1.Mechanism study on S-allylmercaptocysteine promoting CD8+T cell killing function
Chinese Archives of Otolaryngology-Head and Neck Surgery 2024;31(2):74-78
OBJECTIVE To investigate the effect of SAMC on the killing function of CD8+T cells against nasopharyngeal carcinoma cells and its mechanism.METHODS HK-1 and C666-1 are divided into 0,25,50,and 100 mol/L SAMC group,Western blot was used to detcet PD-L1 expression in tumor cells.CD8+T cells were co-cultured with HK-1 and C666-1 cells in a ratio of 10∶1,and 0,25,50,and 100 μmol/L SAMC were added and detect the killing ability of CD8+T on HK-1 and C666-1.ELISA was used to detect INF-γ and TNF-α concentration.Construct a subcutaneous transplant tumor model of nasopharyngeal HK-1 cells,and divide it into a control group,CD8+T cell group,SAMC group,and SAMC+CD8+T cell group.The tumor volume was measured during treatment in each group of mice.Western blot was used to detect the expression of PD-L1 in the tumor tissue,ELISA was used to detect INF-γ and TNF-α concentration of mouse serum.RESULTS Compared to 0 μmol/L SAMC group,the expression of PD-L1 in 25,50,100μmol/L SAMC group were significantly downregulated(P<0.05).Compared to 0 μmol/L SAMC+CD8+T group,the INF-γ and TNF-α concentration were significantly increased in 25,50,100 μmol/L SAMC+CD8+T group,the lysis rates of HK-1 and C666-1 cells were significantly increased.Compared with the control group,the tumor volume and weight in the CD8+T cell group and SAMC+CD8+T cell group were significantly reduced(P<0.05),the concentration of INF-γ and TNF-α were significantly increased.Compared with the CD8+T cell group,the tumor volume and weight in the SAMC+CD8+T cell group mice significantly decreased(P<0.05),while the serum INF-γ and TNF-α concentration significantly increased(P<0.05),and the expression of PDL-1 in tumor tissue was significantly downregulated(P<0.01).CONCLUSION SAMC can promote the killing function of CD8+T cells by inhibiting the expression of PD-L1 in human nasopharyngeal carcinoma cells.
2.Healthcare-associated infection and pathogen spectrum in neonatal inten-sive care unit:a 5-year single-center study
Yan-Min LI ; Rui-Min ZHANG ; Li-Li PING ; Li-Na ZHAI ; Xiao-Li ZHANG ; Jun-Yue HAN
Chinese Journal of Infection Control 2024;23(2):195-200
Objective To understand the spectrum and changes of pathogens causing healthcare-associated infec-tion(HAI)in neonatal intensive care unit(NICU).Methods Clinical medical records of neonates with HAI in a hospital from January 2018 to December 2022 were collected,spectrum of pathogens causing HAI were and analyzed retrospectively.Results A total of 7 597 hospitalized neonates were investigated,and 240 of whom had 263 cases of HAI,with an HAI incidence of 3.16%and healthcare-associated case infection incidence of 3.46%.96 cases(36.50%)were bloodstream infection,70(26.62%)were respiratory system infection,and 57(21.67%)were in-fection without clear sites.A total of 170 pathogens were detected from specimens,78(45.88%)of which were Gram-positive bacteria,with Staphylococcus spp.accounting for the highest proportion,78(45.88%)were Gram-negative bacteria,mainly Klebsiella pneumoniae,and 14(8.24%)were fungi.The detection rate of Gram-negative bacteria showed an upward trend from 2018 to 2022(P<0.01).Conclusion The majority of HAI in NICU is bloodstream infection.In recent years,the detection rate of Gram-negative bacteria has been increasing year by year,and it is necessary to streng-then the prevention and control of HAI in clinical practice.
