1.Clinical profile and outcomes of central microbial keratitis in the Philippines.
Ma. Dominga B. PADILLA ; Ruben Lim BON SIONG ; George Michael N. SOSUAN
Philippine Journal of Ophthalmology 2025;50(1):26-32
OBJECTIVE
Despite being a preventable and treatable condition, central microbial keratitis (CMK) and its complications remain to be a significant cause of vision loss in our country. This study presents the demographic profile, risk factors, etiologies, treatments, and outcomes of CMK in the Philippines.
METHODSThe study was a two-center, prospective, non-randomized clinical study involving the patients of the External Disease and Cornea Clinics of two tertiary eye referral centers in the Philippines. It was conducted as the Philippine leg of the Asia Cornea Society Infectious Keratitis Study (ASCIKS).1 Patients with a clinical diagnosis of CMK rendered by a cornea specialist, and who signed the consent form, were recruited into the study. They underwent uniform sample collection and culture techniques as described in the ACSIKS. All patients were followed-up for 6 months. Data collected included demographics, risk factors, culture results, management, and treatment outcomes. Descriptive statistics and frequency were used to analyze the data.
RESULTSA total of 348 patients diagnosed with CMK were included. Trauma (65.5%) among the middle-aged (42.9 ± 17.9 years) male population was the most significant risk factor for development of CMK, followed by contact lens wear (12.9%), prior ocular surgery (6.0%), and ocular surface diseases (3.4%). Bacterial keratitis (53.2%) was still the most common etiology of CMK, followed by fungal keratitis (27.0%), Acanthamoeba keratitis (5.7%), and viral keratitis (2.0%). Aspergillus species (18.3%) were the most common microbial isolates. Pseudomonas species (13.9%) were the most common bacterial isolates. The median time from onset of symptoms to consultation with the study centers was 2 weeks. Medical treatment was enough to treat the infection in 34.8% of cases. Surgical intervention was necessitated in 22.6% with evisceration/enucleation done in 1 out of 3 patients who had surgery.
CONCLUSIONBacterial infection remains the most common cause of CMK in the Philippines, followed by fungal infection. Significant risk factors include trauma and contact lens wear. Aspergillus species and Pseudomonas species were the most common fungal and bacterial isolates, respectively. Despite medical treatment, almost a quarter of the cases still required surgical intervention.
Human ; Fungi ; Bacteria ; Philippines ; Vision, Ocular ; Keratitis
2.Preclinical Image Quality Evaluation of Simultaneous Vision Intraocular Lenses.
Qin FENG ; Qi HAO ; Ting SONG ; Qionghui CHEN
Chinese Journal of Medical Instrumentation 2023;47(1):93-98
Three different preclinical evaluation methods of MTF through-frequency response, MTF through-focus-response and expected visual acuity were used to compare and analyze the imaging differences of IOLs with four different optical designs. The research work could be used in the simultaneous vision IOLs in the optical design stage and verify the optical quality of the IOLs, the results can predict the visual representation of the patients better. The evaluation results can provide reference for IOL manufacturers and users in product design, development, validation and application selection.
Humans
;
Prosthesis Design
;
Lenses, Intraocular
;
Vision, Ocular
;
Visual Acuity
3.A review of studies on visual behavior analysis aided diagnosis of autism spectrum disorders.
Journal of Biomedical Engineering 2023;40(4):812-819
Autism spectrum disorder (ASD) is a neurodevelopmental disorder characterized by deficits in social communication and repetitive behaviors. With the rapid development of computer vision, visual behavior analysis aided diagnosis of ASD has got more and more attention. This paper reviews the research on visual behavior analysis aided diagnosis of ASD. First, the core symptoms and clinical diagnostic criteria of ASD are introduced briefly. Secondly, according to clinical diagnostic criteria, the interaction scenes are classified and introduced. Then, the existing relevant datasets are discussed. Finally, we analyze and compare the advantages and disadvantages of visual behavior analysis aided diagnosis methods for ASD in different interactive scenarios. The challenges in this research field are summarized and the prospects of related research are presented to promote the clinical application of visual behavior analysis in ASD diagnosis.
Humans
;
Autism Spectrum Disorder/diagnosis*
;
Vision, Ocular
;
Behavior
4.The Value of VR-PVEP in Objective Evaluation of Monocular Refractive Visual Impairment.
Hong-Xia HAO ; Jie-Min CHEN ; Rong-Rong WANG ; Xiao-Ying YU ; Meng WANG ; Zhi-Lu ZHOU ; Yan-Liang SHENG ; Wen-Tao XIA
Journal of Forensic Medicine 2023;39(4):382-387
OBJECTIVES:
To study the virtual reality-pattern visual evoked potential (VR-PVEP) P100 waveform characteristics of monocular visual impairment with different impaired degrees under simultaneous binocular perception and monocular stimulations.
