1.Field-driven medical micro-robots:application prospect of continuously optimizing material preparation process
Wenqian XIAO ; Hongjuan HAN ; Haocheng YANG ; Bo LI ; Binyan HE
Chinese Journal of Tissue Engineering Research 2025;29(10):2097-2104
BACKGROUND:Micro-robots have the characteristics of small size,flexibility,and strong targeting,and can complete complex tasks in a single or clustered manner in a narrow environment.With the continuous optimization of materials,preparation processes,and driving approaches,they have shown increasingly important application value in the field of biomedicine. OBJECTIVE:To analyze the application of field-driven micro-robots in medical field and to look forward to their application prospect. METHODS:Using"microrobots,nanorobots,drivers,biomedical,medical"as Chinese keywords and"microrobots,micro-robots,nanorobots,micromachine,microswimmer,medical"as English keywords,WanFang Data and PubMed databases were searched,respectively.The search time range was from January 2010 to January 2024,and a small number of long-term articles were included.Through reading the titles and preliminarily screening the abstracts,the repetitive studies,low-quality journals,and irrelevant literature were excluded.After reading the entire text,66 papers were finally included for review. RESULTS AND CONCLUSION:Field-driven medical micro-robots mainly include magnetic,optical,thermal,ultrasonic,and multi-mixed factor-driven robots.Field-driven robots have been used in intestinal diagnosis,drug targeting therapy,and stem cell therapy.Medical micro-robots are currently only used in a small number of clinical applications,but most of which are still in the theoretical and experimental stages.Medical micro-robots will face many challenges in future,such as large-scale preparation,precise control of micro-robots,recycling or degradation in vivo,whether the materials used will cause adverse reactions to the human body,and the related minimally invasive medical procedures.
2.Five new triterpenoid saponins from the kernels of Momordica cochinchinensis
Ru DING ; Jia-qi WANG ; Yi-yang LUO ; Yong-long HAN ; Xiao-bo LI ; Meng-yue WANG
Acta Pharmaceutica Sinica 2025;60(2):442-448
Five saponins were isolated from the kernels of
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.The Invariant Neural Representation of Neurons in Pigeon’s Ventrolateral Mesopallium to Stereoscopic Shadow Shapes
Xiao-Ke NIU ; Meng-Bo ZHANG ; Yan-Yan PENG ; Yong-Hao HAN ; Qing-Yu WANG ; Yi-Xin DENG ; Zhi-Hui LI
Progress in Biochemistry and Biophysics 2025;52(10):2614-2626
ObjectiveIn nature, objects cast shadows due to illumination, forming the basis for stereoscopic perception. Birds need to adapt to changes in lighting (meaning they can recognize stereoscopic shapes even when shadows look different) to accurately perceive different three-dimensional forms. However, how neurons in the key visual brain area in birds handle these lighting changes remains largely unreported. In this study, pigeons (Columba livia) were used as subjects to investigate how neurons in pigeon’s ventrolateral mesopallium (MVL) represent stereoscopic shapes consistently, regardless of changes in lighting. MethodsVisual cognitive training combined with neuronal recording was employed. Pigeons were first trained to discriminate different stereoscopic shapes (concave/convex). We then tested whether and how light luminance angle and surface appearance of the stereoscopic shapes affect their recognition accuracy, and further verify whether the results rely on specify luminance color. Simultaneously, neuronal firing activity of neurons was recorded with multiple electrode array implanted from the MVL during the presentation of difference shapes. The response was finally analyzed how selectively they responded to different stereoscopic shapes and whether their selectivity was affected by the changes of luminance condition (like lighting angle) or surface look. Support vector machine (SVM) models were trained on neuronal population responses recorded under one condition (light luminance angle of 45°) and used to decode responses under other conditions (light luminance angle of 135°, 225°, 315°) to verify the invariance of responses to different luminance conditions. ResultsBehavioral results from 6 pigeons consistently showed that the pigeons could reliably identify the core 3D shape (over 80% accuracy), and this ability wasn’t affected by changes in light angle or surface appearance. Statistical analysis of 88 recorded neurons from 6 pigeons revealed that 83% (73/88) showed strong selectivity for specific 3D shapes (selectivity index>0.3), and responses to convex shapes were consistently stronger than to concave shapes. These shape-selective responses remained stable across changes in light angle and surface appearance. Neural patterns were consistent under both blue and orange lighting. The decoding accuracy achieves above 70%, suggesting stable responses under different conditions (e.g., different lighting angles or surface appearance). ConclusionNeurons in the pigeon MVL maintain a consistent neural encoding pattern for different stereoscopic shapes, unaffected by illumination or surface appearance. This ensures stable object recognition by pigeons in changing visual environments. Our findings provide new physiological evidence for understanding how birds achieve stable perception (“invariant neural representations”) while coping with variations in the visual field.