3.Research on Electrochemical Chemical Oxygen Demand Sensor
Shan YUN ; Lei WANG ; Li-Guo WAN ; Zhen-Yu PENG ; Hong-Chang WANG ; Jun-Feng ZHAI ; Shao-Jun DONG
Chinese Journal of Analytical Chemistry 2024;52(9):1298-1306
An electrochemical chemical oxygen demand(COD)sensor was proposed based on a FTO/TiO2/PbO2 electrode and a thin-layer electrochemical cell.The FTO/TiO2/PbO2 electrode was characterized by X-ray photoelectronic spectroscopy(XPS),X-ray diffraction(XRD)spectroscopy and electrochemical technique,and the results indicated that the rapid decrease in the output signals of the electrochemical COD sensor could be attributed to oxidation of PbSO4 occurring on the surface of FTO/TiO2/PbO2 electrode.The PbO2 deposition time and concentration of Na2SO4 were further optimized and then the electrochemical COD sensor was challenged by real samples including laker water sample,river water sample and wastewater sample.The evolution trend of signals of the electrochemical COD sensor in response to lake and river water samples was identical with that obtained with the standard method(HJ/T399-2007,Water quality-determination of the chemical oxygen demand-fast digestion-spectrophotometric method).The electrochemical COD sensor exhibited significant increase in the signal intensity after the samples were switched from lake water to wastewater sample,and a mean value of 32.5 mg/L with relative standard deviation(RSD)of 6.8%were obtained after measuring 45 times the wastewater with COD value of 30 mg/L under a sampling interval of 400 s.The as-prepared electrochemical COD sensor possessed good promise in regular monitoring of COD,discharge of wastewater and industrial process control,with advantages such as a small sampling interval,mild reaction conditions and no requirement of toxic and harmful chemical reagents.
4.Reliability and Validity of the Life History of Aggression-Chinese Version in Schizophrenia Patients Assessment
Xia-Can CHEN ; Qin YANG ; Qin-Ting ZHANG ; Ai-Li OUYANG ; Jia-Jun XU ; Rui YANG ; Zi-Ye WANG ; Jin-Hui ZHAI ; Yan LI ; Xiao-Rong QIN ; Jun-Mei HU
Journal of Forensic Medicine 2024;40(4):352-358
Objective To provide a longitudinal evaluation tool based on the frequency of aggressive be-havior for the aggression assessment of schizophrenia patients.Methods The Life History of Aggression was translated and revised to form the Life History of Aggression-Chinese Version(LHA-CV)based on 369 patients diagnosed with schizophrenia in the Chengdu community and compulsory medical insti-tution.The reliability of LHA-CV was analyzed by means of split-half reliability,test-retest reliability and inter-evaluator consistency.The validity was analyzed by item analysis,construct validity and crite-rion validity.Results Item analysis found that LHA-CV had good homogeneity and discriminant validity.Exploratory factor analysis found that the Kaiser-Meyer-Olkin(KMO)test value was 0.80,and the Bartlett's sphericity test χ2=1203.46(P<0.05),and it revealed four factors including non-physical ag-gression,physical aggression,self-directed aggression and antisocial behavior/consequences.The factor loadings for all 11 items were greater than 0.40.Confirmatory factor analysis was performed on the factor model,Chi-square degree of freedom(χ2/df)was 3.61,root mean square error of approxima-tion(RMSEA)was 0.07,goodness-of-fit index(GFI)was 0.92,comparative fit index(CFI)was 0.90,incremental fit index(IFI)was 0.90,and the discriminant validity of each factor was good.The criterion validity test showed the total score of LHA-CV was positively correlated with the aggressive behavior level of MacArthur Community Violence Instrument,the total score of Buss-Perry Aggression Scale,and the score of Antisocial Personality Disorder Subscale of Personality Diagnostic Question-naire-4th Edition Plus(PDQ-4+_ASPD,P<0.05).The Cronbach's α coefficient of non-physical aggres-sion,physical aggression,self-directed aggression,antisocial behavior/consequences and LHA-CV total score were 0.82,0.73,0.74,0.56 and 0.79,respectively.The test-retest reliability,Spearman-Brown split-half reliability and intra-class correlation coefficient of LHA-CV total score were 0.82(P<0.05),0.66 and 0.99,respectively.Conclusion LHA-CV has good reliability and validity,and can be used as an evaluation tool for longitudinally assessing aggressive behavior in schizophrenia patients.