METHODS:
A total of 55 young volunteers with normal vision (using decimal recording method, far vision ≥0.8 and near vision ≥0.5) were selected to simulate three groups of monocular refractive visual impairment by interpolation method. The sum of near and far vision ≤0.2 was Group A, the severe visual impairment group; the sum of near and far vision <0.8 was Group B, the moderate visual impairment group; and the sum of near and far vision ≥0.8 was Group C, the mild visual impairment group. The volunteers' binocular normal visions were set as the control group. The VR-PVEP P100 peak times measured by simultaneous binocular perception and monocular stimulation were compared at four spatial frequencies 16×16, 24×24, 32×32 and 64×64.
RESULTS:
In Group A, the differences between P100 peak times of simulant visual impairment eyes and simultaneous binocular perception at 24×24, 32×32 and 64×64 spatial frequencies were statistically significant (P<0.05); and the P100 peak time of normal vision eyes at 64×64 spatial frequency was significantly different from the simulant visual impairment eyes (P<0.05). In Group B, the differences between P100 peak times of simulant visual impairment eyes and simultaneous binocular perception at 16×16, 24×24 and 64×64 spatial frequencies were statistically significant (P<0.05); and the P100 peak time of normal vision eyes at 64×64 spatial frequency was significantly different from the simulant visual impairment eyes (P<0.05). In Group C, there was no significant difference between P100 peak times of simulant visual impairment eyes and simultaneous binocular perception at all spatial frequencies (P>0.05). There was no significant difference in the P100 peak times measured at all spatial frequencies between simulant visual impairment eyes and simultaneous binocular perception in the control group (P>0.05).
CONCLUSIONS
VR-PVEP can be used for visual acuity evaluation of patients with severe and moderate monocular visual impairment, which can reflect the visual impairment degree caused by ametropia. VR-PVEP has application value in the objective evaluation of visual function and forensic clinical identification.
Humans
;
Evoked Potentials, Visual
;
Vision, Ocular
;
Vision, Binocular/physiology*
;
Vision Disorders/diagnosis*
;
Virtual Reality
5.Restoring Vision Naturally and Noninvasively.
Chundi WANG ; Hu DENG ; Shenbing KUANG
Neuroscience Bulletin 2021;37(11):1642-1644
6.Observation of acupoint thread-embedding on refractive amblyopia in children.
Cai-Lian AN ; Yan ZHOU ; Xing-Ke YAN
Chinese Acupuncture & Moxibustion 2021;41(7):747-750
OBJECTIVE:
To observe the effect of acupoint thread
METHODS:
A total of 60 children with refractive amblyopia were randomized into an observation group (30 cases, 2 cases dropped off) and a control group (30 cases, 1 case dropped off). In the control group, comprehensive therapy of eye covering of intact side and family refined performance was adopted. On the basis of the treatment in the control group, acupoint thread
RESULTS:
After treatment, the corrected vision was increased compared before treatment in the both groups (
CONCLUSION
Acupoint thread
Acupuncture Points
;
Amblyopia/therapy*
;
Child
;
Humans
;
Retina
;
Vision, Ocular
;
Visual Acuity
7.A comparative evaluation of visual, refractive, and patient-reported outcomes of three diffractive trifocal intraocular lenses
Robert Edward T. Ang ; Janice Marie N. Jordan-Yu ; Mark Sylvester F. Agas ; Ryan S. Torres ; Emerson M. Cruz
Philippine Journal of Ophthalmology 2020;45(1):28-40
OBJECTIVE: To compare the visual, refractive, and patient-reported outcomes of eyes implanted with one of 3 trifocal intraocular lenses (IOLs).
METHODS: This is a cross-sectional, comparative, non-interventional study wherein subjects implanted with FineVision Micro F, AT LISA tri 839MP or AcrySof IQ PanOptix trifocal IOL after phacoemulsification were recruited. Manifest refraction, uncorrected and corrected visual acuity (VA) at distance, intermediate and near vision, contrast sensitivity, modulated transfer function (MTF) values and questionnaire answers were compared among the 3 groups using analysis of variance (ANOVA).
RESULTS: Fifty-seven (57) eyes were included in the study: 21 eyes with FineVision (group A), 21 eyes with LISA tri (group B), and 15 eyes with PanOptix IOL (group C). The post-operative mean manifest spherical equivalent was -0.01D, -0.07D, and 0.05D, respectively (p=0.083). Uncorrected distance VA and best-corrected distance VA were similar among the groups. Groups A and C had better uncorrected and corrected intermediate VA at 80 cm and at 60 cm compared to group B. Group A had significantly better uncorrected near visual acuity than groups B and C (p=0.032). Mesopic contrast sensitivity testing showed group C had higher contrast sensitivities without glare in at the spatial frequency of 6 CPD (p=0.038) and with glare at 3 CPD (p=0.039) and at 12 CPD (p=0.009). MTF average height analysis showed that the group A had significantly superior resolution in far targets compared to groups B and C (p=0.001). At near targets, groups A and C had better resolutions compared to group B (p=0.017). There was no significant difference in patient satisfaction for far, intermediate and near VA among the groups.
