1.Abnormal types of intervertebral disc structure and related mechanical loading with biomechanical factors
Rui WENG ; Dongxin LIN ; Haiwei GUO ; Wensheng ZHANG ; Yuke SONG ; Hongheng LIN ; Wenchao LI ; Linqiang YE
Chinese Journal of Tissue Engineering Research 2024;28(9):1436-1442
		                        		
		                        			
		                        			BACKGROUND:The problem of intervertebral disc injury and degeneration has been studied in many ways.Many studies have shown that intervertebral disc injury and degeneration is driven by mechanical loading factors.However,the potential relationship between common phenotypes of intervertebral disc injury and degeneration and mechanical loading factors has been rarely summarized. OBJECTIVE:To summarize the types of common structural abnormalities exhibited by intervertebral disc injury and degeneration in the published literature,and sum up the potential links to the types of mechanical loading that lead to these structural abnormalities in in vitro and ex vivo experimental studies. METHODS:Using the terms"intervertebral disc failure,intervertebral disc injury,mechanical load,mechanical factor,load factor,biomechanics"as Chinese and English key words in PubMed,CNKI,and WanFang databases,articles related to intervertebral disc injury degeneration and mechanical load factors were retrieved.Literature screening was performed according to the inclusion and exclusion criteria,and 88 articles were finally included. RESULTS AND CONCLUSION:(1)Common structural abnormalities of intervertebral discs include decreased intervertebral disc height,disc bulge,osteophyte formation,annulus fibrosus tear,intervertebral disc herniation or disc prolapse,endplate damage,Schmorl nodes and intervertebral disc calcification.Intervertebral discs are susceptible to mechanical load types such as compression,bending,axial rotation,and compound loads.(2)The compressive load mainly causes the decrease of the proteoglycan content and the water-binding ability of the intervertebral disc,leading to the decrease or swelling of the intervertebral disc and further damage and degeneration of the intervertebral disc.In addition,the excessive compressive load causes greater damage to the endplate.(3)Bending load and axial rotation load damage the annulus fibrosus more than the endplate,and prolonged or repeated bending loads can cause tearing of the fibrous annulus and herniation or prolapse of the intervertebral disc,while pure axial rotation loads can induce less damage to the intervertebral disc and only cause the tear of the annulus fibrosus.(4)However,when different load types act in combination,it is more likely to result in high stress on the disc and a greater risk of disc injury.(5)Injury and degeneration of the intervertebral disc present progressive structural damage,and early prevention and protection are particularly important in clinical practice.Future tissue engineering research can start with early repair of the intervertebral disc.
		                        		
		                        		
		                        		
		                        	
2.Clinical guidelines for the treatment of ankylosing spondylitis combined with lower cervical fracture in adults (version 2024)
Qingde WANG ; Yuan HE ; Bohua CHEN ; Tongwei CHU ; Jinpeng DU ; Jian DONG ; Haoyu FENG ; Shunwu FAN ; Shiqing FENG ; Yanzheng GAO ; Zhong GUAN ; Hua GUO ; Yong HAI ; Lijun HE ; Dianming JIANG ; Jianyuan JIANG ; Bin LIN ; Bin LIU ; Baoge LIU ; Chunde LI ; Fang LI ; Feng LI ; Guohua LYU ; Li LI ; Qi LIAO ; Weishi LI ; Xiaoguang LIU ; Hongjian LIU ; Yong LIU ; Zhongjun LIU ; Shibao LU ; Yong QIU ; Limin RONG ; Yong SHEN ; Huiyong SHEN ; Jun SHU ; Yueming SONG ; Tiansheng SUN ; Yan WANG ; Zhe WANG ; Zheng WANG ; Hong XIA ; Guoyong YIN ; Jinglong YAN ; Wen YUAN ; Zhaoming YE ; Jie ZHAO ; Jianguo ZHANG ; Yue ZHU ; Yingjie ZHOU ; Zhongmin ZHANG ; Wei MEI ; Dingjun HAO ; Baorong HE
Chinese Journal of Trauma 2024;40(2):97-106
		                        		