5.Therapeutic results of three-dimensional aortic valve anatomic repair for regurgitant bicuspid aortic valve
Jun LI ; Chunsheng WANG ; Zheng ZUO ; Hao LAI ; Lili DONG ; Kai ZHU ; Junyu ZHAI ; Yongxin SUN ; Wenjun DING ; Tao HONG
Chinese Journal of Surgery 2024;62(11):1024-1031
Objective:To explore the surgical technique and results of three-dimensional aortic valve anatomic repair for bicuspid aortic valve (BAV) with aortic regurgitation (AR).Methods:This is a retrospective case series study. From August 2021 to December 2023, 130 consecutive patients with BAV-AR underwent aortic valve anatomic repair at the Department of Cardiothoracic Surgery, Zhongshan Hospital, Fudan University,and the data were retrospectively analyzed. There were 115 males and 15 females, aged (38.6±11.7) years (range: 15 to 67 years). All patients received modified aortic root reconstruction, to do three-dimensional root remodeling, including the basal ring, sinus of Valsalva and sino-tubular junction simultaneously. Perioperative and follow-up data were collected and analyzed. Comparisons between groups were performed using independent samples t-test, Wilcoxon paired signed-rank test, or χ2 test. Results:No patient transferred to valve replacement during the operation. The cardiopulmonary bypass time ( M(IQR)) was 109(34) minutes (range:67 to 247 minutes), and the aortic cross-clamp time was 76(26) minutes (range: 32 to 158 minutes). Preoperative transesophageal echocardiography showed 123 patients (94.6%) presented with moderate or severe regurgitation. Immediately postoperative transesophageal echocardiography showed no regurgitation in 22 patients (16.9%), trace regurgitation in 81 patients (62.3%) and mild regurgitation in 27 patients (20.8%). Follow up was completed in all patients, with a follow-up of 5.5(9.4) months (range: 0.1 to 27.6 months). No mortality was observed during follow-up. Echocardiography was obtained in 112 patients at the latest follow-up, including no regurgitation in 4 patients (3.6%), trace regurgitation in 58 patients (51.8%), mild regurgitation in 45 patients (40.2%), moderate regurgitation in 4 patients (3.6%), and severe regurgitation in 1 patient (0.9%). Conclusion:For patients with BAV-AR who have good valve quality and no severe aortic sinus dilation, the recent outcomes of three-dimensional anatomical repair technique, focusing on overall remodeling of the aortic root, are satisfactory.
6.Therapeutic results of three-dimensional aortic valve anatomic repair for regurgitant bicuspid aortic valve
Jun LI ; Chunsheng WANG ; Zheng ZUO ; Hao LAI ; Lili DONG ; Kai ZHU ; Junyu ZHAI ; Yongxin SUN ; Wenjun DING ; Tao HONG
Chinese Journal of Surgery 2024;62(11):1024-1031
Objective:To explore the surgical technique and results of three-dimensional aortic valve anatomic repair for bicuspid aortic valve (BAV) with aortic regurgitation (AR).Methods:This is a retrospective case series study. From August 2021 to December 2023, 130 consecutive patients with BAV-AR underwent aortic valve anatomic repair at the Department of Cardiothoracic Surgery, Zhongshan Hospital, Fudan University,and the data were retrospectively analyzed. There were 115 males and 15 females, aged (38.6±11.7) years (range: 15 to 67 years). All patients received modified aortic root reconstruction, to do three-dimensional root remodeling, including the basal ring, sinus of Valsalva and sino-tubular junction simultaneously. Perioperative and follow-up data were collected and analyzed. Comparisons between groups were performed using independent samples t-test, Wilcoxon paired signed-rank test, or χ2 test. Results:No patient transferred to valve replacement during the operation. The cardiopulmonary bypass time ( M(IQR)) was 109(34) minutes (range:67 to 247 minutes), and the aortic cross-clamp time was 76(26) minutes (range: 32 to 158 minutes). Preoperative transesophageal echocardiography showed 123 patients (94.6%) presented with moderate or severe regurgitation. Immediately postoperative transesophageal echocardiography showed no regurgitation in 22 patients (16.9%), trace regurgitation in 81 patients (62.3%) and mild regurgitation in 27 patients (20.8%). Follow up was completed in all patients, with a follow-up of 5.5(9.4) months (range: 0.1 to 27.6 months). No mortality was observed during follow-up. Echocardiography was obtained in 112 patients at the latest follow-up, including no regurgitation in 4 patients (3.6%), trace regurgitation in 58 patients (51.8%), mild regurgitation in 45 patients (40.2%), moderate regurgitation in 4 patients (3.6%), and severe regurgitation in 1 patient (0.9%). Conclusion:For patients with BAV-AR who have good valve quality and no severe aortic sinus dilation, the recent outcomes of three-dimensional anatomical repair technique, focusing on overall remodeling of the aortic root, are satisfactory.