CONCLUSION: Eyes implanted with any of the 3 trifocal IOL designs achieved excellent uncorrected and bestcorrected distance, intermediate and near vision. FineVision and PanOptix provided significantly better intermediate vision than LISA tri at both 80 cm and 60 cm testing distance. FineVision had better near visual outcomes than PanOptix and LISA tri. Patient satisfaction was high in all 3 trifocal IOLS
Lenses, Intraocular
;
Vision, Ocular
8.Development and application of optogenetic tools.
Qiyao WEI ; Chenchen XU ; Meiyan WANG ; Haifeng YE
Chinese Journal of Biotechnology 2019;35(12):2238-2256
Dynamic variations of the cell microenvironment can affect cell differentiation, cell signaling pathways, individual growth, and disease. Optogenetics combines gene-encoded protein expression with optical controlling, and offers a novel, reversible, non-invasive and spatiotemporal-specific research tool to dynamically or reversibly regulate cell signaling pathways, subcellular localization and gene expression. This review summarizes the types of optogenetic components and the involved cellular signaling pathways, and explores the application and future prospects of the light-controlled cell signaling pathways.
Cell Differentiation
;
Light
;
Optogenetics
;
Proteins
;
Signal Transduction
9.Application of PRVEP Waveform Amplitude Ratio to Evaluate Visual Acuity and Its Forensic Significance.
Xiao Ying YU ; Si Lei TAN ; Wei Yi TANG ; Jie Min CHEN ; Meng WANG ; Rui Jue LIU ; Wen Tao XIA
Journal of Forensic Medicine 2019;35(4):402-405
Objective To research the correlation between the visual acuity ratio and pattern reversal visual evoked potential (PRVEP) P100 waveform amplitude ratio of both eyes. Methods Forty-seven volunteers were selected, and the visual chart visual acuity of both eyes was measured. The visual acuity ratio of the eye with poor vision to the eye with better vision was calculated by five grade notation method. The amplitudes of P100 waveforms of both eyes were recorded respectively by using black-and-white checkerboard PRVEP and chosing 1°, 15' stimulating visual angle, and the ratio of amplitudes between the two eyes was also calculated. SPSS 20.0 software was used to analyze the correlation between the visual acuity ratio and the ratio of P100 waveform amplitudes between the two eyes. Return test and linear regression analysis with the binocular ratio of P100 waveform amplitudes as the independent variable (x) and the binocular visual acuity ratio as the dependent variable (y) were made. Results There was a positive correlation between the binocular visual acuity ratio and the ratio of P100 waveform amplitudes under 15' stimulating visual angle (Pearson correlation coefficient was 0.62, P=0.000). The fitting linear regression equation was y=0.090 x+0.846 (F=20.954, P=0.000). There was no significant correlation between the binocular ratio of visual acuity and the binocular ratio of P100 waveform amplitudes under 1° stimulating visual angle (P>0.05). Results of return test showed that there was no statistical significance in the difference between visual acuity estimated by equation and actual detected visual acuity. Conclusion In forensic appraisal of monocular injury, fitting linear regression equation of binocular visual acuity ratio and the binocular ratio of P100 waveform amplitudes under 15' stimulating visual angle, is helpful for visual acuity level estimation of the injured eye to some extent.
Evoked Potentials, Visual
;
Eye/physiopathology*
;
Humans
;
Regression Analysis
;
Vision, Ocular
;
Visual Acuity
10.Study on the Imaging Quality Evaluation of Aspheric Intraocular Lenses.
Qin FENG ; Hong LU ; Yongjie LUO ; Jie LI ; Ting SONG
Chinese Journal of Medical Instrumentation 2018;42(6):446-448
The article is to study the objective evaluation method of the imaging quality of aspheric intraocular lens with different design concepts by establishing the model eye which is close to the actual corneal spherical aberration characteristics. Combined with the research data of corneal spherical aberration, the simulated cornea corresponding to Zernike c(4,0) coefficient 0.00 μm, 0.10 μm, 0.20 μm and 0.28 μm was established respectively. The optical quality of the measured simulated corneal lenses basically reached the theoretical design effect, and the deviation between the MTF value and the theoretical design value was equivalent to the MTF test repeatability. The establishment of model eye for artificial lens provides a research tool for the evaluation of aspheric intraocular lens imaging quality.
Cornea
;
Lens Implantation, Intraocular
;
Lenses, Intraocular
;
standards
;
Quality Control
;
Vision, Ocular


Result Analysis
Print
Save