1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.A retrospective analysis of the assessment results of external quality control of fluoride testing laboratories in national endemic disease prevention and control institutions
Xiaohong JI ; Wei WANG ; Lijun ZHAO ; Lin GAO ; Liaowei WU ; Cheng LI ; Jian WANG ; Junrui PEI ; Yanhui GAO
Chinese Journal of Endemiology 2024;43(2):141-147
Objective:To analyze the external quality control assessment results of fluoride testing laboratories in endemic disease prevention and control institutions nationwide from 2006 to 2023, investigate the quality control capabilities of these laboratories in various provinces, prefectures, cities, and counties nationwide, and ensure the accuracy and reliability of surveillance data on endemic fluorosis nationwide.Methods:Using retrospective analysis, the external quality control assessment results of all participating fluoride testing laboratories of national endemic disease prevention and control institutions from 2006 to 2023 were summarized and analyzed. The assessment results from 2006 to 2008 were tested for outliers using Grubbs method, homogeneity of variance using Cochran method, excluding the assessment data of unqualified laboratories, calculating the total mean and total standard deviation, Z-score method was used to test the assessment of laboratories, and statistical analysis and judgment were done when the result of │Z│ < 3. The assessment results from 2009 - 2023 were obtained from all laboratories. In 2010, two tests were conducted in the first and second half of the year, and the Z-ratio scores of each laboratory were calculated using robust statistics. When │Z│≤2, the assessment was qualified; when 2 < │Z│ < 3, the assessment was basically qualified; when│Z│≥3, the assessment was unqualified, and the consensus value came from all participating laboratories in the assessment.Results:From the beginning of quality control operation in 2006 to 2023, the number of laboratories participated in external quality control assessments had significantly increased. The number of laboratories participated in water fluoride assessment increased from 30 in 2006 to 1 277 in 2023, and the number of laboratories participated in urine fluoride assessment increased from 29 to 497. The number of laboratories participated in the brick tea fluorine assessment had increased from 43 in 2014 to 193 in 2023. The assessment results showed that when │Z│ < 3, the total qualified rate of fluoride external quality control in fluoride testing laboratories of national endemic disease control institutions was 95.2%, with the lowest being 87.1% (27/31) in 2008 and the highest being 100.0% (394/394) in 2014. When │Z│≤2, the total feedback pass rate was 88.4%, with the lowest being 79.3% (288/363) in the first half of 2010 and the highest being 99.5% (392/394) in 2014. The assessment results showed that when │Z│ < 3, the total pass rate of urine fluoride external quality control in fluoride testing laboratories of national endemic disease control institutions was 98.0%, with the lowest being 86.2% (25/29) in 2006 and 2007, respectively, and the highest being 100.0% (68/68) in 2014. When │Z│≤2, the total qualification rate was 93.7%, with the lowest being 86.5% (64/74) in the second half of 2010 and the highest being 100.0% (68/68) in 2014. The assessment results showed that when│Z│ < 3, the total pass rate of extra-fluoride quality control of brick tea in fluoride testing laboratories of national endemic disease control institutions was 95.4%, with the lowest being 85.0% (164/193) in 2023, and the highest being 100.0% (43/43, 51/51, 79/79) in 2014, 2015 and 2016, respectively. When │Z│≤2, the total pass rate was 89.2%, with the lowest being 72.7% (32/44) in 2017 and the highest being 100.0% (43/43) in 2014. From 2009 to 2023, there were a total of 21 provincial-level laboratories that passed the water fluoride detection assessment, including 3 provinces where all prefecture level and county-level laboratories were qualified. The assessment results of urinary fluorine showed that there were 11 qualified provincial-level laboratories and 1 prefecture-level laboratory. From 2014 to 2023, the assessment results of brick-tea fluorine showed that there were 5 provincial-level laboratories that passed the tea fluorine testing assessment and no prefecture-level laboratory.Conclusions:Conclusion: From 2006 to 2023, the number of fluoride testing laboratories participating in external quality control assessment has increased year by year, and most provincial, municipal and county-level laboratories have good fluoride testing capabilities, which can meet the testing needs of endemic disease prevention and monitoring. For some laboratories with problems, targeted rectification should be carried out to improve the quality of detection, in order to provide better technical support for the monitoring of endemic fluorosis areas.