		                        			
		                        			Ankylosing spondylitis (AS) combined with lower cervical fracture is often categorized into unstable fracture, with a high incidence of neurological injury and a high rate of disability and morbidity. As factors such as shoulder occlusion may affect the accuracy of X-ray imaging diagnosis, it is often easily misdiagnosed at the primary diagnosis. Non-operative treatment has complications such as bone nonunion and the possibility of secondary neurological damage, while the timing, access and choice of surgical treatment are still controversial. Currently, there are no clinical practice guidelines for the treatment of AS combined with lower cervical fracture with or without dislocation. To this end, the Spinal Trauma Group of Orthopedics Branch of Chinese Medical Doctor Association organized experts to formulate Clinical guidelines for the treatment of ankylosing spondylitis combined with lower cervical fracture in adults ( version 2024) in accordance with the principles of evidence-based medicine, scientificity and practicality, in which 11 recommendations were put forward in terms of the diagnosis, imaging evaluation, typing and treatment, etc, to provide guidance for the diagnosis and treatment of AS combined with lower cervical fracture.
		                        		
		                        		
		                        		
		                        	
3.Silencing MARK4 inhibits apoptosis and inflammatory factor expression of in ulcerative colitis via NF-κB signaling pathway
Lu YE ; Shengtao LIAO ; Chuanfei LI ; Jianlin SU ; Xinglian YU ; Yanhui WANG ; Ya SONG ; Lin LYU
Immunological Journal 2024;40(2):131-137
		                        		
		                        			
		                        			This study was designed to investigate the effect of silencing microtubule-affinity regulating kinase 4(MARK4)on the apoptosis,inflammatory cytokine release and intestinal barrier protein expression of FHC cells in a lipopolysaccharide(LPS)-induced ulcerative colitis(UC)model,and the underlying molecular mechanisms.Western blot analysis was used to measure the expression levels of MARK4 and apoptosis-related factors including Caspase-1,NLRP3,and GSDMD in colon tissues from both UC patients and healthy individuals,as well as in LPS-induced FHC cell inflammation model.FHC cells was transfected with shRNA to silence MARK4.In control(normal FHC cells),LPS(LPS-stimulated FHC cells),and MARK4-silenced+LPS(shRNA-and LPS-treated FHC cells)groups,the expression levels of Caspase-1,NLRP3,GSDMD,intestinal barrier proteins,and NF-κB pathway-related proteins were assessed by Western blotting.ELISA and RT-qPCR were used to measure the expression levels of inflammatory cytokines IL-1β,IL-6,and TNF-α;flow cytometry was utilized to assess apoptosis.Data showed that both in UC patient colon tissues and the in vitro LPS-induced FHC cell UC inflammation model,there was a significant increase in the expression of MARK4 and apoptosis-related proteins including NLRP3,Caspase-1,and GSDMD.Silencing MARK4 inhibited the expression of these apoptosis-related proteins and downregulated the inflammatory cytokines IL-1β,IL-6,and TNF-α in LPS-induced FHC cells.Silencing MARK4 also reduced apoptosis,increased the expression of intestinal barrier proteins ZO-1,Occludin,and upregulated Claudin2.Gene Set Enrichment Analysis(GSEA)indicated a positive correlation between MARK4 and the NF-κB signaling pathway.Furthermore,silencing of MARK4 inhibited the expression levels of p-P65 and p-IKKα in the NF-κB pathway.In conclusion,MARK4 is significantly upregulated in UC tissues and cells.Silencing MARK4 inhibits the activation of the NF-κB signaling pathway,thereby inhibiting the apoptosis and inflammatory factor expression of UC cells.Thus,MARK4 could be a potential therapeutic target for UC patients.
		                        		
