi DONG ; Yi LUO ; Zhaoqing MENG
Chinese Journal of Experimental Traditional Medical Formulae 2023;29(13):122-129
ObjectiveTo establish the quality standard for Fraxini Cortex(Fraxinus chinensis) dispensing granules based on standard decoction, and to provide a basis for the quality control of this dispensing granules. MethodHigh performance liquid chromatography(HPLC) specific chromatograms of 15 batches of Fraxini Cortex(F. chinensis) standard decoctions and 3 batches of Fraxini Cortex(F. chinensis) dispensing granules were established with the mobile phase of 0.1% phosphoric acid aqueous solution(A)-acetonitrile(B) for gradient elution(0-10 min, 12%-15%B; 10-30 min, 15%-32%B) and the detection wavelength of 220 nm. And similarity evaluation, cluster analysis and principal component analysis(PCA) were also carried out. HPLC quantitative analysis of multi-components by single marker(QAMS) was established to determine the contents of the main components in the standard decoctions and dispensing granules. The contents of the corresponding components in Fraxini Cortex(F. chinensis) decoction pieces were also detected, and the transfer rates from decoction pieces to standard decoctions and dispensing granules were calculated. ResultThe similarities between specific chromatograms of 15 batches of Fraxini Cortex(F. chinensis) standard decoctions and 3 batches of Fraxini Cortex(F. chinensis) dispensing granules were all>0.9, and 7 common peaks were identified. The results of cluster analysis and PCA showed that there was some differences in the composition of different batches of standard decoctions, but did not show aggregation of origin. As the standard decoctions, the extract rate was 6.18%-11.62%, the contents of esculin, syringin, fraxin, esculetin, fraxetin, calceolarioside B were 44.92-103.51, 1.36-11.87, 33.26-90.73, 4.63-29.75, 2.40-16.86, 2.49-17.35 mg·g-1, and the transfer rates from decoction pieces to standard decoction were 25.21%-42.54%, 52.57%-88.84%, 43.43%-79.45%, 49.15%-88.27%, 49.22%-72.69%, 27.66%-47.67%, respectively. The extract rates of Fraxini Cortex(F. chinensis) dispensing granules were 10.4%-10.7%, the transfer rates of the above six components from decoction pieces to dispensing granules were 42.76%-43.17%, 80.01%-80.90%, 59.59%-59.88%, 51.35%-52.67%, 60.50%-60.93%, 37.98%-38.37%, respectively, which were generally consistent with the transfer rates from decoction pieces to standard decoctions. ConclusionThe established quality control standard of Fraxini Cortex(F. chinensis) dispensing granules based on standard decoctions is reasonable and reliable, which can provide reference for the quality control and process research of this dispensing granules.
7.Incidence and prognosis of olfactory and gustatory dysfunctions related to infection of SARS-CoV-2 Omicron strain: a national multi-center survey of 35 566 population.