7.Design of automatic urine volume detection and collection device
Yan CHEN ; De-Zhao ZHAI ; Xiao-Quan ZHANG ; Fu-Long LIU ; Xiao-Tao ZHANG ; Yong-Mei ZHANG ; Wei CEHN ; Fang ZHANG ; Guo-Hui WU ; Jun DENG ; Dan LI
Chinese Medical Equipment Journal 2024;45(4):66-69
Objective To develop an automatic urine volume detection and collection device to solve the problems of routine urine test.Methods An automatic urine volume detection and collection device was developed with the components of a main control system,a detection system,a prompting system and a grasping and moving system.The main control system consisted of two STM32 microcontrollers and a reset switch;the detection system was made up of a weighing module,an infrared module and indicator lights,which had its urine volume automatic detection algorithm developed based on the Keil5 platform;the prompting system realized voice broadcasting through the voice module fixed on the back panel of the box;the grasping and moving system was composed of a rail drive motor(86CM stepper motor),a photoelectric switch and a motorized gripper.Results The device developed tested urine samples with an accuracy of 99.44%,and could collect qualified samples automatically and quickly.Conclusion The device developed detects urine volume and collects samples automatically,and enhances the accuracy and efficiency of urine examination.[Chinese Medical Equipment Journal,2024,45(4):66-69]
8.Clinical Analysis of Philadelphia Chromosome-Like Acute Lymphoblastic Leukemia in Children
Tian-Dan LI ; Shao-Yan HU ; Zong ZHAI ; Guang-Hua CHEN ; Jun LU ; Hai-Long HE ; Pei-Fang XIAO ; Jie LI ; Yi WANG
Journal of Experimental Hematology 2024;32(1):78-84
Objective:To explore the clinical characteristics,molecular characteristics,treatment and prognosis of pediatric Philadelphia chromosome-like acute lymphoblastic leukemia(Ph-like ALL)with a therapeutic target.Methods:A total of 27 patients of Ph-like ALL with targeted drug target were initially diagnosed in Children's Hospital of Soochow University from December 2017 to June 2021.The data of age,gender,white blood cell(WBC)count at initial diagnosis,genetic characteristics,molecular biological changes,chemotherapy regimen,different targeted drugs were given,and minimal residual disease(MRD)on day 19,MRD on day 46,whether hematopoietic stem cell transplantation(HSCT)were retrospective analyed,and the clinical characteristics and treatment effect were summarized.Survival analysis was performed by Kaplan-Meier method.Results:The intensity of chemotherapy was adjusted according to the MRD level during induced remission therapy in 27 patients,10 patients were treated with targeted drugs during treatment,and 3 patients were bridged with HSCT,1 patient died and 2 patients survived.Among the 24 patients who did not receive HSCT,1 patient developed relapse,and achieved complete remission(CR)after treatment with chimeric antigen receptors T cells(CAR-T).The 3-year overall survival,3-year relapse-free survival and 3-year event-free survival rate of 27 patients were(95.5±4.4)%,(95.0±4.9)%and(90.7±6.3)%respectively.Conclusion:Risk stratification chemotherapy based on MRD monitoring can improve the prognosis of Ph-like ALL in children,combined with targeted drugs can achieve complete remission as soon as possible in children whose chemotherapy response is poor,and sequential CAR-T and HSCT can significantly improve the therapeutic effect of Ph-like ALL in children whose MRD is continuously positive during induced remission therapy.