		                        		
		                        		
		                        	
4.Percutaneous pedicle screw anchored vertebral augmentation for the treatment of Kümmell disease without neuro-logical symptoms
Song-Hai CHEN ; Lin-Qiang YE ; Ze-Lin ZHOU ; Guo-Liang LU
China Journal of Orthopaedics and Traumatology 2024;37(5):470-476
		                        		
		                        			
		                        			Objective To explore the clinical effect of percutaneous pedicle screw anchored vertebral augmentation(PP-SAVA)in the treatment of asymptomatic Kümmell disease without neurological symptoms.Methods The clinical data of 20 patients with Kümmell disease without neurological symptoms treated with PPSAVA in our hospital from January 2019 to De-cember 2021 were analyzed retrospectively,including 5 males and 15 females,aged 56 to 88(74.95±9.93)years old.and the course of disease was 7 to 60 days with an average of(21.35±14.46)days.All patients were treated with PPSAVA.The time of operation,the amount of bone cement injected and the leakage of bone cement were recorded.The visual analogue scale(VAS),Oswestry disability index(ODI),vertebral body angle(VBA),anterior edge height and midline height of vertebral body were compared among the before operation,3 days after operation and during the final follow-up.The loosening and displace-ment of bone cement were observed during the final follow-up.Results All the 20 patients completed the operation successfully.The operation time was 30 to 56 min with an average of(41.15±7.65)min,and the amount of bone cement injection was 6.0 to 12.0 ml with an average of(9.30±1.49)ml.Bone cement leakage occurred in 6 cases and there were no obvious clinical symp-toms.The follow-up time was 6 to 12 months with an average of(8.43±2.82)months.The VBA,anterior edge height and mid-line height of of injured vertebral body were significantly improved 3 days after operation and the final follow-up(P<0.05),and the VBA,anterior edge height and midline height of of injured vertebral body were lost in different degrees at the final follow-up(P<0.05).The VAS and ODI at 3 days after operation and at the final follow-up were significantly lower than those at preopera-tively(P<0.05),but the VAS score and ODI at the final follow-up were not significantly different from those at 3 d after opera-tion(P>0.05).At the last follow-up,no patients showed loosening or displacement of bone cement.Conclusion PPSAVA is highly effective in treating Kümmell disease without neurological symptoms,improving patients'pain and functional impair-ment,and reducing the risk of cement loosening and displacement postoperatively.
		                        		
		                        		
		                        		
		                        	
5.Thoughts and suggestions on digital services to enhance the level of vaccination management
Lin LUAN ; Na LIU ; Benfeng ZHENG ; Zhuoyu ZHANG ; Yifan SONG ; Li LI ; Ming GAN ; Lei CAO ; Zhuoying HUANG ; Jiakai YE ; Zhaonan ZHANG ; Xiaoxue LIU ; Junlei CHEN ; Changshuang WANG ; Bi CAI ; Wenzhou YU
Chinese Journal of Preventive Medicine 2024;58(2):159-165
		                        		
		                        			
		                        			With the development of information technology and the increasing demand for vaccination services among the people, it is a definite trend to enhance the quality of vaccination services through digitization. This article starts with a clear concept of digital services for vaccination, introduces the current development status in China and abroad, analyzes the advantages and disadvantages of existing models in leading regions, takes a glean from the summation, and proposes targeted solutions. This study suggests establishing a departmental coordination mechanism for data interconnection and sharing, formulating data standards and functional specifications, enhancing the functionalities of the immunization planning information system, strengthening data collection and analytical usage, and intensifying appointment management and science and health education to provide expert guidance for the construction of digital vaccination services across the country in the future.
		                        		
		                        		
		                        		
		                        	
6.Application of a Kolb's model-based two-way six-step nursing training cycle in the teaching of nurse interns in the department of emergency
Aqiao SUN ; Ye SONG ; Xuehong WANG ; Kangjuan HAO ; Lin HAO ; Minling LI
Chinese Journal of Medical Education Research 2024;23(9):1264-1269
		                        		
