1.Spectral CT quantitative parameters for evaluating T stage of advanced gastric cancer
Yaru YOU ; Yiyang LIU ; Mengchen YUAN ; Shuai ZHAO ; Liming LI ; Yusong CHEN ; Yue ZHENG ; Jianbo GAO
Chinese Journal of Medical Imaging Technology 2024;40(11):1704-1709
Objective To observe the value of spectral CT parameters for evaluating T staging of advanced gastric cancer(AGC).Methods Totally 155 AGC patients were collected and divided into T2 stage(n=40)and T3/4a stage(n=115)according to postoperative pathology.CT values,water concentration(WC)and iodine concentration(IC)of AGC lesions on 40-140 keV arteriovenous phase single energy level images were measured,and the standardized IC(nIC)and spectral curve slopes k1 and k2 were calculated.Clinical variables and spectral quantitative parameters were compared between groups,and receiver operating characteristic curve was plotted,the area under the curve(AUC)was calculated to evaluate the value of each parameter and model for identifying T2 and T3/4a stage AGC.Results Tumor thickness,proportion of low differentiation degree,CT100kev,CT140kev,and WC values in T3/4a group were all significantly higher than those in T2 group(all P<0.05).CT140keV of AGC lesions on venous phase images presented the highest discrimination efficacy among single parameters,with AUC of 0.782.AUC of clinical-arterial phase-venous phase model was 0.848,higher than that of clinical model and arterial phase model alone(both P<0.05)but not significantly different compared with AUC of venous phase model(P>0.05).Conclusion Spectral CT quantitative parameters,especially venous phase parameters could be used to effectively identify T stage of AGC.Multi-parameter combined models had higher diagnostic value.
2.Relational model of factors influencing fluid management in hemodialysis patients based on the health belief model
Chen CHEN ; Jing ZHENG ; Xu LIU ; Jiali LIU ; Liming YOU
Chinese Journal of Nursing 2023;58(24):2996-3003
Objective To investigate the influencing factors and pathways of fluid management adherence and interdialytic weight control in hemodialysis patients based on the health belief model.Methods Using convenience sampling,433 patients receiving hemodialysis were included from 4 hospitals in Guangdong province.The demographic and clinical data questionnaire,Health Belief Scale of Fluid Restriction,and Fluid Intake Adherence Scale were used.The relative-interdialytic weight gain(R-1DWG)was calculated.Results The mean score of patients'fluid management adherence was 3.08±0.97,indicating a moderate level,with 35.57%of patients exceeding the required R-IDWG standard.Regarding health beliefs,perceived benefits(β=0.161)and self-efficacy(β=0.685)of fluid restriction directly affected fluid adherence;perceived threats of poor fluid restriction indirectly affected fluid management adherence through perceptions of benefits and self-efficacy(β=0.235);perceived barriers were indirectly and negatively associated with fluid management adherence through self-efficacy(β=-0.246).Higher fluid management adherence was associated with better control of R-IDWG(β=-0.361).Regarding the coordinating factors,age,educational level,hemodialysis vintage and diabetes were influential factors of fluid management adherence(|β|:0.050-0.162)and R-IDWG control(|β |:0.049-0.309).The coefficients(β)of each path were statistically significant(P<0.05).Conclusion Healthcare providers should comprehensively assess patients'health beliefs,focus on patients with lower educational levels and diabetes,and identify weakness in their fluid management to achieve the required R-IDWG standard.
3.Research progress in pulmonary electrical impedance tomography for ventilation functional evaluation following multiple rib fracture
Liming WANG ; Lingqing ZHOU ; Picong YOU
Chinese Journal of Trauma 2022;38(12):1147-1152
Multiple rib fracture is a common chest injury that can cause severe pain and seriously affect life quality of the patients. The traditional pulmonary function test can only assess changes in total lung volume and ventilation of the multiple rib fracture, but fails to reveal regional ventilation status in rib fracture area and ventilation differences within the whole lung. Instead, pulmonary electrical impedance tomography (EIT), as a novel bedside technique for ventilation monitoring, has advantages of non-invasiveness, non-use of radiative rays and dynamic visualization of regional ventilation, enabling to quantify ventilation defects and heterogeneity in space and time. Starting with the assessment of ventilation changes and research status of ventilation function in multiple rib fracture and the characteristics of EIT, the authors review the research progress in the evaluation of ventilation function following multiple rib fracture based on EIT, with the aim to provide new insight into the research on ventilation changes after multiple rib fracture.