7.Application of the OmniLogTM microbial identification system in the detection of the host spectrum for wild-type plague phage in Qinghai Plateau
Cun-Xiang LI ; Zhi-Zhen QI ; Qing-Wen ZHANG ; Hai-Hong ZHAO ; Long MA ; Pei-Song YOU ; Jian-Guo YANG ; Hai-Sheng WU ; Jian-Ping FENG
Chinese Journal of Zoonoses 2024;40(1):21-25
The growth of three plague phages from Qinghai Plateau in two Yersinia pestis strains(plague vaccine strains EV76 and 614F)and four non-Yersinia pestis strains(Yersinia pseudotuberculosis PTB3,PTB5,Escherichia coli V517,and Yersinia enterocolitica 52302-2)were detected through a micromethod based on the OmniLogTM microbial identification system and by the drop method,to provide a scientific basis for future ecological studies and classification based on the host range.For plague vaccine strains EV76 and 614F,successful phage infection and subsequent phage growth were observed in the host bacte-rium.Diminished bacterial growth and respiration and a concomitant decrease in color were observed with the OmniLogTM mi-crobial identification system at 33 ℃ for 48 h.Yersinia pseudotuberculosis PTB5 was sensitive to Yersinia pestis phage 476,but Yersinia pseudotuberculosis PST5 was insensitive to phage 087 and 072204.Three strains of non-Yersinia pestis(Yersinia pseudotuberculosis PTB3,Escherichia coli V517,and Yersinia enterocolitica 52302-2)were insensitive to Yersinia pestis pha-ges 087,072204,and 476 showed similar growth curves.The growth of phages 476 and 087,as determined with the drop method,in two Yersinia pestis strains(plague vaccine strains EV76 and 614F)and four non-Yersinia pestis strains(Yersinia pseudotuberculosis PTB3,Escherichia coli V517,and Yersin-ia enterocolitica 52302-2)showed the same results at 37 ℃,on the basis of comparisons with the OmniLogTM microbial i-dentification system;in contrast,phages 072204 did not show plaques on solid medium at 37 ℃ with plague vaccine strains EV76 and 614F.Determination based on the OmniLogTM detection system can be used as an alternative to the traditional determination of the host range,thus providing favorable application val-ue for determining the interaction between the phage and host bacteria.
8.Chemical constituents from the leaves of Cyclocarya paliurus and their α-glucosidase inhibitory activities
Yong YANG ; Ting-Si GUO ; Min XIE ; Li-Hong TAN ; Wen-Chu LI ; Hao ZHENG ; Fei-Bing HUANG ; Yu-Pei YANG ; Wei WANG ; Yu-Qing JIAN
Chinese Traditional Patent Medicine 2024;46(3):834-842
AIM To study the chemical constituents from the leaves of Cyanocarya paliurus(Batalin)Iljinskaja and their α-glucosidase inhibitory activities.METHODS The 95%ethanol extract from the leaves of C.paliurus was isolated and purified by macroporous resin,silica gel,Sephadex LH-20,polyamide,C18 reversed-phase silica gel and semi-preparative HPLC,then the structures of obtained compounds were identified by physicochemical properties and spectral data.Their α-glucosidase inhibitory activities were evaluated by PNPG.RESULTS Fifteen compounds were isolated and identified as cyclopaloside C(1),cyclopaloside A(2),juglanosides E(3),vaccinin A(4),ent-murin A(5),kaempferol 3-O-α-L-rhamnopyranoside(6),kaempferol-3-O-β-D-glucopyranoside(7),kaempferol-3-O-β-D-glucuronide methyl ester(8),kaempferol-3-O-β-D-glucuronide ethyl ester(9),kaempferol-3-O-β-D-glucuronide butyl ester(10),quercetin-3-O-α-L-rhamnopyranoside(11)quercetin-3-O-β-D-glucopyranoside(12),quercetin-3-O-β-D-galactopyranoside(13),quercetin-3-O-β-D-glucuronide butyl ester(14),dihydrokaempferol(15).The IC50 value of total extracts ihibited α-glucosidase was(1.83±0.04)μg/mL,and the IC50 values of compounds 1,4-5 were(29.48±1.86),(0.50±0.07),(0.71±0.07)μmol/L,respectively.CONCLUSION Compound 1 is a new tetrahydronaphthalene glycoside.Compounds 4-5,8-10 and 14 are isolated from the leaves of C.paliurus for the first time.Compounds 4-5 are relatively rare flavonoid lignans with potential inhibitory activities against α-glucosidase.