Meng Fan LIU ; Rui Xia MA ; Xian Bao CAO ; Hua ZHANG ; Shui Hong ZHOU ; Wei Hong JIANG ; Yan JIANG ; Jing Wu SUN ; Qin Tai YANG ; Xue Zhong LI ; Ya Nan SUN ; Li SHI ; Min WANG ; Xi Cheng SONG ; Fu Quan CHEN ; Xiao Shu ZHANG ; Hong Quan WEI ; Shao Qing YU ; Dong Dong ZHU ; Luo BA ; Zhi Wei CAO ; Xu Ping XIAO ; Xin WEI ; Zhi Hong LIN ; Feng Hong CHEN ; Chun Guang SHAN ; Guang Ke WANG ; Jing YE ; Shen Hong QU ; Chang Qing ZHAO ; Zhen Lin WANG ; Hua Bin LI ; Feng LIU ; Xiao Bo CUI ; Sheng Nan YE ; Zheng LIU ; Yu XU ; Xiao CAI ; Wei HANG ; Ru Xin ZHANG ; Yu Lin ZHAO ; Guo Dong YU ; Guang Gang SHI ; Mei Ping LU ; Yang SHEN ; Yu Tong ZHAO ; Jia Hong PEI ; Shao Bing XIE ; Long Gang YU ; Ye Hai LIU ; Shao wei GU ; Yu Cheng YANG ; Lei CHENG ; Jian Feng LIU
Chinese Journal of Otorhinolaryngology Head and Neck Surgery 2023;58(6):579-588
Objective: This cross-sectional investigation aimed to determine the incidence, clinical characteristics, prognosis, and related risk factors of olfactory and gustatory dysfunctions related to infection with the SARS-CoV-2 Omicron strain in mainland China. Methods: Data of patients with SARS-CoV-2 from December 28, 2022, to February 21, 2023, were collected through online and offline questionnaires from 45 tertiary hospitals and one center for disease control and prevention in mainland China. The questionnaire included demographic information, previous health history, smoking and alcohol drinking, SARS-CoV-2 vaccination, olfactory and gustatory function before and after infection, other symptoms after infection, as well as the duration and improvement of olfactory and gustatory dysfunction. The self-reported olfactory and gustatory functions of patients were evaluated using the Olfactory VAS scale and Gustatory VAS scale. Results: A total of 35 566 valid questionnaires were obtained, revealing a high incidence of olfactory and taste dysfunctions related to infection with the SARS-CoV-2 Omicron strain (67.75%). Females(χ2=367.013, P<0.001) and young people(χ2=120.210, P<0.001) were more likely to develop these dysfunctions. Gender(OR=1.564, 95%CI: 1.487-1.645), SARS-CoV-2 vaccination status (OR=1.334, 95%CI: 1.164-1.530), oral health status (OR=0.881, 95%CI: 0.839-0.926), smoking history (OR=1.152, 95%CI=1.080-1.229), and drinking history (OR=0.854, 95%CI: 0.785-0.928) were correlated with the occurrence of olfactory and taste dysfunctions related to SARS-CoV-2(above P<0.001). 44.62% (4 391/9 840) of the patients who had not recovered their sense of smell and taste also suffered from nasal congestion, runny nose, and 32.62% (3 210/9 840) suffered from dry mouth and sore throat. The improvement of olfactory and taste functions was correlated with the persistence of accompanying symptoms(χ2=10.873, P=0.001). The average score of olfactory and taste VAS scale was 8.41 and 8.51 respectively before SARS-CoV-2 infection, but decreased to3.69 and 4.29 respectively after SARS-CoV-2 infection, and recovered to 5.83and 6.55 respectively at the time of the survey. The median duration of olfactory and gustatory dysfunctions was 15 days and 12 days, respectively, with 0.5% (121/24 096) of patients experiencing these dysfunctions for more than 28 days. The overall self-reported improvement rate of smell and taste dysfunctions was 59.16% (14 256/24 096). Gender(OR=0.893, 95%CI: 0.839-0.951), SARS-CoV-2 vaccination status (OR=1.334, 95%CI: 1.164-1.530), history of head and facial trauma(OR=1.180, 95%CI: 1.036-1.344, P=0.013), nose (OR=1.104, 95%CI: 1.042-1.171, P=0.001) and oral (OR=1.162, 95%CI: 1.096-1.233) health status, smoking history(OR=0.765, 95%CI: 0.709-0.825), and the persistence of accompanying symptoms (OR=0.359, 95%CI: 0.332-0.388) were correlated with the recovery of olfactory and taste dysfunctions related to SARS-CoV-2 (above P<0.001 except for the indicated values). Conclusion: The incidence of olfactory and taste dysfunctions related to infection with the SARS-CoV-2 Omicron strain is high in mainland China, with females and young people more likely to develop these dysfunctions. Active and effective intervention measures may be required for cases that persist for a long time. The recovery of olfactory and taste functions is influenced by several factors, including gender, SARS-CoV-2 vaccination status, history of head and facial trauma, nasal and oral health status, smoking history, and persistence of accompanying symptoms.