4.Screening of Molecular Markers of Cisplatin Resistance in Lung Adenocarcinoma and Functional Verification Based on TCGA Database
Lin WANG ; Zixian HUANG ; Chengcheng YOU ; Shunzi TAN ; Liming HUANG ; Yiling HUANG
Cancer Research on Prevention and Treatment 2022;49(6):569-574
Objective To explore the related genes that play a key regulatory role in cisplatin resistance in lung adenocarcinoma. Methods Bioinformatics methods were used to download the differentially-expressed genes between cisplatin sensitive group and drug resistant group in patients with lung adenocarcinoma in TCGA database and GDSC database. GO function analysis and KEGG pathway enrichment analysis were carried out to analyze the differentially-expressed genes. The protein-protein interaction network was constructed and hierarchical cluster analysis was carried out to screen the key genes. The key genes were verified at the cell level by real-time fluorescence quantitative PCR and ELISA. Then the expression of the selected key gene in A549/DDP cells was silenced by siRNA and its sensitivity to cisplatin was detected. Results We screened out 178 differentially-expressed genes. After cluster analysis, CXCL9, CXCL10, NKX2-1 and SFTPA1 were regarded as the key genes of cisplatin resistance in lung adenocarcinoma. CXCL10 was temporarily selected for subsequent verification and function experiment. The mRNA expression of CXCL10 in A549/DDP cells was significantly higher than that in A549 cells (
5.The study on indocyanine green excretion test to predict mild hepatic encephalopathy
Kanglai LI ; Shan OUYANG ; Lihua ZHENG ; Yuanli CHEN ; Liming YOU ; Xiaolan LIN
Chinese Journal of Practical Nursing 2021;37(15):1134-1139
Objective:To explore whether the 15-minute retention rate (R15) of indocyanine green (ICG) in the indocyanine green excretion test and the effective hepatic blood flow (EHBF) can predict the occurrence of mild hepatic encephalopathy (MHE).Methods:Using the convenience sampling method, we collected clinic data from 153 patients diagnosed with liver cirrhosis or liver failure from June 2019 to December 2019 in the Third Affiliated Hospital of Sun Yet-sen University in Guangzhou. We screened the MHE patients with the number connect test-A and the digital symbol test, and analyzed the clinical data. By taking different values for R15 and EHBF as cut-off points, the significance of the two factors in predicting MHE is explored respectively.Results:The incidence of MHE was 38.56% (59/153). Single factor analysis showed that the difference of Child-Pugh grade between the MHE group and the non-MHE group was statistically significant ( χ2 value was 7.606, P<0.05), while the differences between cirrhosis and liver failure diagnosis, fasting blood glucose, and serum creatinine were not statistically significant ( P>0.05). When most points between 0.11 and 0.61 were selected as normal and abnormal cut-off points of R15, R15 had statistical significance ( P<0.05) and when R15 selected 0.18, it was most significant (Fisher exact test P=0.00024). When most points between 0.08 and 0.76 were selected as normal abnormal cut-off points of EHBF, EHBF had statistical significance ( P<0.05) and when EHBF selected 0.25, it was most significant (Fisher exact test P=0.00022). Through Logistic stepwise regression analysis, the risk factors for MHE were R15 and EHBF. The ROC curve was used to illustrate the predictive effects of two factors on MHE. Conclusions:The incidence of MHE in patients with cirrhosis or liver failure is high. When R15≥0.18 or EHBF≤0.25 L/min, R15 and EHBF in indocyanine green excretion test can better predict the occurrence of MHE than Child-Pugh classification, and can be help to evaluate and manage patients in time.