		                        			
		                        			Objective:To investigate the application effects of a two-way six-step nursing teaching model based on the Kolb's learning cycle in the teaching of nurse interns in an emergency department.Methods:We assigned 52 undergraduate nursing students interning at the department of emergency from February 2020 to February 2022 to receive conventional teaching (control group) and 50 nurse interns from March 2022 to February 2023 to receive two-way six-step nursing teaching based on the Kolb's model (observation group). We evaluated the changes in core competencies before and after learning using the Competency Inventory for Registered Nurses (CIRN); assessed self-learning abilities using a nursing student self-learning ability assessment scale; recorded the incidence rates of related errors in the emergency department after learning; and assessed the level of satisfaction with nursing using the Patient Satisfaction Questionnaire (PSQ-18). SPSS 22.0 was used to perform the chi-square test and t-test. Results:After learning, the scores of CIRN dimensions and self-learning ability dimensions were all increased in both groups, and these scores were significantly higher in the observation group [(31.78±2.34), (50.22±4.33), (28.56±2.09), (19.22±3.11), (22.34±2.78); (30.07±3.14), (24.11±2.99), (30.11±3.41), (33.33±3.09)] than in the control group [(30.88±2.22), (48.34±3.88), (27.59±2.52), (17.77±3.08), (20.88±2.55); (28.67±2.09), (22.56±2.44), (27.99±3.03), (31.33±3.44)]. Compared with the control group, the observation group showed significantly lower incidence rates of errors in the execution of medical orders (19.23% vs. 2.00%, P=0.008) and errors in practice in accordance with standards (15.38% vs. 0.00%, P=0.006). There were no significant differences in the incidence rates of poor response on the spot, medical record errors, and medical dispute errors between the observation group and the control group (all P>0.05). The PSQ-18 scores in all dimensions of the observation group were significantly higher than those of the control group ( P=0.002, 0.001, 0.014, 0.008, <0.001). Conclusions:The two-way six-step nursing teaching model based on the Kolb's model can significantly improve the core competencies and self-learning abilities of nursing students in the department of emergency, and reduce errors in the execution of medical orders and practice in accordance with standards, thus improving their nursing service levels.
		                        		
		                        		
		                        		
		                        	
7.Cerebral oxygen metabolism and brain electrical activity of healthy full-term neonates in high-altitude areas:a multicenter clinical research protocol
Bi ZE ; Jin GAO ; Xiao-Fen ZHAO ; Yang-Fang LI ; Tie-Song ZHANG ; Xiao-Mei LIU ; Hui MAO ; Ming-Cai QIN ; Yi ZHANG ; Yong-Li YANG ; Chun-Ye HE ; Yan ZHAO ; Kun DU ; Lin LIU ; Wen-Hao ZHOU ; Chinese High Altitude Neonatal Medicine Alliance
Chinese Journal of Contemporary Pediatrics 2024;26(4):403-409
		                        		
		                        			
		                        			Further evidence is needed to explore the impact of high-altitude environments on the neurologic function of neonates.Non-invasive techniques such as cerebral near-infrared spectroscopy and amplitude-integrated electroencephalography can provide data on cerebral oxygenation and brain electrical activity.This study will conduct multiple cerebral near-infrared spectroscopy and amplitude-integrated electroencephalography monitoring sessions at various time points within the first 3 days postpartum for healthy full-term neonates at different altitudes.The obtained data on cerebral oxygenation and brain electrical activity will be compared between different altitudes,and corresponding reference ranges will be established.The study involves 6 participating centers in the Chinese High Altitude Neonatal Medicine Alliance,with altitude gradients divided into 4 categories:800 m,1 900 m,2 400 m,and 3 500 m,with an anticipated sample size of 170 neonates per altitude gradient.This multicenter prospective cohort study aims to provide evidence supporting the impact of high-altitude environments on early brain function and metabolism in neonates.[Chinese Journal of Contemporary Pediatrics,2024,26(4):403-409]
		                        		
		                        		
		                        		
		                        	
8.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
		                        		
		                        			
		                        			【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
		                        		
		                        		
		                        		
		                        	
9.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
		                        		
		                        			
		                        			【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
		                        		
		                        		
		                        		
		                        	
10.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
		                        		
		                        			
		                        			【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
		                        		
		                        		
		                        		
		                        	
            
Result Analysis
Print
Save
E-mail