Female
;
Humans
;
Adolescent
;
SARS-CoV-2
;
Smell
;
COVID-19/complications*
;
Cross-Sectional Studies
;
COVID-19 Vaccines
;
Incidence
;
Olfaction Disorders/etiology*
;
Taste Disorders/etiology*
;
Prognosis
9. Comprehensive Evaluation and Application of Experimental Sources of Variation in Gut Microbiome Sequencing Studies
Ke-Lin XU ; Yue ZHUANG ; Si-Bo ZHU ; Jiang-Li XUE ; Yan-Feng JIANG ; Zi-Yu YUAN ; Chen SUO ; Tie-Jun ZHANG ; Ming LV ; Xing-Dong CHEN ; Si-Bo ZHU ; Yan-Feng JIANG ; Jiu-Cun WANG ; Xing-Dong CHEN ; Si-Bo ZHU ; Yan-Feng JIANG ; Xing-Dong CHEN ; Chen SUO ; Tie-Jun ZHANG ; Ming LV
Chinese Journal of Biochemistry and Molecular Biology 2022;38(7):959-970
Gut microbiome sequencing studies have great potential to translate microbial analysis outcomes into human health research. Sequencing strategies of 16S amplicon and whole-metagenome shotgun (WMS) are two main methods in microbiome research with respective advantages. However, how sample heterogeneity, sequencers and library preparation protocols affect the sequencing reproducibility of gut microbiome needs further investigation. This study aims to provide a reference for the selection of sequencing technologies by comparing differences in microbial composition from different sampling sites. The results of three widely adopted sequencers showed that the technical repetition correlation (r= 0. 94) was high in WMS method, while the biological repetition correlation (r = 0. 69) was low. Bray-Curtis distance identified that dissimilarity from biological replicates was larger than that of technical replicates (P<0. 001). In addition, dissimilarity and specific taxonomic profiles were observed between 16S and WMS datasets. Our results imply that homogenization is a necessary step before sample DNA extraction. The sequencers contributed less to taxonomic variation than the library preparation protocols. We developed an empirical Bayes approach that " borrowed information" in calculations and analyzed batch effect parameters using standardized data and prior distributions of (non-) parameters, which may improve population comparability between 16S and WMS and provide a basis for further application to fusion analysis of published 16S and microbial datasets.
10.Thunder-fire moxibustion combined with mifepristone for ovarian chocolate cyst dysmenorrhea with kidney deficiency and blood stasis: a randomized controlled trial.
Ya-Bei CHEN ; Jing LENG ; Bo-Jie LIN ; Ming-Hui XU
Chinese Acupuncture & Moxibustion 2021;41(2):161-164
OBJECTIVE:
To observe the clinical efficacy of thunder-fire moxibustion combined with mifepristone for ovarian chocolate cyst dysmenorrhea with kidney deficiency and blood stasis.
METHODS:
Seventy patients were randomly divided into an observation group and a control group, 35 cases in each group. The patients in the the control group were treated with oral administration of mifepristone, 10 mg each time, once a day; based on the treatment of the control group, the patients in the observation group were treated with thunder-fire moxibustion at Guanyuan (CV 4), Zigong (EX-CA 1), Xuehai (SP 10), once every other day. Both the groups were treated for 3 months. The Cox menstrual symptom scale (CMSS) score, the maximum cross-sectional area of ectopic cyst, and the serum levels of transforming growth factor-β1 (TGF-β1) and interleukin-17 (IL-17) were observed before and after treatment in the two groups. The clinical efficacy was evaluated.
RESULTS:
Compared before treatment, the severity scores and duration scores of CMSS as well as the serum levels of TGF-β1 were reduced after treatment in the two groups (
CONCLUSION
Thunder-fire moxibustion combined with mifepristone could significantly improve dysmenorrhea symptoms, shorten dysmenorrhea time and promote atrophy of ovarian heterotopic cyst in patients with ovarian chocolate cyst dysmenorrhea of kidney deficiency and blood stasis, and the mechanism may be related to the reduction of serum levels of TGF-β1 and IL-17.
Acupuncture Points
;
Chocolate
;
Cysts
;
Dysmenorrhea/drug therapy*
;
Female
;
Humans
;
Kidney
;
Mifepristone
;
Moxibustion

Result Analysis
Print
Save
E-mail