9.Clinical Observation on the Thumb-tack Needling for Subcutaeous Embedding Combined with Joint Mobilization in the Treatment of Post-stroke Shoulder-Hand Syndrome
Jing-Xia CHEN ; Xiao-Han YUAN ; Hong-Xing LIU ; Bo-Wen LI ; Mei-Yu JIANG ; Ya-Nan ZHAO ; Wen-Feng SONG
Journal of Guangzhou University of Traditional Chinese Medicine 2024;41(3):689-695
Objective To observe the clinical efficacy of thumb-tack needling for subcutaeous embedding combined with joint mobilization in the treatment of post-stroke shoulder-hand syndrome.Methods A total of 80 patients with post-stroke shoulder-hand syndrome were randomly divided into a treatment group and a control group,with 40 patients in each group.Both groups were given arthrocentesis,the control group was given ordinary acupuncture on the basis of arthrocentesis,and the treatment group was combined with thumb-tack needling for subcutaeous embedding.One course of treatment was 4 weeks and a total of 4 weeks of treatment was given.After 1 month of treatment,the clinical efficacy of the two groups was evaluated.The changes of Visual Analogue Scale(VAS)of pain scores and simplified Fugl-Meyer Assessment(FMA)scores,as well as the pain-free passive forward flexion and abduction of the shoulder joint of the affected limb were observed before and after treatment.The Simple Quality of Life Scale(SF-36)scores of the patients in the two groups were compared after treatment.The safety and the occurrence of adverse reactions in the two groups were also evaluated.Results(1)The total effective rate was 95.00%(38/40)in the treatment group and 80.00%(32/40)in the control group.The efficacy of the treatment group was superior to that of the control group,and the difference was statistically significant(P<0.05).(2)After treatment,the VAS scores and upper extremity FMA scores of the patients in the two groups were significantly improved(P<0.05),and the treatment group was significantly superior to the control group in improving the VAS scores and upper extremity FMA scores,and the differences were statistically significant(P<0.05).(3)After treatment,the joint mobility of patients in the two groups were significantly improved(P<0.05),and the improvement of shoulder joint movement in the treatment group was superior to that in the control group,and the difference was statistically significant(P<0.05).(4)After treatment,the SF-36 Quality of Life Scale scores of the treatment group were significantly superior to those of the control group in terms of physical function,psychological function,emotional health,and social function levels,and the difference was statistically significant(P<0.05).(5)There was no significant difference in the incidence of adverse reactions between the treatment group and the control group(P>0.05).Conclusion Thumb-tack needling for subcutaeous embedding combined with joint mobilization exert certain effect in the treatment of post-stroke shoulder-hand syndrome.It can significantly improve the pain symptoms of patients,thus improving their quality of life,and the clinical effect is remarkable.
10.Protective effect and mechanism of acellular nerve allografts combined with electroacupuncture on spinal ganglia in rats with sciatic nerve injury
Ze-Yu ZHOU ; Yun-Han MA ; Jia-Rui LI ; Yu-Meng HU ; Bo YUAN ; Yin-Juan ZHANG ; Xiao-Min YU ; Xiu-Mei FU
Acta Anatomica Sinica 2024;55(2):143-149
Objective To investigate the protective effect and mechanism of acellular nerve allografts(ANA)combined with electroacupuncture on spinal ganglia in rats with sciatic nerve injury(SNI).Methods Totally 50 male adult SD rats were randomly selected for this experiment.Ten rats were prepared for the ANA.Forty male SD rats were randomly divided into normal group,model group,ANA group and combinational group,with 10 rats in each group.The SNI model was established by cutting off the nerves 10 mm at the 5 mm on the inferior border of piriformis after separating the right sciatic nerves.The rats in the ANA group were bridged with ANA to the two broken ends of injured nerves.The rats in the combinational group were treated with electroacupuncture 2 days after ANA bridging,Huantiao(GB30)and Yanglingquan(GB34)were performed as the acupuncture points,each electroacupuncture lasted 15 minutes and 7 days as a course of treatment,4 courses in all.Sciatic nerve conduction velocity was measured by electrophysiology to evaluate the regeneration of damaged axons.Morphology of spinal ganglia was observed by Nissl staining.The expression of nerve growth factor(NGF)and brain-derived neurotrophic factor(BDNF)were detected by Western blotting and immunofluorescent staining.Results Compared with the normal group,the sciatic nerve conduction velocity in model group decreased significantly(P<0.01),Nissl bodies in neurons of spinal ganglia were swollen and dissolved,with incomplete structure and the number decreased dramatically(P<0.01),while the level of NGF and BDNF also decreased significantly(P<0.01).Compared with the model group,the sciatic nerve conduction velocity in ANA and combinational groups strongly increased(P<0.01),the damage of Nissl bodies in neurons of spinal ganglia reduced and the number obviously increased(P<0.01),the level of NGF and BDNF increased considerably(P<0.01).Compared with the ANA group,the sciatic nerve conduction velocity in combinational group increased significantly(P<0.01),the morphology of Nissl bodies in neurons of spinal ganglia were more regular and the number increased(P<0.01),moreover,the level of NGF also increased significantly(P<0.01).Conclusion ANA combined with electroacupuncture can enhance the sciatic nerve conduction velocity,improve the morphology of neurons in spinal ganglia and play a protective effect on spinal ganglia.The mechanism can be related to the higher expression of NGF and BDNF proteins,especially the expression of NGF protein.

Result Analysis
Print
Save
E-mail