6.Applying Rasch analysis to transforming scores on the activities and participation component of the ICF Rehabilitation Set: A multicenter study
Yan GAO ; Tiebin YAN ; Liming YOU ; Kun LI ; Lifang ZHANG
Chinese Journal of Physical Medicine and Rehabilitation 2020;42(8):685-689
Objective:To explore the suitability of using Rasch analysis to transform scores on the Activities and Participation component of the ICF Rehabilitation Set.Methods:Between January and May 2017, five hundred and fifteen post-acute rehabilitation patients were recruited in 13 research centers through quota sampling. Specially-trained health professionals used the Activities and Participation component of the ICF Rehabilitation Set to collect data. Rasch analysis was performed using RUMM 2030 software to test for goodness of fit, threshold estimates, and local dependency.Results:Of the five hundred and fifteen participants, 279 (54.2%) had a neurological condition, 119 (23.1%) a cardiopulmonary condition, 49 (10.0%) a musculoskeletal condition, and 68 (13.2%) some other condition. After Rasch analysis, the Activities and Participant component of the ICF Rehabilitation Set was divided into two domains: Activities, and Participation with 9 categories under activities and five under participation.Conclusions:After rescoring the response options, deleting four poorly-fitting categories and generating one testlet, it was found that the activities and participation component the ICF Rehabilitation Set can be divided into two outcome measures to be applied in clinical practice.
7.The value of establishment of virtual stent model for preoperative simulation in TIPS treatment
Xin WEI ; Hong HU ; Jian YOU ; Liming ZHONG ; Yunguo LIAO ; Xing DENG ; Jiaqi PU ; Dan DENG
Journal of Practical Radiology 2018;34(4):586-588,595
Objective To establish virtual three-dimensional models of interventional devices and individualized surgical area structure in transjugular intrahepatic portosystemic shunt(TIPS)treatment,and to explore the value of virtual models for preoperative simulation in TIPS treatment.Methods Thin slice scan data of 8 patients with supine upper abdomen were obtained,three dimensional structures of bone,liver,portal vein,inferior vena cava and hepatic vein in CT scan area were reconstructed in Mimics software.According to the size of interventional instruments,a virtual RUPS-100 puncture kit and an VIATORR stent were established in 3D MAX software. Computer simulations were performed to evaluate the route from the hepatic vein puncture portal vein using the RUPS-100 puncture kit and VIATORR stent release position.Results ①The establishment of individual three-dimensional model of patients was helpful for doctors to understand the spatial relation of hepatic vein and portal vein.②Through simulation,the puncture parameters of multi angle and multi position are obtained,which was helpful for the doctor to adjust the puncture direction according to the puncture point.③The position of the bare segment of the VIATORR stent in the portal vein was obtained by simulation,which was helpful for evaluating the length of the stent.④The preoperative simulation results included the simulation parameters for each patient puncture into left portal vein,right portal vein and portal vein bifurcation.In the actual operation,we punctured into the portal vein bifurcation in 4 cases,into the right branch in 2 cases and into the left in 2 cases.⑤Preoperative simulations were performed using 8 mm×6 cm×2 cm size VIATORR stent.Howere,the actual operation of the first case was lack of experience,and the stent position was lower,then we released a bare stent at the proximal end of the VIATORR stent.The rest of the cases were the same as the simulation results.Conclusion According to the three-dimensional model of the individual structure of the patient,the preoperative simulations have high fidelity.The simulation results of the parameters of the puncture and the release position of the stent could guide the actual operation more accurately.It is of practical value to improve the success rate of operation and to train residents.
8.RhoA/mDia1 pathway involved in the expression of p-ERM in the pulmonary micro-vascular endothelial cell induced by lipopolysaccharide
Xueting LIU ; Gengyun SUN ; Qinghai YOU ; Liming FEI
Chinese Journal of Emergency Medicine 2017;26(3):272-277