9.Validation study of a novel diaphragmatic excursion measurement method: evaluation of diaphragmatic excursion by phased-array probe in hepato-renal/spleno-renal section
Junyu MA ; Shanshan ZHAI ; Xiaocong SUN ; Chen LI ; Jun DUAN
Chinese Critical Care Medicine 2024;36(7):740-744
Objective:To investigate the accuracy and reproducibility of diaphragmatic excursion (DE) measurements through hepato-renal/spleno-renal section as a novel method for assessing diaphragmatic function.Methods:Twelve healthy participants were recruited. Each participant underwent DE measurements performed by four operators with varying levels of experience using traditional methods (liver/spleen section) and novel methods (hepato-renal/spleno-renal section), respectively. Among them, two experienced operators were critical care clinicians, and diaphragmatic ultrasound was performed in more than 50 cases. The other two inexperienced operators were respiratory therapists, with less than 10 cases of diaphragmatic ultrasound operations, who received a 2-hour theoretical and operational training before the study. Operators initially used the conventional method with a 1.5-6.0 MHz convex probe in M-mode, placing the sampling line perpendicular to the diaphragm at the point of maximum excursion, and the liver/spleen section DE was determined during normal breathing of participant. Then, they used the novel method with a 1.6-4.5 MHz phased array probe to observe diaphragmatic movement cranio-caudally along the mid-axillary line, employing anatomic M-mode with the sampling line placed perpendicular to the diaphragm at the level of the renal midpoint, and the DE of the hepato-renal/spleno-renal section was measured during normal breathing. The liver and hepato-renal sections were used to assess the right diaphragm, and spleen and spleno-renal sections were used to assess the left diaphragm. Correlation analysis of DE measurements from different sections was conducted using the Deming method, while consistency was assessed using the Bland-Altman method. The consistency of clinical acceptability was defined as the absence of fixed and proportional bias, with a difference of two standard deviations less than 40% of the mean measurement value. Percentage consistency limit = two standard deviations of the differences between measurements/mean measurement value×100%.Results:Four operators performed image scans of DE in all four sections for each of the twelve subjects, with a high DE acquisition rate of 100% (48/48) for hepato-renal and spleno-renal sections, followed by the liver section [91.7% (44/48)] and the spleen section [66.7% (32/48)], particularly for the left diaphragm assessment, where the DE acquisition rate of spleno-renal section was significantly higher than that of traditional spleen section ( P < 0.01). The overall measurement results showed that no significant difference was found in DE determined via the hepato-renal and spleno-renal sections using the novel method (cm: 1.64±0.10 vs. 1.55±0.14, P > 0.05), and they were significantly higher than those determined via the conventional liver and spleen sections (cm: hepato-renal section vs. liver section was 1.64±0.10 vs. 1.44±0.09, spleno-renal section vs. spleen section was 1.55±0.14 vs. 1.09±0.14, both P < 0.01). Correlation analysis revealed good correlations of DE between hepato-renal section and spleno-renal section, between liver section and hepato-renal section, between liver section and spleno-renal section ( r values were 0.62, 0.59, and 0.42, all P < 0.01). Consistency analysis showed that the consistency in DE between hepato-renal section and spleno-renal section, as well as between liver section and hepato-renal section was good (both % consistency limits < 40%). However, the DE measured in the spleen section were not correlated with the other three sections, and there was no inconsistency (all % consistency limits > 40%). There was no statistically significant difference in DE measured by the four operators in the liver, spleen, hepato-renal, and spleno-renal sections (cm: 1.49±0.34, 1.44±0.37, 1.43±0.30, and 1.40±0.27 in liver section; 1.10±0.36, 1.05±0.18, 1.09±0.22, and 1.06±0.26 in spleen section; 1.67±0.43, 1.57±0.34, 1.63±0.32, and 1.66±0.36 in hepato-renal section; 1.45±0.33, 1.48±0.34, 1.50±0.24, and 1.65±0.26 in spleno-renal section; all P > 0.05). According to the clinically acceptable range of consistency limits, the DE measured by the four operators in all four sections showed good consistency (all % consistency limits < 40%). Conclusion:The novel method of measuring DE through hepato-renal/spleno-renal sections is accurate, highly reproducible, and has a high acquisition rate, serving as a viable alternative to the conventional method involving the liver/spleen section.
10.Research progress on neurobiological mechanisms underlying antidepressant effect of ketamine
Dong-Yu ZHOU ; Wen-Xin ZHANG ; Xiao-Jing ZHAI ; Dan-Dan CHEN ; Yi HAN ; Ran JI ; Xiao-Yuan PAN ; Jun-Li CAO ; Hong-Xing ZHANG
Chinese Pharmacological Bulletin 2024;40(9):1622-1627
Major depressive disorder(MDD)is a prevalent con-dition associated with substantial impairment and low remission rates.Traditional antidepressants demonstrate delayed effects,low cure rate,and inadequate therapeutic effectiveness for man-aging treatment-resistant depression(TRD).Several studies have shown that ketamine,a non-selective N-methyl-D-aspartate receptor(NMDAR)antagonist,can produce rapid and sustained antidepressant effects.Ketamine has demonstrated efficacy for reducing suicidality in TRD patients.However,the pharmaco-logical mechanism for ketamine's antidepressant effects remains incompletely understood.Previous research suggests that the an-tidepressant effects of ketamine may involve the monoaminergic,glutamatergic and dopaminergic systems.This paper provides an overview of the pharmacological mechanism for ketamine's anti-depressant effects and discuss the potential directions for future research.

Result Analysis
Print
Save
E-mail