9.Impact of different intestinal flushing methods on bacterial load and short-Term postoperative complications in colorec-tal NOSES surgery
Pei-Cheng LI ; Long LI ; Xin-Jian WANG
Chinese Journal of Current Advances in General Surgery 2024;27(10):773-778
Objective:To compare the effects of povidone-iodine pressurized retention en-ema irrigation and ordinary irrigation on bacterial load and postoperative complications in natural ori-fice specimen extraction surgery for colorectal cancer.Method:A total of 49 eligible colorectal cancer patients were prospectively analyzed,with 26 patients randomly assigned to the pressure retention enema group and 23 patients assigned to the ordinary irrigation group.Bacteriological load during surgery,postoperative inflammatory indexes,and short-term complications were compared between the two groups.Result:The pressure retention enema group exhibited significantly lower levels of intestinal bacteria compared to the ordinary irrigation group,with a statistically sig-nificant difference(P<0.05).Additionally,the pressure retention enema group had lower serum pro-calcitonin and C-reactive protein levels on the 1st and 4th days after surgery,compared to the ordi-nary irrigation group,with a statistically significant difference(P<0.05).Pressurized retention enema irrigation(OR:0.22,95%CI:0.06-0.85,P=0.028)was identified as a protective factor in reducing the incidence and severity of short-term postoperative complications.Conclusion:Povidone-iodine pressurized retention enema is an effective irrigation method that significantly reduces bacterial load during surgery,minimizes postoperative inflammatory reaction,and improves short-term clini-cal outcomes.
10.Effects of ginsenoside Rg3 on biobehavior of human gastric cancer SGC-7901 cells by regulating E2F1
Jian-Xin WANG ; Lin-Qian WANG ; Bo ZHU ; Pei SHI ; Yi-Chang SUN ; Li HAN
Chinese Pharmacological Bulletin 2024;40(5):853-858
Aim To explore the effect of ginsenoside Rg3 on the biological behavior of human gastric cancer SGC-7901 cells by regulating E2F1.Methods MTT assay was used to determine the effect of ginsenoside Rg3(0,80,160,320 μmol·L-1)on cell prolifera-tion.The effects of different concentrations of ginsen-oside Rg3 on apoptosis were measured by flow cytome-try.The effects of different concentrations of ginsen-oside Rg3 on cell migration and invasion were deter-mined by scratch healing experiment and Transwell ex-periment.The effects of different concentrations of gin-senoside Rg3 on the expression of E2F1,MMP-2,MMP-9,BCL-2 and Bax were determined by Western blot.Results Compared with the blank control group,the cell survival rate of 80,160 and 320 μmol ·L-1 ginsenoside Rg3 group was significantly lower,and it was concentration-dependent(P<0.05).Com-pared with the blank control group,the apoptosis rate of 80,160 and 320 μmol·L-1 ginsenoside Rg3 group significantly increased in a concentration-dependent manner(P<0.05).Compared with the blank control group,the number of cell migration in 80,160 and 320 μmol·L-1 ginsenoside Rg3 groups was significantly lower in a concentration-dependent manner(P<0.05).Compared with the blank control group,the number of cell invasion in 80,160 and 320 μmol· L-1 ginsenoside Rg3 groups was significantly lower in a concentration-dependent manner(P<0.05).The E2F1 mRNA and E2F1 protein expression in the 80,160,and 320 μmol·L-1 ginsenoside Rg3 groups were significantly reduced in a concentration-dependent manner compared with that in the blank control group(P<0.05).The protein expression of MMP-2,MMP-9,and BCL-2 in the cells of 80,160,and 320 μmol ·L-1 ginsenoside Rg3 group significantly decreased compared with those of the blank control group,and BCL-2 significantly increased compared with that of the blank control group in a concentration-dependent man-ner(P<0.05).Conclusions Ginsenoside Rg3 can reduce the proliferation,inhibit the migration and inva-sion of gastric cancer SGC-7901 cells,and promote the apoptosis of SGC-7901 cells in a concentration-depend-ent manner,and its mechanism may be related to the down-regulation of MMP-2,MMP-9,and BCL-2 ex-pression and up-regulation of Bax expression through E2F1.

Result Analysis
Print
Save
E-mail