Objective To investigate the possibility of the involvement of RhoA/mDia1 pathway to cause the expression of phosphorylate ezrin-radixin-moesin (p-ERM) in rat pulmonary micro-vascular endothelial cell (PMVEC) after the stimulation of lipopolysaccharide (LPS).Methods The specimens of lung tissue were taken from healthy male SPF grade SD rat with 100-120 g body weight which was purchased from the laboratory animal center of Anhui province.After culture,the PMVECs were randomly divided into dose-dependent groups (0,0.1,1,10 μg/mL LPS added in PMVECs and cultured for30 min,n =8 in each),time-dependent groups (10 μg/mL LPS added to PMVECs cultured for 0,15,30,60,120 min,n =8 in each) and intervention group (n =8).In the intervention group,PMVECs were cultured with 1 μg/mL C3 transferase in serum free media for 240 min,followed by treatment with 10 μg/mL LPS for 30 min.Meanwhile,two control groups in serum-free DMEM medium were made by adding 10.μg/mL LPS to PMVECs and 1 μg/mL C3 transferase to PMVECs respectively cultured for 30 min (n =8 in each).Western blot was used to detect the level of p-ERM,ERM and mDia1.Data were analyzed with SPSS 16.0 software,while one way analysis of variance (ANOVA) was used to compare multiple sets of variables,the intergroup comparisons were analyzed by the least-significant-difference (LSD) tests,with P <0.05 for the statistically significant difference.Results ERM,p-ERM and mDia1 were presented in rat PMVEC.Stimulation with LPS up-regulated p-ERM,mDia1 in a dose-dependent manner:LPS [0 μg/mL LPS group:(0.520±0.101),0.1 μg/mL LPS group:(0.657 ±0.092),1 μg/mL LPS group:(0.891 ±0.167),10 μg/mL LPS group:(1.227 ±0.106);0 μg/mL group vs.0.1 μg/mL group,P >0.05;the rest P <0.01];and mDia1 [0 μg/mL LPS group:(0.200 ±0.102),0.1 μg/mL LPS group:(0.430 ±0.121),1 μg/mL LPS group:(0.603 ±0.154),10 μg/mL LPS group:(0.887 ±0.204);0.1 μg/mL group vs.1 μg/mL group,P > 0.05;the rest P < 0.05].In time-dependent group,the level of p-ERM protein increased at 15 min (0.670 ±0.149),peaked at 30 min (1.175 ±0.103),then decreased,at 60 min (0.959 ±0.189),90 min (0.842 ±0.129),but kept at higher level at 120 min (0.767 ±0.097) than that in control group (0.471 ±0.157,15 min group vs.120 min group,60 min group vs.90 min group and 90 min group vs.120 min group,P > 0.05;the rest P < 0.05);and the level of mDia1 increased at 15 min (0.779 ±0.035),peaked at 30 min (0.889 ±0.036) then decreased at 60 min (0.648 ±0.019),90 min (0.582 ±0.068),but kept at higher level at 120 min (0.526 ±0.059) than that in control group (0.284±0.118,all P < 0.01).C3 transferase caused a marked attenuation of LPS induced p-ERM expression [control group:(0.339 ± 0.069);C3 + LPS group:(0.438 ± 0.07);C3 control group:(0.352 ± 0.071);LPS control group:(0.634 ± 0.191),C3 + LPS group vs.LPS control group,P =0.01],as the same in mDia1 [control group:(0.449 ±0.122);C3 + LPS group:(0.380 ±0.148);C3 control group:(0.404 ±0.164);LPS control group:(0.622 ±0.174),C3 + LPS group vs.LPS control group,P < 0.01].Conclusions LPS could up-regulated the expression of p-ERM protein,and inhibition of RhoA/mDia1 signal pathway by C3 transferase could down-regulated the p-ERM levels.
9. Comparison of aortic annular diameter defined by different measurement mordalities before transcatheter aortic valve implantation
Ruixiang QI ; Xiangdong YOU ; Zhaoxia PU ; Qian YANG ; Zhaoxu HUANG ; Liming ZHOU ; Pintong HUANG
Chinese Journal of Cardiology 2017;45(5):409-414
Objective:
To compare aortic annular diameter measured by transthoracic echocardiography (TTE), transesophageal echocardiography (TEE), and multislice computed tomography (MSCT) in patients with severe aortic stenosis, and to evaluate the impact on selection of prosthetic valve type in transcatheter aortic valve implantation (TAVI).
Methods:
Clinical data of 138 patients with severe aortic stenosis referred for TAVI between January 2014 and June 2016 in our hospital were retrospectively analyzed.The difference of aortic annular diameter measured by TTE, TEE, and MSCT were compared.TTE was performed after TAVI to evaluate the accuracy of measurement before TAVI.
Results:
(1) Aortic annular diameter was (23.37±2.22) mm by TTE and (23.52±1.70) mm by TEE (
10.Research progress on the relationship of nursing work environment and patient safety
Duoduo PEI ; Jing ZHENG ; Ke LIU ; Liming YOU
Chinese Journal of Practical Nursing 2017;33(23):1832-1835
Nursing work environment impacts patient outcomes. This article summarized the concept and connotation of nursing work environment, related theories of how nursing work environment impacts patient safety outcomes and related researches conducted by foreign scholars. The effort of this review article aims to put forward new research direction.

Result Analysis
Print
Save
E-mail